Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Methods ; 224: 63-70, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38367653

ABSTRACT

Urinalysis is a useful test as an indicator of health or disease and as such, is a part of routine health screening. Urinalysis can be undertaken in many ways, one of which is reagent strips used in the general evaluation of health and to aid in the diagnosis and monitoring of kidney disease. To be effective, the test must be performed properly, and the results interpreted correctly. However, different light conditions and colour perception can vary between users leading to ambiguous readings. This has led to camera devices being used to capture and generate the estimated biomarker concentrations, but image colour can be affected by variations in illumination and inbuilt image processing. Therefore, a new portable device with embedded image processing techniques is presented in this study to provide quantitative measurements that are invariant to changes in illumination. The device includes a novel calibration process and uses the ratio of RGB values to compensate for variations in illumination across an image and improve the accuracy of quantitative measurements. Results show that the proposed calibration method gives consistent homogeneous illumination across the whole image. Comparisons against other existing methods and clinical results show good performance with a correlation to the clinical values. The proposed device can be used for point-of-care testing to provide reliable results consistent with clinical values.


Subject(s)
Point-of-Care Systems , Reagent Strips , Urinalysis/methods , Image Processing, Computer-Assisted
2.
Molecules ; 28(7)2023 Apr 05.
Article in English | MEDLINE | ID: mdl-37050007

ABSTRACT

Hydrogels have various promising prospects as a successful platform for detecting biomarkers, and human serum albumin (HSA) is an important biomarker in the diagnosis of kidney diseases. However, the difficult-to-control passive diffusion kinetics of hydrogels is a major factor affecting detection performance. This study focuses on using hydrogels embedded with aggregation-induced emission (AIE) fluorescent probe TC426 to detect HSA in real time. The vortex fluidic device (VFD) technology is used as a rotation strategy to control the reaction kinetics and micromixing during measurement. The results show that the introduction of VFD could significantly accelerate its fluorescence response and effectively improve the diffusion coefficient, while VFD processing could regulate passive diffusion into active diffusion, offering a new method for future sensing research.


Subject(s)
Fluorescent Dyes , Serum Albumin, Human , Humans , Spectrometry, Fluorescence/methods , Hydrogels
3.
Biosensors (Basel) ; 12(9)2022 Sep 04.
Article in English | MEDLINE | ID: mdl-36140108

ABSTRACT

Urine biomarkers are important in monitoring diseases related to human kidney function. The current processes for measuring biomarker levels in urine samples require patients to regularly visit clinical facilities, which is inconvenient and sometimes impossible for patients in rural areas. Therefore, portable analysis devices for the measurement of urine biomarkers are urgently requested. In this study, a portable platform using colorimetry, a common and simple-to-operate chemical analysis technique, was developed to measure urine biomarkers. The device, using commercial test kits as recognising reagents and a 96-well microplate as a solution container, provides quantitative measures of biomarker concentration. Moreover, the proposed device introduces a calibration method to minimise the dependence of regular maintenance. The device's performance was evaluated with urine from 73 renal patients and its results matched with clinical results well. The device has the potential for measuring urine creatinine, in addition to performing a variety of commercial assays for biomarker detection in human body fluids in general.


Subject(s)
Body Fluids , Colorimetry , Biomarkers/urine , Colorimetry/methods , Creatinine , Humans , Urinalysis
4.
Diagnostics (Basel) ; 11(7)2021 Jul 16.
Article in English | MEDLINE | ID: mdl-34359368

ABSTRACT

The detection and monitoring of biomarkers in body fluids has been used to improve human healthcare activities for decades. In recent years, researchers have focused their attention on applying the point-of-care (POC) strategies into biomarker detection. The evolution of mobile technologies has allowed researchers to develop numerous portable medical devices that aim to deliver comparable results to clinical measurements. Among these, optical-based detection methods have been considered as one of the common and efficient ways to detect and monitor the presence of biomarkers in bodily fluids, and emerging aggregation-induced emission luminogens (AIEgens) with their distinct features are merging with portable medical devices. In this review, the detection methodologies that use optical measurements in the POC systems for the detection and monitoring of biomarkers in bodily fluids are compared, including colorimetry, fluorescence and chemiluminescence measurements. The current portable technologies, with or without the use of smartphones in device development, that are combined with optical biosensors for the detection and monitoring of biomarkers in body fluids, are also investigated. The review also discusses novel AIEgens used in the portable systems for the detection and monitoring of biomarkers in body fluid. Finally, the potential of future developments and the use of optical detection-based portable devices in healthcare activities are explored.

5.
Micromachines (Basel) ; 12(8)2021 Aug 12.
Article in English | MEDLINE | ID: mdl-34442577

ABSTRACT

Inspired by the fundamental mechanics of an ancient whirligig (or buzzer toy; 3300 BC), a hand-driven rotational triboelectric nanogenerator (HDR-TENG) was designed and optimised, guided by our recently reported mathematical modelling. This modelling indicates that the power generated by HDR-TENG is a function of the number of segments, rotational speed, and tribo-surface spacing with different weighting sensitivities. Based on the simulation results, additive manufacturing technology was combined with commercially available components to cost-effectively fabricate the HDR-TENG. The fabricated HDR-TENG can provide stable and adjustable rotational speed up to 15,000 rpm with a linear hand stretching. The output voltage of HDR-TENG maintains a constant value within 50,000 cycles of testing when using Nylon 66 and PTFE as the triboelectric material. It can charge a 47 µF capacitor to 2.2 V in one minute. This study provides a cost-effective portable HDR-TENG device with adjustable high rotational speed, high power output, and long durable life, creating opportunities to provide a power supply for point-of-care devices in remote or resource-poor settings and applications in science and engineering education.

SELECTION OF CITATIONS
SEARCH DETAIL
...