1.
Comput Methods Programs Biomed ; 198: 105795, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33160110

ABSTRACT

BACKGROUND AND OBJECTIVE: The paper presents a novel procedure based on 3D scanning and 3D modelling to automatically assess linear and volumetric measurements of an arm and to be further applied to patients affected by post breast cancer lymphedema. The aim is the creation of a virtual platform easily usable by medical personnel to get more objective evaluations during the lymphedema treatment. METHODS: The procedure is based on the 3D scanning of the arm using the Occipital Structure Sensor and an ad-hoc developed application, named Lym 3DLab. Lym 3DLab emulates the traditional measurement methods, which consist in taking manual circumference measurements or using the water displacement method. These measurements are also used to design the compression stockings, the typical orthopaedic device used for lymphedema treatment. A validation test has been performed to compare the measurements computed by Lym 3DLab with both water displacement and manual circumference measurements. Eight volunteers have been involved who are not affected by lymphedema. Furthermore, a specific usability test has been performed to evaluate the 3D scanning procedure by involving four physiotherapists. RESULTS: The comparison between the volumes has highlighted how all the 3D acquired models have their volumes inside a range of acceptability. This range has been defined by considering the sensitivity error of the tape measure used to measure the water displacement. The comparison between the perimeters of cross sections computed with Lym 3DLab and the circumference measurements has shown results that are very accurate with an average difference of 2 mm. The measure errors have been considered negligible by the medical personnel who have evaluated the proposed procedure more accurate than the traditional ones. The test with physiotherapists has shown a high level of usability of the whole virtual environment, but the 3D scanning procedure requires an appropriate training of the personnel to make the 3D acquisition as fast and efficient as possible. CONCLUSIONS: The achieved results and the physiotherapists' feedback allow planning a future test with patients affected by lymphedema in collaboration with the hospital. A further test has been planned to use the computed measurements to design orthopaedic compression stockings.


Subject(s)
Breast Neoplasms , Lymphedema , Arm , Humans
2.
Clin Chem Lab Med ; 40(5): 529-36, 2002 May.
Article in English | MEDLINE | ID: mdl-12113300

ABSTRACT

Soluble transferrin receptor (sTfR) is reported to be a reliable marker for the diagnosis of iron deficiency, especially when iron metabolism is influenced by inflammatory disorders such as infection, chronic inflammation and cancer-related anemia. In the present multicenter study the analytical performance of a recently introduced, latex-enhanced immunoturbidimetric assay for the determination of soluble transferrin receptor (Tina quant [a] sTfR, Roche Diagnostics) on different fully mechanized analyzers such as Hitachi 917 and 911, and Cobas Integra 400 and 700 was evaluated. Within-run and between-run imprecision showed good results (CV<5% and <7%, respectively). The assay was found to be linear over a wide measuring range (0.4-35 mg/l). Endogenous substances did not interfere with the test results. Comparison of serum sTfR concentrations with those of heparinized plasma revealed good correlation (r>0.976). Method comparison with an existing fully mechanized method as well as with ELISA tests for sTfR showed very good correlation (r>0.987). Because of the lack of international standardization the results differed from each other up to 2.5-fold. The 95% of serum levels in healthy individuals ranged from 1.9 to 4.4 mg/l (n=427). However, the reference ranges should be reported in a sex-dependent manner, as 2.2-5.0 mg/l for men (n=211) and as 1.9-4.4 mg/l for premenopausal (n=216) and postmenopausal (n=45) women. The Tina quant [a] sTfR assay enables the precise, accurate, rapid and convenient determination of sTfR concentrations for routine clinical chemistry purposes.


Subject(s)
Nephelometry and Turbidimetry/methods , Receptors, Transferrin/blood , Adolescent , Adult , Aged , Anemia, Iron-Deficiency/diagnosis , Female , Hematologic Tests , Humans , Latex Fixation Tests/methods , Latex Fixation Tests/standards , Male , Middle Aged , Nephelometry and Turbidimetry/standards , Reference Values , Reproducibility of Results , Sex Factors , Solubility