Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
Add more filters










Publication year range
1.
Anal Chim Acta ; 1208: 339778, 2022 May 22.
Article in English | MEDLINE | ID: mdl-35525599

ABSTRACT

With the emergence of microRNAs as key biomarkers for disease diagnosis such as lung cancer, various techniques have been settled for their detection. However, these current methods require different amplification steps since numerous challenges for detecting circulating miRNAs are attributable to their intrinsic properties accounting for tiny sizes, high sequence similarity, and low abundance. Duplex specific nuclease (DSN)-based microRNA amplification has recently gained interest in biosensing applications thanks to its catalytic activity based on target recycling. In this context, we designed a highly selective, sensitive, and multiplexed fluorescence-based biosensor combining DSN enzyme and magnetic beads to detect three distinct microRNAs, including microRNA-21, microRNA-210, and microRNA-486-5p. By exploiting the above approach, we were able to detect as low as 98 aM, 120 aM, and 300 aM of mir-21, miR-210, and miR-486-5p, respectively. Furthermore, this recommended strategy displays a high selectivity toward an entirely matched target than the off-target. These results are ascribed to the potent DSN enzyme activity and to the locked nucleic acid (LNA)-modified DNA probe that boosted the hetero-duplex probe/target stability. Lastly, our proposed method was applied to detect microRNAs in the serum samples and displayed a high efficacy to discriminate between healthy controls and lung cancer patients. Furthermore, the analytical accuracy of the proposed strategy was validated with the computed tomography (CT) technique of the chest. Thus based on these findings, this strategy could open new directions for detecting microRNAs associated with several diseases.


Subject(s)
Biosensing Techniques , Lung Neoplasms , MicroRNAs , Biosensing Techniques/methods , DNA Probes/genetics , Endonucleases , Humans , Lung Neoplasms/diagnosis , Lung Neoplasms/genetics , MicroRNAs/genetics , Nucleic Acid Amplification Techniques/methods , Oligonucleotides
2.
Food Chem ; 389: 133051, 2022 Sep 30.
Article in English | MEDLINE | ID: mdl-35490517

ABSTRACT

Dielectric breakdown technique was utlised to fabricate 5-6 nm nanopores for vanillin detection in various food samples. A highly selective aptamer (Van_74) with high binding affinity towards vanillin was used as capture probe. Under optimal conditions, aptamer/vanillin complex translocation induced deeper events than the bare aptamer. As a result, the proposed nanopore aptasensor exhibits a linear range from 0.5 to 5 nM (R2 = 0.972) and a low detection limit of 500 pM, which is significantly better than conventional platforms. Furthermore, our aptasensor showed excellent immunity against different interferons and was used to detect vanillin in different food samples. The food sample measurements were confirmed with an additional UV-Vis assay, the results of the two techniques were statistically evaluated and showed no statistically significant difference. Hence, this work represents a proof-of-concept involving the design and testing of aptamer/nanopore sensors for small molecules detection, which plays a critical role in food safety.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Nanopores , Aptamers, Nucleotide/chemistry , Benzaldehydes , Biosensing Techniques/methods , Gold/chemistry , Limit of Detection
3.
ACS Omega ; 7(2): 2224-2233, 2022 Jan 18.
Article in English | MEDLINE | ID: mdl-35071911

ABSTRACT

Researchers have recently designed various biosensors combining magnetic beads (MBs) and duplex-specific nuclease (DSN) enzyme to detect miRNAs. Yet, the interfacial mechanisms for surface-based hybridization and DSN-assisted target recycling are relatively not well understood. Thus, herein, we developed a highly sensitive and selective fluorescent biosensor to study the phenomenon that occurs on the local microenvironment surrounding the MB-tethered DNA probe via detecting microRNA-21 as a model. Using the above strategy, we investigated the influence of different DNA spacers, base-pair orientations, and surface densities on DSN-assisted target recycling. As a result, we were able to detect as low as 170 aM of miR-21 under the optimized conditions. Moreover, this approach exhibits a high selectivity in a fully matched target compared to a single-base mismatch, allowing the detection of miRNAs in serum with improved recovery. These results are attributed to the synergetic effect between the DSN enzyme activity and the neutral DNA spacer (triethylene glycol: TEG) to improve the miRNA detection's sensitivity. Finally, our strategy could create new paths for detecting microRNAs since it obliterates the enzyme-mediated cascade reaction used in previous studies, which is more expensive, more time-consuming, less sensitive, and requires double catalytic reactions.

5.
Vet Med Sci ; 7(5): 1831-1840, 2021 09.
Article in English | MEDLINE | ID: mdl-34021737

ABSTRACT

Vaccination with inactivated bacterin is the most popular and practical measure to control enzootic pneumonia. After immunisation with inactivated bacterin, Mycoplasma hyopneumoniae colonised on the respiratory tract and lung stimulates the humoural immune responses and produces IgG and IgA antibodies. ELISA is a widely used serological method to detect M. hyopneumoniae antibodies. However, commercial IgG-ELISA kit cannot distinguish between inactivated bacterin-induced hyperimmune sera and convalescent sera stimulated by natural infection. SIgA-ELISA method needs to collect nasal swabs, but collecting nasal swabs is not easy to operate. Establishment of a discriminative ELISA detecting humoural IgG from convalescent sera but not hyperimmune sera facilitates to evaluate the natural infection of M. hyopneumoniae after inactivated bacterin vaccination. We expressed and purified a recombinant protein named Mhp366-N which contains an epitope recognised by the convalescent sera but not hyperimmune sera. The developed discriminative IgG-ELISA could discriminate between inactivated bacterin-induced hyperimmune sera and convalescent sera and was reproducible, sensitive and specific to M. hyopneumoniae antibody produced by natural infection. Compared to SIgA-ELISA method, discriminative IgG-ELISA was more convenient to detect IgG antibody from sera than IgA from nasal swabs, although it has limited sensitivity in the early stages of infection. Additionally, to some extent, it has a potential to avoid the interference of maternally derived IgG antibodies. The established discriminative IgG-ELISA was efficient to judge the serological IgG antibodies induced from natural infection or inactivated vaccine stimulation and provided a useful method to investigate and evaluate the live organism infection after the application of inactivated bacterin.


Subject(s)
Mycoplasma hyopneumoniae , Pneumonia of Swine, Mycoplasmal , Swine Diseases , Animals , Bacterial Vaccines , Enzyme-Linked Immunosorbent Assay/methods , Enzyme-Linked Immunosorbent Assay/veterinary , Pneumonia of Swine, Mycoplasmal/diagnosis , Pneumonia of Swine, Mycoplasmal/prevention & control , Swine , Swine Diseases/prevention & control , Vaccination/veterinary
6.
Anal Sci ; 37(6): 825-831, 2021 Jun 10.
Article in English | MEDLINE | ID: mdl-33041307

ABSTRACT

A synergistic nanocomposite film composed of gold nanourchins (AuNU), oxidised carbon nanohorns (CNH), and chitosan functioned as an electrode modifier in the fabrication of the sensitive lipocalin-2 (LCN-2) aptasensor. The AuNUs/CNH/CS composite increased the surface area and thereby amplified the signal transduction. The amine-terminated LCN-2 aptamer was immobilised through the amide bond formed between the carboxyl group of polyglutamic acid (PGA) and the amine group of aptamer. Interaction of LCN-2 with the aptamer caused conformational changes in the structure of the aptamer. This generated higher conductivity, resulting in increased DPV peak current. The DPV signal increased with increasing concentration of LCN-2, and the change in signal was used for quantitative detection. The proposed aptasensor was able to detect LCN-2 in the linear range of 0.1 - 100.0 pg mL-1, with a low detection limit of 10 fg mL-1. The aptasensor showed high sensitivity, selectivity, reproducibility, and was able to detect LCN-2 in serum samples.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Metal Nanoparticles , Nanotubes, Carbon , Electrochemical Techniques , Electrodes , Gold , Limit of Detection , Lipocalin-2 , Reproducibility of Results
7.
Nanomaterials (Basel) ; 9(4)2019 Apr 09.
Article in English | MEDLINE | ID: mdl-30970578

ABSTRACT

Monolayer WS2 (Tungsten Disulfide) with a direct-energy gap and excellent photoluminescence quantum yield at room temperature shows potential applications in optoelectronics. However, controllable synthesis of large-area monolayer WS2 is still challenging because of the difficulty in controlling the interrelated growth parameters. Herein, we report a facile and controllable method for synthesis of large-area monolayer WS2 flakes by direct sulfurization of powdered WO3 (Tungsten Trioxide) drop-casted on SiO2/Si substrates in a one-end sealed quartz tube. The samples were thoroughly characterized by an optical microscope, atomic force microscope, transmission electron microscope, fluorescence microscope, photoluminescence spectrometer, and Raman spectrometer. The obtained results indicate that large triangular monolayer WS2 flakes with an edge length up to 250 to 370 µm and homogeneous crystallinity were readily synthesized within 5 min of growth. We demonstrate that the as-grown monolayer WS2 flakes show distinctly size-dependent fluorescence emission, which is mainly attributed to the heterogeneous release of intrinsic tensile strain after growth.

8.
Langmuir ; 34(49): 14825-14833, 2018 12 11.
Article in English | MEDLINE | ID: mdl-30021440

ABSTRACT

A versatile and highly sensitive strategy for nanopore detection of microcystin-LR (MC-LR) is proposed herein based on the aptamer and host-guest interactions by employing a gold nanoparticle (AuNP) probe. The aptamer of MC-LR and its complementary DNA (cDNA) are respectively immobilized on AuNPs with distinct sizes (5 nm AuNPs for the aptamer and 20 nm for the cDNA), and the constructed polymeric AuNP network via the hybridization of the aptamer and cDNA was disintegrated upon the addition of MC-LR. The specific interactions between the aptamer and MC-LR disrupt and release the cDNA-AuNPs that were then removed by centrifugation, leaving the MC-LR-aptamer-AuNP species in the supernatant for subsequent nanopore determination. By monitoring the current blockade of released MC-LR-aptamer-AuNPs using a specific tailored nanopore (10 and 20 nm in diameter, generated by current dielectric breakdown), we could deduce the presence of MC-LR, as the bulky NP network could not pass through a nanopore with a relatively smaller size. We realized the detection of MC-LR with a concentration as low as 0.1 nM; additionally, we have proved the specificity of the interaction between the aptamer and MC-LR by replacing MC-LR with other congener toxins (MC-RR and MC-YR), chlorophyll (a component abundantly coexists in water), and the mixture of the four.

9.
Spectrochim Acta A Mol Biomol Spectrosc ; 190: 417-422, 2018 Feb 05.
Article in English | MEDLINE | ID: mdl-28957703

ABSTRACT

The analysis of algae and dominant alga plays important roles in ecological and environmental fields since it can be used to forecast water bloom and control its potential deleterious effects. Herein, we combine in vivo confocal resonance Raman spectroscopy with multivariate analysis methods to preliminary identify the three algal genera in water blooms at unicellular scale. Statistical analysis of characteristic Raman peaks demonstrates that certain shifts and different normalized intensities, resulting from composition of different carotenoids, exist in Raman spectra of three algal cells. Principal component analysis (PCA) scores and corresponding loading weights show some differences from Raman spectral characteristics which are caused by vibrations of carotenoids in unicellular algae. Then, discriminant partial least squares (DPLS) classification method is used to verify the effectiveness of algal identification with confocal resonance Raman spectroscopy. Our results show that confocal resonance Raman spectroscopy combined with PCA and DPLS could handle the preliminary identification of dominant alga for forecasting and controlling of water blooms.


Subject(s)
Microalgae/classification , Principal Component Analysis , Spectrum Analysis, Raman , Carotenoids/chemistry , Discriminant Analysis , Least-Squares Analysis
10.
Mater Sci Eng C Mater Biol Appl ; 74: 465-470, 2017 May 01.
Article in English | MEDLINE | ID: mdl-28254318

ABSTRACT

Tuberculosis is a worldwide disease considered as a major health problem with high morbidity and mortality rates. Poor detection of Mycobacterium tuberculosis (Mtb), the causative agent of tuberculosis remains a major obstacle to the global control of this disease. Here we report the development of a new test based on the detection of the major virulent factor of Mtb, namely the early secreted antigenic target 6-kDa protein or ESAT-6. A label free electrochemical immunosensor using an anti-ESAT-6 monoclonal antibody as a bio-receptor is described herein. Anti-ESAT-6 antibodies were first covalently immobilized on the surface of a gold screen-printed electrode functionalized via a self-assembled thiol monolayer. Interaction between the bio-receptor and ESAT-6 antigen was evaluated by square wave voltammetry method using [Fe(CN)6]3-/4- as redox probe. The detection limit of ESAT-6 antigen was 7ng/ml. The immunosensor has also been able to detect native ESAT-6 antigen secreted in cell culture filtrates of three pathogenic strains of Mtb (CDC1551, H37RV and H8N8). Overall, this work describes an immune-electrochemical biosensor, based on ESAT-6 antigen detection, as a useful diagnostic tool for tuberculosis.


Subject(s)
Antigens, Bacterial/analysis , Bacterial Proteins/analysis , Biosensing Techniques , Electrochemical Techniques , Mycobacterium tuberculosis/metabolism , Tuberculosis/diagnosis , Antibodies, Immobilized/chemistry , Antibodies, Immobilized/immunology , Antibodies, Monoclonal/chemistry , Antibodies, Monoclonal/immunology , Antigens, Bacterial/genetics , Antigens, Bacterial/immunology , Bacterial Proteins/genetics , Bacterial Proteins/immunology , Electrodes , Ferricyanides/chemistry , Humans , Limit of Detection , Miniaturization , Mycobacterium tuberculosis/isolation & purification , Recombinant Proteins/biosynthesis , Recombinant Proteins/immunology , Recombinant Proteins/isolation & purification , Tuberculosis/microbiology
11.
ACS Omega ; 2(10): 7127-7135, 2017 Oct 31.
Article in English | MEDLINE | ID: mdl-31457292

ABSTRACT

In this work, we demonstrate a chemical modification approach, by means of covalent-bonding amphoteric poly-l-lysine (PLL) on the interior nanopore surface, which could intensively protect the pore from etching when exposed in the electrolyte under various pH conditions (from pH 4 to 12). Nanopore was generated via simple current dielectric breakdown methodology, covalent modification was performed in three steps, and the functional nanopore was fully characterized in terms of chemical structure, hydrophilicity, and surface morphology. I-V curves were recorded under a broad range of pH stimuli to evaluate the stability of the chemical bonding layer; the plotted curves demonstrated that nanopore with a covalent bonding layer has good pH tolerance and showed apparent reversibility. In addition, we have also measured the conductance of modified nanopore with varied KCl concentration (from 0.1 mM to 1 M) at different pH conditions (pHs 5, 7, 9, and 11). The results suggested that the surface charge density does not fluctuate with variation in salt concentration, which inferred that the SiN x nanopore was fully covered by PLL. Moreover, the PLL functionalized nanopore has realized the detection of single-stranded DNA homopolymer translocation under bias voltage of 500 mV, and the 20 nt homopolymers could be evidently differentiated in terms of the current amplitude and dwell time at pHs 5, 8, and 11.

12.
Talanta ; 128: 473-9, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25059188

ABSTRACT

In this work, a non-enzymatic chemiresistive sugar sensor has been developed by combining a synthetic receptor with aligned single-walled carbon nanotubes (SWNTs) device. Briefly, boronic acid as a multivalent sugar receptor was immobilized on carbon nanotubes through amide bond formation. The interaction between three common sugars (d-glucose, d-fructose and sucrose) and boronic acid modified SWNTs device was studied. The effect of pH on the receptor-ligand binding was examined and highest response was observed at pH 9. The chemiresistive sensor exhibited specific and reproducible detection with sensitivity over the concentration range of 1-20mM, 1-25 mM, and 1-30 mM for fructose, glucose, and sucrose, respectively. The sensor showed no interference from common electroactive compounds such as citric acid, uric acid, and ascorbic acid. Furthermore, the sensor retained 97.4% of the initial value after five regeneration cycles with an acidic buffer at pH 5, thus ensuring good reusability.


Subject(s)
Biosensing Techniques/methods , Boronic Acids/chemistry , Carbohydrates/analysis , Nanotubes, Carbon/chemistry , Carbohydrates/chemistry , Fructose/analysis , Fructose/chemistry , Glucose/analysis , Glucose/chemistry , Hydrogen-Ion Concentration , Reproducibility of Results , Sucrose/analysis , Sucrose/chemistry
13.
Analyst ; 139(12): 3077-82, 2014 Jun 21.
Article in English | MEDLINE | ID: mdl-24776682

ABSTRACT

The poly(aniline boronic acid) (PABA)-functionalized single-walled carbon nanotube (SWNT) non-enzymatic sensor was developed for the detection of saccharides. The work involved the electrochemical polymerization of 3-aminophenylboronic acid (3-APBA) in the presence of fluoride on the surface of SWNTs and their subsequent evaluation as chemiresistive sensors towards the detection of d-fructose and d-glucose. By varying the sensor's synthesis conditions by charge-controlled electropolymerization, the sensing performance was systematically optimized. Through electrical characterization in terms of change in resistance, cyclic voltammetry confirmed the electrochemical deposition of the PABA coating on the SWNTs. The optimized sensors showed sensing response over a wide dynamic range of concentrations and a limit of detection of 2.92 mM for D-fructose and 3.46 mM for D-glucose. The hybrid sensors could be regenerated on the basis of the reversible nature of the binding between PABA and 1,2- or 1,3-diols at lower values of pH.


Subject(s)
Boronic Acids/chemistry , Carbohydrates/analysis , Nanotubes, Carbon , Polymers/chemistry
14.
Anal Chem ; 85(10): 4893-901, 2013 May 21.
Article in English | MEDLINE | ID: mdl-23510137

ABSTRACT

Here, we integrate two complementary detection strategies for the identification and quantification of Escherichia coli based on bacteriophage T4 as a natural bioreceptor for living bacteria cells. The first approach involves screening and viability assays, employing bacteriophage as the recognition element in label-free electrochemical impedance spectroscopy. The complementary approach is a confirmation by loop-mediated isothermal amplification (LAMP) to amplify specifically the E. coli Tuf gene after lysis of the bound E. coli cells, followed by detection using linear sweep voltammetry. Bacteriphage T4 was cross-linked, in the presence of 1,4-phenylene diisothiocyanate, on a cysteamine-modified gold electrode. The impedimetric biosensor exhibits specific and reproducible detection with sensitivity over the concentration range of 10(3)-10(9) cfu/mL, while the linear response of the LAMP approach was determined to be 10(2)-10(7) cfu/mL. The limit of detection (LOD) of 8 × 10(2) cfu/mL in less than 15 min and 10(2) cfu/mL within a response time of 40 min were achieved for the impedimetric and LAMP method, respectively. This work provides evidence that integration of the T4-bacteriophage-modified biosensor and LAMP can achieve screening, viability, and confirmation in less than 1 h.


Subject(s)
Bacteriophage T4 , Biosensing Techniques/methods , Dielectric Spectroscopy/methods , Escherichia coli/isolation & purification , Escherichia coli/physiology , Microbial Viability , Biosensing Techniques/economics , Dielectric Spectroscopy/economics , Electrochemistry , Escherichia coli/virology , Reproducibility of Results , Time Factors
15.
Biosens Bioelectron ; 39(1): 220-5, 2013 Jan 15.
Article in English | MEDLINE | ID: mdl-22898660

ABSTRACT

The detection of cancer biomarkers is as important tool for the diagnosis and prognosis of cancer such as brain cancer. Murine double minute 2 (MDM2) has been widely studied as prognostic marker for brain tumor. Here we describe development of a new sensitive label free impedimetric immunosensor for the detection of MDM2 based on cysteamine self assembled monolayers on a clean polycrystalline Au electrode surface. The amine-modified electrodes were further functionalized with antibody using homobifunctional 1,4-phenylene diisothiocyanate (PDITC) linker. The assembly processes of the immunosensor had been monitored with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques using Fe(CN)(6)(3-/4-) solution as redox probe. The impedance changes upon binding of MDM2 protein to the sensor surface was utilized for the detection of MDM2. The increase in relative electron-transfer resistance (ΔR/R(0)%) values was linearly proportional to the concentration of tumor marker MDM2 in the wide dynamic range of 1pg/ml-1µg/ml. The limit of detection was 0.29pg/ml in phosphate buffer saline (PBS) and 1.3pg/ml in mouse brain tissue homogenate, respectively. The immunosensor showed a good performance in comparison with ELISA for the analysis of the MDM2 in the cancerous mouse brain tissue homogenates. Moreover, the immunosensor had a good selectivity against epidermal growth factor receptor (EGFR) protein, long-storage stability and reproducibility. It might be become a promising assay for clinical diagnosis and early detection of tumors.


Subject(s)
Brain Neoplasms/diagnosis , Brain/pathology , Dielectric Spectroscopy/methods , Proto-Oncogene Proteins c-mdm2/analysis , Animals , Antibodies, Immobilized/immunology , Biosensing Techniques/methods , Brain Chemistry , Brain Neoplasms/pathology , Cysteamine/chemistry , Electrodes , Humans , Immunoassay/methods , Limit of Detection , Mice , Proto-Oncogene Proteins c-mdm2/immunology , Thiocyanates/chemistry
16.
Talanta ; 103: 228-35, 2013 Jan 15.
Article in English | MEDLINE | ID: mdl-23200382

ABSTRACT

Fabrication of an enzyme amperometric biosensor for glucose via electropolymerization of pyrrole in the presence of glucose oxidase onto a hydrogel coated platinum electrode is hereby established as a viable biotransducer fabrication method. Platinum micro- (φ=25 µm) and macro- (φ=100 µm) electrodes were electrochemically activated and chemically modified with 3-aminopropyl-trimethoxysilane (APTMS), functionalized with acryloyl(polyethyleneglycol)-N-hydroxysuccinamide (ACRL-PEG-NHS), dipped into a polyHEMA based hydrogel cocktail and UV cross-linked. Electropolymerization of Py in the presence of GOx produced glucose responsive biotransducers that showed; (i) a 4-fold reduction in sensitivity compared with directly electropolymerized PPy films, (ii) an electropolymerization charge density dependence of biotransducer sensitivity and enzyme activity that was maximal at 1.0 mC/cm(2) with an apparent K(M) of 33 mM, (iii) interference screening of ascorbic acid and (iv) a temporal increase in sensitivity with storage over a 17 days period. This method has the ability to precisely and quantitatively add enzyme catalytic bioactivity to metal or semiconductor biointerfaces for applications in biosensors, bioelectronics and bionics.


Subject(s)
Biosensing Techniques , Electrochemistry , Enzymes, Immobilized/chemistry , Glucose/analysis , Hydrogels/chemistry , Polymers/chemistry , Ascorbic Acid/chemistry , Cross-Linking Reagents/pharmacology , Electrodes , Glucose Oxidase/metabolism , Hydrogen Peroxide/chemistry , Platinum/chemistry
17.
Analyst ; 137(24): 5749-56, 2012 Dec 21.
Article in English | MEDLINE | ID: mdl-23085745

ABSTRACT

The objective of this study was to develop a biosensor using the cell wall binding domain (CBD) of bacteriophage-encoded peptidoglycan hydrolases (endolysin) immobilized on a gold screen printed electrode (SPE) and subsequent electrochemical impedance spectroscopy (EIS) for a rapid and specific detection of Listeria cells. The endolysin was amine-coupled to SPEs using EDC/NHS chemistry. The CBD-based electrode was used to capture and detect the Listeria innocua serovar 6b from pure culture and 2% artificially contaminated milk. In our study, the endolysin functionalized SPEs have been characterized using X-ray photoelectron spectroscopy (XPS). The integration of endolysin-based recognition for specific bacteria and EIS can be used for direct and rapid detection of Listeria cells with high specificity against non-Listeria cells with a limit of detection of 1.1 × 10(4) and 10(5) CFU mL(-1) in pure culture and 2% milk, respectively.


Subject(s)
Bacteriophages/enzymology , Biosensing Techniques/methods , Dielectric Spectroscopy , Endopeptidases/chemistry , Endopeptidases/metabolism , Listeria/cytology , Cell Wall/metabolism , Electrochemistry , Enzymes, Immobilized/chemistry , Enzymes, Immobilized/metabolism , Gold/chemistry , Listeria/isolation & purification , Protein Structure, Tertiary , Surface Properties , Time Factors
18.
Environ Sci Technol ; 46(19): 10697-703, 2012 Oct 02.
Article in English | MEDLINE | ID: mdl-22958101

ABSTRACT

The efficiency of current microcystin detection methods has been hampered by the low detection limits required in drinking water and that routine detection is restricted to a few of the congeners with high degree of undesired cross-reactivity. Here, we report the development of novel microcystin-targeting molecules and their application in microcystin detection. We have selected DNA aptamers from a diverse random library that exhibit high affinity and specificity to microcystin-LR, -YR, and -LA. We obtained aptamers that bind to all chosen congeners with high affinity with K(D) ranging from 28 to 60 nM. More importantly, we also obtained aptamers that are selective among the different congeners, with selectivity from 3-folds difference in binding affinity to total discrimination (K(D) of 50 nM versus nonspecific binding). Electrochemical aptasensors constructed with the selected aptamers were able to achieve sensitive and congener-specific microcystin detection with detection limit as low as 10 pM.


Subject(s)
Aptamers, Nucleotide/chemistry , Biosensing Techniques/methods , Microcystins/analysis , Aptamers, Nucleotide/metabolism , Base Sequence , Gene Library , Limit of Detection , Marine Toxins , Microcystins/chemistry , Microcystins/metabolism , Molecular Sequence Data , Sensitivity and Specificity
19.
Biosens Bioelectron ; 38(1): 308-13, 2012.
Article in English | MEDLINE | ID: mdl-22789151

ABSTRACT

A novel label-free voltammetric immunosensor for sensitive detection of ß-lactoglobulin using graphene modified screen printed electrodes has been developed. The derivatization of the graphene electrode surface was achieved by electrochemical reduction of in situ generated 4-nitrophenyl diazonium cations in aqueous acidic solution, followed by electrochemical reduction of the terminal nitro groups to amines. The electrochemical modification protocol was optimized in order to generate monolayer of nitrophenyl groups on the graphene surface without complete passivation of the electrode. Unlike the reported method for graphene functionalization, we demonstrated here the ability of the electrografting of aryl diazonium salt to attach an organic film to the graphene surface in a controlled manner by choosing the suitable grafting protocol. Next, the amine groups on the graphene surface were activated using glutaraldehyde and used for the covalent immobilization of ß-lactoglobulin antibodies. Cyclic and differential pulse voltammetry carried out in an aqueous solution containing [Fe(CN)(6)](3-/4-) redox pair have been used for the immunosensor characterization. The results demonstrated that the DPV reduction peak current of [Fe(CN)(6)](3-/4-) decreased linearly with increasing the concentration of ß-lactoglobulin due to the formation of antibody-antigen complex on the modified electrode surface. The immunosensor obtained using this novel approach enabled a detection limit of 0.85 pg mL(-1) and a dynamic range from 1 pg mL(-1) to 100 ng mL(-1) of ß-lactoglobulin in PBS buffer. In addition, the immunosensor evaluated in different samples including cake, cheese snacks, a sweet biscuit, showing excellent correlation with the results obtained from commercially enzyme-linked immunosorbent assay (ELISA) method.


Subject(s)
Antibodies, Immobilized/chemistry , Carbon/chemistry , Electrochemical Techniques/methods , Graphite/chemistry , Lactoglobulins/analysis , Milk/chemistry , Animals , Antibodies, Immobilized/immunology , Electrodes , Food Analysis/methods , Immunoassay/methods , Lactoglobulins/immunology , Limit of Detection
20.
Appl Biochem Biotechnol ; 166(4): 878-88, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22212391

ABSTRACT

Electrode-supported hydrogels were conferred with the biospecificity of enzymes during the process of electropolymerization to give rise to a class of bioactive, stimuli-responsive co-joined interpenetrating networks of inherently conductive polymers and highly hydrated hydrogels. Glucose responsive biotransducers were prepared by potentiostatic electropolymerization [750 mV vs. Ag/AgCl (3 M KCl)] of pyrrole at Poly(hydoxyethyl methacrylate)-based hydrogel-coated Pt micro-electrodes (Φ = 100 µm) from aqueous solutions of pyrrole and glucose oxidase (GOx; 0.4 M pyrrole, 1.0 mg/ml GOx) to 1.0 and 10.0 mC/cm². Polypyrrole was them over-oxidized by cyclic voltammetry (0-1.2 V vs. Ag/AgCl, 40 cycles in PBKCl, pH = 7.0). Biotransducers were stored at 4 °C in PBKCl for up to 18 days. Amperometric dose-response at 0.4 V vs. Ag/AgCl followed by Lineweaver-Burk analysis produced enzyme kinetic parameters as a function of electropolymerization charge density and storage time. Apparent Michaelis constant (K (Mapp)) increased from 18.6-152.0 mM (1.0 mC/cm²) and from 2.7-6.1 mM (10.0 mC/cm²). Biotransducer sensitivity increased to 21.2 nA/mM after 18 days and to 12.8 pA/mM after 10 days for the 1.0 and 10.0 mC/cm² membranes, respectively. Maximum current, I (max), also increased over time to 2.7 nA (1.0 mC/cm²) and to 170 pA (10.0 mC/cm²). Electropolymerization of polypyrrole is shown to be an effective means for imparting bioactivity to a hydrogel-coated microelectrode. GOx was shown to be stabilized and to increase activity over time within the electroconductive hydrogel.


Subject(s)
Biosensing Techniques/methods , Electrochemical Techniques/methods , Glucose Oxidase/chemistry , Glucose/analysis , Biosensing Techniques/instrumentation , Electrochemical Techniques/instrumentation , Enzymes, Immobilized/chemistry , Hydrogels/chemistry , Hydrogen-Ion Concentration , Kinetics , Microelectrodes , Polyamines/chemistry , Polyhydroxyethyl Methacrylate/analogs & derivatives , Polyhydroxyethyl Methacrylate/chemistry , Polymers/chemistry , Pyrroles/chemistry , Solutions , Static Electricity
SELECTION OF CITATIONS
SEARCH DETAIL
...