Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 128
Filter
1.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38647070

ABSTRACT

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Suture Techniques , Humans , Atrial Fibrillation/surgery , Female , Male , Middle Aged , Catheter Ablation/adverse effects , Catheter Ablation/methods , Prospective Studies , Pulmonary Veins/surgery , Suture Techniques/adverse effects , Aged , Treatment Outcome , Germany , Time Factors , Vascular Closure Devices , Early Ambulation , Hemostatic Techniques/instrumentation
2.
Clin Res Cardiol ; 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38619577

ABSTRACT

BACKGROUND: Catheter ablation of atrial fibrillation and atrial flutter is routinely performed in patients with implantable devices. The aim of the present study was to assess success rates and potential complications in a large registry cohort of patients with cardiac pacemakers. METHODS AND RESULTS: The German Ablation Registry is a nationwide, prospective registry with a 1-year follow-up investigating patients who underwent catheter ablation of supraventricular arrhythmias in 51 German centers. The present analysis focussed on the presence of cardiac pacemakers in 591 patients undergoing catheter ablation of atrial fibrillation or atrial flutter. These were compared to 7393 patients without a pacemaker. Patients with pacemakers were significantly older and presented more comorbidities like diabetes, renal failure, cardiovascular disease, or previous stroke. One-year mortality (2.4% vs. 1.3%, p = 0.022) and a combined endpoint of death, myocardial infarction, and stroke (3.6% vs. 2.1%, p = 0.014) were significantly elevated in patients with pacemakers. Re-hospitalization was also more common in patients with a pacemaker (53.3% vs. 45.0%, p < 0.01). After adjustment for important comorbidities, pre-existing pacemaker systems did not show any negative effect. Procedural success was reported in 98.8% vs. 98.4% (p = 0.93). Device-related complications were only observed in 0.4% of patients with pacemakers. CONCLUSION: Patients with pacemaker systems undergoing catheter ablation of atrial fibrillation or atrial flutter demonstrate an increased risk of death, cardiovascular events, and re-hospitalization. This observation can be largely attributed to an older patient population and an increased rate of comorbidities.

3.
Eur Heart J Case Rep ; 8(3): ytae113, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38487587

ABSTRACT

Background: Despite modern techniques for ablation of ventricular tachycardia (VT), the procedure faces challenges such as deep intramural substrates or inaccessibility of the pericardial space. We aim to present a case of successful surgical treatment of a patient with drug-refractory VT, an apical aneurysm, large left ventricular (LV) thrombus, and recurrent implantable cardioverter defibrillator (ICD) shocks following failed epicardial catheter ablation. Case summary: A 67-year-old male with a history of ischaemic cardiomyopathy was brought to the emergency room after a syncope because of VT. The VT was terminated by an external cardioversion prior to admission. The ICD interrogation showed an episode of sustained monomorphic VT with eight appropriate but mostly ineffective ICD shocks. An echocardiogram revealed an apical aneurysm with a thrombus. Anticoagulation and antiarrhythmic drug therapy were initiated. Days later, the patient suffered recurrent episodes of sustained VTs, refractory to pharmacological therapy, and epicardial ablation; therefore, following aneurysmectomy and thrombus removal, a reconstruction of the LV and surgical endocardial cryoablation were performed. In addition, ICD extraction was done due to recurrent bacteraemia with Staphylococcus aureus. A subcutaneous ICD was later implanted. After surgery, the patient remained free of any VT episodes during 44 months of follow-up. Conclusion: Combined surgical ventricular reconstruction and intraoperative cryoablation may be considered as an alternative, highly effective therapy in patients with drug-refractory VTs in the setting of a LV thrombus.

4.
Herzschrittmacherther Elektrophysiol ; 35(Suppl 1): 102-109, 2024 Mar.
Article in German | MEDLINE | ID: mdl-38407580

ABSTRACT

This article focuses on ventricular arrythmias without evidence for structural heart disease. There are many different reasons for this type of arrythmia and there is still a gap of knowledge. Starting with the first description of this disease, we present the diagnosis and management with medication, and finally catheter ablation procedures from the beginning to how it is currently treated and how it possibly will be treated in the near future.


Subject(s)
Catheter Ablation , Heart Diseases , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Arrhythmias, Cardiac/surgery
5.
Article in English | MEDLINE | ID: mdl-38345706

ABSTRACT

BACKGROUND: Persistent left superior vena cava (PLSVC) is a rare venous anomaly, affecting 0.3-0.5% of the general population. Cardiac resynchronization therapy (CRT) implantation in patients with PLSVC is challenging due to a complex anatomy. Moreover, data on CRT implantation in this patient population is scarce. Our aim was to report a series of patients with PLSVC and CRT implantation focusing on challenges and pitfalls. METHODS: Electronic medical databases on patients with CRT implantation at the University Heart Centers in Zurich, Switzerland, and Lübeck, Germany, were screened for individuals with a PLSVC. Clinical and demographic characteristics as well as procedural data were reported in all patients. RESULTS: This study presents six cases with a median age of 66 years. CRT implantation was successful in five patients, leading to a reduced QRS duration and improved left ventricular ejection fraction. Atrial fibrillation, ischemic cardiomyopathy, valvular heart disease, and dilated cardiomyopathy were observed in this group as underlying conditions. Specialized tools, such as active fixation left ventricular leads, were utilized. One patient experienced major complications. CONCLUSIONS: This case series shows that although challenging, conventional endovascular CRT implantation is feasible in PLSVC patients. Specialized tools for visualization and fixation may help. Our experiences highlight the importance of preprocedural evaluation of the anatomy and precise intervention planning.

7.
Sleep Breath ; 2023 Nov 06.
Article in English | MEDLINE | ID: mdl-37926800

ABSTRACT

BACKGROUND: Patients with obstructive or central sleep apnea are primarily treated with positive airway pressure treatment. There are novel implantable options targeting either obstructive sleep apnea using hypoglossal nerve stimulation (HNS) or central sleep apnea using phrenic nerve stimulation (PNS). METHODS: Patients with sleep apnea were implanted with both HNS and PNS devices, and their response to each therapy was monitored using home sleep tests as well as Epworth Sleepiness scale (ESS). RESULTS: We evaluated our concurrent neurostimulation approach in two patients. Both patients were implanted with two neuromodulation devices: The first case suffered from treatment emergent central sleep apnea after HNS activation for primarily obstructive sleep apnea (apnea-hypopnea index/AHI 54/h). The central portion resolved under PNS (AHI 23.7/h). The second case suffered from predominantly central sleep apnea (AHI 82/h). Here, the PNS device was implanted first, resulting in a subsequent reduction of the central portion. The residual obstructive sleep apnea was addressed using HNS (AHI 5.4/h). No interaction between the HNS and PNS systems was noticed in either of the two patients. CONCLUSIONS: In selected cases, a concurrent treatment with hypoglossal and phrenic nerve stimulation may lead to improvement of sleep apnea and patient satisfaction in a safe manner.

9.
Strahlenther Onkol ; 199(7): 621-630, 2023 07.
Article in English | MEDLINE | ID: mdl-37285038

ABSTRACT

BACKGROUND: Single-session cardiac stereotactic radiation therapy (SBRT) has demonstrated promising results for patients with refractory ventricular tachycardia (VT). However, the full safety profile of this novel treatment remains unknown and very limited data from prospective clinical multicenter trials are available. METHODS: The prospective multicenter multiplatform RAVENTA (radiosurgery for ventricular tachycardia) study assesses high-precision image-guided cardiac SBRT with 25 Gy delivered to the VT substrate determined by high-definition endocardial and/or epicardial electrophysiological mapping in patients with refractory VT ineligible for catheter ablation and an implanted cardioverter defibrillator (ICD). Primary endpoint is the feasibility of full-dose application and procedural safety (defined as an incidence of serious [grade ≥ 3] treatment-related complications ≤ 5% within 30 days after therapy). Secondary endpoints comprise VT burden, ICD interventions, treatment-related toxicity, and quality of life. We present the results of a protocol-defined interim analysis. RESULTS: Between 10/2019 and 12/2021, a total of five patients were included at three university medical centers. In all cases, the treatment was carried out without complications. There were no serious potentially treatment-related adverse events and no deterioration of left ventricular ejection fraction upon echocardiography. Three patients had a decrease in VT episodes during follow-up. One patient underwent subsequent catheter ablation for a new VT with different morphology. One patient with local VT recurrence died 6 weeks after treatment in cardiogenic shock. CONCLUSION: The interim analysis of the RAVENTA trial demonstrates early initial feasibility of this new treatment without serious complications within 30 days after treatment in five patients. Recruitment will continue as planned and the study has been expanded to further university medical centers. TRIAL REGISTRATION NUMBER: NCT03867747 (clinicaltrials.gov). Registered March 8, 2019. Study start: October 1, 2019.


Subject(s)
Radiosurgery , Tachycardia, Ventricular , Humans , Radiosurgery/methods , Stroke Volume , Prospective Studies , Quality of Life , Feasibility Studies , Ventricular Function, Left , Tachycardia, Ventricular/radiotherapy , Tachycardia, Ventricular/surgery , Treatment Outcome
10.
Herz ; 48(3): 212-217, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37277617

ABSTRACT

Arrhythmic manifestations of COVID-19 include atrial arrhythmias such as atrial fibrillation or atrial flutter, sinus node dysfunction, atrioventricular conduction abnormalities, ventricular tachyarrhythmias, sudden cardiac arrest, and cardiovascular dysautonomias including the so-called long COVID syndrome. Various pathophysiological mechanisms have been implicated, such as direct viral invasion, hypoxemia, local and systemic inflammation, changes in ion channel physiology, immune activation, and autonomic dysregulation. The development of atrial or ventricular arrhythmias in hospitalized COVID-19 patients has been shown to portend a higher risk of in-hospital death. Management of these arrhythmias should be based on published evidence-based guidelines, with special consideration of the acuity of COVID-19 infection, concomitant use of antimicrobial and anti-inflammatory drugs, and the transient nature of some rhythm disorders. In view of new SARS-CoV­2 variants that may evolve, the development and use of newer antiviral and immunomodulator drugs, and the increasing adoption of vaccination, clinicians must remain vigilant for other arrhythmic manifestations that may occur in association with this novel but potentially deadly disease.


Subject(s)
Atrial Fibrillation , COVID-19 , Humans , Incidence , Post-Acute COVID-19 Syndrome , Hospital Mortality , SARS-CoV-2 , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control
11.
Eur Heart J ; 44(27): 2458-2469, 2023 Jul 14.
Article in English | MEDLINE | ID: mdl-37062040

ABSTRACT

AIMS: Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management, and outcome are sparse. METHODS AND RESULTS: This international multicentre registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553 729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed, at 214 centres in 35 countries. In 78 centres 138 patients [0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (P < 0.0001)] were diagnosed with an oesophageal fistula. Peri-procedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8% and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) [odds ratio 7.463 (2.414, 23.072) P < 0.001]. CONCLUSION: Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophageal Fistula , Humans , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnosis , Treatment Outcome , Incidence , Risk Factors , Esophageal Fistula/epidemiology , Esophageal Fistula/etiology , Esophageal Fistula/diagnosis , Prognosis , Catheter Ablation/adverse effects , Catheter Ablation/methods
14.
Pacing Clin Electrophysiol ; 46(2): 161-168, 2023 02.
Article in English | MEDLINE | ID: mdl-36588339

ABSTRACT

BACKGROUND: Catheter ablation is an effective treatment for atrial fibrillation (AF,) but arrhythmia recurrence occurs in a relevant number of patients. Mechanisms of late occurring arrhythmias after ablation procedures are not fully understood. We analyzed electrophysiological mechanisms of early and late arrhythmia recurrences in patients who underwent radiofrequency-based catheter ablation of AF. METHODS AND RESULTS: Consecutive patients who underwent repeat ablation procedures after initial pulmonary vein isolation (PVI) for symptomatic arrhythmia recurrence were analyzed. A total of 110 consecutive patients who underwent catheter ablation for paroxysmal (79%) or persistent AF (21%) were included. Forty-seven patients suffered from early arrhythmia recurrence (group #1: 3-24 months), 29 patients from mid-term arrhythmia recurrences (group #2: 2-5 years), and 34 patients from late arrhythmia recurrences (group #3: > 5 years). Electrical PV reconnection was found in 98% in group #1, 72% in group #2 and 56% in group #3 (p < .001). Mode of arrhythmia recurrence was organized tachycardia in 25%, 28%, and 65% of patients in groups #1, #2, and #3 (p = .001), respectively. Patients with late arrhythmia recurrence had more pronounced left atrial low voltage as compared to patients with early arrhythmia recurrence based on two published scoring system. CONCLUSION: Electrical PV reconnection was found in the majority of patients with early AF recurrence after PVI. In patients with late arrhythmia recurrences this mechanism may play an inferior role, with many patients presenting without PV reconnection, but with LA structural alterations. Thus, early and late occurring arrhythmia recurrence after catheter ablation may be the same symptom of different diseases.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Recurrence , Heart Atria , Treatment Outcome , Catheter Ablation/methods
15.
Technol Health Care ; 31(2): 735-746, 2023.
Article in English | MEDLINE | ID: mdl-36442163

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is associated with significant morbidity and is predicted by atrial high rate events. The early detection of AF is paramount to timely interventions to reduce the morbidity of AF. The DX ICD system combined with Home Monitoring® allows for continuous atrial rhythm monitoring without the need for a dedicated atrial lead. OBJECTIVE: To establish the reaction to and timing of reactions to the detection of atrial high rate episodes (AHRE). METHODS: A prospective cohort of DX ICD systems was followed up and the response to AHREs was collected and evaluated. RESULTS: A total of 234 patients were enrolled; an AHRE ⩾ 6 min was detected in 13.7% of patients (n= 32) within a mean follow-up duration of 16 months. A high rate of oral anticoagulation (OAC) prescription was seen with the detection of AHREs in patients with a not-low risk CHA2DS2-VASc score. There was a delay in this prescription highlighting the potential to improve the timeliness of patient care in this group of patients. CONCLUSIONS: The DX ICD system provides rapid and ongoing atrial rhythm monitoring such that physicians are rapidly aware of AHRE without the need for a dedicated atrial lead, but local protocols are needed to improve the response time of anti-coagulation prescription.


Subject(s)
Atrial Fibrillation , Defibrillators, Implantable , Stroke , Humans , Atrial Fibrillation/therapy , Atrial Fibrillation/diagnosis , Prospective Studies , Stroke/complications , Risk Factors
17.
Europace ; 25(2): 374-381, 2023 02 16.
Article in English | MEDLINE | ID: mdl-36414239

ABSTRACT

AIMS: Cryoballoon (CB)-based pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). The most frequent complication during CB-based PVI is right-sided phrenic nerve injury (PNI) which is leading to premature abortion of the freeze cycle. Here, we analysed reconnection rates after CB-based PVI and PNI in a large-scale population during repeat procedures. METHODS AND RESULTS: In the YETI registry, a total of 17 356 patients underwent CB-based PVI in 33 centres, and 731 (4.2%) patients experienced PNI. A total of 111/731 (15.2%) patients received a repeat procedure for treatment of recurrent AF. In 94/111 (84.7%) patients data on repeat procedures were available. A total of 89/94 (94.7%) index pulmonary veins (PVs) have been isolated during the initial PVI. During repeat procedures, 22 (24.7%) of initially isolated index PVs showed reconnection. The use of a double stop technique did non influence the PV reconnection rate (P = 0.464). The time to PNI was 140.5 ± 45.1 s in patients with persistent PVI and 133.5 ± 53.8 s in patients with reconnection (P = 0.559). No differences were noted between the two populations in terms of CB temperature at the time of PNI (P = 0.362). The only parameter associated with isolation durability was CB temperature after 30 s of freezing. The PV reconnection did not influence the time to AF recurrence. CONCLUSION: In patients with cryoballon application abortion due to PNI, a high rate of persistent PVI rate was found at repeat procedures. Our data may help to identify the optimal dosing protocol in CB-based PVI procedures. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03645577?term=YETI&cntry=DE&draw=2&rank=1 ClinicalTrials.gov Identifier: NCT03645577.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Catheter Ablation/adverse effects , Cryosurgery/adverse effects , Cryosurgery/methods , Phrenic Nerve , Pulmonary Veins/surgery , Recurrence , Time Factors , Treatment Outcome
18.
J Arrhythm ; 38(6): 1009-1016, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36524033

ABSTRACT

Background: Pulmonary vein stenosis (PVS) is a severe complication of atrial fibrillation (AF) ablation resulting in narrowing of affected pulmonary veins (PVs). Interventional treatment consists of angioplasty with or without PV stenting. The optimal postprocedural antithrombotic therapy is not known. Study aims: To investigate the impact of antithrombotic medical therapy on recurrence of PVS after PV angioplasty. Methods: A retrospective study of patients undergoing PV angioplasty with or without stent implantation in two German centers was performed. Postinterventional antithrombotic therapy consisted of either dual antiplatelet therapy (DAPT) or a combination of oral anticoagulation with single or dual antiplatelet therapy for 3-12 months after intervention. Angiographic follow-up was recommended 3, 6, and 12 months after intervention and in case of symptom recurrence. Results: Thirty patients underwent treatment of 42 PVS. After intervention, twenty-eight patients received triple therapy and 14 patients received dual therapy/DAPT; restenosis occurred in 5/22 (22.7%) patients with triple therapy and 8/14 (57.1%) patients with dual therapy/DAPT PV (p = .001). Estimated freedom from PV restenosis after 500 days was 18.8 ± 15.8% (dual therapy/DAPT) and 76.2 ± 10.5% (triple therapy) (p = .003). Univariate regression analysis revealed postprocedural medication as a significant risk factor for restenosis (p = .019). No bleeding events occurred regardless of applied antithrombotic therapy. Conclusion: Triple antithrombotic therapy after PV angioplasty is associated with less frequent restenosis as compared to dual antiplatelet therapy or a combination of anticoagulation and single antiplatelet therapy. No severe bleeding events occurred in patients on triple therapy. These findings need to be confirmed in larger patient cohorts.

19.
Dtsch Med Wochenschr ; 147(22): 1469-1476, 2022 11.
Article in German | MEDLINE | ID: mdl-36318910

ABSTRACT

Abnormalities of the sinus node, atrial tissue, atrioventricular node tissue, and specialized conduction system can all contribute to bradycardia. For this reason, the diagnosis and treatment of bradycardia have become challenging. In order to further optimize the assessment and treatment of patients with bradycardia, new guidelines on cardiac pacemaker therapy and cardiac resynchronization therapy were published by the European Society of Cardiology (ESC) last year. These include new recommendations for diagnostics, dealing with reflex syncope and treatment algorithms for syncope and bundle branch block. The use of leadless pacemakers is being discussed in selected and especially multimorbid patients as an alternative to conventional transvenous pacemaker implantation. Conduction system pacing as a physiological form of stimulation was included in the guidelines for the first time.


Subject(s)
Bradycardia , Pacemaker, Artificial , Humans , Bradycardia/therapy , Cardiac Conduction System Disease/diagnosis , Cardiac Conduction System Disease/therapy , Bundle-Branch Block , Syncope/therapy , Cardiac Pacing, Artificial
20.
Herzschrittmacherther Elektrophysiol ; 33(4): 380-385, 2022 Dec.
Article in German | MEDLINE | ID: mdl-36239817

ABSTRACT

The pulmonary veins have been recognized as the primary source of atrial triggers, and their isolation has become the cornerstone for ablation of atrial fibrillation. However, long-term success rates after pulmonary vein isolation (PVI) are limited. Several promising new mapping techniques are described in this article, aiming to better understand the mechanisms underlying the induction and maintenance of atrial fibrillation and to develop more effective ablation strategies.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Treatment Outcome , Catheter Ablation/methods , Pulmonary Veins/surgery , Heart Atria , Recurrence
SELECTION OF CITATIONS
SEARCH DETAIL
...