Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Comput Biol Med ; 50: 97-106, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24845020

ABSTRACT

We designed the GammaKey system for the acquisition, storage and analysis of images from semi-analogue gamma scintillation cameras (GSCs). The GammaKey system, operating on a standard PC, replicates the functionality of earlier dedicated computer systems, allows the exchange of data in the DICOM format and has an open architecture enabling the development of new diagnostic techniques. The main purpose of the GammaKey is to enable the continued use of old GSCs which have functional scintillation crystals, but also to permit data exchange with new digital GSCs. The GammaKey has been technically validated by standards established by the National Electrical Manufacturers Association. The GammaKey has been used for seven years in two leading centres for nuclear medicine in Serbia (the Clinical Center of Serbia, Belgrade, and the Clinical Center of Vojvodina, Novi Sad) in approximately 30,000 patients. Clinical application proves that the GammaKey is a robust and reliable system with high-quality image output. Data processing can be upgraded with non-standard features added on request as shown in two examples: (1) the testing of splenectomy efficacy in the case of thrombocytopenia with normal production; and (2) the detection and localisation of parathyroid adenomas.


Subject(s)
Gamma Cameras , Image Processing, Computer-Assisted/methods , Medical Informatics/methods , Algorithms , Automation , Computer Systems , Humans , Lung/diagnostic imaging , Nuclear Medicine/methods , Parathyroid Neoplasms/diagnostic imaging , Perfusion , Radionuclide Imaging , Saliva/metabolism , Serbia , Software , Splenectomy/methods , Thrombocytopenia/surgery
2.
Cancer Biother Radiopharm ; 29(3): 108-15, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24450327

ABSTRACT

AIM: The aim was to investigate somatostatin receptor (sstr) expression in normal prostate by determining the maximum standardized uptake value (SUVmax) of (68)Ga-DOTATOC PET/CT in neuroendocrine tumor (NET) patients, without NET involvement of the prostate gland, for establishing the reference standard. METHODS: Sixty-four NET patients underwent (68)Ga-DOTATOC PET/CT. SUVmax of the prostate gland, normal liver, testes, and gluteus muscles were evaluated. The prostate gland size was measured. Statistical analysis was performed using dedicated software (SPSS13). RESULTS: Mean/median (68)Ga-DOTATOC SUVmax values were as follows: normal prostate 2.6 ± 0.0, slightly enlarged prostate 4.2 ± 1.6, prostatic hypertrophy 4.9 ± 1.6, prostatic hyperplasia 5.0 ± 1.5, prostate cancer 9.5 ± 2.1, normal liver 7.3 ± 1.8, testes 1.8 ± 0.5, and gluteus 1.0 ± 0.2. The normal prostate gland had three times less sstr expression than normal liver tissue. Strong correlation was found between patient age and sstr expression in prostate/prostate size. No significant difference existed in sstr expression between prostatic hypertrophy and hyperplasia. Much higher sstr expression was found in prostatic cancer compared with normal prostate. CONCLUSION: (68)Ga-DOTATOC PET/CT defines the baseline sstr uptake in prostate not affected by NET (significantly lower than in the liver). Higher values were established in prostatic hyperplasia and hypertrophy. Only concomitant prostate cancer was associated with higher SUVmax in comparison with non-neoplastic liver.


Subject(s)
Neuroendocrine Tumors/diagnostic imaging , Octreotide/analogs & derivatives , Organometallic Compounds , Prostate/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Receptors, Somatostatin/analysis , Adult , Aged , Aged, 80 and over , Gallium Radioisotopes , Humans , Male , Middle Aged , Positron-Emission Tomography , Prostate/chemistry , Prostatic Hyperplasia/diagnostic imaging , Tomography, X-Ray Computed
3.
Nucl Med Commun ; 30(1): 68-75, 2009 Jan.
Article in English | MEDLINE | ID: mdl-19306516

ABSTRACT

OBJECTIVE: Optimal treatment for chronic total occlusion (CTO) in the infarct-related coronary artery is not clear. Our aim was to assess myocardial perfusion, left ventricular ejection fraction (EF), and left ventricular size using gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging with 99mTc-methoxy-isobutyl-isonitrile in patients with CTO before and 1 year after recanalization. METHODS: Thirty patients with earlier myocardial infarction and at least one CTO underwent percutaneous coronary intervention (PCI) as well as nitrate-enhanced gated SPECT myocardial perfusion and dobutamine stress echocardiography before and 11 +/- 1 months after recanalization. They were divided into three groups based on the outcome of the follow-up angiography: (i) successful recanalization with no evidence of in-stent restenosis (n=13); (ii) successful recanalization with in-stent restenosis (n=7) and (iii) unsuccessful recanalization (n=10). RESULTS: Overall success of recanalization for CTO was 74%. In group 1, myocardial viability was preserved in 11 of 13 (85%) patients at baseline. Gated SPECT at 1 year showed a significant decrease in perfusion abnormalities (29 +/- 12 to 23 +/- 14%, P < 0.05) and left ventricular end-diastolic volume (EDV) (168 +/- 47 to 151 +/- 47 ml, P < 0.05). Improvement in EF (51 +/- 11 to 54 +/- 13%, P > 0.05) and reduction in left ventricular end-systolic volume (ESV) (84 +/- 37 to 77 +/- 40 ml, P > 0.05) did not reach the level of significance. Myocardial viability was preserved in only two of seven patients (28%) in group 2. Neither mean perfusion abnormalities (37 +/- 24 to 35 +/- 22%, P > 0.05) nor global left ventricular parameters (EF 41 +/- 15 vs. 42 +/- 19%, EDV 298 +/- 33 vs. 299 +/- 57 mL, ESV 197 +/- 12 vs. 195 +/- 32 ml; P > 0.05) changed at the follow-up. In group 3, myocardial viability was preserved in seven of 10 patients (70%) at baseline, but no significant changes in perfusion (40 +/- 18 vs. 41 +/- 19%, P > 0.05) and left ventricular function (EF 42 +/- 17 vs. 44 +/- 14%, EDV 228 +/- 101 vs. 227 +/- 81 ml, ESV 143 +/- 87 vs. 146 +/- 8 ml; P > 0.05) were seen at the follow-up. CONCLUSION: Myocardial perfusion and EDV may significantly improve 1 year after PCI provided recanalization of CTO was successful. Our preliminary findings suggest that successful recanalization of CTO may have favorable outcome on left ventricular perfusion and function, particularly in patients with viable myocardium before PCI. The gated SPECT myocardial perfusion imaging with 99mTc-methoxy-isobutyl-isonitrile may be useful for monitoring long-term functional outcome of PCI in patients with CTO.


Subject(s)
Coronary Occlusion/diagnostic imaging , Coronary Occlusion/physiopathology , Myocardial Infarction/complications , Myocardial Infarction/diagnostic imaging , Technetium Tc 99m Sestamibi , Administration, Cutaneous , Cardiac-Gated Single-Photon Emission Computer-Assisted Tomography , Coronary Occlusion/complications , Coronary Occlusion/therapy , Female , Follow-Up Studies , Heart Ventricles/diagnostic imaging , Heart Ventricles/pathology , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Myocardial Ischemia/complications , Myocardial Ischemia/diagnostic imaging , Myocardial Perfusion Imaging , Tissue Survival , Treatment Outcome
4.
Nucl Med Commun ; 30(2): 148-54, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19077915

ABSTRACT

OBJECTIVES: We used gated single-photon emission computed tomography methoxyisobutylisonitrile (SPECT MIBI) to (i) determine whether location of myocardial infarction (MI) and severity of perfusion abnormalities affect post-stress left ventricular function in patients with single-vessel coronary artery disease, and (ii) correlate changes between post-stress and rest ejection fraction (EF) with the severity of perfusion and regional wall motion abnormalities (RWMAs). METHODS: Eighty-eight patients with a history (> or =3 months) of anterior MI (n=45) or inferior MI (n=43) underwent a 2-day stress-rest gated SPECT MIBI. 4D-MSPECT software was used to calculate left ventricular end-diastolic volume (EDV), end-systolic volume (ESV), EF, and the difference from post-stress to rest EF (EFs-EFr). Summed stress scores, summed rest scores, and summed difference scores (SDS) were calculated based on the 17-segment model. RWMAs were visually assessed using a 5-point score. RESULTS: Patients with anterior MI, compared with those with inferior MI, showed significantly greater perfusion abnormalities (summed stress score 11.0+/-5.5 vs. 7.5+/-2.4, P<0.01, summed rest score 7.4+/-4.7 vs. 5.2+/-1.9, P<0.01, SDS 3.3+/-1.0 vs. 1.9+/-1.0, P<0.05) and higher post-stress and rest RWMA (RWMSS 12.2+/-6.0 vs. 8.7+/-4.1, P<0.01, RWMRS 8.7+/-5.4 vs. 5.6+/-3.0, P<0.01). In 22 patients with anterior reversible ischemia in addition to fixed defect, post-stress and rest EDV and ESV were significantly larger and post-stress EF decreased more than in 21 patients with inferior MI (EDV 144.0+/-28.9 ml vs. 108.6+/-36.9 ml, ESV 70.6+/-22.2 ml vs. 53.4+/-20.5 ml, EFs-EFr -4.2+/-3.5% vs. -1.5+/-2.2%, P<0.01). SDS and RWMA were highly correlated with EFs-EFr. CONCLUSION: In patients with single-vessel coronary artery disease, the extent and severity of perfusion and RWMAs assessed by gated SPECT MIBI are greater after anterior MI than inferior MI. Global left ventricular function is significantly more affected after anterior MI only in patients with reversible ischemia in addition to fixed wall defect. Decrease in EF from post-stress to rest is closely associated with the severity of perfusion and RWMAs. Overall results suggest that the extent and severity of perfusion and RWMAs are more prominent in the myocardial region supplied by left anterior descending coronary artery than by right coronary artery, which may explain significantly worse post-stress left ventricular function after anterior MI.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Gated Blood-Pool Imaging/methods , Myocardial Infarction/diagnostic imaging , Technetium Tc 99m Sestamibi , Tomography, Emission-Computed, Single-Photon/methods , Ventricular Dysfunction, Left/diagnostic imaging , Coronary Artery Disease/complications , Exercise Test , Female , Humans , Male , Middle Aged , Myocardial Infarction/complications , Radiopharmaceuticals , Reproducibility of Results , Sensitivity and Specificity , Severity of Illness Index , Ventricular Dysfunction, Left/complications
5.
Nucl Med Rev Cent East Eur ; 7(1): 31-8, 2004.
Article in English | MEDLINE | ID: mdl-15318308

ABSTRACT

BACKGROUND: The aim of this study was to present and compare the results of proposed methods for optimal red cell mass and plasma volume (RCM&PV) estimation, and their influence on the interpretation of obtained results. MATERIAL AND METHODS: In 120/280 patients with polycythaemia rubra vera, subjected to RCM&PV determination with autologous erythrocytes in vitro labelled with 51Cr-sodium chromate, optimal volumes were determined using: 1. traditional ml/kg of: --the real body weight method (ml/kg RBW); --the optimal body weight method (ml/kg OBW). 2. the body weight, height, and sex based method (Retzlaff's tables), 3. the method recommended by the International Council for Standardization in Haematology (ICSH), based on body surface area. RESULTS: Different interpretation of the same results of 120 RCM&PV measurements was registered in 48/120 patients (40%). The greatest disagreement existed between ml/kg RBW and ml/kg OBW methods (in 39/120 subjects, 32.5%). In underweight patients the ml/kg RBW method, and in overweight patients the ml/kg OBW method, offered better agreement with ICSH&Retzlaff's methods. The ml/kg RBW method disagreed with ICSH&Retzlaff's methods and ml/kg OBW in 25% and 19.2% of patients respectively. ICSH and Retzlaff's methods disagreed in 10/120 patients (8.3%). The ICSH method yielded significantly lower optimal volumes than Retzlaff's. CONCLUSION: Three methods for optimal RCM&PV estimation lead to different interpretations of the same results of RCM&PV measurements with 51Cr-erythrocytes in 40% of patients. Two ml/kg body weight methods show greater disagreement in comparison with ICSH and Retzlaff's methods, which differ significantly. The ICSH method yields lower optimal values compared to Retzlaff's.


Subject(s)
Blood Volume Determination/methods , Erythrocytes/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Plasma Volume , Plasma/diagnostic imaging , Polycythemia Vera/blood , Polycythemia Vera/diagnostic imaging , Adult , Aged , Aged, 80 and over , Algorithms , Blood Volume Determination/standards , Body Composition , Chromates/blood , Guidelines as Topic , Humans , Image Interpretation, Computer-Assisted/standards , Isotope Labeling/methods , Middle Aged , Polycythemia Vera/physiopathology , Radionuclide Imaging , Radiopharmaceuticals/blood , Reproducibility of Results , Sensitivity and Specificity , Sodium Compounds/blood
6.
Nucl Med Rev Cent East Eur ; 5(2): 121-5, 2002.
Article in English | MEDLINE | ID: mdl-14600870

ABSTRACT

BACKGROUND: The aim of this work was to estimate the significance of a dynamic study performed during the first 20 minutes after autologous (111)In-oxinate-platelets injection in patients with chronic immune thrombocytopenic purpura (ITP). Two hypotheses were tested: a) dynamic study indicates the place of platelet sequestration; b) dynamic study reflects the quality of platelet separation and labelling procedure. MATERIAL AND METHODS: Thirty-nine persons were investigated: 25 with shortened platelet life span (ITP), and 14 with normal platelet life span (6 healthy subjects and eight patients with myelodysplastic syndrome--MDS). Platelet blood count on the day of platelet labelling, general yield of platelet labelling (GYL), differential yield of platelet labelling (DYL), platelet life span, dynamic study with initial platelet accumulation in the liver (IPAL), sequential static study for determining the platelet sequestration index (SI) and platelet sequestration site (SS) were investigated. RESULTS: Two types of labelled platelet kinetics were determined in both groups of patients: IPAL < 20% and IPAL > 20%. A statistically significant difference in GYL and DYL was noted between the patients with IPAL < 20% and IPAL > 20%. No significant difference was registered in platelet blood count, life span, SS and SI between the two groups of patients. Both yields of platelet labelling were higher in the group with IPAL < 20%. There was no correlation between IPAL and platelet SI, or between IPAL and platelet SS. CONCLUSIONS: Dynamic study with (111)In-platelets cannot predict platelet sequestration site in ITP patients, but it is a useful and sensitive method of platelet labelling procedure quality control.

SELECTION OF CITATIONS
SEARCH DETAIL
...