Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 64
Filter
1.
Eur Heart J Digit Health ; 5(3): 356-362, 2024 May.
Article in English | MEDLINE | ID: mdl-38774365

ABSTRACT

Aims: Electroanatomical mapping (EAM) systems are essential for the treatment of cardiac arrhythmias. The EAM system is usually operated by qualified staff or field technical engineers from the control room. Novel remote support technology allows for remote access of EAM via online services. Remote access increases the flexibility of the electrophysiological lab, reduces travel time, and overcomes hospital access limitations especially during the COVID-19 pandemic. Here, we report on the feasibility and safety of EAM remote access for cardiac ablation procedures. Methods and results: Mapping and ablation were achieved by combining the EnsiteX™ EAM system and the integrated Ensite™ Connect Remote Support software, together with an integrated audiovisual solution system for remote support (Medinbox). Communication between the operator and the remote support was achieved using an incorporated internet-based common communication platform (Zoom™), headphones, and high-resolution cameras. We investigated 50 remote access-assisted consecutive electrophysiological procedures from September 2022 to February 2023 (remote group). The data were compared with matched patients (n = 50) with onsite support from the control room (control group). The median procedure time was 100 min (76, 120; remote) vs. 86 min (60, 110; control), P = 0.090. The procedural success (both groups 100%, P = 0.999) and complication rate (remote: 2%, control: 0%, P = 0.553) were comparable between the groups. Travel burden could be reduced by 11 280 km. Conclusion: Remote access for EAM was feasible and safe in this single-centre study. Procedural data were comparable to procedures with onsite support. In the future, this new solution might have a great impact on facilitating electrophysiological procedures.

3.
Int J Cardiol Heart Vasc ; 50: 101325, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38419611

ABSTRACT

Background: Very high-power short-duration (vHP-SD) radiofrequency (RF) ablation of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective and faster procedures. Although acute efficacy and safety for PVI was recently shown data on chronic PVI durability is limited. Here chronic PVI durability was evaluated during repeat electrophysiological procedures in patients after initial vHP-SD and conventional RF based PVI. Methods: A total of 25 consecutive patients with repeat left atrial procedures after initial vHP-SD based PVI were included in this study. Twenty-five patients with previous conventional RF based PVI and repeat left atrial procedures served as control (control group). Results: For index procedures the median RF time was 328 (277, 392) seconds (vHP-SD) and 1470 (1310, 1742) seconds (control); p < 0.001, the median procedure time was 55 (53, 68) minutes (vHP-SD) and 110 (94, 119) (control); p < 0.001). First pass isolation rate was 84 % (vHP-SD) and 88 % (control, p = 0.888). No differences for severe adverse events (vHP-SD: 1/25, 4 % vs. control: 0/25, 0 %; p = 0.676 were detected.Chronic durability of all PVs was assessed in vHP-SD: 16/25 (64 %) and control: 8/25 (32 %) patients (p = 0.023) and vHP-SD: 81 % and control: 62 % of PVs were found to be isolated (p = 0.003). For right PVs vHP-SD: 84 % vs. control: 60 % of PVs (p < 0.001) and for left PVs vHP-SD: 78 % vs. control: 64 % (p = 0.123) were found to be isolated. Conclusions: PVI solely utilizing vHP-SD via a very close-protocol provides fast, safe and effective acute PVI. High rates of chronically isolated pulmonary veins have been detected.

4.
Heart Rhythm ; 2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38336193

ABSTRACT

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.

5.
J Cardiovasc Electrophysiol ; 35(1): 78-85, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37942843

ABSTRACT

INTRODUCTION: Atrio-esophageal fistula after esophageal thermal injury (ETI) is one of the most devastating complications of available energy sources for atrial fibrillation (AF) ablation. Pulsed field ablation (PFA) uses electroporation as a new energy source for catheter ablation with promising periprocedural safety advantages over existing methods due to its unique myocardial tissue sensitivity. In preclinical animal studies, a dose-dependent esophageal temperature rise has been reported. In the TESO-PFA registry intraluminal esophageal temperature (TESO) changes in a clinical setting are evaluated. METHODS: Consecutive symptomatic AF patients (62 years, 67% male, 61% paroxysmal AF, CHA2 DS2 Vasc Score 2) underwent first-time PFA and were prospectively enrolled into our registry. Eight pulse trains (2 kV/2.5 s, bipolar, biphasic, x4 basket/flower configuration each) were delivered to each pulmonary vein (PV). Two extra pulse trains per PV in flower configuration were added for wide antral circumferential ablation. Continuous intraluminal esophageal temperature (TESO) was monitored with a 12-pole temperature probe. RESULTS: Median TESO change was statistically significant and increased by 0.8 ± 0.6°C, p < .001. A TESO increase ≥ 1°C was observed in 10/43 (23%) patients. The highest TESO measured was 40.3°C. The largest TESO difference (∆TESO) was 3.7°C. All patients remained asymptomatic considering possible ETI. No atrio-esophageal fistula was reported on follow-up. CONCLUSION: A small but significant intraluminal esophageal temperature rise can be observed in most patients during PFA. TESO rise over 40°C is rare. The clinical implications of the observed findings need to be further evaluated.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophageal Fistula , Pulmonary Veins , Animals , Humans , Male , Female , Temperature , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Heart Rate , Esophageal Fistula/diagnosis , Esophageal Fistula/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/surgery , Treatment Outcome
6.
J Cardiovasc Electrophysiol ; 35(3): 547-556, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37855621

ABSTRACT

The QDOT MICRO™ Catheter is a novel open-irrigated contact force-sensing radiofrequency ablation catheter. It offers very high-power short-duration (vHPSD) ablation with 90 W for 4 s to improve safety and efficacy of catheter ablation procedures. Although the QDOT MICRO™ Catheter was mainly designed for pulmonary vein isolation (PVI) its versatility to treat atrial fibrillation (AF) and other types of arrhythmias was recently evaluated by the FAST and FURIOUS study series and other studies and will be presented in this article. Available study and registry data as well as case reports concerning utilization of the QDOT MICRO™ Catheter for the treatment of cardiac arrhythmias including AF, focal and macroreentry atrial tachycardia, typical atrial flutter by cavotricuspid isthmus block, premature ventricular contractions, and accessory pathways were reviewed and summarized. In summary, the QDOT MICRO™ Catheter showed safety and efficacy for PVI and is able to treat also other types of arrhythmias as is was recently evaluated by case reports and the FAST and FURIOUS studies.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Pulmonary Veins , Tachycardia, Supraventricular , Humans , Treatment Outcome , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Flutter/diagnosis , Atrial Flutter/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/surgery
7.
Herzschrittmacherther Elektrophysiol ; 34(4): 339-350, 2023 Dec.
Article in German | MEDLINE | ID: mdl-37917360

ABSTRACT

Lead extraction due to infection or lead dysfunction has become more important in recent years. Patients with high risk of severe and life-threatening complications should only undergo surgery in experienced centers where appropriate personnel and equipment are available. In this review, different techniques and methods to safely and successfully perform transvenous lead extraction are summarized.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Treatment Outcome , Device Removal/adverse effects , Device Removal/methods , Retrospective Studies
8.
Circ J ; 87(12): 1722-1726, 2023 11 24.
Article in English | MEDLINE | ID: mdl-37532529

ABSTRACT

BACKGROUND: Pulsed field ablation (PFA) is a non-thermal energy source with promising safety and efficacy advantages. We aimed to develop a convenient, safe, effective and fast method of pulmonary vein isolation (PVI) utilizing a penta-spline PFA catheter via a single femoral vein and a venous closure system.Methods and Results: Consecutive patients (n=50; mean age: 63.6±10.7 years, 38% female) presenting with AF (paroxysmal AF: 56%) underwent first-time PVI via PFA. A single ultrasound-guided femoral vein puncture and a single transseptal puncture were used. After PVI using the penta-spline PFA catheter, extra pulse trains were added to the posterior wall for wide antral circumferential ablation. A venous closure system was used and a Donati suture was performed. The pressure bandage was removed after 1 h. A total of 196 PVs were identified and isolated with PFA only. The mean procedural time was 27.4±6.6 min, and the mean dwelling time was 14.4±5.5 min. Time to ambulation was 3.3±3.1 h. No severe complications occurred. During a mean follow-up of 6.5±2.1 months, 41/50 patients (82%) remained in sinus rhythm. CONCLUSIONS: The combination of a single venous puncture, single transseptal puncture approach using PFA and vascular closure device resulted in a 100% rate of acute PVI and an extraordinarily fast procedure and time to ambulation. The rate of periprocedural complications was low.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Female , Middle Aged , Aged , Male , Pulmonary Veins/surgery , Treatment Outcome , Catheter Ablation/methods , Atrial Fibrillation/surgery , Catheters
9.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37589146

ABSTRACT

AIMS: Catheter ablation with a cryoballoon (CB) provides effective and durable pulmonary vein (PV) isolation (PVI) associated with encouraging clinical outcome data. The novel POLARx CB incorporates unique features, which may translate into improved safety, efficacy, and outcomes. The ICE-AGE-1 study aimed to assess the efficacy, safety, and 1-year clinical follow-up of the POLARx CB in comparison to the Arctic Front Advance Pro CB (AF-CB4). METHODS AND RESULTS: A total of 103 consecutive patients with paroxysmal or persistent atrial fibrillation (AF) who underwent POLARx-based PVI (POLARx group) were prospectively enrolled and were compared to 102 consecutive patients previously treated with the AF-CB4 (AF-CB4 group). The mean age was 68.7 ± 10.2 (POLARx) and 65.7 ± 12 (AF-CB4, P = 0.0551) years. A total of 412 (POLARx) and 404 (AF-CB4) PVs were identified. All PVs, except for one PV in the POLARx group, were successfully isolated. A significant difference regarding the mean minimal CB temperature reached using the POLARx CB (-56.1 ± 8.3°C) and AF-CB4 (-46.9 ± 10.1°C) was observed (P < 0.0001). Real-time PVI was visualized in 71% of PVs in the POLARx group and 46% of them in the AF-CB4 group (P < 0.001). The mean procedure time was comparable: 54.5 ± 17.1 min for POLARx and 59.4 ± 18.6 min for AF-CB4 (P = 0.0509). No differences were observed in terms of periprocedural complications. There were comparable rates in freedom of AF or atrial tachycardia recurrence after 12 months, beyond a 90-day long blanking period: 78.9% in the POLARx group vs. 77.2% in the AF-CB4 group (P = 0.804). CONCLUSION: The novel POLARx CB showed similar safety, efficacy, and 1-year recurrence-free survival rates compared to the AF-CB4. A higher rate of real-time electrical PV recordings and significantly lower balloon temperatures were observed using the POLARx as compared to AF-CB4.


Subject(s)
Catheter Ablation , Pulmonary Veins , Humans , Middle Aged , Aged , Infant , Pulmonary Veins/surgery , Prospective Studies , Catheter Ablation/adverse effects , Temperature
10.
Front Cardiovasc Med ; 10: 1217745, 2023.
Article in English | MEDLINE | ID: mdl-37435050

ABSTRACT

Background: Wide antral circumferential ablation (WACA) in comparison to ostial pulmonary vein (PV) isolation (PVI) has been attributed with improved rhythm outcome. We investigated the feasibility, lesion formation, and rhythm outcome of WACA-PVI in comparison to ostial-PVI using pulsed field ablation (PFA). Methods: Symptomatic atrial fibrillation (AF) patients (69 years, 67% male; 67% paroxysmal AF) were prospectively enrolled into our single-center registry and underwent first-time ostial-PFA or WACA-PFA, N = 15 each. In all patients, eight pulse trains (2 kV/2.5 s, bipolar, biphasic, 4× basket/flower configuration each) were delivered to each PV. In WACA-PFA, two extra pulse trains in a flower configuration were added to the anterior and posterior antrum of the PVs. For comparison of PFA lesion size, pre- and post-ablation left atrial (LA) voltage maps were acquired using a multipolar spiral catheter together with a three-dimensional electroanatomic mapping system. Results: WACA-PFA resulted in a significant larger lesion formation than ostial-PFA (45.5 vs. 35.1 cm2, p = 0.001) with bilateral overlapping butterfly shape-like lesions and concomitant posterior LA wall isolation in 73% of patients. This was not associated with increased procedure time, sedation dosage, or exposure to radiation. One-year freedom from AF recurrence was numerically higher after WACA-PFA than ostial-PFA (94% vs. 87%) but not statistically significant (p = 0.68). No organized atrial tachycardias (ATs) were observed. Ostial-PFA patients more often underwent re-ablation due to recurrent AF episodes. Conclusion: WACA-PFA is feasible and resulted in significantly wider lesion sets than ostial-PFA. Concomitant posterior LA wall isolation occurred as an epiphenomenon in the majority of patients. The WACA approach was associated with neither increased procedure and fluoroscopy times nor statistically significant differences in 1-year rhythm outcome. ATs were absent.

11.
Herzschrittmacherther Elektrophysiol ; 34(3): 187-192, 2023 Sep.
Article in German | MEDLINE | ID: mdl-37450012

ABSTRACT

Patients with statutory health insurance in Germany have the right to obtain a second opinion at the expense of their health insurance in addition to that of their primary practitioner before certain procedures are carried out. This gives rise to various legal obligations and questions on the part of both the practitioner and the second opinion provider. This article outlines, based on the legal situation, which obligations exist for both practitioners and second opinion providers, and who is suitable to provide a second opinion. Focus is placed on informing patients about the possibility of obtaining a second opinion. On the other hand, it explains which requirements second opinion providers have to fulfill and which duties are incumbent on them.


Subject(s)
Informed Consent , Referral and Consultation , Humans , Electrophysiology , Germany
12.
Herzschrittmacherther Elektrophysiol ; 34(3): 250-255, 2023 Sep.
Article in German | MEDLINE | ID: mdl-37460626

ABSTRACT

Various venous access routes in the region of the clavicle are available for cardiac device treatment. After many years of choosing access via the subclavian vein, current data explicitly show that lateral approaches such as preparation of the cephalic vein or puncture of the axillary vein are clearly superior in terms of probe durability and risk of complications. This article describes the preparation and performance of the various access techniques and is intended to provide a practical guide for the work in cardiac pacemaker operations. This work continues a series of articles designed for advanced training in specialized rhythmology.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Treatment Outcome , Subclavian Vein , Axillary Vein
14.
J Cardiovasc Electrophysiol ; 34(4): 833-840, 2023 04.
Article in English | MEDLINE | ID: mdl-36786515

ABSTRACT

INTRODUCTION: Pulmonary vein isolation (PVI) is well established as a primary treatment for atrial fibrillation (AF). The POLAR ICE study was designed to collect prospective real world data on the safety and effectiveness of the POLARxTM cryoballoon for PVI to treat paroxysmal AF. METHODS: POLAR ICE, a prospective, non-randomized, multicenter (international) registry (NCT04250714), enrolled 399 patients across 19 European centers. Procedural characteristics, such as time to isolation, cryoablations per pulmonary vein (PV), balloon nadir temperature, and occlusion grade were recorded. PVI was confirmed with entrance block testing. RESULTS: Data on 372 de novo PVI procedures (n = 2190 ablations) were collected. Complete PVI was achieved in 96.8% of PVs. Procedure and fluoroscopy times were 68.2 ± 24.6 and 15.6 ± 9.6 min, respectively. Left atrial dwell time was 46.6 ± 18.3 min. Grade 3 or 4 occlusion was achieved in 98.2% of PVs reported and 71.2% of PVs isolation required only a single cryoablation. Of 2190 cryoapplications, 83% had a duration of at least 120 s; nadir temperature of these ablations averaged -56.3 ± 6.5°C. There were 6 phrenic nerve palsy events, 2 of which resolved within 3 months of the procedure. CONCLUSION: This real-world usage data on a novel cryoballoon suggests this device is effective, safe, and relatively fast in centers with cryoballoon experience. These data are comparable to prior POLARx reports and in keeping with reported data on other cryoballoons. Future studies should examine the long-term outcomes and the relationship between biophysical parameters and outcomes for this novel cryoballoon.


Subject(s)
Atrial Fibrillation , Humans , Atrial Fibrillation/surgery , Prospective Studies , Treatment Outcome , Heart Atria , Fluoroscopy
15.
Catheter Cardiovasc Interv ; 101(3): 610-619, 2023 02.
Article in English | MEDLINE | ID: mdl-36682074

ABSTRACT

BACKGROUND: Left atrial appendage closure (LAAC) has emerged as an alternative to oral anticoagulation (OAC) for stroke prevention in patients with atrial fibrillation (AF). OAC treatment has been proven feasible in mild-to-moderate chronic kidney disease (CKD). In contrast, the optimal antithrombotic management of AF patients with end-stage renal disease (ESRD) is unknown and LAAC has not been proven in these patients in prospective randomized clinical trials. OBJECTIVES: The objective of this study is to evaluate safety and efficacy of LAAC in patients with ESRD. METHODS: Patients undergoing LAAC were collected in a German multicenter real-world observational registry. A composite endpoint consisting of the occurrence of ischemic stroke/transient ischemic attack, systemic embolism, and/or major clinical bleeding was assessed. Patients with ESRD were compared with propensity score-matched patients without severe CKD. ESRD was defined as a glomerular filtration rate < 15 ml/min/1.73 m2 or chronic hemodialysis treatment. RESULTS: A total of 604 patients were analyzed, including 57 with ESRD and 57 propensity-matched patients. Overall, 596 endocardial and 8 epicardial LAAC procedures were performed. Frequency of major complications was 7.0% (42/604 patients) in the overall cohort, 8.8% (5/57 patients) in patients with ESRD, and 10.5% (6/57 patients) in matched controls (p = 0.75). The estimated event-free survival of the combined endpoint after 500 days was 90.7 ± 4.5% in patients with ESRD and 90.2 ± 5.5% in matched controls (p = 0.33). CONCLUSIONS: LAAC had comparable procedural safety and clinical efficacy in patients with ESRD and patients without severe CKD.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Kidney Failure, Chronic , Renal Insufficiency, Chronic , Stroke , Humans , Stroke/etiology , Stroke/prevention & control , Treatment Outcome , Atrial Appendage/diagnostic imaging , Prospective Studies , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Kidney Failure, Chronic/complications , Kidney Failure, Chronic/diagnosis , Kidney Failure, Chronic/therapy , Renal Insufficiency, Chronic/complications , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/therapy , Renal Dialysis/adverse effects , Registries , Anticoagulants/adverse effects
16.
BMC Cardiovasc Disord ; 23(1): 8, 2023 01 09.
Article in English | MEDLINE | ID: mdl-36624380

ABSTRACT

BACKGROUND: Pulmonary vein isolation (PVI) is recommended to treat paroxysmal and persistent atrial fibrillation (AF). This analysis aimed to assess the hospital efficiency of single-shot cryoballoon ablation (CBA) and point-by-point radiofrequency ablation (RFA). METHODS: The discrete event simulation used PVI procedure times from the FREEZE Cohort study to establish the electrophysiology (EP) lab occupancy time. 1000 EP lab days were simulated according to an illustrative German hospital, including 3 PVI cases per day using CBA at one site and RFA at the other. RESULTS: The analysis included 1560 CBA patients and 1344 RFA patients from the FREEZE Cohort. Some baseline patients' characteristics were different between groups (age, AF type, and some concomitant diseases), without being statistically associated to ablation procedure time. Mean procedure time was 122.2 ± 39.4 min for CBA and 160.3 ± 53.5 min for RFA (p < 0.0001). RFA was associated with a more than five-fold increase of cumulative overtime compared to CBA over the simulated period (1285 h with RFA and 253 h with CBA). 70.7% of RFA lab days included overtime versus 25.7% for CBA. CBA was associated with more days with an additional hour at the end of the EP lab shift compared to RFA (47.8% vs 11.5% days with one hour left, respectively). CONCLUSION: CBA is faster and more predictable than point-by-point RFA, and enables improvements in EP lab efficiency, including: fewer cumulative overtime hours, more days where overtime is avoided and more days with remaining time for the staff or for any EP lab usage. Clinical trial registration NCT01360008 (first registration 25/05/2011).


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Cohort Studies , Cryosurgery/adverse effects , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/surgery , Electrophysiology , Treatment Outcome , Recurrence
17.
Europace ; 25(3): 880-888, 2023 03 30.
Article in English | MEDLINE | ID: mdl-36546582

ABSTRACT

AIMS: The very high-power short-duration (vHP-SD) radiofrequency (RF) ablation concept of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective, and faster procedures. Utilizing conventional ablation, the 'close protocol' has been verified. Since lesion formation of vHP-SD ablation creates wider but shallower lesions we adapted the close protocol to an individualized and tighter 'very-close protocol' of 3-4 mm of inter-lesion distance (ILD) at the anterior and 5-6 mm at the posterior aspect of the left atrium using vHP-SD only. Here, we evaluated the safety and efficacy of vHP-SD ablation for PVI utilizing a very-close protocol in comparison with standard ablation. METHODS AND RESULTS: A total of 50 consecutive patients with symptomatic AF were treated with a very-close protocol utilizing vHP-SD (vHP-SD group). The data were compared with 50 consecutive patients treated by the ablation-index-guided strategy (control group). The mean RF time was 352 ± 81 s (vHP-SD) and 1657 ± 570 s (control, P < 0.0001), and the mean procedure duration was 59 ± 13 (vHP-SD) and 101 ± 38 (control, P < 0.0001). The first-pass isolation rate was 74% (vHP-SD) and 76% (control, P = 0.817). Severe adverse events were reported in 1 (2%, vHP-SD) and 3 (6%, control) patients (P = 0.307). A 12-month recurrence-free survival was 78% (vHP-SD) and 64% (control, P = 0.142). PVI durability assessed during redo-procedures was 75% (vHP-SD) vs. 33% (control, P < 0.001). CONCLUSIONS: PVI solely utilizing vHP-SD via a very-close protocol provides safe and effective procedures with a high rate of first-pass isolations. The procedure duration and ablation time were remarkably low. A 12-month follow-up and PVI durability are promising.


Subject(s)
Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Atria , Pulmonary Veins/surgery , Treatment Outcome
18.
J Clin Med ; 11(23)2022 Nov 25.
Article in English | MEDLINE | ID: mdl-36498531

ABSTRACT

Aims/Objectives: Patients with bleeding disorders are a rare and complex population in catheter ablation (CA) procedures. The most common types of bleeding disorders are von Willebrand disease (VWD) and hemophilia A (HA). Patients with VWD or HA tend to have a higher risk of bleeding complications compared to other patients. There is a lack of data concerning peri- and postinterventional coagulation treatment. We sought to assess the optimal management of patients with VWD and HA referred for catheter ablation procedures. Methods and Results: In this study, we analyzed patients with VWD or HA undergoing CA procedures at two centers in Germany and Switzerland between 2016 and 2021. Clotting factors were administered in conjunction with hemostaseological recommendations. CA was performed as per the institutional standard. During the procedure, unfractionated heparin (UFH) was given intravenously with respect to the activated clotting time (ACT). Primary endpoints included the feasibility of the procedure, bleeding complications, and thromboembolic events during the procedure. Secondary endpoints included bleeding complications and thromboembolic events up to one year after catheter ablation. A total of seven patients (three VWD Type I, one VWD Type IIa, three HA) underwent 10 catheter ablation procedures (pulmonary vein isolation (PVI): two × radiofrequency (RF), one × laser balloon (LB), one × cryoballoon (CB); PVI + cavotricuspid isthmus (CTI): one × RF; PVI + left atrial appendage isolation (LAAI): one × RF; Premature ventricular contraction (PVC): three × RF; Atrioventricular nodal reentrant tachycardia (AVNRT): one × RF). VWD patients received 2000−3000 IE Wilate i.v. 30 to 45 min prior to ablation. Patients with HA received 2000−3000 IE factor VIII before the procedure. All patients undergoing PVI received UFH (cumulative dose 9000−18,000 IE) with a target ACT of >300 s. All patients after PVI were started on oral anticoagulation (OAC) 12 h after ablation. Two patients received aspirin (acetylsalicylic acid; ASA) for 4 weeks after the ablation of left-sided PVCs. No anticoagulation was prescribed after slow pathway modulation in a case with AVNRT. No bleeding complications or thromboembolic events were reported. During a follow-up of one year, one case of gastrointestinal bleeding occurred following OAC withdrawal after LAA occlusion. Conclusions: After the substitution of clotting factors, catheter ablation in patients with VWD and HA seems to be safe and feasible.

19.
Europace ; 24(12): 1917-1925, 2022 Dec 09.
Article in English | MEDLINE | ID: mdl-36026521

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) either by balloon devices or radiofrequency forms the cornerstone of invasive atrial fibrillation (AF) treatment. Although equally effective cryoballoon (CB)-based PVI offers shorter procedure duration and a better safety profile. Beside the worldwide established Arctic Front Advance system, a novel CB device, POLARx, was recently introduced. This CB incorporates unique features, which may translate into improved efficacy and safety. However, multicentre assessment of periprocedural efficacy and safety is lacking up to date. METHODS AND RESULTS: A total of 317 patients with paroxysmal or persistent AF were included and underwent POLARx CB-based PVI in 6 centres from Germany and Italy. Acute efficacy and safety were assessed in this prospective multicenter observational study. In 317 patients [mean age: 64 ± 12 years, 209 of 317 (66%) paroxysmal AF], a total of 1256 pulmonary veins (PVs) were identified and 1252 (99,7%) PVs were successfully isolated utilizing mainly the short tip POLARx CB (82%). The mean minimal CB temperature was -57.9 ± 7°C. Real-time PVI was registered in 72% of PVs. The rate of serious adverse events was 6.0% which was significantly reduced after a learning curve of 25 cases (9.3% vs. 3.0%, P = 0.018). The rate of recurrence-free survival after mean follow-up of 226 ± 115 days including a 90-day blanking period was 86.1%. CONCLUSION: In this large multicentre assessment, the novel POLARx CB shows a promising efficacy and safety profile after a short learning curve.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Middle Aged , Aged , Pulmonary Veins/surgery , Catheter Ablation/methods , Prospective Studies , Treatment Outcome , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology
20.
J Cardiovasc Electrophysiol ; 33(9): 2003-2012, 2022 09.
Article in English | MEDLINE | ID: mdl-35761754

ABSTRACT

INTRODUCTION: Arrhythmia recurrence after pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) is common and often linked to pulmonary vein reconnection. In patients with arrhythmia recurrences despite durable PVI the optimal ablation approach is unclear. The purpose of the present study was to analyze efficacy of extended ablation maneuvers in these patients and predictors of procedural success. METHODS: Consecutive patients with durable PVI undergoing repeat ablation procedures were prospectively enrolled. Patients underwent substrate modification with creation of linear lesions and/or mechanism-specific atrial tachycardia (AT) ablation. Three dimensional-mapping images were analyzed for the presence of left atrial (LA) low-voltage areas according to published scoring systems. RESULTS: Seventy-four patients were analyzed. Mode of recurrence after durable PVI was AF in 27 patients (36.5%) and AT in 47 patients (63.5%). Linear lesion ablation was performed in 60 patients (81.1%). Twenty-four patients (32.4%) were treated for focal AT mechanisms. Mean follow-up was 565 ± 342 days. Estimated arrhythmia-free survival after 24 months was significantly higher in patients with AT than in patients with AF as mode of recurrence after durable PVI (42.9 ± 8.2% vs. 24.7 ± 8.5%, p = .023) and in patients without compared to patients with marked LA low-voltage areas (40.5 ± 9.2% vs. 22.8 ± 8.5%, p = .041). The mode of recurrence after durable PVI was the only independent predictor of further arrhythmia recurrence after repeat ablation. CONCLUSION: Arrhythmia-free survival following repeat ablation procedures in patients with durable PVI highly depends on mode of arrhythmia recurrence and the presence of LA low-voltage areas.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Humans , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...