Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Acta Orthop ; 93: 831-836, 2022 10 31.
Article in English | MEDLINE | ID: mdl-36314542

ABSTRACT

BACKGROUND AND PURPOSE: Inducible displacement CT compares 2 CTs acquired in series but with alternated rotation of the femur. This provides visual and quantitative clues as to the mechanical situation, i.e., loosening, of a total hip arthroplasty. We report the accuracy of this method as well as the experience of integrating it into a clinical workflow. PATIENTS AND METHODS: This was a retrospective single centre study of 72 cases of suspected aseptic loosening were the surgeon after reviewing a standard plain radiograph saw a need for more information. The displacement CT and plain radiograph were compared either to intraoperative findings or a 1-3 year follow up questionnaire for patients that did not have revision surgery. Patients reporting degradation in status since the time of the displacement CT were called for a follow up plain radiograph. Sensitivity and specificity were assessed, and user experience gathered. RESULTS: Of 72 enrolled patients 15 were lost to follow up. Of the remaining 57, 17 were judged by in-traoperative findings or follow-up to have had loose implants. For plain radiography the sensitivity and specificity were 59% (95% CI 35-82) and 85% (74-96). For displacement CT the corresponding values were 77% (56-97), and 100% (100-100) respectively. The tool was adaptable to clinical routine. CONCLUSION: Displacement CT with alternated rotations of the femur is a viable option to improve the diagnostic process for identifying aseptic loosening in a total hip arthroplasty.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Arthroplasty, Replacement, Hip/adverse effects , Prosthesis Failure , Retrospective Studies , Reoperation , Tomography, X-Ray Computed , Hip Prosthesis/adverse effects , Follow-Up Studies
2.
Acta Orthop ; 91(6): 654-659, 2020 12.
Article in English | MEDLINE | ID: mdl-33063555

ABSTRACT

Background and purpose - RSA is the gold standard for evaluation of early implant migration. We report the results of a new CT-based method Sectra CT micromotion analysis (CTMA) applied to assess the migration pattern in 20 patients in the 1st year after surgery, both with and without the use of tantalum beads in the bone. The patients had an SP-CL anatomical stem that uses an S-shape, designed to better fit the curvature of the femur. Patients and methods - 20 THA patients (mean age 61 years, 10 female) received SP-CL stems, tantalum markers in the femur, and low-dose CT scans at 1 day, 3 months and 12 months postoperatively. In addition, precision as well as inter- and intra-observer variability of the 12-month migration was measured. Results - The 3-month subsidence was median 0.5 mm (95% CI 0.3-1.0) and the internal rotation 1.8° (CI 0.9-2.6). At 12 months the corresponding values were 0.6 (CI 0.3-1.6) mm and 1.9° (CI 0.8-2.4). Precision was 0.1 to 0.3 mm and 0.1° to 0.4° at 3 and 12 months. Intra- and inter- observer variability yielded R-values averaging 0.96 and 0.98. Interpretation - The migration mainly took place during the 1st 3 months, in line with other uncemented stems. The number of patients with subsidence over 2 mm in the first year (5) might be due to the design of the prosthesis with an anatomical shape. Alternatively, our results might indicate a challenge when choosing the correct size for these new anatomical stems. CTMA provided precise and highly repeatable measurements of migration without the need for tantalum markers.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Femur/diagnostic imaging , Hip Prosthesis/adverse effects , Postoperative Complications , Tomography, X-Ray Computed/methods , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Female , Humans , Male , Middle Aged , Postoperative Complications/diagnosis , Postoperative Complications/etiology , Prosthesis Design/methods , Prosthesis Failure , Radiation Dosage , Radiostereometric Analysis/methods , Sweden , Time Factors
SELECTION OF CITATIONS