Results 1 - 20 de 44
Filter
1.
J Bone Joint Surg Am ; 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38941476

ABSTRACT

BACKGROUND: Radiostereometric analysis (RSA) provides highly accurate data about the migration of a total knee arthroplasty (TKA) component. However, patient-reported outcome measures (PROMs) reflect the patients' perspective of their functional status, pain, and overall health after TKA. The aim of this study was to evaluate the association between tibial implant migration and change in postoperative PROMs and clinical scores, using data pooled from long-term follow-up RSA studies. METHODS: Individual implant migration data were collected from 5 randomized RSA studies, including a total of 300 patients with 6 distinct TKA implant designs (all Stryker). Tibial implant migration (maximum total point motion [MTPM]) was evaluated with RSA at 3 months, 1 year, and 2, 5, 7, and 10 years postoperatively. The Knee Society Score (KSS)-Knee and KSS-Function and Knee Injury and Osteoarthritis Outcome Score (KOOS) subscales were collected in all studies at the same follow-up times. Linear mixed-effects models, with adjustment for TKA implant design and patient characteristics, were used to analyze the data. The 3-month follow-up visit was used as the baseline to assess the association between implant migration and PROMs across the 10-year follow-up. RESULTS: No association between tibial implant migration and change in KSS-Knee (p = 0.384), KSS-Function (p = 0.737), KOOS-Symptoms (p = 0.398), KOOS-Pain (p = 0.699), KOOS-Activities of Daily Living (p = 0.205), KOOS-Sport and Recreation (p = 0.702), or KOOS-Quality of Life (p = 0.368) was found across the entire follow-up. Similar results were found when using the 2-year follow-up as the baseline, after which both cemented and uncemented implants are expected to have stabilized. CONCLUSIONS: Tibial baseplate migration was not associated with postoperative worsening in PROMs or clinical scores in patients who underwent TKA. These findings suggest that implant migration, as measured with RSA, measures a different parameter (i.e., implant-bone fixation) than PROMs (i.e., patient perception) and clinical scores. Therefore, to assess the performance and safety of TKA implant designs, RSA and PROMs cannot be used interchangeably during the postoperative follow-up of patients and evaluation of the fixation of knee implants. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

2.
Acta Orthop ; 95: 157-165, 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38597226

ABSTRACT

BACKGROUND AND PURPOSE:  Different marker-selection methods are applied to represent implant and tibial segments in radiostereometric analysis (RSA) studies of total knee arthroplasty (TKA). Either a consistent set of markers throughout subsequent RSA examinations ("consistent-marker method") is used or all available markers at each follow-up ("all-marker method"). The aim of this secondary analysis was to compare marker-selection methods on individual and group level TKA migration results. METHODS:  Data from a randomized RSA study with 72 patients was included. Tibial baseplate migration was evaluated at 3 months, 1, 2, and 5 years postoperatively with both marker-selection methods. Additionally, migration was calculated using 5 fictive points, either plotted based on the consistent set of markers or all available markers. RESULTS:  Migration could be calculated with both marker-selection methods for 248 examinations. The same prosthesis and bone markers (n = 136), different prosthesis markers (n = 71), different bone markers (n = 21), or different prosthesis and bone markers (n = 20) were used. The mean difference in maximum total point motion (MTPM) between all examinations was 0.02 mm, 95% confidence interval -0.26 to 0.31 mm. 5 implants were classified as continuously migrating with the consistent-marker method versus 6 implants (same 5 plus one additional implant) with the all-marker method. Using fictive points, fewer implants were classified as continuously migrating in both marker-selection methods. Differences between TKA groups in mean MTPM were comparable with both marker-selection methods, also when fictive points were used. CONCLUSION:  Estimated group differences in mean MTPM were similar between marker-selection methods, but individual migration results differed. The latter has implications when classifying implants for estimated risk of future loosening.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Follow-Up Studies , Radiostereometric Analysis , Prosthesis Failure , Prosthesis Design , Osteoarthritis, Knee/surgery
3.
Bone Joint J ; 106-B(2): 136-143, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38295835

ABSTRACT

Aims: The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface. Methods: Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem. Implant migration was measured using radiostereometric analysis (RSA), with radiographs taken within two days of surgery (baseline), and at three, 12, and 24 months postoperatively. Proximal acetabular component migration was the primary outcome measure. Clinical scores and patient-reported outcome measures (PROMs) were collected at each follow-up. Results: Mean proximal migrations at three, 12, and 24 months were 0.08 mm (95% confidence interval (CI) 0.03 to 0.14), 0.11 mm (95% CI 0.06 to 0.16), and 0.14 mm (95% CI 0.09 to 0.20), respectively, in the Trident II HA group, versus 0.11 mm (95% CI 0.06 to 0.16), 0.12 mm (95% CI 0.07 to 0.17), and 0.14 mm (95% CI 0.09 to 0.19) in the Trident HA group (p = 0.875). No significant differences in translations or rotations between the two designs were found in any other direction. Clinical scores and PROMs were comparable between groups, except for an initially greater postoperative improvement in Hip disability and Osteoarthritis Outcome Symptoms score in the Trident HA group (p = 0.033). Conclusion: The Trident II clusterhole HA shell has comparable migration with its predecessor, the Trident hemispherical HA cluster shell, suggesting a similar risk of long-term aseptic loosening.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Durapatite , Radiostereometric Analysis , Titanium , Follow-Up Studies , Prosthesis Design , Prosthesis Failure , Treatment Outcome
4.
J Bone Joint Surg Am ; 105(21): 1686-1694, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37651549

ABSTRACT

BACKGROUND: Three-dimensional (3D) printing of highly porous orthopaedic implants aims to promote better osseointegration, thus preventing aseptic loosening. However, short-term radiostereometric analysis (RSA) after total knee arthroplasty (TKA) has shown higher initial migration of cementless 3D-printed tibial components compared with their cemented counterparts. Therefore, critical evaluation of longer-term tibial component migration is needed. We investigated migration of a cementless 3D-printed and a cemented tibial component with otherwise similar TKA design during 5 years of follow-up, particularly the progression in migration beyond 2 years postoperatively. METHODS: Seventy-two patients were randomized to a cementless 3D-printed Triathlon Tritanium (Stryker) cruciate-retaining (CR) TKA or a cemented Triathlon CR (Stryker) TKA implant. Implant migration was evaluated with RSA at baseline and postoperatively at 3 months and at 1, 2, and 5 years. The maximum total point motion (MTPM) of the tibial component was compared between the groups at 5 years, and progression in migration was assessed between 2 and 5 years. Individual implants were classified as continuously migrating if the MTPM was ≥0.1 mm/year beyond 2 years postoperatively. Clinical scores were evaluated, and a linear mixed-effects model was used to analyze repeated measurements. RESULTS: At 5 years, the mean MTPM was 0.66 mm (95% confidence interval [CI], 0.56 to 0.78 mm) for the cementless group and 0.53 mm (95% CI, 0.43 to 0.64 mm) for the cemented group (p = 0.09). Between 2 and 5 years, there was no progression in mean MTPM for the cementless group (0.02 mm; 95% CI, -0.06 to 0.10 mm) versus 0.07 mm (95% CI, 0.00 to 0.14) for the cemented group. One implant was continuously migrating in the cementless group, and 4 were continuously migrating in the cemented group. The clinical scores were comparable between the groups across the entire time of follow-up. CONCLUSIONS: No significant difference in mean migration was found at 5 years between the cementless and cemented TKA implants. Progression of tibial component migration was present beyond 2 years for the cemented implant, whereas the cementless implant remained stable after initial early migration. LEVEL OF EVIDENCE: Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Radiostereometric Analysis/methods , Osteoarthritis, Knee/surgery , Bone Cements/therapeutic use , Printing, Three-Dimensional , Prosthesis Failure , Prosthesis Design , Treatment Outcome
5.
Acta Orthop ; 93: 271-276, 2022 01 24.
Article in English | MEDLINE | ID: mdl-35099566

ABSTRACT

BACKGROUND AND PURPOSE: In total knee arthroplasty (TKA), metal-backed (MBT) and all-polyethylene (APT) designs have shown comparable implant migration up to 2 years postoperatively using radiostereometric analysis (RSA). However, studies comparing mid-term migration of both designs are lacking. Furthermore, continuously migrating TKAs up to 2 years may continue to migrate or stabilize thereafter. Therefore, we compared 5-year migration of MBT and APT using either cruciate-stabilizing (CS) or posteriorstabilizing (PS) designs and specifically assessed migration profiles of continuously migrating TKAs beyond 2 years. PATIENTS AND METHODS: The present study includes results from 2 randomized trials comparing migration of cemented MBT with APT of either CS (CS study, n = 59) or PS (PS study, n = 56) design. 2 surgeons performed all surgeries. We used a linear mixed model for the analyses. RESULTS: The overall migration between MBT and APT TKAs was similar for either the CS or PS design over a 5-year period. In both studies combined, 9 implants showed continuous migration in the second postoperative year, of which 1 (APT-CS) was revised for instability, 4 (2 MBT-CS, MBT-PS, APT-PS) stabilized, and 4 (2 MBT-CS, APT-CS, MBT-PS) lacked 5-year data. INTERPRETATION: Overall migration was similar between MBT and APT TKAs up to 5 years, for both the CS and PS design. 4 initially migrating TKAs stabilized between 2- and 5-year follow-up, stressing the need for longer-term followup to determine whether second-year continuous migration correctly predicts loosening.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Follow-Up Studies , Humans , Knee Joint/surgery , Knee Prosthesis/adverse effects , Osteoarthritis, Knee/surgery , Prosthesis Design , Prosthesis Failure , Radiostereometric Analysis , Randomized Controlled Trials as Topic
6.
J Bone Joint Surg Am ; 103(24): 2281-2290, 2021 12 15.
Article in English | MEDLINE | ID: mdl-34648477

ABSTRACT

BACKGROUND: Orthopaedic surgeons aim for mechanical alignment when performing total knee arthroplasty (TKA) as malalignment is associated with loosening. Loosening may be predicted by migration as measured with radiostereometric analysis (RSA), but previous RSA studies on postoperative alignment have shown contradictory results and have been limited to cemented implants and small numbers of patients. Therefore, we performed a secondary analysis of 10 previously published randomized controlled trials (RCTs) to compare migration between postoperative in-range and out-of-range cemented and uncemented TKA implants among patients with a preoperative varus or valgus knee. METHODS: All RCTs involving the use of RSA that had been conducted at 2 centers were included. Alignment was classified, with use of the hip-knee-ankle angle (HKA), as in-range (0° ± 3°) or out-of-range (<-3° or >3°). The fixation methods included cemented, uncemented-coated, and uncemented-uncoated. Migration was measured at 3, 12, and 24 months. A linear mixed model was used, with adjustment for fixation method and clustering of patients within centers. RESULTS: Of 476 TKA implants that had been out-of-range preoperatively, 290 were in-range postoperatively and 186 were out-of-range in either varus (n = 143) or valgus (n = 43) postoperatively. The mean migration at 3, 12, and 24 months was 0.73 mm (95% confidence interval [CI], 0.66 to 0.79 mm), 0.92 mm (95% CI, 0.85 to 1.00 mm), and 0.97 mm (95% CI, 0.90 to 1.05 mm), respectively, for the in-range group and 0.80 mm (95% CI, 0.72 to 0.87 mm), 0.98 (95% CI, 0.90 to 1.07 mm), and 1.04 mm (95% CI, 0.95 to 1.13 mm), respectively, for the out-of-range group (p = 0.07). The fixation method significantly influenced migration, with uncemented-uncoated implants migrating more than cemented and uncemented-coated implants (p < 0.001). CONCLUSIONS: Postoperative alignment did not influence migration of TKAs in the first 2 postoperative years in patients with preoperative varus or valgus alignment of the knee. However, the fixation method significantly influenced migration, with uncemented-uncoated implants showing the greatest migration. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Bone Malalignment/complications , Knee Joint/physiopathology , Osteoarthritis, Knee/surgery , Prosthesis Failure , Aged , Arthroplasty, Replacement, Knee/instrumentation , Bone Malalignment/physiopathology , Female , Follow-Up Studies , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Knee Prosthesis/adverse effects , Male , Middle Aged , Radiostereometric Analysis , Randomized Controlled Trials as Topic , Risk Assessment , Risk Factors , Treatment Outcome
7.
J Bone Joint Surg Am ; 103(12): 1115-1124, 2021 06 16.
Article in English | MEDLINE | ID: mdl-33886528

ABSTRACT

BACKGROUND: Radiostereometric analysis (RSA) is a highly accurate tool to detect implant migration and predict loosening following total knee arthroplasty (TKA). However, little is known about the predisposing risk factors for implant migration, nor which migration profile should be considered physiological (i.e., merely part of an implant-settling phase) and which should be considered pathological (i.e., having a high probability for implant loosening). By pooling individual participant data from long-term follow-up RSA studies, we aimed to identify predisposing risk factors for tibial component loosening. METHODS: Individual data were collected for 630 patients from 11 RSA studies. The repeated measurements were analyzed with use of a linear mixed-effects model, determining the effect of age, sex, body mass index, diagnosis, preoperative and postoperative limb alignment, and prosthesis characteristics on tibial component migration over time, taking into account the clustering of patients within studies. RESULTS: High initial migration was found to result in early mechanical loosening in 18 cases (2.9%) and septic loosening in 2 cases (0.3%), whereas stabilization of high initial migration occurred in 17 cases (2.7%). Late loosening occurred in 13 cases (2.1%). All other 580 cases (92.1%) showed early stabilization and remained stable over time. Mixed-effects model analyses showed that for cemented prostheses, sex, diagnosis, and posterior cruciate ligament type had an effect on migration, but these differences were nonsignificant when analyzing migration from 3 months onwards. Uncemented prostheses aligned in varus showed more migration than neutrally and valgus-aligned TKAs (p = 0.031), and this difference increased over time (p < 0.001). Significantly higher migration was observed following uncemented TKA without an osseointegration-promoting surface (p < 0.001). CONCLUSIONS: For cemented prostheses, increased migration during the first 3 postoperative months was observed for female patients, patients with rheumatoid arthritis, and patients who underwent a posterior-stabilized TKA. For uncemented prostheses, both postoperative varus alignment of the lower limb and the absence of an osseointegration-promoting surface significantly increased postoperative tibial component migration. LEVEL OF EVIDENCE: Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/instrumentation , Knee Prosthesis , Prosthesis Failure , Follow-Up Studies , Humans , Osteoarthritis, Knee/surgery , Radiostereometric Analysis , Risk Factors , Tibia , Time Factors
8.
Bone Joint J ; 102-B(8): 1016-1024, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32731825

ABSTRACT

AIMS: Although bone cement is the primary mode of fixation in total knee arthroplasty (TKA), cementless fixation is gaining interest as it has the potential of achieving lasting biological fixation. By 3D printing an implant, highly porous structures can be manufactured, promoting osseointegration into the implant to prevent aseptic loosening. This study compares the migration of cementless, 3D-printed TKA to cemented TKA of a similar design up to two years of follow-up using radiostereometric analysis (RSA) known for its ability to predict aseptic loosening. METHODS: A total of 72 patients were randomized to either cementless 3D-printed or a cemented cruciate retaining TKA. RSA and clinical scores were evaluated at baseline and postoperatively at three, 12, and 24 months. A mixed model was used to analyze the repeated measurements. RESULTS: The mean maximum total point motion (MTPM) at three, 12, and 24 months was 0.33 mm (95% confidence interval (CI) 0.25 to 0.42), 0.42 mm (95% CI 0.33 to 0.51), and 0.47 mm (95% CI 0.38 to 0.57) respectively in the cemented group, versus 0.52 mm (95% CI 0.43 to 0.63), 0.62 mm (95% CI 0.52 to 0.73), and 0.64 mm (95% CI 0.53 to 0.75) in the cementless group (p = 0.003). However, using three months as baseline, no difference in mean migration between groups was found (p = 0.497). Three implants in the cemented group showed a > 0.2 mm increase in MTPM between one and two years of follow-up. In the cementless group, one implant was revised due to pain and progressive migration, and one patient had a liner-exchange due to a deep infection. CONCLUSION: The cementless TKA migrated more than the cemented TKA in the first two-year period. This difference was mainly due to a higher initial migration of the cementless TKA in the first three postoperative months after which stabilization was observed in all but one malaligned and early revised TKA. Whether the biological fixation of the cementless implants will result in an increased long-term survivorship requires a longer follow-up. Cite this article: Bone Joint J 2020;102-B(8):1016-1024.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Bone Cements/pharmacology , Osteoarthritis, Knee/surgery , Printing, Three-Dimensional , Prosthesis Failure , Radiostereometric Analysis/methods , Aged , Arthroplasty, Replacement, Knee/methods , Female , Follow-Up Studies , Foreign-Body Migration/surgery , Humans , Male , Middle Aged , Netherlands , Osteoarthritis, Knee/diagnostic imaging , Prosthesis Design , Reoperation/methods , Risk Assessment , Severity of Illness Index , Time Factors
9.
Acta Orthop ; 90(6): 590-595, 2019 12.
Article in English | MEDLINE | ID: mdl-31550947

ABSTRACT

Background and purpose - The all-polyethylene tibial (APT) component, introduced in the early 1970s, was surpassed by metal-backed tibial (MBT) trays as the first choice for total knee arthroplasty (TKA). With improved polyethylene, the modern APT components can reduce costs, and have shown equivalent results in survivorship and early migration of the cruciate-retaining and cruciate-stabilizing designs. This study compares the 2-year migration of a similarly designed APT-posterior stabilized (PS) and a MBT-PS TKA, using radiostereometric analysis (RSA).Patients and methods - 60 patients were randomized to receive either an APT Triathlon PS or an MBT Triathlon PS TKA (Stryker, NJ, USA). Migration measured by RSA and clinical scores were evaluated at baseline and at 3, 12, and 24 months postoperatively. Repeated measurements were analyzed with a linear mixed model and generalized estimating equations.Results - The mean maximum total point movement (MTPM) at 3, 12, and 24 months was 0.41 mm (95% CI 0.33-0.50), 0.57 mm (0.44-0.70), and 0.56 mm (0.42-0.69) respectively in the MBT group and 0.46 mm (0.36-0.57), 0.61 mm (0.49-0.73), and 0.64 mm (0.50-0.77) in the APT group. 2 MBT and 1 APT implant were considered unstable at the 2-year follow-up. The KSS Knee score and KSS Function across 3, 12, and 24 months were comparable in both groups.Interpretation - For an APT-PS designed component, MTPM measured with RSA is comparable to the MBT-PS component after 2 years of follow-up. No differences in complications or clinical outcomes were found.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Knee Joint/diagnostic imaging , Knee Prosthesis , Prosthesis Design , Radiostereometric Analysis , Aged , Female , Humans , Male , Patient Reported Outcome Measures , Polyethylene
10.
Acta Orthop ; 90(4): 366-372, 2019 08.
Article in English | MEDLINE | ID: mdl-31017513

ABSTRACT

Background and purpose - Pooling data of studies evaluating total knee arthroplasty migration using radiostereometric analysis (RSA) may be compromised when the RSA method used would influence estimated differences between groups. We therefore reanalyzed a marker-based RSA study with model-based RSA to assess possible limitations of each RSA method, including insert micromotions in modular TKA and their effect on estimated group differences. Patients and methods - All patients had received a cemented Triathlon implant (Stryker, Mahwah, NJ, USA) with either an all-polyethylene (n = 29) or a metal-backed (n = 28) tibial component. The latter group was reanalyzed with model-based RSA. Precision of each RSA method was calculated using double examinations. Bland-Altman plots were constructed to determine the limits of agreement between the 2 RSA methods. Polyethylene insert micromotion was quantified by measuring migration with respect to the metal tray. Finally, analyses of the original study were repeated with the model-based RSA results. Results - Systematic differences were found in translations between marker-based and model-based RSA as a result of different reference origins being used for migration calculations. Micromotions of the polyethylene insert within the metal tray were negligibly small. Mean migration results were comparable between marker-based and model-based RSA when using the same reference origin, even though conclusions on individual patients may differ between RSA methods due to various types of measurement error (e.g., marker occlusion and model-fit inaccuracies). Interpretation - At least for the studied TKA design, pooling mean migration data of different RSA methods appears justified. For translations, however, adjustments should be made to correct for differences in reference origin. Migration patterns of individual patients may differ as a result of distinct types of measurement error.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Knee Prosthesis/adverse effects , Prosthesis Failure , Biomarkers , Humans , Radiostereometric Analysis , Time Factors
11.
BMC Musculoskelet Disord ; 19(1): 341, 2018 Sep 22.
Article in English | MEDLINE | ID: mdl-30243296

ABSTRACT

BACKGROUND: Treatment of patients with knee osteoarthritis is challenging. Unloader braces have been developed with various success. Unloader One® Knee Brace is light, easily-fitted and shown to be effective by the unloading of the affected compartment. The aim of the study was to assess the clinical outcome of the brace vs. a placebo on patients with knee osteoarthritis. METHODS: Initially 150 patients were randomized to receive either the Unloader brace or a control placebo group look-alike brace where the active strips had been removed. The patients were followed up at 6,12,26 and 52 weeks with Knee Society Score (KSS) and Knee injury and Osteoarthritis Outcome Score (KOOS). The reason for dropout was recorded. RESULTS: A total of 149 patients were included, 74 in the study and 75 in the control group. The mean age was 59.6 vs. 60.2, BMI was 27.5 vs. 26.9, 37% vs. 44% were women in the study vs. control group. Both groups showed improvement in KSS over 52 weeks, with the study group showing higher improvement in mean scores. KSS increased from 64.3 to 84.0 for the study group and from 64.0 to 74.6 for the control group (p = 0.009). The study group improved in KSS function from 67.0 to 78.6 (p < 0.001) and KOOS for knee related symptoms increased/improved from 64.3 to 72.4 (p < 0.001). Activity of daily living increased/improved from 65.3 to 75.2 and Sports/Recreation from 24.6 to 40.2 (p > 0.001) whereas the control group did not show significant improvements in any of the scores. The dropout was higher in the control group, 40 vs. 25. CONCLUSIONS: The brace seems to be more effective and better tolerated than the placebo. TRIAL REGISTRATION: The trial was retrospectively registered with ClinicalTrials.gov ( NCT03454776 ) on March 6th 2018.


Subject(s)
Braces , Osteoarthritis, Knee/therapy , Aged , Female , Follow-Up Studies , Humans , Male , Middle Aged , Treatment Outcome
12.
Acta Orthop ; 89(4): 425-430, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29741133

ABSTRACT

Background and purpose - Biological fixation of uncemented knee prostheses can be improved by applying hydroxyapatite coating around the porous surface via a solution deposition technique called Peri-Apatite (PA). The 2-year results of a randomized controlled trial, evaluating the effect of PA, revealed several components with continuous migration in the second postoperative year, particularly in the uncoated group. To evaluate whether absence of early stabilization is diagnostic of loosening, we now present long-term follow-up results. Patients and methods - 60 patients were randomized to PA-coated or uncoated (porous only) total knee arthroplasty of which 58 were evaluated with radiostereometric analysis (RSA) performed at baseline, at 3 months postoperatively and at 1, 2, 5, 7, and 10 years. A linear mixed-effects model was used to analyze the repeated measurements. Results - PA-coated components had a statistically significantly lower mean migration at 10 years of 0.94 mm (95% CI 0.72-1.2) compared with the uncoated group showing a mean migration of 1.72 mm (95% CI 1.4-2.1). Continuous migration in the second postoperative year was seen in 7 uncoated components and in 1 PA-coated component. All of these implants stabilized after 2 years except for 2 uncoated components. Interpretation - Peri-apatite enhances stabilization of uncemented components. The number of components that stabilized after 2 years emphasizes the importance of longer follow-up to determine full stabilization and risk of loosening in uncemented components with biphasic migration profiles.


Subject(s)
Coated Materials, Biocompatible/therapeutic use , Durapatite/therapeutic use , Foreign-Body Migration/etiology , Prosthesis Failure , Aged , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Bone Cements/therapeutic use , Female , Humans , Knee Prosthesis , Male , Osteoarthritis, Knee/surgery , Prosthesis Design , Radiostereometric Analysis , Tibia/surgery , Treatment Outcome
13.
Acta Orthop ; 89(4): 412-417, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29714073

ABSTRACT

Background and purpose - With a rapidly increasing population in need of total knee arthroplasty (TKA), there is renewed interest in cost-saving all-polyethylene designs. Differences between metal-backed and all-polyethylene designs in initial component migration assessed by radiostereometric analysis (RSA), a proven predictor for late aseptic loosening, have been scantily reported. The purpose of this study was to compare implant migration and clinical outcomes of all-polyethylene tibial components versus metal-backed trays of similar geometrical shape. Patients and methods - In this randomized controlled trial, 59 patients received a cemented Triathlon condylar-stabilizing implant (Stryker, Mahwah, NJ, USA) with either an all-polyethylene (n = 29) or a metal-backed tibial component (n = 30). RSA measurements and clinical scores (the Knee Society Score, Forgotten Joint Score, and Knee Osteoarthritis and Injury Outcome Score) were evaluated at baseline and postoperatively at 3, 12, and 24 months. A linear mixed-effects model was used to analyze the repeated measurements. Results - A statistically significant difference in mean migration after 2 years was found in favor of the all-polyethylene group, with a mean maximum total point motion of 0.61 mm (95% CI 0.49-0.74) versus 0.81 mm (95% CI 0.68-0.96) for the cemented group (p = 0.03). However, this difference was smaller and not statistically significant after post hoc adjustment for surgeon effect. Both groups showed comparable improvements on all clinical outcome scores over time. Interpretation - The Triathlon all-polyethylene tibial component showed less migration, suggesting a lower risk of late loosening as compared with its metal-backed counterpart. However, the found surgeon effect warrants further investigation.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Foreign-Body Migration/etiology , Knee Prosthesis , Polyethylene , Prosthesis Failure , Aged , Arthroplasty, Replacement, Knee/methods , Bone Cements/therapeutic use , Female , Humans , Male , Osteoarthritis, Knee/surgery , Prosthesis Design , Radiostereometric Analysis , Risk Factors , Treatment Outcome
14.
Knee Surg Sports Traumatol Arthrosc ; 25(3): 902-909, 2017 Mar.
Article in English | MEDLINE | ID: mdl-26170187

ABSTRACT

PURPOSE: The purpose was to describe physical activity with respect to leisure and working activity in patients operated on by high tibial osteotomy using the hemicallotasis technique for knee osteoarthritis (OA), preoperatively and 10 years postoperatively. METHODS: Seventy-nine patients, median age 55 (range 35-66), operated on by high tibial osteotomy using the hemicallotasis technique for knee OA 2001-2003 were included. Questionnaires for evaluation of physical and working activity, satisfaction as well as the Knee injury and Osteoarthritis Outcome Score (KOOS) were filled in preoperatively and 2 and 10 years postoperatively. Conversion to knee arthroplasty was obtained through the Swedish Knee Arthroplasty Register. Changes between two postoperative measurements were assessed by Wilcoxon's rank test. RESULTS: Twenty-five patients were converted to a total knee arthroplasty, and nine patients were lost to follow-up during the 10 years, resulted in 45 patients available for follow-up. Preoperatively, 33/45 patients were physically active mainly in heavy yard/household work, and 43/45 patients were working active. Ten years after the HCO, 23/45 patients were still active with golf, dancing, hiking, etc., and 23/45 were retired. At 10 years postoperatively compared to 2 years postoperatively, the patients experienced more problems with pain (89 compared to 69, p = <0.0001). Of 45 patients, 36 were satisfied with the high tibial osteotomy surgery in general 10 years postoperatively, while 13/45 were satisfied with their sport and recreational function. CONCLUSIONS: The 10-year results indicate that high tibial osteotomy using the hemicallotasis technique for knee OA is an option for selected patients that improves the level of physical activity, with mild deterioration over time, and gives the majority of the patients the possibility to be working active until retirement. LEVEL OF EVIDENCE: Level IV.


Subject(s)
Exercise , Osteoarthritis, Knee/surgery , Osteotomy/methods , Tibia/surgery , Adult , Aged , Arthroplasty, Replacement, Knee , Female , Follow-Up Studies , Humans , Male , Middle Aged , Osteotomy/adverse effects , Pain/etiology , Patient Satisfaction , Postoperative Complications , Statistics, Nonparametric , Surveys and Questionnaires , Treatment Outcome
15.
Acta Orthop ; 87(3): 262-7, 2016 06.
Article in English | MEDLINE | ID: mdl-27088580

ABSTRACT

Background and purpose - There is a general call for phased introduction of new implants, and one step in the introduction is an early evaluation of micromotion. We compared the micromotion in the Triathlon and its predecessor, the Duracon total knee prosthesis, concentrating especially on continuous migration over 5 years of follow-up. Patients and methods - 60 patients were randomized to receive either a cemented Triathlon total knee prosthesis or a cemented Duracon total knee prosthesis. 3-D tibial component migration was measured by radiostereometric analysis (RSA) at 3 months and at 1, 2, and 5 years. Results - There was no statistically significant difference in maximum total point motion (MTPM) between the 2 groups (p = 0.1). The mean MTPM at 5 years for the Duracon was 1.10 (SD 1.21) mm and for the Triathlon it was 0.66 (SD 0.38) mm. The numbers of continuously migrating prostheses were similar in the groups at the fifth year of follow-up; 6 of 21 prostheses in the Duracon group and 3 of 21 in the Triathlon group had migrated more than 0.3 mm between the second year and the fifth year of follow-up (p = 0.2). Interpretation - The Triathlon has a micromotion pattern similar to that of the Duracon total knee system at both short-term and medium-term follow-up, and may therefore, over time, show the same good long-term mechanical stability.


Subject(s)
Radiostereometric Analysis , Treatment Outcome , Arthroplasty, Replacement, Knee , Follow-Up Studies , Humans , Knee Prosthesis , Prosthesis Design , Prosthesis Failure
16.
Acta Orthop ; 86(5): 594-8, 2015.
Article in English | MEDLINE | ID: mdl-25809183

ABSTRACT

BACKGROUND AND PURPOSE: A shortened tibial stem could influence the early prosthetic fixation. We therefore compared the short stem to the standard-length stem using radiostereometric analysis (RSA) as primary outcome measure. PATIENTS AND METHODS: 60 patients were randomized to receive a cemented Triathlon total knee arthroplasty (TKA) with a tibial tray of either standard or short stem length. The patients were blinded regarding treatment allocation. The micromotion of the tibial component was measured by RSA postoperatively, at 3 months, and after 1 and 2 years; clinical outcome was measured with the American Knee Society score (AKSS) and the knee osteoarthritis and injury outcome score (KOOS). RESULTS: The maximum total point motion (MTPM) for the standard stem was 0.36 (SD 0.16) mm at 3 months, 0.51 (SD 0.27) mm at 1 year, and 0.54 (SD 0.28) mm at 2 years. For the short stem, it was 0.42 (0.24) mm, 0.59 (0.43) mm, and 0.61 (0.39) mm. 4 short-stemmed components and 2 standard-stemmed components had more than 0.2 mm of migration between the first- and second-year follow-up, and were classified as continuously migrating. INTERPRETATION: The short-stemmed cemented tibial prosthesis showed an early prosthetic migratory pattern similar to that of the standard-stemmed cemented Triathlon knee prosthesis. The number of continuously migrating tibial plates in each group is predictive of a lower revision rate than 5% at 10 years.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Knee Prosthesis , Osteoarthritis, Knee/surgery , Prosthesis Design , Tibia , Female , Follow-Up Studies , Humans , Male , Osteoarthritis, Knee/diagnostic imaging , Prospective Studies , Radiostereometric Analysis/methods , Severity of Illness Index , Treatment Outcome
17.
Knee ; 22(2): 126-30, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25648580

ABSTRACT

BACKGROUND: Thigh tourniquet is commonly used in total knee arthroplasty (TKA) but may contribute to pain and muscle damage. Consequently, the reduction in knee-extension strength after TKA may be caused by quadriceps muscle ischaemia underneath the cuff. AIM: To examine if not using a thigh tourniquet during surgery was more effective than using a thigh tourniquet in preserving knee-extension strength 48 h after fast-track TKA. METHODS: A total of 64 patients undergoing TKA were randomized (1:1) to the use of tourniquet (T-group) or no tourniquet (NT-group). In the T-group the tourniquet cuff pressure was based on the patient's systolic pressure and a margin of 100 mm Hg. It was inflated immediately before surgery and deflated as soon as surgery ended. The primary outcome was the change in knee-extension strength from pre-surgery to 48 h after surgery (primary end point). Secondary outcomes were pain, nausea, length of hospital stay (LOS) and periarticular swelling. RESULTS: Knee-extension strength 48 h after surgery was substantially reduced by about 90% in both groups, with no statistically significant difference between groups (mean difference 1.5 N/kg, 95% CI 1.3-1.6). Among the secondary outcomes, the T-group had less bleeding during surgery (56 vs. 182 mL, P<0.01) compared with the NT-group. There was no difference in postoperative haemoglobin levels, pain, nausea, LOS or periarticular swelling between the groups. CONCLUSION: Not using a thigh tourniquet during surgery was not superior in preserving knee-extension strength at the primary endpoint 48 h after fast-track TKA, compared to using a tourniquet.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Blood Loss, Surgical/prevention & control , Knee Joint/surgery , Quadriceps Muscle/physiology , Tourniquets , Aged , Double-Blind Method , Female , Humans , Knee Joint/physiopathology , Male , Middle Aged , Osteoarthritis, Knee/surgery , Pain, Postoperative/drug therapy , Patient Satisfaction , Recovery of Function , Treatment Outcome
18.
Knee ; 21(5): 949-54, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24974301

ABSTRACT

OBJECTIVES: The objective of this study was to compare the early migration of the cruciate retaining and posterior stabilising versions of the recently introduced Triathlon™ total knee system, with a view to predicting long term fixation performance. METHODS: Sixty patients were prospectively randomised to receive either Triathlon™ posterior stabilised cemented knee prosthesis or Triathlon™ cruciate retaining cemented knee prosthesis. Tibial component migration was measured by radiostereometric analysis postoperatively and at three months, one year and two years. Clinical outcome was measured by the American Knee Society Score and Knee Osteoarthritis and Injury Outcome Score. RESULTS: There were no differences in rotation around the three coordinal axes or in the maximum total point motion (MTPM) during the two year follow-up. The posterior stabilised prosthesis had more posterior-anterior translation at three months and one year and more caudal-cranial translation at one year and two years. There were no differences in functional outcome between the groups. CONCLUSION: The tibial tray of the Triathlon™ cemented knee prosthesis showed similar early stability. LEVEL OF EVIDENCE: Level I. ARTICLE SUMMARY: Article focus: This was a prospective randomised trial aiming to compare the single radius posterior stabilised (PS) Triathlon™ total knee arthroplasty (TKA) to the cruciate retaining Triathlon™ TKA system with regard to fixation. Strengths and limitations of this study: Strength of this study was that it is a randomised prospective trial using an objective measuring tool. The sample size of 25-30 patients was reportedly sufficient for the screening of implants using RSA [1]. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00436982.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Knee Prosthesis/adverse effects , Osteoarthritis, Knee/surgery , Prosthesis Failure/adverse effects , Aged , Arthroplasty, Replacement, Knee/adverse effects , Cementation , Female , Follow-Up Studies , Gentamicins , Humans , Male , Methylmethacrylates , Middle Aged , Prospective Studies , Prosthesis Design , Time Factors , Treatment Outcome
19.
Knee ; 21(2): 396-401, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24238650

ABSTRACT

BACKGROUND: A concern that arises with any change in technique is whether it affects the long-term implant stability. The objective of this study was to evaluate the early migration, measured by radiostereometric analysis (RSA), and the functional outcome of the Triathlon™ cemented knee prosthesis, operated on with or without a tourniquet. During the last decades RSA has emerged as a way to assess prosthetic fixation and long time prognosis. The method has been used extensively in both hip and knee arthroplasty. METHOD: This was a single centre prospective study including 60 patients randomized into two groups operated on either with or without tourniquet. RSA investigation was done within 2-3 days postoperatively after full weight bearing, and then at 3 months, 1 year and 2 years postoperatively. RESULTS: There were no differences between the groups regarding the translation along or rotation around the three coordinal axes, or in maximum total point motion (MTPM). At 2 years the mean MTPM (SD) was 0.71 mm (0.64) for the tourniquet-group and 0.53 mm (0.21) for the non-tourniquet-group. CONCLUSIONS: The tibial tray of the Triathlon™ cemented knee prosthesis showed similar early stability whether operated on with or without tourniquet. LEVEL OF EVIDENCE: Level I. ARTICLE SUMMARY: Article focus: A safety study for total knee replacement operated on with or without perioperative tourniquet regarding the prosthetic fixation. Strengths and limitations: Strength of this study is that it is a randomized prospective trial using an objective measuring tool. The sample size of 25-30 patients is reportedly sufficient for the screening of implants using RSA (1-3). TRIAL REGISTRATION: Clinical trials NCT01604382, Ethics Committee approval D-nr: 144/20085.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Bone Cements , Knee Prosthesis , Tourniquets , Aged , Female , Follow-Up Studies , Humans , Knee Joint/physiopathology , Knee Joint/surgery , Male , Osteoarthritis, Knee/surgery , Prospective Studies , Radiostereometric Analysis , Range of Motion, Articular/physiology , Rotation
20.
Acta Orthop ; 84(3): 314-8, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23621808

ABSTRACT

BACKGROUND AND PURPOSE: External fixation pins tend to loosen with time, especially from cancellous bone. A coating that releases a bisphosphonate has been shown to improve the fixation of dental implants in humans. We now tested a bisphosphonate coating on steel pins for external fixation. The primary hypothesis was that coated pins would be better fixed in the diaphysis. METHODS: 20 patients with medial knee osteoarthritis underwent proximal tibial correction osteotomy with hemicallotasis. They received a pair of pins (Orthofix) in the tibial shaft, one bisphosphonate-coated and one uncoated. Another pair of pins was inserted in the metaphysis, near the joint. This pair was a bisphosphonate-coated pin and an HA-coated pin. All pins were inserted according to a random list. The pins were removed after the osteotomy had healed (8-15 weeks), and extraction torque served as the predetermined main outcome variable. RESULTS: No pins showed clinical signs of loosening. Removal torque for the shaft pins was 6.6 Nm (SD 2.2) for the bisphosphonate and 6.0 Nm (SD 2.5) for the uncoated (difference = 0.5, 95% CI: -0.03 to 1.3). Removal torque for the metaphyseal pins was 4.4 Nm (SD 1.3) for the bisphosphonate-coated and 4.2 Nm (SD 1.6) for the HA-coated (difference = 0.2, 95% CI: -0.5 to 1.0). INTERPRETATION: We could not show any improved cortical fixation, but the metaphyseal findings are striking. In a previous study on 19 patients with a similar layout, HA-coated and uncoated pins were compared. In the metaphysis, all 19 uncoated pins loosened before removal. It was concluded that uncoated pins could not be used in the metaphyseal region. The present results suggest that a bisphosphonate coating enables metaphyseal fixation similar to that of hydroxyapatite coatings, with no difference from uncoated pins in cortical bone.


Subject(s)
Bone Density Conservation Agents/administration & dosage , Bone Nails , Diphosphonates/administration & dosage , Osteoarthritis, Knee/surgery , Tibia/surgery , Coated Materials, Biocompatible , Device Removal , Durapatite , External Fixators , Humans , Osteogenesis, Distraction/methods , Osteotomy/instrumentation , Osteotomy/methods