Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Int Angiol ; 36(1): 64-68, 2017 Feb.
Article in English | MEDLINE | ID: mdl-26871393

ABSTRACT

BACKGROUND: Endovenous radiofrequency ablation (RFA) has been a viable treatment option for patients with saphenous varicose veins. The purpose of our study was to assess venous hemodynamic change before and after RFA by using air plethysmography (APG). METHODS: We prospectively analyzed the data of consecutive 91 patients with 124 limbs who underwent RFA for primary varicose veins. Overall venous hemodynamics of the limb was assessed using APG. The Venous Filling Index (VFI) was determined as a measure of reflux (normal range, <2 mL). Duplex scanning were performed to evaluate saphenous vein occlusion, deep venous thrombus and endovenous heat-induced thrombosis (EHIT). RESULTS: The VFI were significantly reduced from 4.1±3.1 preoperatively to 1.4±1.0, 1.3±0.8 and 1.4±1.2 at 1 week, 1 month and 4 month postoperatively, respectively. The percentage of the VFI >2 mL/s was 77% preoperatively, while it significantly decreased to 17%, 16%, and 18% at 1 week, 1 month, and 4 month postoperatively, respectively. Duplex scanning showed 100% of saphenous vein occlusion and no significant EHIT II-IV. CONCLUSIONS: Correction or significant improvement of venous reflux was achieved by RFA. Together with duplex scanning findings, RFA is a safe and hemodynamically effective treatment for varicose veins.


Subject(s)
Catheter Ablation , Hemodynamics , Saphenous Vein/surgery , Varicose Veins/surgery , Adult , Aged , Aged, 80 and over , Female , Humans , Japan , Male , Middle Aged , Plethysmography , Prospective Studies , Saphenous Vein/diagnostic imaging , Treatment Outcome , Ultrasonography, Doppler, Duplex , Varicose Veins/diagnostic imaging
2.
Int Angiol ; 36(3): 237-242, 2017 Jun.
Article in English | MEDLINE | ID: mdl-27575330

ABSTRACT

BACKGROUND: We aimed to review 50 consecutive Japanese abdominal aortic aneurysm (AAA) and common iliac aneurysm (CIAA) patients to evaluate the 2-year outcomes, particularly endoleak and aneurysm sac shrinkage, of the Endurant stent graft. METHODS: Between June 2012 and January 2014, 50 consecutive Japanese AAA and CIAA patients underwent EVAR with the Endurant stent graft. Clinical outcomes of overall survival, aneurysm-related survival, and secondary intervention-free survival were analyzed; endoleaks and aneurysm sac changes were also evaluated. RESULTS: The 2-year Kaplan-Meier estimates for overall survival, aneurysm-related survival, and secondary intervention-free survival were 85.4%, 97.7% with one device-related death, and 84.9%, respectively. Type I, II, and III endoleaks at any one point (all comers) after EVAR were detected in 2 (4%), 6 (12%), and 3 (6%) patients, respectively, whereas type IV endoleak was detected in 19 (38%) patients. The percentage of patients with significant sac shrinkage was only 19% (7/37) of the patients at 2 years. Multivariate analysis detected hypertension as a significant factor affecting aneurysm sac shrinkage (OR: 0.09, 95% CI: 0.001-0.99, P=0.049). CONCLUSIONS: The Endurant stent graft has demonstrated consistently successful clinical performance in Japanese patients for 2 years. However, the incidence of type IV endoleak was high, while the percentage of significant sac shrinkage was low. Careful and longer follow-up is required to determine the durability of the Endurant stent graft in Japanese patients.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation , Endoleak/epidemiology , Iliac Aneurysm/surgery , Stents , Aged , Aged, 80 and over , Aorta, Abdominal/physiopathology , Endovascular Procedures , Female , Humans , Japan , Kaplan-Meier Estimate , Male , Middle Aged , Multivariate Analysis , Postoperative Complications , Prospective Studies , Prosthesis Design , Reoperation , Tomography, X-Ray Computed , Transducers, Pressure , Treatment Outcome
3.
Int J Cardiol ; 220: 192-5, 2016 Oct 01.
Article in English | MEDLINE | ID: mdl-27379922

ABSTRACT

BACKGROUND: Postoperative fluid overload following cardiac surgery is associated with increased morbidity and mortality. Unlike loop diuretics, tolvaptan (TLV) promotes aquaretic effect. Relatively little has been documented regarding the efficacy of TLV after cardiac surgery. The aim of the study was to investigate the effectiveness and safety of tolvaptan for the management of immediately postoperative fluid retention following cardiac surgery. METHODS: Between January to May 2014, patients undergoing cardiac surgery were randomly assigned to control or TLV group immediately after cardiac surgery. In control group, patients received 20mg of furosemide and 25mg of spironolactone as conventional diuretics. In the TLV group, 7.5mg of TLV was administered in combination with conventional diuretics. RESULTS: TLV use was associated with increased urine output from postoperative day 1 to 3.Body weight reduction in the TLV group was significantly greater than the control group from postoperative day 2 to 4, and serum creatinine levels decreased to below preoperative values in the TLV group. CONCLUSIONS: The combination of tolvaptan with conventional diuretics increases urine output without renal dysfunction and can be effective for postoperative fluid management and appropriate body weight reduction.


Subject(s)
Benzazepines , Cardiac Surgical Procedures/adverse effects , Fluid Shifts/drug effects , Furosemide , Postoperative Complications , Spironolactone , Aged , Antidiuretic Hormone Receptor Antagonists/administration & dosage , Antidiuretic Hormone Receptor Antagonists/adverse effects , Benzazepines/administration & dosage , Benzazepines/adverse effects , Body Weight/drug effects , Body Weight/physiology , Cardiac Surgical Procedures/methods , Diuretics/administration & dosage , Diuretics/adverse effects , Drug Monitoring , Drug Therapy, Combination/methods , Female , Furosemide/administration & dosage , Furosemide/adverse effects , Humans , Male , Middle Aged , Postoperative Complications/diagnosis , Postoperative Complications/drug therapy , Postoperative Complications/etiology , Postoperative Complications/physiopathology , Spironolactone/administration & dosage , Spironolactone/adverse effects , Tolvaptan , Treatment Outcome , Urinalysis/methods
4.
J Artif Organs ; 19(2): 175-8, 2016 Jun.
Article in English | MEDLINE | ID: mdl-26463178

ABSTRACT

Sternal instability or dehiscence results in serious sternal wound infection. We sought to assess the early outcomes with such a plating system for sternal closure in comparison to the conventional wiring technique in off-pump coronary artery bypass grafting (CABG). Patients who underwent off-pump CABG were enrolled. Thirty-one patients received plate sternal fixation. A total of 64 patients who underwent off-pump CABG by a single surgeon at our hospital from July 2013 to December 2014 were enrolled. Thirty-one patients received plate sternal fixation (Plate group), while 33 received conventional wire closure (Wire group). The early outcomes, including the pain score and analgesic usage count were compared. Dietary intake was also recorded to assess the duration of appetite loss. At discharge, the largest sternal displacement was measured on computed tomography. In the Plate group, the pain scores were significantly lower on post-operative day 5-8 and POD 9-12 from those in the Wire group. The analgesic usage count on POD 9-12 was significantly lower in the Plate group. The duration of appetite loss and hospital stay was significantly shorter in the Plate group. The displacement in both the anterior-posterior and lateral directions was significantly smaller in the Plate group. Sternal closure by rigid plate fixation contributes to a more rapid post-operative recovery through reduced pain.


Subject(s)
Fracture Fixation, Internal/methods , Sternotomy , Aged , Aged, 80 and over , Bone Plates , Bone Wires , Coronary Artery Bypass, Off-Pump , Female , Humans , Male , Middle Aged , Retrospective Studies , Sternum/surgery , Treatment Outcome
5.
Int Angiol ; 35(5): 477-83, 2016 Oct.
Article in English | MEDLINE | ID: mdl-26344514

ABSTRACT

BACKGROUND: The purpose of this study was to analyze the risk factors for an adverse outcome after endovascular therapy (EVT) for critical limb ischemia (CLI) with tissue loss due to infrainguinal artery disease. METHODS: We retrospectively reviewed the charts of patients with tissue loss (Rutherford class 5 and 6) due to infrainguinal artery disease who were managed with endovascular therapy (EVT) between January 2006 and December 2013. The primary endpoint was amputation-free survival (AFS), while the secondary endpoints were freedom from a major adverse limb event (MALE) plus perioperative (30 days) death (POD), limb salvage, and survival rates at one year. Multivariable perioperative predictors of AFS were identified using the stepwise Cox proportional hazards regression model. RESULTS: A total of 65 patients underwent EVT for infrainguinal artery disease on 72 limbs. The technical success rate was 94% (68/72), while the clinical success was attained in 54 of 72 limbs (72%). The AFS, MALE + POD, limb salvage, and survival rates at one year were 76%, 86%, 91%, and 81%, respectively. The multivariate analysis demonstrated that major tissue loss classified as Rutherford class 6 (HR, 5.68; 95% CI, 2.29-14.13; P<0.05) was negatively associated with decreased AFS, while clinical success (HR, 0.25; 95% CI, 0.11-0.60; P<0.05) was positively associated with increased AFS. CONCLUSIONS: EVT resulted in an acceptable rate of AFS, MALE+POD, limb salvage, and survival. However, we must keep in mind that there are significant limitations to be considered for EVT in patients with major tissue loss, and that, even if revascularization could be successfully performed, a significant number of the treated limbs are still in a critical situation, such as major amputation or death.


Subject(s)
Endovascular Procedures/adverse effects , Ischemia/therapy , Peripheral Arterial Disease/therapy , Aged , Aged, 80 and over , Amputation, Surgical , Critical Illness , Disease-Free Survival , Endovascular Procedures/mortality , Female , Humans , Ischemia/diagnostic imaging , Ischemia/mortality , Kaplan-Meier Estimate , Limb Salvage , Male , Middle Aged , Multivariate Analysis , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/mortality , Proportional Hazards Models , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
6.
Thorac Cardiovasc Surg Rep ; 3(1): 71-2, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25798369

ABSTRACT

A 54-year-old man underwent aortic repair for the infected thoracoabdominal aneurysm with a woven Dacron graft (Vascutek, Renfrewshire, Scotland) treated with gentian violet. Four months later, he complained of sudden back pain, resulting in preshock status. Computed tomographic scans showed massive hematoma around the Dacron graft, suggesting graft rupture. Initially, emergency thoracic endovascular aortic repair was performed, which was subsequently followed by open repair. The Dacron graft had a small hole, which was completely compatible with the site contacting with the rib. The graft rupture was considered due to its friction against the rib. We report on a rare event of mechanical Dacron graft rupture after the thoracoabdominal aortic replacement.

7.
J Cardiol Cases ; 10(3): 94-96, 2014 Sep.
Article in English | MEDLINE | ID: mdl-30546516

ABSTRACT

Prosthetic graft infection in the ascending aorta or aortic arch is a life-threatening complication. Redo graft replacement is also associated with high mortality and morbidity rates. Conservative treatments without graft removal recently developed as alternatives to conventional surgical approach have been reported with successful outcomes. We report a case of successful treatment of prosthetic graft infection in the aortic arch, for which percutaneous catheter drainage was initially performed prior to open surgery, followed by graft coverage with an omental flap. .

8.
J Cardiol Cases ; 8(1): e1-e2, 2013 Jul.
Article in English | MEDLINE | ID: mdl-30546726

ABSTRACT

Heparin-induced thrombocytopenia (HIT) can often result in devastating thromboembolic outcomes. Argatroban is frequently administered as an alternative anticoagulant to heparin. We present a complicated case of HIT in which off-pump coronary artery bypass grafting was performed using anticoagulation with argatroban. Although the active clotting time was maintained between 220 and 270 s using argatroban, intraoperative thrombotic complications and postoperative prolonged coagulopathy were encountered. .

SELECTION OF CITATIONS
SEARCH DETAIL
...