Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
Cochlear Implants Int ; 20(1): 1-11, 2019 01.
Article in English | MEDLINE | ID: mdl-30126345

ABSTRACT

OBJECTIVE: To compare the benefits of a dexamethasone-eluting array for hearing preservation and cochlear histopathology in low trauma (soft-surgery) and high trauma models of cochlear implant surgery. METHODS: Adult guinea pigs were implanted with an intra-cochlear array using two different surgical procedures: either a soft-surgery approach or following generation of electrode insertion trauma (high trauma). Two methods of dexamethasone delivery were evaluated: elution from an electrode array alone, and elution from a cochlear implant electrode array in combination with a pre-operative systemic injection. All electrode arrays were implanted for a period of 4 weeks. Outcome measures at 4 weeks post-implantation included auditory brainstem response (ABR) thresholds, histological analysis of spiral ganglion neuron density, fibrotic tissue, new bone growth, and cochlear damage. RESULTS: Animals exposed to high surgical trauma showed greater hearing loss than those in the low trauma model, irrespective of the presence of dexamethasone. Whilst the area of intra-cochlear fibrotic tissue growth post-implantation was also independent of dexamethasone administration, new bone growth was significantly reduced in its presence. Our high trauma model effectively obliterated the organ of Corti and significantly reduced spiral ganglion neuron densities in the lower basal turn. This trauma-induced reduction in spiral ganglion neuron survival decreased with the inclusion of a dexamethasone-eluting array. A pre-operative systemic injection of dexamethasone did not significantly improve any outcome measures beyond those provided with a dexamethasone-eluting array alone. CONCLUSION: Dexamethasone-eluting intra-cochlear arrays may inhibit osteoneogenesis, and reduce spiral ganglion neuron loss following traumatic cochlear implantation.


Subject(s)
Cochlear Implantation/adverse effects , Cochlear Implants/adverse effects , Dexamethasone/administration & dosage , Glucocorticoids/administration & dosage , Hearing Loss/prevention & control , Postoperative Complications/prevention & control , Animals , Cochlea/drug effects , Cochlea/surgery , Cochlear Implantation/methods , Guinea Pigs , Hearing/drug effects , Hearing Loss/etiology , Spiral Ganglion/drug effects , Spiral Ganglion/surgery
2.
Cochlear Implants Int ; 15(5): 254-63, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24621150

ABSTRACT

OBJECTIVES: Cochlear implantation can result in trauma leading to increased tissue response and loss of residual hearing. A single intratympanic application of the corticosteroid dexamethasone is sometimes used clinically during surgery to combat the potential effect of trauma on residual hearing. This project looked at the safety and efficacy of dexamethasone eluted from an intracochlear array in vivo. METHODS: Three trials were conducted using normal hearing adult guinea pigs implanted with successive iterations of dexamethasone-eluting (DX1, DX2, and DX3) or non-eluting (control) intracochlear electrode arrays. The experimental period for each animal was 90 days during which hearing tests were performed at multiple time points. RESULTS: There was no significant difference between matched control array and dexamethasone array groups in terms of spiral ganglion neuron density, organ of Corti condition, or fibrosis and ossification. A cochleostomy seal was present in all implanted cochleae. There were no differences in the degree of hearing threshold shifts between DX1 and DX3 and their respective control arrays. Cochleae implanted with DX2 arrays showed less hearing loss and marginally better spiral ganglion neuron survival than their control array counterparts. Post-explant inspection of the DX2 and DX3 arrays revealed a difference in pore density following dexamethasone elution. CONCLUSION: The dexamethasone doses used were safe in the guinea pig cochlea. Dexamethasone did not inhibit formation of a cochleostomy seal. The level of hearing protection afforded by dexamethasone eluting from an intracochlear array may depend upon the degree of elution and level of trauma inflicted.


Subject(s)
Anti-Inflammatory Agents/administration & dosage , Cochlear Implantation/adverse effects , Cochlear Implants , Dexamethasone/administration & dosage , Hearing Loss/prevention & control , Animals , Auditory Threshold , Disease Models, Animal , Equipment Design , Evoked Potentials, Auditory, Brain Stem , Guinea Pigs , Hearing Loss/etiology , Hearing Loss/pathology , Organ of Corti/pathology , Spiral Ganglion/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...