Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 40
Filter
1.
Eur Radiol ; 34(1): 39-49, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37552259

ABSTRACT

OBJECTIVES: Quantitative CT imaging is an important emphysema biomarker, especially in smoking cohorts, but does not always correlate to radiologists' visual CT assessments. The objectives were to develop and validate a neural network-based slice-wise whole-lung emphysema score (SWES) for chest CT, to validate SWES on unseen CT data, and to compare SWES with a conventional quantitative CT method. MATERIALS AND METHODS: Separate cohorts were used for algorithm development and validation. For validation, thin-slice CT stacks from 474 participants in the prospective cross-sectional Swedish CArdioPulmonary bioImage Study (SCAPIS) were included, 395 randomly selected and 79 from an emphysema cohort. Spirometry (FEV1/FVC) and radiologists' visual emphysema scores (sum-visual) obtained at inclusion in SCAPIS were used as reference tests. SWES was compared with a commercially available quantitative emphysema scoring method (LAV950) using Pearson's correlation coefficients and receiver operating characteristics (ROC) analysis. RESULTS: SWES correlated more strongly with the visual scores than LAV950 (r = 0.78 vs. r = 0.41, p < 0.001). The area under the ROC curve for the prediction of airway obstruction was larger for SWES than for LAV950 (0.76 vs. 0.61, p = 0.007). SWES correlated more strongly with FEV1/FVC than either LAV950 or sum-visual in the full cohort (r = - 0.69 vs. r = - 0.49/r = - 0.64, p < 0.001/p = 0.007), in the emphysema cohort (r = - 0.77 vs. r = - 0.69/r = - 0.65, p = 0.03/p = 0.002), and in the random sample (r = - 0.39 vs. r = - 0.26/r = - 0.25, p = 0.001/p = 0.007). CONCLUSION: The slice-wise whole-lung emphysema score (SWES) correlates better than LAV950 with radiologists' visual emphysema scores and correlates better with airway obstruction than do LAV950 and radiologists' visual scores. CLINICAL RELEVANCE STATEMENT: The slice-wise whole-lung emphysema score provides quantitative emphysema information for CT imaging that avoids the disadvantages of threshold-based scores and is correlated more strongly with reference tests than LAV950 and reader visual scores. KEY POINTS: • A slice-wise whole-lung emphysema score (SWES) was developed to quantify emphysema in chest CT images. • SWES identified visual emphysema and spirometric airflow limitation significantly better than threshold-based score (LAV950). • SWES improved emphysema quantification in CT images, which is especially useful in large-scale research.


Subject(s)
Airway Obstruction , Emphysema , Pulmonary Disease, Chronic Obstructive , Pulmonary Emphysema , Humans , Prospective Studies , Cross-Sectional Studies , Pulmonary Emphysema/diagnostic imaging , Lung/diagnostic imaging , Tomography, X-Ray Computed/methods , Emphysema/diagnostic imaging , Airway Obstruction/diagnostic imaging
2.
Acta Radiol ; 65(3): 307-317, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38115809

ABSTRACT

BACKGROUND: Magnetic resonance imaging (MRI) is useful in the diagnosis of clinically significant prostate cancer (csPCa). MRI-derived radiomics may support the diagnosis of csPCa. PURPOSE: To investigate whether adding radiomics from biparametric MRI to predictive models based on clinical and MRI parameters improves the prediction of csPCa in a multisite-multivendor setting. MATERIAL AND METHODS: Clinical information (PSA, PSA density, prostate volume, and age), MRI reviews (PI-RADS 2.1), and radiomics (histogram and texture features) were retrieved from prospectively included patients examined at different radiology departments and with different MRI systems, followed by MRI-ultrasound fusion guided biopsies of lesions PI-RADS 3-5. Predictive logistic regression models of csPCa (Gleason score ≥7) for the peripheral (PZ) and transition zone (TZ), including clinical data and PI-RADS only, and combined with radiomics, were built and compared using receiver operating characteristic (ROC) curves. RESULTS: In total, 456 lesions in 350 patients were analyzed. In PZ and TZ, PI-RADS 4-5 and PSA density, and age in PZ, were independent predictors of csPCa in models without radiomics. In models including radiomics, PI-RADS 4-5, PSA density, age, and ADC energy were independent predictors in PZ, and PI-RADS 5, PSA density and ADC mean in TZ. Comparison of areas under the ROC curve (AUC) for the models without radiomics (PZ: AUC = 0.82, TZ: AUC = 0.80) versus with radiomics (PZ: AUC = 0.82, TZ: AUC = 0.82) showed no significant differences (PZ: P = 0.366; TZ: P = 0.171). CONCLUSION: PSA density and PI-RADS are potent predictors of csPCa. Radiomics do not add significant information to our multisite-multivendor dataset.


Subject(s)
Magnetic Resonance Imaging , Prostatic Neoplasms , Male , Humans , Magnetic Resonance Imaging/methods , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Prostate-Specific Antigen , Radiomics , ROC Curve , Retrospective Studies
3.
BMC Psychiatry ; 23(1): 771, 2023 10 23.
Article in English | MEDLINE | ID: mdl-37872497

ABSTRACT

BACKGROUND: The role of inflammation in the aetiology of schizophrenia has gained wide attention and research on the association shows an exponential growth in the last 15 years. Autoimmune diseases and severe infections are risk factors for the later development of schizophrenia, elevated inflammatory markers in childhood or adolescence are associated with a greater risk of schizophrenia in adulthood, individuals with schizophrenia have increased levels of pro-inflammatory cytokines compared to healthy controls, and autoimmune diseases are overrepresented in schizophrenia. However, treatments with anti-inflammatory agents are so far of doubtful clinical relevance. The primary objective of this study is to test whether the monoclonal antibody rituximab, directed against the B-cell antigen CD20 ameliorates psychotic symptoms in adults with schizophrenia or schizoaffective disorder and to examine potential mechanisms. A secondary objective is to examine characteristics of inflammation-associated psychosis and to identify pre-treatment biochemical characteristics of rituximab responders. A third objective is to interview a subset of patients and informants on their experiences of the trial to obtain insights that rating scales may not capture. METHODS: A proof-of-concept study employing a randomised, parallel-group, double-blind, placebo-controlled design testing the effect of B-cell depletion in patients with psychosis. 120 participants with a diagnosis of schizophrenia spectrum disorders (SSD) (ICD-10 codes F20, F25) will receive either one intravenous infusion of rituximab (1000 mg) or saline. Psychiatric measures and blood samples will be collected at baseline, week 12, and week 24 post-infusion. Brief assessments will also be made in weeks 2 and 7. Neuroimaging and lumbar puncture, both optional, will be performed at baseline and endpoints. Approximately 40 of the patients and their informants will be interviewed for qualitative analyses on the perceived changes in well-being and emotional qualities, in addition to their views on the research. DISCUSSION: This is the first RCT investigating add-on treatment with rituximab in unselected SSD patients. If the treatment is helpful, it may transform the treatment of patients with psychotic disorders. It may also heighten the awareness of immune-psychiatric disorders and reduce stigma. TRIAL REGISTRATION: NCT05622201, EudraCT-nr 2022-000220-37 version 2.1. registered 14th of October 2022.


Subject(s)
Autoimmune Diseases , Psychotic Disorders , Adult , Humans , Double-Blind Method , Inflammation , Psychotic Disorders/drug therapy , Randomized Controlled Trials as Topic , Rituximab/therapeutic use , Treatment Outcome
4.
J Psychiatr Res ; 163: 378-385, 2023 07.
Article in English | MEDLINE | ID: mdl-37269772

ABSTRACT

BACKGROUND: Roughly 20-30% of patients with Attention-deficit/hyperactivity disorder (ADHD) fail to respond to central stimulant (CS) medication. Genetic, neuroimaging, biochemical and behavioral biomarkers for CS response have been investigated, but currently there are no biomarkers available for clinical use that help identify CS responders and non-responders. METHODS: In the present paper, we studied if incentive salience and hedonic experience evaluated after a single-dose CS medication could predict response and non-response to CS medication. We used a bipolar visual analogue 'wanting' and 'liking' scale to gauge incentive salience and hedonic experience in 25 healthy controls (HC) and 29 ADHD patients. HC received 30 mg methylphenidate (MPH) and ADHD patients received either MPH or lisdexamphetamine (LDX) as selected by their clinician, with dosage individually determined for optimal effect. Clinician-evaluated global impression - severity (CGI-S) and improvement (CGI-I) and patient-evaluated improvement (PGI-I) were used to assess response to CS medication. Resting state functional magnetic resonance imaging (fMRI) was conducted before and after single-dose CS to correlate wanting and liking scores to changes in functional connectivity. RESULTS: Roughly 20% of the ADHD patients were CS non-responders (5 of 29). CS responders had significantly higher incentive salience and hedonic experience scores compared to healthy controls and CS non-responders. Resting state fMRI showed that wanting scores were significantly associated to changes in functional connectivity in ventral striatum including nucleus accumbens. CONCLUSION: Incentive salience and hedonic experience evaluated after a single-dose CS medication segregate CS responders and non-responders, with corresponding neuroimaging biomarkers in the brain reward system.


Subject(s)
Attention Deficit Disorder with Hyperactivity , Central Nervous System Stimulants , Methylphenidate , Humans , Central Nervous System Stimulants/therapeutic use , Attention Deficit Disorder with Hyperactivity/diagnostic imaging , Attention Deficit Disorder with Hyperactivity/drug therapy , Magnetic Resonance Imaging , Brain/diagnostic imaging , Motivation , Methylphenidate/pharmacology , Methylphenidate/therapeutic use
5.
Cells ; 11(18)2022 09 19.
Article in English | MEDLINE | ID: mdl-36139496

ABSTRACT

Probiotics can alter brain function via the gut-brain axis. We investigated the effect of a probiotic mixture containing Bifidobacterium longum, Lactobacillus helveticus and Lactiplantibacillus plantarum. In a randomized, placebo-controlled, double-blinded crossover design, 22 healthy subjects (6 m/16 f; 24.2 ± 3.4 years) underwent four-week intervention periods with probiotics and placebo, separated by a four-week washout period. Voxel-based morphometry indicated that the probiotic intervention affected the gray matter volume of a cluster covering the left supramarginal gyrus and superior parietal lobule (p < 0.0001), two regions that were also among those with an altered resting state functional connectivity. Probiotic intervention resulted in significant (FDR < 0.05) functional connectivity changes between regions within the default mode, salience, frontoparietal as well as the language network and several regions located outside these networks. Psychological symptoms trended towards improvement after probiotic intervention, i.e., the total score of the Hospital Anxiety and Depression Scale (p = 0.056) and its depression sub-score (p = 0.093), as well as sleep patterns (p = 0.058). The probiotic intervention evoked distinct changes in brain morphology and resting state brain function alongside slight improvements of psycho(bio)logical markers of the gut-brain axis. The combination of those parameters may provide new insights into the modes of action by which gut microbiota can affect gut-brain communication and hence brain function.


Subject(s)
Bifidobacterium longum , Lactobacillus helveticus , Probiotics , Brain , Healthy Volunteers , Humans , Probiotics/therapeutic use
6.
Front Nutr ; 9: 827182, 2022.
Article in English | MEDLINE | ID: mdl-35571902

ABSTRACT

Background: Evidence from preclinical studies suggests that probiotics affect brain function via the microbiome-gut-brain axis, but evidence in humans remains limited. Objective: The present proof-of-concept study investigated if a probiotic product containing a mixture of Bifidobacterium longum R0175, Lactobacillus helveticus R0052 and Lactiplantibacillus plantarum R1012 (in total 3 × 109 CFU/day) affected functional brain responses in healthy subjects during an emotional attention task. Design: In this double-blinded, randomized, placebo-controlled crossover study (Clinicaltrials.gov, NCT03615651), 22 healthy subjects (24.2 ± 3.4 years, 6 males/16 females) were exposed to a probiotic intervention and a placebo for 4 weeks each, separated by a 4-week washout period. Subjects underwent functional magnetic resonance imaging while performing an emotional attention task after each intervention period. Differential brain activity and functional connectivity were assessed. Results: Altered brain responses were observed in brain regions implicated in emotional, cognitive and face processing. Increased activation in the orbitofrontal cortex, a region that receives extensive sensory input and in turn projects to regions implicated in emotional processing, was found after probiotic intervention compared to placebo using a cluster-based analysis of functionally defined areas. Significantly reduced task-related functional connectivity was observed after the probiotic intervention compared to placebo. Fecal microbiota composition was not majorly affected by probiotic intervention. Conclusion: The probiotic intervention resulted in subtly altered brain activity and functional connectivity in healthy subjects performing an emotional task without major effects on the fecal microbiota composition. This indicates that the probiotic effects occurred via microbe-host interactions on other levels. Further analysis of signaling molecules could give possible insights into the modes of action of the probiotic intervention on the gut-brain axis in general and brain function specifically. The presented findings further support the growing consensus that probiotic supplementation influences brain function and emotional regulation, even in healthy subjects. Future studies including patients with altered emotional processing, such as anxiety or depression symptoms are of great interest. Clinical Trial Registration: [http://clinicaltrials.gov/], identifier [NCT03615651].

7.
Nutrients ; 14(7)2022 Mar 22.
Article in English | MEDLINE | ID: mdl-35405944

ABSTRACT

Probiotics are suggested to impact physiological and psychological stress responses by acting on the gut-brain axis. We investigated if a probiotic product containing Bifidobacterium longum R0175, Lactobacillus helveticus R0052 and Lactiplantibacillus plantarum R1012 affected stress processing in a double-blinded, randomised, placebo-controlled, crossover proof-of-concept study (NCT03615651). Twenty-two healthy subjects (24.2 ± 3.4 years, 6 men/16 women) underwent a probiotic and placebo intervention for 4 weeks each, separated by a 4-week washout period. Subjects were examined by functional magnetic resonance imaging while performing the Montreal Imaging Stress Task (MIST) as well as an autonomic nervous system function assessment during the Stroop task. Reduced activation in regions of the lateral orbital and ventral cingulate gyri was observed after probiotic intervention compared to placebo. Significantly increased functional connectivity was found between the upper limbic region and medioventral area. Interestingly, probiotic intervention seemed to predominantly affect the initial stress response. Salivary cortisol secretion during the task was not altered. Probiotic intervention did not affect cognitive performance and autonomic nervous system function during Stroop. The probiotic intervention was able to subtly alter brain activity and functional connectivity in regions known to regulate emotion and stress responses. These findings support the potential of probiotics as a non-pharmaceutical treatment modality for stress-related disorders.


Subject(s)
Bifidobacterium longum , Lactobacillus helveticus , Probiotics , Brain/diagnostic imaging , Double-Blind Method , Female , Healthy Volunteers , Humans , Male
8.
Eur J Radiol Open ; 8: 100357, 2021.
Article in English | MEDLINE | ID: mdl-34095355

ABSTRACT

BACKGROUND: Patients with transfusion dependent anemia are at risk of complications from iron overload. Quantitative T2* magnetic resonance imaging (MRI) is the best non-invasive method to assess iron deposition in the liver and heart and to guide chelation therapy. PURPOSE: To investigate the image quality and inter-observer variations in T2* measurements of the myocardium and the liver, and to obtain the lower limit of cardiac and hepatic quantitative T2* values in patients without suspicion of iron overload. MATERIAL AND METHODS: Thirty-eight patients referred for cardiac MRI were prospectively included in the study. Three patients were referred with, and 35 without suspicion of iron overload. Quantitative T2* parametric maps were obtained on a 1.5 T MRI system in the cardiac short axis and liver axial view. Two readers independently assessed the image quality and the representative and the lowest T2* value in the myocardium and the liver. RESULTS: The normal range of representative T2* values in the myocardium and liver was 24-45 ms and 14-37 ms, respectively. None of the 35 participants (0 %, 95 % confidence interval 0-11 %) in the normal reference group demonstrated representative T2* values below previously reported lower limits in the myocardium (20 ms) or the liver (8 ms). Focal myocardial areas with T2* values near the lower normal range, 19-20 ms, were seen in two patients. The readers generally reported good image quality. CONCLUSION: T2* imaging for assessing iron overload can be performed in a non-dedicated center with sufficient image quality.

9.
Eur Radiol ; 31(8): 5980-5989, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33635394

ABSTRACT

OBJECTIVES: To prospectively validate three quantitative single-energy CT (SE-CT) methods for classifying uric acid (UA) and non-uric acid (non-UA) stones. METHODS: Between September 2018 and September 2019, 116 study participants were prospectively included in the study if they had at least one 3-20-mm urinary stone on an initial urinary tract SE-CT scan. An additional dual-energy CT (DE-CT) scan was performed, limited to the stone of interest. Additionally, to include a sufficient number of UA stones, eight participants with confirmed UA stone on DE-CT were retrospectively included. The SE-CT stone features used in the prediction models were (1) maximum attenuation (maxHU) and (2) the peak point Laplacian (ppLapl) calculated at the position in the stone with maxHU. Two prediction models were previously published methods (ppLapl-maxHU and maxHU) and the third was derived from the previous results based on the k-nearest neighbors (kNN) algorithm (kNN-ppLapl-maxHU). The three methods were evaluated on this new independent stone dataset. The reference standard was the CT vendor's DE-CT application for kidney stones. RESULTS: Altogether 124 participants (59 ± 14 years, 91 men) with 106 non-UA and 37 UA stones were evaluated. For classification of UA and non-UA stones, the sensitivity, specificity, and accuracy were 100% (37/37), 97% (103/106), and 98% (140/143), respectively, for kNN-ppLapl-maxHU; 95% (35/37), 98% (104/106), and 97% (139/143) for ppLapl-maxHU; and 92% (34/37), 94% (100/106), and 94% (134/143) for maxHU. CONCLUSION: A quantitative SE-CT method (kNN-ppLapl-maxHU) can classify UA stones with accuracy comparable to DE-CT. KEY POINTS: • Single-energy CT is the first-line diagnostic tool for suspected renal colic. • A single-energy CT method based on the internal urinary stone attenuation distribution can classify urinary stones into uric acid and non-uric acid stones with high accuracy. • This immensely increases the availability of in vivo stone analysis.


Subject(s)
Uric Acid , Urinary Calculi , Humans , Male , Prospective Studies , Retrospective Studies , Tomography, X-Ray Computed , Urinary Calculi/diagnostic imaging
10.
Urolithiasis ; 49(1): 41-49, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32107579

ABSTRACT

The objectives were to develop and validate a Convolutional Neural Network (CNN) using local features for differentiating distal ureteral stones from pelvic phleboliths, compare the CNN method with a semi-quantitative method and with radiologists' assessments and to evaluate whether the assessment of a calcification and its local surroundings is sufficient for discriminating ureteral stones from pelvic phleboliths in non-contrast-enhanced CT (NECT). We retrospectively included 341 consecutive patients with acute renal colic and a ureteral stone on NECT showing either a distal ureteral stone, a phlebolith or both. A 2.5-dimensional CNN (2.5D-CNN) model was used, where perpendicular axial, coronal and sagittal images through each calcification were used as input data for the CNN. The CNN was trained on 384 calcifications, and evaluated on an unseen dataset of 50 stones and 50 phleboliths. The CNN was compared to the assessment by seven radiologists who reviewed a local 5 × 5 × 5 cm image stack surrounding each calcification, and to a semi-quantitative method using cut-off values based on the attenuation and volume of the calcifications. The CNN differentiated stones and phleboliths with a sensitivity, specificity and accuracy of 94%, 90% and 92% and an AUC of 0.95. This was similar to a majority vote accuracy of 93% and significantly higher (p = 0.03) than the mean radiologist accuracy of 86%. The semi-quantitative method accuracy was 49%. In conclusion, the CNN differentiated ureteral stones from phleboliths with higher accuracy than the mean of seven radiologists' assessments using local features. However, more than local features are needed to reach optimal discrimination.


Subject(s)
Neural Networks, Computer , Renal Colic/diagnosis , Tomography, X-Ray Computed/methods , Ureteral Calculi/diagnosis , Vascular Calcification/diagnosis , Adolescent , Adult , Aged , Aged, 80 and over , Datasets as Topic , Diagnosis, Differential , Female , Humans , Male , Middle Aged , Pelvis/blood supply , Pelvis/diagnostic imaging , ROC Curve , Renal Colic/etiology , Retrospective Studies , Ureter/diagnostic imaging , Ureteral Calculi/complications , Vascular Calcification/pathology , Veins/diagnostic imaging , Veins/pathology , Young Adult
11.
Med Phys ; 47(12): 6414-6420, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33012023

ABSTRACT

PURPOSE: To develop, and evaluate the performance of, a deep learning-based three-dimensional (3D) convolutional neural network (CNN) artificial intelligence (AI) algorithm aimed at finding needles in ultrasound images used in prostate brachytherapy. METHODS: Transrectal ultrasound (TRUS) image volumes from 1102 treatments were used to create a clinical ground truth (CGT) including 24422 individual needles that had been manually digitized by medical physicists during brachytherapy procedures. A 3D CNN U-net with 128 × 128 × 128 TRUS image volumes as input was trained using 17215 needle examples. Predictions of voxels constituting a needle were combined to yield a 3D linear function describing the localization of each needle in a TRUS volume. Manual and AI digitizations were compared in terms of the root-mean-square distance (RMSD) along each needle, expressed as median and interquartile range (IQR). The method was evaluated on a data set including 7207 needle examples. A subgroup of the evaluation data set (n = 188) was created, where the needles were digitized once more by a medical physicist (G1) trained in brachytherapy. The digitization procedure was timed. RESULTS: The RMSD between the AI and CGT was 0.55 (IQR: 0.35-0.86) mm. In the smaller subset, the RMSD between AI and CGT was similar (0.52 [IQR: 0.33-0.79] mm) but significantly smaller (P < 0.001) than the difference of 0.75 (IQR: 0.49-1.20) mm between AI and G1. The difference between CGT and G1 was 0.80 (IQR: 0.48-1.18) mm, implying that the AI performed as well as the CGT in relation to G1. The mean time needed for human digitization was 10 min 11 sec, while the time needed for the AI was negligible. CONCLUSIONS: A 3D CNN can be trained to identify needles in TRUS images. The performance of the network was similar to that of a medical physicist trained in brachytherapy. Incorporating a CNN for needle identification can shorten brachytherapy treatment procedures substantially.


Subject(s)
Brachytherapy , Deep Learning , Prostatic Neoplasms , Artificial Intelligence , Humans , Imaging, Three-Dimensional , Male , Needles , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Ultrasonography
12.
J Digit Imaging ; 33(5): 1185-1193, 2020 10.
Article in English | MEDLINE | ID: mdl-32779016

ABSTRACT

Emphysema is visible on computed tomography (CT) as low-density lesions representing the destruction of the pulmonary alveoli. To train a machine learning model on the emphysema extent in CT images, labeled image data is needed. The provision of these labels requires trained readers, who are a limited resource. The purpose of the study was to test the reading time, inter-observer reliability and validity of the multi-reader-multi-split method for acquiring CT image labels from radiologists. The approximately 500 slices of each stack of lung CT images were split into 1-cm chunks, with 17 thin axial slices per chunk. The chunks were randomly distributed to 26 readers, radiologists and radiology residents. Each chunk was given a quick score concerning emphysema type and severity in the left and right lung separately. A cohort of 102 subjects, with varying degrees of visible emphysema in the lung CT images, was selected from the SCAPIS pilot, performed in 2012 in Gothenburg, Sweden. In total, the readers created 9050 labels for 2881 chunks. Image labels were compared with regional annotations already provided at the SCAPIS pilot inclusion. The median reading time per chunk was 15 s. The inter-observer Krippendorff's alpha was 0.40 and 0.53 for emphysema type and score, respectively, and higher in the apical part than in the basal part of the lungs. The multi-split emphysema scores were generally consistent with regional annotations. In conclusion, the multi-reader-multi-split method provided reasonably valid image labels, with an estimation of the inter-observer reliability.


Subject(s)
Pulmonary Emphysema , Female , Humans , Lung , Male , Middle Aged , Observer Variation , Pulmonary Emphysema/diagnostic imaging , Reproducibility of Results , Tomography, X-Ray Computed
13.
Med Phys ; 45(10): 4329-4344, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30076784

ABSTRACT

PURPOSE: To evaluate two commercial CT metal artifact reduction (MAR) algorithms for use in proton treatment planning in the head and neck (H&N) area. METHODS: An anthropomorphic head phantom with removable metallic implants (dental fillings or neck implant) was CT-scanned to evaluate the O-MAR (Philips) and the iMAR (Siemens) algorithms. Reference images were acquired without any metallic implants in place. Water equivalent thickness (WET) was calculated for different path directions and compared between image sets. Images were also evaluated for use in proton treatment planning for parotid, tonsil, tongue base, and neck node targets. The beams were arranged so as to not traverse any metal prior to the target, enabling evaluation of the impact on dose calculation accuracy from artifacts surrounding the metal volume. Plans were compared based on γ analysis (1 mm distance-to-agreement/1% difference in local dose) and dose volume histogram metrics for targets and organs at risk (OARs). Visual grading evaluation of 30 dental implant patient MAR images was performed by three radiation oncologists. RESULTS: In the dental fillings images, ΔWET along a low-density streak was reduced from -17.0 to -4.3 mm with O-MAR and from -16.1 mm to -2.3 mm with iMAR, while for other directions the deviations were increased or approximately unchanged when the MAR algorithms were used. For the neck implant images, ΔWET was generally reduced with MAR but residual deviations remained (of up to -2.3 mm with O-MAR and of up to -1.5 mm with iMAR). The γ analysis comparing proton dose distributions for uncorrected/MAR plans and corresponding reference plans showed passing rates >98% of the voxels for all phantom plans. However, substantial dose differences were seen in areas of most severe artifacts (γ passing rates of down to 89% for some cases). MAR reduced the deviations in some cases, but not for all plans. For a single patient case dosimetrically evaluated, minor dose differences were seen between the uncorrected and MAR plans (γ passing rate approximately 97%). The visual grading of patient images showed that MAR significantly improved image quality (P < 0.001). CONCLUSIONS: O-MAR and iMAR significantly improved image quality in terms of anatomical visualization for target and OAR delineation in dental implant patient images. WET calculations along several directions, all outside the metallic regions, showed that both uncorrected and MAR images contained metal artifacts which could potentially lead to unacceptable errors in proton treatment planning. ΔWET was reduced by MAR in some areas, while increased or unchanged deviations were seen for other path directions. The proton treatment plans created for the phantom images showed overall acceptable dose distributions differences when compared to the reference cases, both for the uncorrected and MAR images. However, substantial dose distribution differences in the areas of most severe artifacts were seen for some plans, which were reduced by MAR in some cases but not all. In conclusion, MAR could be beneficial to use for proton treatment planning; however, case-by-case evaluations of the metal artifact-degraded images are always recommended.


Subject(s)
Algorithms , Artifacts , Head and Neck Neoplasms/radiotherapy , Image Processing, Computer-Assisted/methods , Metals , Proton Therapy , Radiotherapy Planning, Computer-Assisted/methods , Tomography, X-Ray Computed , Dental Implants , Head and Neck Neoplasms/diagnostic imaging , Humans , Radiotherapy Dosage
14.
Comput Biol Med ; 97: 153-160, 2018 06 01.
Article in English | MEDLINE | ID: mdl-29730498

ABSTRACT

Computed tomography (CT) is the method of choice for diagnosing ureteral stones - kidney stones that obstruct the ureter. The purpose of this study is to develop a computer aided detection (CAD) algorithm for identifying a ureteral stone in thin slice CT volumes. The challenge in CAD for urinary stones lies in the similarity in shape and intensity of stones with non-stone structures and how to efficiently deal with large high-resolution CT volumes. We address these challenges by using a Convolutional Neural Network (CNN) that works directly on the high resolution CT volumes. The method is evaluated on a large data base of 465 clinically acquired high-resolution CT volumes of the urinary tract with labeling of ureteral stones performed by a radiologist. The best model using 2.5D input data and anatomical information achieved a sensitivity of 100% and an average of 2.68 false-positives per patient on a test set of 88 scans.


Subject(s)
Neural Networks, Computer , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Ureteral Calculi/diagnostic imaging , Adult , Algorithms , Databases, Factual , Female , Humans , Male , Supervised Machine Learning
15.
Eur Radiol ; 28(4): 1692-1700, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29134354

ABSTRACT

OBJECTIVES: To compare the assessment of patients with multiple sclerosis (MS) using synthetic and conventional MRI. MATERIALS AND METHODS: Synthetic and conventional axial images were prospectively acquired for 52 patients with diagnosed MS. Quantitative MRI (qMRI) was used for measuring proton density and relaxation times (T1, T2) and then, based on these parameters, synthetic T1W, T2W and FLAIR images were calculated. Image stacks were reviewed blindly, independently and in random order by two radiologists. The number and location for all lesions were documented and categorised. A combined report of lesion load and presence of contrast-enhancing lesions was compiled for each patient. Agreement was evaluated using kappa statistic. RESULTS: There was no significant difference in lesion detection using synthetic and conventional MRI in any anatomical region or for any of the three image types. Inter- and intra-observer agreements were mainly higher (p < 0.05) using conventional images but there was no significant difference in any specific region or for any image type. There was no significant difference in the outcome of the combined reports. CONCLUSION: Synthetic MR images show potential to be used in the assessment of MS dissemination in space (DIS) despite a slightly lower inter- and intra-observer agreement compared to conventional MRI. KEY POINTS: • Synthetic MR images may potentially be useful in the assessment of MS. • Examination times may be shortened. • Inter- and intra-observer agreement is generally higher using conventional MRI.


Subject(s)
Magnetic Resonance Imaging/methods , Multiple Sclerosis/diagnostic imaging , Adult , Aged , Contrast Media , Female , Humans , Male , Middle Aged , Multiple Sclerosis/pathology , Observer Variation , Protons , Time Factors , Young Adult
16.
J Contemp Brachytherapy ; 9(1): 52-58, 2017 Feb.
Article in English | MEDLINE | ID: mdl-28344604

ABSTRACT

PURPOSE: Using 3D image-guided adaptive brachytherapy for cervical cancer treatment, it often means that patients are transported and moved during the treatment procedure. The purpose of this study was to determine the intra-fractional longitudinal applicator shift in relation to the high risk clinical target volume (HR-CTV) by comparing geometries at imaging and dose delivery for patients with and without needles. MATERIAL AND METHODS: Measurements were performed in 33 patients (71 fractions), where 25 fractions were without and 46 were with interstitial needles. Gold markers were placed in the lower part of the cervix as a surrogate for HR-CTV, enabling distance measurements between HR-CTV and the ring applicator. Shifts of the applicator relative to the markers were determined using planning computed tomography (CT) images used for planning, and the radiographs obtained at dose delivery. Differences in the physical D90 for HR-CTV due to applicator shifts were simulated individually in the treatment planning system to provide the relative dose variation. RESULTS: The maximum distances of the applicator shifts, in relation to the markers, were 3.6 mm (caudal), and -2.5 mm (cranial). There was a significant displacement of -0.7 mm (SD = 0.9 mm) without needles, while with needles there was no significant shift. The relative dose variation showed a significant increase in D90 HR-CTV of 1.6% (SD = 2.6%) when not using needles, and no significant dose variation was found when using needles. CONCLUSIONS: The results from this study showed that there was a small longitudinal displacement of the ring applicator and a significant difference in displacement between using interstitial needles or not.

17.
Cardiovasc Ultrasound ; 15(1): 4, 2017 Mar 07.
Article in English | MEDLINE | ID: mdl-28270161

ABSTRACT

BACKGROUND: There is today no established approach to estimate right ventricular ejection fraction (RVEF) using 2D transthoracic echocardiography (TTE). The aim of this study was to evaluate a new method for RVEF calculations using 2D TTE and compare the results with cardiac magnetic resonance (CMR) imaging and tricuspid annular plane systolic excursion (TAPSE). METHODS: A total of 37 subjects, 25 retrospectively included patients and twelve healthy volunteers, were included to give a wide range of RVEF. The right ventricle (RV) was modeled as a part of an ellipsoid enabling calculation of the RV volume by combining three distance measurements. RVEF calculated according to the model, RVEFTTE, were compared with reference CMR-derived RVEF, RVEFCMR. Further, TAPSE was measured in the TTE images and the correlations were calculated between RVEFTTE, TAPSE and RVEFCMR. RESULTS: The mean values were RVEFCMR = 43 ± 12% (range 20-66%) and RVEFTTE = 50 ± 9% (range 34-65%). There was a high correlation (r = 0.80, p < 0.001) between RVEFTTE and RVEFCMR. Bland-Altman analysis showed a mean difference between RVEFCMR and RVEFTTE of 6 percentage points (ppt) with limits of agreement from -11 to 23 ppt. The mean value for TAPSE was 19 ± 5 mm and the correlation between TAPSE and RVEFCMR was moderate (r = 0.54, p < 0.001). The correlation between RVEFTTE and RVEFCMR was significantly higher (p < 0.05) than the correlation between TAPSE and RVEFCMR. CONCLUSIONS: The ellipsoid model shows promise for RVEF calculations using 2D TTE for a wide range of RVEF, providing RVEF estimates that were significantly better correlated to RVEF obtained from CMR compared to TAPSE.


Subject(s)
Heart Ventricles/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Models, Theoretical , Stroke Volume/physiology , Ventricular Dysfunction, Right/physiopathology , Ventricular Function, Right/physiology , Adult , Female , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , Ventricular Dysfunction, Right/diagnosis
18.
J Heart Valve Dis ; 26(5): 502-508, 2017 09.
Article in English | MEDLINE | ID: mdl-29762918

ABSTRACT

BACKGROUND: Flow measurements using cardiac magnetic resonance imaging (CMRI) enable quantification of the stroke volume, regurgitant volume (RV) and regurgitant fraction (RF) in patients with aortic regurgitation (AR). These variables are used to assess the severity of the valve disease and for the timing of surgery. The aim of the study was to investigate the impact of an increased heart rate on measurement of the RV and RF in patients with AR. METHODS: Among 13 patients with known moderate or severe AR, regurgitant flow measurements, using phase-contrast cine magnetic resonance imaging, were obtained in the ascending aorta. Flow measurements were obtained at rest and at increased heart rates after intravenous administration of atropine. RESULTS: The mean heart rate was 61 beats per min at rest and 91 beats per min after atropine administration. The RV and RF were 52 ml and 35% at rest, respectively, and 34 ml (p <0.001) and 30% (p = 0.065) at increased heart rate, respectively. CONCLUSIONS: An increased heart rate leads to a decreased RV. The RF is more stable and may therefore be preferable for severity grading in AR.


Subject(s)
Aortic Valve Insufficiency , Atropine/pharmacology , Blood Flow Velocity/physiology , Heart Rate/drug effects , Aged , Anti-Arrhythmia Agents/pharmacology , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/physiopathology , Echocardiography/methods , Female , Heart Rate/physiology , Humans , Magnetic Resonance Imaging, Cine/methods , Male , Middle Aged , Reproducibility of Results , Severity of Illness Index , Stroke Volume , Time-to-Treatment
19.
Br J Radiol ; 89(1063): 20150993, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27123700

ABSTRACT

OBJECTIVE: To evaluate metal artefact reduction (MAR) techniques from four CT vendors in hip prosthesis imaging. METHODS: Bilateral hip prosthesis phantom images, obtained by using MAR algorithms for single-energy CT data or dual-energy CT (DECT) data and by monoenergetic reconstructions of DECT data, were visually graded by five radiologists using 10 image quality criteria. Comparisons between the MAR images and a reference image were performed for each scanner separately. Ordinal probit regression analysis was used. RESULTS: The MAR algorithms in general improved the image quality based on the majority of the criteria (up to between 8/10 and 10/10) with a statistical improvement in overall image quality (p < 0.001). However, degradation of image quality, such as new artefacts, was seen in some cases. A few monoenergetic reconstruction series improved the image quality (p < 0.004) for one of the DECT scanners, but it was only improved for some of the criteria (up to 5/10). Monoenergetic reconstructions resulted in worse image quality for the majority of the criteria (up to 7/10) for the other DECT scanner. CONCLUSION: The MAR algorithms improved the image quality of the hip prosthesis CT images. However, since additional artefacts and degradation of image quality were seen in some cases, all algorithms should be carefully evaluated for every clinical situation. Monoenergetic reconstructions were in general concluded to be insufficient for reducing metal artefacts. ADVANCES IN KNOWLEDGE: Qualitative evaluation of the usefulness of several MAR techniques from different vendors in CT imaging of hip prosthesis.


Subject(s)
Artifacts , Hip Joint/diagnostic imaging , Hip Prosthesis , Metals , Phantoms, Imaging , Tomography, X-Ray Computed , Algorithms , Humans , Reproducibility of Results , Sensitivity and Specificity
20.
Echocardiography ; 33(6): 844-53, 2016 Jun.
Article in English | MEDLINE | ID: mdl-26841195

ABSTRACT

BACKGROUND: The position of the right ventricle (RV), often partly behind the sternum, implies difficulties to image the RV free wall using transthoracic echocardiography (TTE) and consequently limits the possibilities of stroke volume calculations. The aim of this study was to evaluate whether the volume of the right ventricle (RV) can be determined by combining TTE distance measurements that do not need the RV free wall to be fully visualized. METHODS: The RV volume was approximated by an ellipsoid composed of three distances. Distance measurements, modeled RV stroke volumes (RVSV), and RV ejection fraction (RVEF) were compared to reference values obtained from cardiac magnetic resonance (CMR) imaging for 12 healthy volunteers. RESULTS: Inter-modality comparisons showed that distance measurements were significantly underestimated in TTE compared to CMR. The modeled RV volumes using TTE distance measurements were underestimated compared to reference CMR volumes. There was, however, for TTE an agreement between modeled RVSV and left ventricular stroke volumes determined by biplane Simpson's rule. Similar agreement was shown between modeled RVSV based on CMR distance measurements and the CMR reference. Regarding RVEF, further studies including patients with a wider range of RVEF are needed to evaluate the method. CONCLUSION: In conclusion, the ellipsoid model of the RV provides good estimates of RVSVs, but volumes based on distance measurements from different modalities cannot be used interchangeably.


Subject(s)
Anatomic Landmarks/anatomy & histology , Anatomic Landmarks/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Heart Ventricles/anatomy & histology , Heart Ventricles/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Adolescent , Adult , Aged , Female , Humans , Image Enhancement/methods , Male , Middle Aged , Organ Size , Sensitivity and Specificity , Stroke Volume , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...