Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Micromachines (Basel) ; 15(5)2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38793175

ABSTRACT

This study investigates the feasibility of a simple electrochemical detection of Prostate Cancer Antigen 3 (PCA3) fragments extracted from patients' urine, using a thiolated single-strand DNA probe immobilized on a gold surface without using a redox probe. To enhance the PCA3 recognition process, we conducted a comparative analysis of the hybridization location using two thiolated DNA probes: Probe 1 targets the first 40 bases, while Probe 2 targets the fragment from bases 47 to 86. Hybridization with PCA3 followed, using square wave voltammetry. The limit of detection of the designed genosenors were of the order of (2.2 ng/mL), and (1.6 ng/mL) for Probes 1 and 2, respectively, and the subsequent sensitivities were of the order of (0.09 ± 0.01) µA-1 · µg-1 · mL and (0.10 ± 0.01) µA-1 · µg-1 · mL. Specificity tests were then conducted with the sensor functionalized with Probe 2, as it presents better analytical performances. The electrochemical results indicate that the designed sensor can clearly discriminate a complementary target from a non-complementary one. A further modeling of the calibration curves with the Power Law/Hill model indicates that the dissociation constant increases by one order of magnitude, confirming the ability of the designed sensor to perfectly discriminate complementary targets from non-complementary ones.

2.
Biosens Bioelectron ; 217: 114678, 2022 Dec 01.
Article in English | MEDLINE | ID: mdl-36116221

ABSTRACT

Engrailed 2 (EN2) is a homeodomain-containing transcription factor expressed in prostate cancer (PCa) cell lines and is secreted into the urines. It is nowadays considered as a promising non-invasive biomarker for PCa early diagnosis. Herein, we report the design of an electrochemical immunosensor for EN2 detection. The biosensor fabrication involved a covalent immobilization of anti-EN2 antibodies onto a poly para amino benzoic acid (PABA) film electropolymerized on a gold electrode. Square wave voltammetry was investigated for EN2 detection in a phosphate buffer solution in a concentration range of 10-5 ng/mL to 1 µg/mL. The limit of detection of the designed sensor was equal to 10-5 ng/mL and the sensitivity was of order of (29 ± 2) µL/ng. The dissociation constant Kd of the "complex" EN2/anti-EN2, estimated from a Hill model, was of order of (0.9 ± 0.2) fM. Experimental results revealed that the immunosensor enabled selective detection of EN2 in a mixture of three proteins which can be found in men' urine: human serum albumin (HSA), prostate-specific antigen (PSA) and immunoglobulin G (IgG). Tests in artificial urine, with an ionic strength of 0.18 M, have been done and results were found comparable to those obtained in PBS (0.16 M). These encouraging results show a potentially promising future for the development of an electrochemical biosensor for robust and accurate urinary biomarkers detection.


Subject(s)
Biosensing Techniques , Prostatic Neoplasms , 4-Aminobenzoic Acid , Biomarkers, Tumor , Early Detection of Cancer , Electrochemical Techniques , Gold , Homeodomain Proteins , Humans , Immunoassay , Immunoglobulin G , Limit of Detection , Male , Nerve Tissue Proteins , Phosphates , Prostate , Prostate-Specific Antigen , Prostatic Neoplasms/diagnosis , Serum Albumin, Human , Transcription Factors
3.
Sensors (Basel) ; 21(2)2021 Jan 17.
Article in English | MEDLINE | ID: mdl-33477338

ABSTRACT

Several studies were devoted to the design of molecularly imprinted polymer (MIP)-based sensors for the detection of a given protein. Here, we bring elements that could contribute to the understanding of the interaction mechanism involved in the recognition of a protein by an imprint. For this purpose, a polydopamine (PDA)-MIP was designed for bovine serum albumin (BSA) recognition. Prior to BSA grafting, the gold surfaces were functionalized with mixed self-assembled monolayers of (MUDA)/(MHOH) (1/9, v/v). The MIP was then elaborated by dopamine electropolymerization and further extraction of BSA templates by incubating the electrode in proteinase K solution. Three complementary techniques, electrochemistry, zetametry, and Fourier-transform infrared spectrometry, were used to investigate pH and ionic strength effects on a MIP's design and the further recognition process of the analytes by the imprints. Several MIPs were thus designed in acidic, neutral, and basic media and at various ionic strength values. Results indicate that the most appropriate conditions, to achieve a successful MIPs, were an ionic strength of 167 mM and a pH of 7.4. Sensitivity and dissociation constant of the designed sensor were of order of (3.36 ± 0.13) µA·cm-2·mg-1·mL and (8.56 ± 6.09) × 10-11 mg/mL, respectively.


Subject(s)
Osmolar Concentration , Hydrogen-Ion Concentration , Indoles , Molecular Imprinting , Polymers
SELECTION OF CITATIONS
SEARCH DETAIL
...