Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Invest Ophthalmol Vis Sci ; 65(5): 39, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38787546

ABSTRACT

Purpose: Post-saccadic oscillations (PSOs) reflect movements of gaze that result from motion of the pupil and lens relative to the eyeball rather than eyeball rotations. Here, we analyzed the characteristics of PSOs in subjects with age-related macular degeneration (AMD), retinitis pigmentosa (RP), and normal vision (NV). Our aim was to assess the differences in PSOs between people with vision loss and healthy controls because PSOs affect retinal image stability after each saccade. Methods: Participants completed a horizontal saccade task and their gaze was measured using a pupil-based eye tracker. Oscillations occurring in the 80 to 200 ms post-saccadic period were described with a damped oscillation model. We compared the amplitude, decay time constant, and frequency of the PSOs for the three different groups. We also examined the correlation between these PSO parameters and the amplitude, peak velocity, and final deceleration of the preceding saccades. Results: Subjects with vision loss (AMD, n = 6, and RP, n = 5) had larger oscillation amplitudes, longer decay constants, and lower frequencies than subjects with NV (n = 7). The oscillation amplitudes increased with increases in saccade deceleration in all three groups. The other PSO parameters, however, did not show consistent correlations with either saccade amplitude or peak velocity. Conclusions: Post-saccadic fixation stability in AMD and RP is reduced due to abnormal PSOs. The differences with respect to NV are not due to differences in saccade kinematics, suggesting that anatomic and neuronal variations affect the suspension of the iris and the lens in the patients' eyes.


Subject(s)
Fixation, Ocular , Macular Degeneration , Pupil , Retinitis Pigmentosa , Saccades , Humans , Saccades/physiology , Retinitis Pigmentosa/physiopathology , Female , Male , Fixation, Ocular/physiology , Middle Aged , Macular Degeneration/physiopathology , Aged , Pupil/physiology , Lens, Crystalline/physiopathology , Adult , Visual Acuity/physiology
2.
Invest Ophthalmol Vis Sci ; 64(3): 1, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36857076

ABSTRACT

Purpose: Most eye-movement studies in patients with visual field defects have examined the strategies that patients use while exploring a visual scene, but they have not investigated saccade kinematics. In healthy vision, saccade trajectories follow the remarkably stereotyped "main sequence": saccade duration increases linearly with saccade amplitude; peak velocity also increases linearly for small amplitudes, but approaches a saturation limit for large amplitudes. Recent theories propose that these relationships reflect the brain's attempt to optimize vision when planning eye movements. Therefore, in patients with bilateral retinal damage, saccadic behavior might differ to optimize vision under the constraints imposed by the visual field defects. Methods: We compared saccadic behavior of patients with central vision loss, due to age-related macular degeneration (AMD), and patients with peripheral vision loss, due to retinitis pigmentosa (RP), to that of controls with normal vision (NV) using a horizontal saccade task. Results: Both patient groups demonstrated deficits in saccade reaction times and target localization behavior, as well as altered saccade kinematics. Saccades were generally slower and the shape of the velocity profiles were often atypical, especially in the patients with RP. In the patients with AMD, the changes were far less dramatic. For both groups, saccade kinematics were affected most when the target was in the subjects' blind field. Conclusions: We conclude that defects of the central and peripheral retina have distinct effects on the saccade main sequence, and that visual inputs play an important role in planning the kinematics of a saccade.


Subject(s)
Macular Degeneration , Retinal Diseases , Retinitis Pigmentosa , Humans , Saccades , Eye Movements , Scotoma
3.
Transl Vis Sci Technol ; 12(3): 20, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36943168

ABSTRACT

Purpose: Accurate mapping of phosphene locations from visual prostheses is vital to encode spatial information. This process may involve the subject pointing to evoked phosphene locations with their finger. Here, we demonstrate phosphene mapping for a retinal implant using eye movements and compare it with retinotopic electrode positions and previous results using conventional finger-based mapping. Methods: Three suprachoroidal retinal implant recipients (NCT03406416) indicated the spatial position of phosphenes. Electrodes were stimulated individually, and the subjects moved their finger (finger based) or their eyes (gaze based) to the perceived phosphene location. The distortion of the measured phosphene locations from the expected locations (retinotopic electrode locations) was characterized with Procrustes analysis. Results: The finger-based phosphene locations were compressed spatially relative to the expected locations all three subjects, but preserved the general retinotopic arrangement (scale factors ranged from 0.37 to 0.83). In two subjects, the gaze-based phosphene locations were similar to the expected locations (scale factors of 0.72 and 0.99). For the third subject, there was no apparent relationship between gaze-based phosphene locations and electrode locations (scale factor of 0.07). Conclusions: Gaze-based phosphene mapping was achievable in two of three tested retinal prosthesis subjects and their derived phosphene maps correlated well with the retinotopic electrode layout. A third subject could not produce a coherent gaze-based phosphene map, but this may have revealed that their phosphenes were indistinct spatially. Translational Relevance: Gaze-based phosphene mapping is a viable alternative to conventional finger-based mapping, but may not be suitable for all subjects.


Subject(s)
Eye Movements , Visual Prosthesis , Humans , Phosphenes , Vision Disorders , Retina/surgery
4.
Transl Vis Sci Technol ; 11(9): 4, 2022 09 01.
Article in English | MEDLINE | ID: mdl-36066322

ABSTRACT

Purpose: The electrode to retina (ER) distance is an important contributory factor to the safety and efficacy of a suprachoroidal retinal prosthesis. Measuring ER distance may be performed by different observers during multisite studies. The aim of this study was to assess the interobserver agreement in measuring ER distance. Methods: Three independent, trained observers measured ER distance from the center of each suprachoroidal electrode to the inner retinal pigment epithelium in spectral-domain optical coherence tomography (SD-OCT) B-scans. A total of 121 ER distance measurements from 77 B-scans collected over 5 months from one subject implanted with a second-generation 44-channel suprachoroidal retinal prosthesis (NCT03406416) were made by each observer. Results: ER distance ranged from 208 to 509 µm. Pearson's correlation coefficient (ρ) showed agreement of 0.99 (95% confidence interval [CI] = 0.98-0.99) in measuring ER for each pairwise comparison. The mean difference in ER distance between observers ranged from 2.4 to 6.4 µm with pairwise limits of agreement (95% CI) of ±20 µm (5.5% of mean). Intraclass correlation coefficient (ICC) showed agreement of 0.98 (95% CI = 0.97-0.99) between observers. Conclusions: There is high agreement in measuring ER distances for suprachoroidal retinal prostheses using our systematic approach between multiple, trained observers, supporting the use of a single observer for each image. Translational Relevance: High interobserver agreement outcomes indicate that multiple, trained observers can be used to take ER measurements across different images in suprachoroidal retinal prosthesis studies. This improves multisite study efficiency and gives confidence in interpreting results relating to the safety and efficacy of suprachoroidal retinal prostheses.


Subject(s)
Visual Prosthesis , Electrodes , Humans , Observer Variation , Retina/diagnostic imaging , Retina/surgery , Tomography, Optical Coherence/methods
5.
Transl Vis Sci Technol ; 11(6): 12, 2022 06 01.
Article in English | MEDLINE | ID: mdl-35696133

ABSTRACT

Purpose: To report the long-term observations of the electrode-tissue interface and perceptual stability in humans after chronic stimulation with a 44-channel suprachoroidal retinal implant. Methods: Four subjects (S1-4) with end-stage retinitis pigmentosa received the implant unilaterally (NCT03406416). Electrode impedances, electrode-retina distance (measured using optical coherence tomography imaging), and perceptual thresholds were monitored up to 181 weeks after implantation as the subjects used the prosthesis in the laboratory and in daily life. Stimulation charge density was limited to 32 µC/cm2 per phase. Results: Electrode impedances were stable longitudinally. The electrode-retina distances increased after surgery and then stabilized, and were well-described by an asymptotic exponential model. The stabilization of electrode-retina distances was variable between subjects, stabilizing after 45 weeks for S1, 63 weeks for S2, and 24 weeks for S3 (linear regression; Pgradient > 0.05). For S4, a statistically significant increase in electrode-retina distance persisted (P < 0.05), but by the study end point the rate of increase was clinically insignificant (exponential model: 0.33 µm/wk). Perceptual electrical thresholds were stable in one subject, decreased over time in two subjects (linear model; P < 0.05), and increased slightly in one subject but remained within the predefined charge limits (P = 0.02). Conclusions: Chronic stimulation with the suprachoroidal retinal prosthesis over 3 years resulted in stable impedances, small individual changes in perceptual electrical thresholds, and no clinically significant increase in electrode-retina distances after a period of settling after surgery. Translational Relevance: Chronic stimulation with the 44-channel suprachoroidal retinal implant with a charge density of up to 32 µC/cm2 per phase is suitable for long-term use in humans.


Subject(s)
Retinitis Pigmentosa , Visual Prosthesis , Electric Stimulation/methods , Humans , Microelectrodes , Retina/diagnostic imaging , Retina/surgery , Retinitis Pigmentosa/surgery
6.
Transl Vis Sci Technol ; 10(10): 12, 2021 08 12.
Article in English | MEDLINE | ID: mdl-34581770

ABSTRACT

Purpose: To report the initial safety and efficacy results of a second-generation (44-channel) suprachoroidal retinal prosthesis at 56 weeks after device activation. Methods: Four subjects, with advanced retinitis pigmentosa and bare-light perception only, enrolled in a phase II trial (NCT03406416). A 44-channel electrode array was implanted in a suprachoroidal pocket. Device stability, efficacy, and adverse events were investigated at 12-week intervals. Results: All four subjects were implanted successfully and there were no device-related serious adverse events. Color fundus photography indicated a mild postoperative subretinal hemorrhage in two recipients, which cleared spontaneously within 2 weeks. Optical coherence tomography confirmed device stability and position under the macula. Screen-based localization accuracy was significantly better for all subjects with device on versus device off. Two subjects were significantly better with the device on in a motion discrimination task at 7, 15, and 30°/s and in a spatial discrimination task at 0.033 cycles per degree. All subjects were more accurate with the device on than device off at walking toward a target on a modified door task, localizing and touching tabletop objects, and detecting obstacles in an obstacle avoidance task. A positive effect of the implant on subjects' daily lives was confirmed by an orientation and mobility assessor and subject self-report. Conclusions: These interim study data demonstrate that the suprachoroidal prosthesis is safe and provides significant improvements in functional vision, activities of daily living, and observer-rated quality of life. Translational Relevance: A suprachoroidal prosthesis can provide clinically useful artificial vision while maintaining a safe surgical profile.


Subject(s)
Retinitis Pigmentosa , Visual Prosthesis , Activities of Daily Living , Humans , Quality of Life , Vision, Ocular
7.
Transl Vis Sci Technol ; 10(10): 7, 2021 08 12.
Article in English | MEDLINE | ID: mdl-34383875

ABSTRACT

Purpose: In a clinical trial (NCT03406416) of a second-generation (44-channel) suprachoroidal retinal prosthesis implanted in subjects with late-stage retinitis pigmentosa (RP), we assessed performance in real-world functional visual tasks and emotional well-being. Methods: The Functional Low-Vision Observer Rated Assessment (FLORA) and Impact of Vision Impairment-Very Low Vision (IVI-VLV) instruments were administered to four subjects before implantation and after device fitting. The FLORA contains 13 self-reported and 35 observer-reported items ranked for ease of conducting task (impossible-easy, central tendency given as mode). The IVI-VLV instrument quantified the impact of low vision on daily activities and emotional well-being. Results: Three subjects completed the FLORA for two years after device fitting; the fourth subject ceased participation in the FLORA after fitting for reasons unrelated to the device. For all subjects at each post-fitting visit, the mode ease of task with device ON was better or equal to device OFF. Ease of task improved over the first six months with device ON, then remained stable. Subjects reported improvements in mobility, functional vision, and quality of life with device ON. The IVI-VLV suggested self-assessed vision-related quality of life was not impacted by device implantation or usage. Conclusions: Subjects demonstrated sustained improved ease of task scores with device ON compared to OFF, indicating the device has a positive impact in the real-world setting. Translational Relevance: Our suprachoroidal retinal prosthesis shows potential utility in everyday life, by enabling an increased environmental awareness and improving access to sensory information for people with end-stage RP.


Subject(s)
Retinitis Pigmentosa , Vision, Low , Visual Prosthesis , Humans , Quality of Life , Retinitis Pigmentosa/surgery , Vision, Ocular
8.
Transl Vis Sci Technol ; 9(13): 31, 2020 12.
Article in English | MEDLINE | ID: mdl-33384885

ABSTRACT

Purpose: To investigate oculomotor behavior in response to dynamic stimuli in retinal implant recipients. Methods: Three suprachoroidal retinal implant recipients performed a four-alternative forced-choice motion discrimination task over six sessions longitudinally. Stimuli were a single white bar ("moving bar") or a series of white bars ("moving grating") sweeping left, right, up, or down across a 42″ monitor. Performance was compared with normal video processing and scrambled video processing (randomized image-to-electrode mapping to disrupt spatiotemporal structure). Eye and head movement was monitored throughout the task. Results: Two subjects had diminished performance with scrambling, suggesting retinotopic discrimination was used in the normal condition and made smooth pursuit eye movements congruent to the moving bar stimulus direction. These two subjects also made stimulus-related eye movements resembling optokinetic reflex (OKR) for moving grating stimuli, but the movement was incongruent with stimulus direction. The third subject was less adept at the task, appeared primarily reliant on head position cues (head movements were congruent to stimulus direction), and did not exhibit retinotopic discrimination and associated eye movements. Conclusions: Our observation of smooth pursuit indicates residual functionality of cortical direction-selective circuits and implies a more naturalistic perception of motion than expected. A distorted OKR implies improper functionality of retinal direction-selective circuits, possibly due to retinal remodeling or the non-selective nature of the electrical stimulation. Translational Relevance: Retinal implant users can make naturalistic eye movements in response to moving stimuli, highlighting the potential for eye tracker feedback to improve perceptual localization and image stabilization in camera-based visual prostheses.


Subject(s)
Visual Prosthesis , Eye Movements , Head Movements , Humans , Photic Stimulation , Pursuit, Smooth
9.
Invest Ophthalmol Vis Sci ; 60(6): 2263-2273, 2019 05 01.
Article in English | MEDLINE | ID: mdl-31112611

ABSTRACT

Purpose: Peripheral visual field loss (PVFL) due to retinitis pigmentosa (RP) decreases saccades to areas of visual defect, leading to a habitually confined range of eye movement. We investigated the relative contributions of head and eye movement in RP patients and normal-sighted controls to determine whether this reduced eye movement is offset by increased head movement. Methods: Eye-head coordination was examined in 18 early-moderate RP patients, 4 late-stage RP patients, and 19 normal-sighted controls. Three metrics were extracted: the extent of eye, head, and total gaze (eye+head) movement while viewing a naturalistic scene; head gain, the ratio of head movement to total gaze movement during smooth pursuit; and the customary oculomotor range (COMR), the orbital range within which the eye is preferentially maintained during a pro-saccade task. Results: The late-stage RP group had minimal gaze movement and could not discern the naturalistic scene. Variance in head position in early-moderate RP was significantly greater than in controls, whereas variance in total gaze was similar. Head gain was greater in early-moderate RP than in controls, whereas COMR was smaller. Across groups, visual field extent was negatively correlated with head gain and positively correlated with COMR. Accounting for age effects, these results demonstrate increased head movement at the expense of eye movement in participants with PVFL. Conclusions: RP is associated with an increased propensity for head movement during gaze shifts, and the magnitude of this effect is dependent on the severity of visual field loss.


Subject(s)
Eye Movements/physiology , Head Movements/physiology , Retinitis Pigmentosa/physiopathology , Vision Disorders/physiopathology , Adult , Aged , Aged, 80 and over , Case-Control Studies , Female , Humans , Male , Middle Aged , Retinitis Pigmentosa/complications , Vision Disorders/etiology , Visual Fields/physiology
10.
Transl Vis Sci Technol ; 7(1): 2, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29321945

ABSTRACT

PURPOSE: Shifting the region-of-interest within the input image to compensate for gaze shifts ("gaze compensation") may improve hand-eye coordination in visual prostheses that incorporate an external camera. The present study investigated the effects of eye movement on hand-eye coordination under simulated prosthetic vision (SPV), and measured the coordination benefits of gaze compensation. METHODS: Seven healthy-sighted subjects performed a target localization-pointing task under SPV. Three conditions were tested, modeling: retinally stabilized phosphenes (uncompensated); gaze compensation; and no phosphene movement (center-fixed). The error in pointing was quantified for each condition. RESULTS: Gaze compensation yielded a significantly smaller pointing error than the uncompensated condition for six of seven subjects, and a similar or smaller pointing error than the center-fixed condition for all subjects (two-way ANOVA, P < 0.05). Pointing error eccentricity and gaze eccentricity were moderately correlated in the uncompensated condition (azimuth: R2 = 0.47; elevation: R2 = 0.51) but not in the gaze-compensated condition (azimuth: R2 = 0.01; elevation: R2 = 0.00). Increased variability in gaze at the time of pointing was correlated with greater reduction in pointing error in the center-fixed condition compared with the uncompensated condition (R2 = 0.64). CONCLUSIONS: Eccentric eye position impedes hand-eye coordination in SPV. While limiting eye eccentricity in uncompensated viewing can reduce errors, gaze compensation is effective in improving coordination for subjects unable to maintain fixation. TRANSLATIONAL RELEVANCE: The results highlight the present necessity for suppressing eye movement and support the use of gaze compensation to improve hand-eye coordination and localization performance in prosthetic vision.

11.
Invest Ophthalmol Vis Sci ; 58(10): 3962-3974, 2017 08 01.
Article in English | MEDLINE | ID: mdl-28793152

ABSTRACT

Purpose: Retinal prostheses provide vision to blind patients by eliciting phosphenes through electrical stimulation. This study explored whether character identification and image localization could be achieved through direct multiple-electrode stimulation with a suprachoroidal retinal prosthesis. Methods: Two of three retinitis pigmentosa patients implanted with a suprachoroidal electrode array were tested on three psychophysical tasks. Electrode patterns were stimulated to elicit perception of simple characters, following which percept localization was tested using either static or dynamic images. Eye tracking was used to assess the association between accuracy and eye movements. Results: In the character identification task, accuracy ranged from 2.7% to 93.3%, depending on the patient and character. In the static image localization task, accuracy decreased from near perfect to <20% with decreasing contrast (patient 1). Patient 2 scored up to 70% at 100% contrast. In the dynamic image localization task, patient 1 recognized the trajectory of the image up to speeds of 64 deg/s, whereas patient 2 scored just above chance. The degree of eye movement in both patients was related to accuracy and, to some extent, stimulus direction. Conclusions: The ability to identify characters and localize percepts demonstrates the capacity of the suprachoroidal device to provide meaningful information to blind patients. The variation in scores across all tasks highlights the importance of using spatial cues from phosphenes, which becomes more difficult at low contrast. The use of spatial information from multiple electrodes and eye-movement compensation is expected to improve performance outcomes during real-world prosthesis use in a camera-based system. (ClinicalTrials.gov number, NCT01603576.).


Subject(s)
Electric Stimulation/methods , Electrodes, Implanted , Pattern Recognition, Visual/physiology , Retina/physiopathology , Retinitis Pigmentosa/surgery , Visual Prosthesis , Adult , Female , Humans , Male , Psychophysics , Retinitis Pigmentosa/physiopathology , Saccades/physiology , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...