Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 72
Filter
1.
Med Phys ; 51(5): 3195-3206, 2024 May.
Article in English | MEDLINE | ID: mdl-38513254

ABSTRACT

BACKGROUND: Percutaneous microwave ablation (pMWA) is a minimally invasive procedure that uses a microwave antenna placed at the tip of a needle to induce lethal tissue heating. It can treat cancer and other diseases with lower morbidity than conventional surgery, but one major limitation is the lack of control over the heating region around the ablation needle. Superparamagnetic iron oxide nanoparticles have the potential to enhance and control pMWA heating due to their ability to absorb microwave energy and their ease of local delivery. PURPOSE: The purpose of this study is to experimentally quantify the capabilities of FDA-approved superparamagnetic iron oxide Feraheme nanoparticles (FHNPs) to enhance and control pMWA heating. This study aims to determine the effectiveness of locally injected FHNPs in increasing the maximum temperature during pMWA and to investigate the ability of FHNPs to create a controlled ablation zone around the pMWA needle. METHODS: PMWA was performed using a clinical ablation system at 915 MHz in ex-vivo porcine liver tissues. Prior to ablation, 50 uL 5 mg/mL FHNP injections were made on one side of the pMWA needle via a 23-gauge needle. Local temperatures at the FHNP injection site were directly compared to equidistant control sites without FHNP. First, temperatures were compared using directly inserted thermocouples. Next, temperatures were measured non-invasively using magnetic resonance thermometry (MRT), which enabled comprehensive four-dimensional (volumetric and temporal) assessment of heating effects relative to nanoparticle distribution, which was quantified using dual-echo ultrashort echo time (UTE) subtraction MR imaging. Maximum heating within FHNP-exposed tissues versus control tissues were compared at multiple pMWA energy delivery settings. The ability to generate a controlled asymmetric ablation zone using multiple FHNP injections was also tested. Finally, intra-procedural MRT-derived heat maps were correlated with gold standard gross pathology using Dice similarity analysis. RESULTS: Maximum temperatures at the FHNP injection site were significantly higher than control (without FHNP) sites when measured using direct thermocouples (93.1 ± 6.0°C vs. 57.2 ± 8.1°C, p = 0.002) and using non-invasive MRT (115.6 ± 13.4°C vs. 49.0 ± 10.6°C, p = 0.02). Temperature difference between FHNP-exposed and control sites correlated with total energy deposition: 66.6 ± 17.6°C, 58.1 ± 8.5°C, and 20.8 ± 9.2°C at high (17.5 ± 2.2 kJ), medium (13.6 ± 1.8 kJ), and low (8.8 ± 1.1 kJ) energies, respectively (all pairwise p < 0.05). Each FHNP injection resulted in a nanoparticle distribution within 0.9 ± 0.2 cm radially of the injection site and a local lethal heating zone confined to within 1.1 ± 0.4 cm radially of the injection epicenter. Multiple injections enabled a controllable, asymmetric ablation zone to be generated around the ablation needle, with maximal ablation radius on the FHNP injection side of 1.6 ± 0.2 cm compared to 0.7 ± 0.2 cm on the non-FHNP side (p = 0.02). MRT intra-procedural predicted ablation zone correlated strongly with post procedure gold-standard gross pathology assessment (Dice similarity 0.9). CONCLUSIONS: Locally injected FHNPs significantly enhanced pMWA heating in liver tissues, and were able to control the ablation zone shape around a pMWA needle. MRI and MRT allowed volumetric real-time visualization of both FHNP distribution and FHNP-enhanced pMWA heating that was useful for intra-procedural monitoring. This work strongly supports further development of a FHNP-enhanced pMWA paradigm; as all individual components of this approach are approved for patient use, there is low barrier for clinical translation.


Subject(s)
Ablation Techniques , Magnetic Iron Oxide Nanoparticles , Microwaves , Thermometry , Animals , Thermometry/methods , Ablation Techniques/methods , Swine , Magnetic Resonance Imaging , Temperature , Liver/surgery , Liver/diagnostic imaging
2.
IEEE Trans Med Robot Bionics ; 5(2): 335-342, 2023 May.
Article in English | MEDLINE | ID: mdl-37312886

ABSTRACT

MR-guided focal cryoablation of prostate cancer has often been selected as a minimally-invasive treatment option. Placing multiple cryo-needles accurately to form an ablation volume that adequately covers the target volume is crucial for better oncological/functional outcomes. This paper presents an MRI-compatible system combining a motorized tilting grid template with insertion depth sensing capabilities, enabling the physician to precisely place the cryo-needles into the desired location. In vivo animal study in a swine model (3 animals) was performed to test the device performance including targeting accuracy and the procedure workflow. The study showed that the insertion depth feedback improved the 3D targeting accuracy when compared to the conventional insertion technique (7.4 mm vs. 11.2 mm, p=0.04). All three cases achieved full iceball coverage without repositioning the cryo-needles. The results demonstrate the advantages of the motorized tilting mechanism and real-time insertion depth feedback, as well as the feasibility of the proposed workflow for MRI-guided focal cryoablation of prostate cancer.

3.
Acad Radiol ; 30 Suppl 1: S14-S20, 2023 09.
Article in English | MEDLINE | ID: mdl-37236896

ABSTRACT

RATIONALE AND OBJECTIVES: Focal therapies have emerged as minimally invasive alternatives for patients with localized low-risk prostate cancer (PCa) and those with postradiation recurrence. Among the available focal treatment methods for PCa, cryoablation offers several technical advantages, including the visibility of the boundaries of frozen tissue on the intraprocedural images, access to anterior lesions, and the proven ability to treat postradiation recurrence. However, predicting the final volume of the frozen tissue is challenging as it depends on several patient-specific factors, such as proximity to heat sources and thermal properties of the prostatic tissue. MATERIALS AND METHODS: This paper presents a convolutional neural network model based on 3D-Unet to predict the frozen isotherm boundaries (iceball) resultant from a given a cryo-needle placement. Intraprocedural magnetic resonance images acquired during 38 cases of focal cryoablation of PCa were retrospectively used to train and validate the model. The model accuracy was assessed and compared against a vendor-provided geometrical model, which is used as a guideline in routine procedures. RESULTS: The mean Dice Similarity Coefficient using the proposed model was 0.79±0.08 (mean+SD) vs 0.72±0.06 using the geometrical model (P<.001). CONCLUSION: The model provided an accurate iceball boundary prediction in less than 0.4second and has proven its feasibility to be implemented in an intraprocedural planning algorithm.


Subject(s)
Cryosurgery , Prostatic Neoplasms , Male , Humans , Cryosurgery/methods , Retrospective Studies , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery , Algorithms , Artificial Intelligence
4.
Phys Med Biol ; 68(10)2023 05 15.
Article in English | MEDLINE | ID: mdl-37080237

ABSTRACT

Objective.Clinical outcomes of transperineal prostate interventions, such as biopsy, thermal ablations, and brachytherapy, depend on accurate needle placement for effectiveness. However, the accurate placement of a long needle, typically 150-200 mm in length, is challenging due to needle deviation induced by needle-tissue interaction. While several approaches for needle trajectory correction have been studied, many of them do not translate well to practical applications due to the use of specialized needles not yet approved for clinical use, or to relying on needle-tissue models that need to be tailored to individual patients.Approach.In this paper, we present a robot-assisted collaborative needle insertion method that only requires an actuated passive needle guide and a conventional needle. The method is designed to assist a physician inserting a needle manually through a needle guide. If the needle is deviated from the intended path, actuators shifts the needle radially in order to steer the needle trajectory and compensate for needle deviation adaptively. The needle guide is controlled by a new data-driven algorithm which does not requirea prioriinformation about needle or tissue properties. The method was evaluated in experiments with bothin vitroandex vivophantoms.Main results.The experiments inex vivotissue reported a mean final placement error of 0.36 mm with a reduction of 96.25% of placement error when compared to insertions without the use of assistive correction.Significance.Presented results show that the proposed closed-loop formulation can be successfully used to correct needle deflection during collaborative manual insertion with potential to be easily translated into clinical application.


Subject(s)
Needles , Prostate , Male , Humans , Biopsy , Pelvis , Algorithms
5.
Eur Radiol ; 33(1): 461-471, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35771247

ABSTRACT

OBJECTIVES: The Prostate Imaging Quality (PI-QUAL) score is a new metric to evaluate the diagnostic quality of multiparametric magnetic resonance imaging (MRI) of the prostate. This study assesses the impact of an intervention, namely a prostate MRI quality training lecture, on the participant's ability to apply PI-QUAL. METHODS: Sixteen participants (radiologists, urologists, physicists, and computer scientists) of varying experience in reviewing diagnostic prostate MRI all assessed the image quality of ten examinations from different vendors and machines. Then, they attended a dedicated lecture followed by a hands-on workshop on MRI quality assessment using the PI-QUAL score. Five scans assessed by the participants were evaluated in the workshop using the PI-QUAL score for teaching purposes. After the course, the same participants evaluated the image quality of a new set of ten scans applying the PI-QUAL score. Results were assessed using receiver operating characteristic analysis. The reference standard was the PI-QUAL score assessed by one of the developers of PI-QUAL. RESULTS: There was a significant improvement in average area under the curve for the evaluation of image quality from baseline (0.59 [95 % confidence intervals: 0.50-0.66]) to post-teaching (0.96 [0.92-0.98]), an improvement of 0.37 [0.21-0.41] (p < 0.001). CONCLUSIONS: A teaching course (dedicated lecture + hands-on workshop) on PI-QUAL significantly improved the application of this scoring system to assess the quality of prostate MRI examinations. KEY POINTS: • A significant improvement in the application of PI-QUAL for the assessment of prostate MR image quality was observed after an educational intervention. • Appropriate training on image quality can be delivered to those involved in the acquisition and interpretation of prostate MRI. • Further investigation will be needed to understand the impact on improving the acquisition of high-quality diagnostic prostate MR examinations.


Subject(s)
Multiparametric Magnetic Resonance Imaging , Prostatic Neoplasms , Male , Humans , Prostate/diagnostic imaging , Prostate/pathology , Fellowships and Scholarships , Prostatic Neoplasms/pathology , Magnetic Resonance Imaging/methods , Retrospective Studies
6.
Sensors (Basel) ; 22(14)2022 Jul 17.
Article in English | MEDLINE | ID: mdl-35891016

ABSTRACT

Developing image-guided robotic systems requires access to flexible, open-source software. For image guidance, the open-source medical imaging platform 3D Slicer is one of the most adopted tools that can be used for research and prototyping. Similarly, for robotics, the open-source middleware suite robot operating system (ROS) is the standard development framework. In the past, there have been several "ad hoc" attempts made to bridge both tools; however, they are all reliant on middleware and custom interfaces. Additionally, none of these attempts have been successful in bridging access to the full suite of tools provided by ROS or 3D Slicer. Therefore, in this paper, we present the SlicerROS2 module, which was designed for the direct use of ROS2 packages and libraries within 3D Slicer. The module was developed to enable real-time visualization of robots, accommodate different robot configurations, and facilitate data transfer in both directions (between ROS and Slicer). We demonstrate the system on multiple robots with different configurations, evaluate the system performance and discuss an image-guided robotic intervention that can be prototyped with this module. This module can serve as a starting point for clinical system development that reduces the need for custom interfaces and time-intensive platform setup.


Subject(s)
Robotics , Diagnostic Imaging , Reactive Oxygen Species , Software
7.
Magn Reson Med ; 88(4): 1818-1827, 2022 10.
Article in English | MEDLINE | ID: mdl-35713379

ABSTRACT

PURPOSE: To evaluate multicenter repeatability and reproducibility of T1 and T2 maps generated using MR fingerprinting (MRF) in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom and in prostatic tissues. METHODS: MRF experiments were performed on 5 different 3 Tesla MRI scanners at 3 different institutions: University Hospitals Cleveland Medical Center (Cleveland, OH), Brigham and Women's Hospital (Boston, MA) in the United States, and Diagnosticos da America (Rio de Janeiro, RJ) in Brazil. Raw MRF data were reconstructed using a Gadgetron-based MRF online reconstruction pipeline to yield quantitative T1 and T2 maps. The repeatability of T1 and T2 values over 6 measurements in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom was assessed to demonstrate intrascanner variation. The reproducibility between the 4 clinical scanners was assessed to demonstrate interscanner variation. The same-day test-retest normal prostate mean T1 and T2 values from peripheral zone and transitional zone were also compared using the intraclass correlation coefficient and Bland-Altman analysis. RESULTS: The intrascanner variation of values measured using MRF was less than 2% for T1 and 4.7% for T2 for relaxation values, within the range of 307.7 to 2360 ms for T1 and 19.1 to 248.5 ms for T2 . Interscanner measurements showed that the T1 variation was less than 4.9%, and T2 variation was less than 8.1% between multicenter scanners. Both T1 and T2 values in in vivo prostatic tissue demonstrated high test-retest reliability (intraclass correlation coefficient > 0.92) and strong linear correlation (R2  > 0.840). CONCLUSION: Prostate MRF measurements of T1 and T2 are repeatable and reproducible between MRI scanners at different centers on different continents for the above measurement ranges.


Subject(s)
Magnetic Resonance Imaging , Prostate , Brazil , Female , Humans , Image Processing, Computer-Assisted , Male , Phantoms, Imaging , Prostate/diagnostic imaging , Reproducibility of Results
8.
IEEE ASME Trans Mechatron ; 27(1): 407-417, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35185321

ABSTRACT

Brachytherapy is a radiation based treatment that is implemented by precisely placing focused radiation sources into tumors. In advanced interstitial cervical cancer bracytherapy treatment, this is performed by placing a metallic rod ("stylet") inside a hollow cylindrical tube ("catheter") and advancing the pair to the desired target. The stylet is removed once the target is reached, followed by the insertion of radiation sources into the catheter. However, manually advancing an initially straight stylet into the tumor with millimeter spatial accuracy has been a long-standing challenge, which requires multiple insertions and retractions, due to the unforeseen stylet deflection caused by the stiff muscle tissue that is traversed. In this paper, we develop a novel tendon-actuated deflectable stylet equipped with MR active-tracking coils that may enhance brachytherapy treatment outcomes by allowing accurate stylet trajectory control. Herein we present the design concept and fabrication method, followed by the kinematic and mechanics models of the deflectable stylet. The hardware and theoretical models are extensively validated via benchtop and MRI-guided characterization. At insertion depths of 60 mm, benchtop phantom targeting tests provided a targeting error of 1. 23 ± 0. 47 mm, and porcine tissue targeting tests provided a targeting error of 1. 65 ± 0. 64 mm, after only a single insertion. MR-guided experiments indicate that the stylet can be safely and accurately located within the MRI environment.

9.
Magn Reson Med ; 87(6): 2885-2900, 2022 06.
Article in English | MEDLINE | ID: mdl-35142398

ABSTRACT

PURPOSE: Develop a deflectable intracardiac MR imaging (ICMRI) guiding-sheath to accelerate imaging during MR-guided electrophysiological (EP) interventions for radiofrequency (500 kHz) ablation (RFA) of arrythmia. Requirements include imaging at three to five times surface-coil SNR in cardiac chambers, vascular insertion, steerable-active-navigation into cardiac chambers, operation with ablation catheters, and safe levels of MR-induced heating. METHODS: ICMRI's 6 mm outer-diameter (OD) metallic-braided shaft had a 2.6 mm OD internal lumen for ablation-catheter insertion. Miniature-Baluns (MBaluns) on ICMRI's 1 m shaft reduced body-coil-induced heating. Distal section was a folded "star"-shaped imaging-coil mounted on an expandable frame, with an integrated miniature low-noise-amplifier overcoming cable losses. A handle-activated movable-shaft expanded imaging-coil to 35 mm OD for imaging within cardiac-chambers. Four MR-tracking micro-coils enabled navigation and motion-compensation, assuming a tetrahedron-shape when expanded. A second handle-lever enabled distal-tip deflection. ICMRI with a protruding deflectable EP catheter were used for MR-tracked navigation and RFA using a dedicated 3D-slicer user-interface. ICMRI was tested at 3T and 1.5T in swine to evaluate (a) heating, (b) cardiac-chamber access, (c) imaging field-of-view and SNR, and (d) intraprocedural RFA lesion monitoring. RESULTS: The 3T and 1.5T imaging SNR demonstrated >400% SNR boost over a 4 × 4 × 4 cm3 FOV in the heart, relative to body and spine arrays. ICMRI with MBaluns met ASTM/IEC heating limits during navigation. Tip-deflection allowed navigating ICMRI and EP catheter into atria and ventricles. Acute-lesion long-inversion-time-T1-weighted 3D-imaging (TWILITE) ablation-monitoring using ICMRI required 5:30 min, half the time needed with surface arrays alone. CONCLUSION: ICMRI assisted EP-catheter navigation to difficult targets and accelerated RFA monitoring.


Subject(s)
Catheter Ablation , Magnetic Resonance Imaging , Animals , Arrhythmias, Cardiac , Catheter Ablation/methods , Equipment Design , Heart Atria , Magnetic Resonance Imaging/methods , Swine
10.
J Neurosurg ; 136(5): 1475-1484, 2022 May 01.
Article in English | MEDLINE | ID: mdl-34653985

ABSTRACT

OBJECTIVE: A major obstacle to improving bedside neurosurgical procedure safety and accuracy with image guidance technologies is the lack of a rapidly deployable, real-time registration and tracking system for a moving patient. This deficiency explains the persistence of freehand placement of external ventricular drains, which has an inherent risk of inaccurate positioning, multiple passes, tract hemorrhage, and injury to adjacent brain parenchyma. Here, the authors introduce and validate a novel image registration and real-time tracking system for frameless stereotactic neuronavigation and catheter placement in the nonimmobilized patient. METHODS: Computer vision technology was used to develop an algorithm that performed near-continuous, automatic, and marker-less image registration. The program fuses a subject's preprocedure CT scans to live 3D camera images (Snap-Surface), and patient movement is incorporated by artificial intelligence-driven recalibration (Real-Track). The surface registration error (SRE) and target registration error (TRE) were calculated for 5 cadaveric heads that underwent serial movements (fast and slow velocity roll, pitch, and yaw motions) and several test conditions, such as surgical draping with limited anatomical exposure and differential subject lighting. Six catheters were placed in each cadaveric head (30 total placements) with a simulated sterile technique. Postprocedure CT scans allowed comparison of planned and actual catheter positions for user error calculation. RESULTS: Registration was successful for all 5 cadaveric specimens, with an overall mean (± standard deviation) SRE of 0.429 ± 0.108 mm for the catheter placements. Accuracy of TRE was maintained under 1.2 mm throughout specimen movements of low and high velocities of roll, pitch, and yaw, with the slowest recalibration time of 0.23 seconds. There were no statistically significant differences in SRE when the specimens were draped or fully undraped (p = 0.336). Performing registration in a bright versus a dimly lit environment had no statistically significant effect on SRE (p = 0.742 and 0.859, respectively). For the catheter placements, mean TRE was 0.862 ± 0.322 mm and mean user error (difference between target and actual catheter tip) was 1.674 ± 1.195 mm. CONCLUSIONS: This computer vision-based registration system provided real-time tracking of cadaveric heads with a recalibration time of less than one-quarter of a second with submillimetric accuracy and enabled catheter placements with millimetric accuracy. Using this approach to guide bedside ventriculostomy could reduce complications, improve safety, and be extrapolated to other frameless stereotactic applications in awake, nonimmobilized patients.

11.
Sci Rep ; 11(1): 11480, 2021 06 01.
Article in English | MEDLINE | ID: mdl-34075061

ABSTRACT

Preoperative assessment of the proximity of critical structures to the tumors is crucial in avoiding unnecessary damage during prostate cancer treatment. A patient-specific 3D anatomical model of those structures, namely the neurovascular bundles (NVB) and the external urethral sphincters (EUS), can enable physicians to perform such assessments intuitively. As a crucial step to generate a patient-specific anatomical model from preoperative MRI in a clinical routine, we propose a multi-class automatic segmentation based on an anisotropic convolutional network. Our specific challenge is to train the network model on a unique source dataset only available at a single clinical site and deploy it to another target site without sharing the original images or labels. As network models trained on data from a single source suffer from quality loss due to the domain shift, we propose a semi-supervised domain adaptation (DA) method to refine the model's performance in the target domain. Our DA method combines transfer learning and uncertainty guided self-learning based on deep ensembles. Experiments on the segmentation of the prostate, NVB, and EUS, show significant performance gain with the combination of those techniques compared to pure TL and the combination of TL with simple self-learning ([Formula: see text] for all structures using a Wilcoxon's signed-rank test). Results on a different task and data (Pancreas CT segmentation) demonstrate our method's generic application capabilities. Our method has the advantage that it does not require any further data from the source domain, unlike the majority of recent domain adaptation strategies. This makes our method suitable for clinical applications, where the sharing of patient data is restricted.


Subject(s)
Neural Networks, Computer , Prostate/diagnostic imaging , Prostatic Neoplasms/drug therapy , Prostatic Neoplasms/therapy , Tomography, X-Ray Computed , Humans , Male
12.
Med Phys ; 48(5): 2553-2565, 2021 May.
Article in English | MEDLINE | ID: mdl-33651407

ABSTRACT

PURPOSE: Magnetic resonance imaging (MRI)-guided transperineal prostate biopsy has been practiced since the early 2000s. The technique often suffers from targeting error due to deviation of the needle as a result of physical interaction between the needle and inhomogeneous tissues. Existing needle guide devices, such as a grid template, do not allow choosing an alternative insertion path to mitigate the deviation because of their limited degree-of-freedom (DoF). This study evaluates how an angulated needle insertion path can reduce needle deviation and improve needle placement accuracy. METHODS: We extended a robotic needle-guidance device (Smart Template) for in-bore MRI-guided transperineal prostate biopsy. The new Smart Template has a 4-DoF needle-guiding mechanism allowing a translational range of motion of 65 and 58 mm along the vertical and horizontal axis, and a needle rotational motion around the vertical and horizontal axis ± 30 ∘ and a vertical rotational range of - 30 ∘ , + 10 ∘ , respectively. We defined a path planning strategy, which chooses between straight and angulated insertion paths depending on the anatomical structures on the potential insertion path. We performed (a) a set of experiments to evaluate the device positioning accuracy outside the MR-bore, and (b) an in vivo experiment to evaluate the improvement of targeting accuracy combining straight and angulated insertions in animal models (swine, n = 3 ). RESULTS: We analyzed 46 in vivo insertions using either straight or angulated insertions paths. The experiment showed that the proposed strategy of selecting straight or angulated insertions based on the subject's anatomy outperformed the conventional approach of just straight insertions in terms of targeting accuracy (2.4 mm [1.3-3.7] vs 3.9 mm [2.4-5.0] {Median IQR } ); p = 0.041 after the bias correction). CONCLUSION: The in vivo experiment successfully demonstrated that an angulated needle insertion path could improve needle placement accuracy with a path planning strategy that takes account of the subject-specific anatomical structures.


Subject(s)
Prostatic Neoplasms , Robotics , Animals , Humans , Image-Guided Biopsy , Magnetic Resonance Imaging , Male , Needles , Prostate/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Swine
13.
Eur Urol Focus ; 7(6): 1274-1286, 2021 Nov.
Article in English | MEDLINE | ID: mdl-32873515

ABSTRACT

CONTEXT: As an emerging technique, three-dimensional (3D) visualization has become more popular and can facilitate education, training, surgical planning, and intraoperative guidance for prostate cancer surgery. OBJECTIVE: In this review, we aim to present the impact of 3D printing, virtual reality (VR), and augmented reality (AR) techniques for prostate cancer procedures, specifically prostate biopsy and radical prostatectomy (RP). EVIDENCE ACQUISITION: A systematic review was performed by two investigators according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) criteria. EVIDENCE SYNTHESIS: A total of 541 papers were identified in PubMed, Scopus, and Embase. Of these, 53 studies were identified for detailed review and 25 were qualified. Two more studies were identified from the references; thus, 27 studies were finally included in this systematic review. Nine papers reported on the use of 3D reconstructed models, mainly in education/training and intraoperative guidance; nine reported on VR, focusing on simulation training model and intraoperative guidance; and nine reported on AR technique with its best indication for surgical guidance in robotic RP. CONCLUSIONS: Three-dimensional visualization techniques have gradually been introduced and developed in prostate procedures, and demonstrate potential utility not only for education/training, but also for surgical planning and intraoperative guidance. Prospective studies are needed to demonstrate clinical utility and validation of these technologies. PATIENT SUMMARY: Despite low-quality evidence, promising signals were identified to demonstrate that three-dimensional visualization could help facilitate prostate procedures, in terms of education/training, surgical planning, and intraoperative guidance. It is still in a very early stage, and more studies need to be conducted to justify its widespread use.


Subject(s)
Prostatic Neoplasms , Robotic Surgical Procedures , Humans , Imaging, Three-Dimensional/methods , Male , Prostate/diagnostic imaging , Prostate/pathology , Prostate/surgery , Prostatectomy/methods , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Prostatic Neoplasms/surgery , Robotic Surgical Procedures/methods
14.
Acad Radiol ; 28(6): 841-848, 2021 06.
Article in English | MEDLINE | ID: mdl-32863151

ABSTRACT

RATIONALE AND OBJECTIVES: There have been multiple investigations defining and reporting the effectiveness of focal cryoablation as a treatment option for organ-confined prostate cancer. However, the impact of cryo-needle/probe placement accuracy within the tumor and gland has not been extensively studied. We analyzed how variations in the placement of the cryo-needles, specifically errors leading to incomplete ablation, may affect prostate cancer's resulting cryoablation. MATERIALS AND METHODS: We performed a study based on isothermal models using Monte Carlo simulations to analyze the impact of needle placement errors on tumor coverage and the probability of positive ablation margin. We modeled the placement error as a Gaussian noise on the cryo-needle position. The analysis used retrospective MRI data of 15 patients with biopsy-proven, unifocal, and MRI visible prostate cancer to calculate the impact of placement error on the volume of the tumor encompassed by the -40°C and -20°C isotherms using one to four cryo-needles. RESULTS: When the standard deviation of the placement error reached 3 mm, the tumor coverage was still above 97% with the -20°C isotherm, and above 81% with the -40°C isotherm using two cryo-needles or more. The probability of positive margin was significantly lower considering the -20°C isotherm (0.04 for three needles) than using the -40°C isotherm (0.66 for three needles). CONCLUSION: The results indicated that accurate cryo-needle placement is essential for the success of focal cryoablation of prostate cancer. The analysis shows that an admissible targeting error depends on the lethal temperature considered and the number of cryo-needles used.


Subject(s)
Cryosurgery , Prostatic Neoplasms , Humans , Magnetic Resonance Imaging , Male , Needles , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery , Retrospective Studies
15.
Med Phys ; 47(6): 2337-2349, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32141080

ABSTRACT

PURPOSE: Magnetic resonance imaging (MRI)-guided percutaneous cryotherapy of abdominal lesions, an established procedure, uses MRI to guide and monitor the cryoablation of lesions. Methods to precisely guide cryotherapy probes with a minimum amount of trial-and-error are yet to be established. To aid physicians in attaining precise probe alignment without trial-and-error, a body-mounted motorized cryotherapy-probe alignment device (BMCPAD) with motion compensation was clinically tested in this study. The study also compared the contribution of body motion and organ motion compensation to the guidance accuracy of a body-mounted probe alignment device. METHODS: The accuracy of guidance using the BMCPAD was prospectively measured during MRI-guided percutaneous cryotherapies before insertion of the probes. Clinical parameters including patient age, types of anesthesia, depths of the target, and organ sites of target were collected. By using MR images of the target organs and fiducial markers embedded in the BMCPAD, we retrospectively simulated the guidance accuracy with body motion compensation, organ motion compensation, and no compensation. The collected data were analyzed to test the impact of motion compensation on the guidance accuracy. RESULTS: Thirty-seven physical guidance of probes were prospectively recorded for sixteen completed cases. The accuracy of physical guidance using the BMCPAD was 13.4 ± 11.1 mm. The simulated accuracy of guidance with body motion compensation, organ motion compensation, and no compensation was 2.4 ± 2.9 mm, 2.2 ± 1.6 mm, and 3.5 ± 2.9 mm, respectively. Data analysis revealed that the body motion compensation and organ motion compensation individually impacted the improvement in the accuracy of simulated guidance. Moreover, the difference in the accuracy of guidance either by body motion compensation or organ motion compensation was not statistically significant. The major clinical parameters impacting the accuracy of guidance were the body and organ motions. Patient age, types of anesthesia, depths of the target, and organ sites of target did not influence the accuracy of guidance using BMCPAD. The magnitude of body surface movement and organ movement exhibited mutual statistical correlation. CONCLUSIONS: The BMCPAD demonstrated guidance accuracy comparable to that of previously reported devices for CT-guided procedures. The analysis using simulated motion compensation revealed that body motion compensation and organ motion compensation individually impact the improvement in the accuracy of device-guided cryotherapy probe alignment. Considering the correlation between body and organ movements, we also determined that body motion compensation using the ring fiducial markers in the BMCPAD can be solely used to address both body and organ motions in MRI-guided cryotherapy.


Subject(s)
Fiducial Markers , Magnetic Resonance Imaging , Cryotherapy , Humans , Motion , Retrospective Studies
16.
Invest Radiol ; 55(5): 310-317, 2020 05.
Article in English | MEDLINE | ID: mdl-31977600

ABSTRACT

PURPOSE: The aim of this study was to develop a method to delineate the lethally frozen-tissue region (temperature less than -40°C) arising from interventional cryoablation procedures using a short tau inversion-recovery ultrashort echo-time (STIR-UTE) magnetic resonance (MR) imaging sequence. This method could serve as an intraprocedural validation of the completion of tumor ablation, reducing the number of local recurrences after cryoablation procedures. MATERIALS AND METHODS: The method relies on the short T1 and T2* relaxation times of frozen soft tissue. Pointwise Encoding Time with Radial Acquisition, a 3-dimensional UTE sequence with TE = 70 microseconds, was optimized with STIR to null tissues with a T1 of approximately 271 milliseconds, the threshold T1. Because the T1 relaxation time of frozen tissue in the temperature range of -40°C < temperature < -8°C is shorter than the threshold T1 at the 3-tesla magnetic field, tissues in this range should appear hyperintense. The sequence was evaluated in ex vivo frozen tissue, where image intensity and actual tissue temperatures, measured by thermocouples, were correlated. Thereafter, the sequence was evaluated clinically in 12 MR-guided prostate cancer cryoablations, where MR-compatible cryoprobes were used to destroy cancerous tissue and preserve surrounding normal tissue. RESULTS: The ex vivo experiment using a bovine muscle demonstrated that STIR-UTE images showed regions approximately between -40°C and -8°C as hyperintense, with tissues at lower and higher temperatures appearing dark, making it possible to identify the region likely to be above the lethal temperature inside the frozen tissue. In the clinical cases, the STIR-UTE images showed a dark volume centered on the cryoprobe shaft, Vinner, where the temperature is likely below -40°C, surrounded by a doughnut-shaped hyperintense volume, where the temperature is likely between -40°C and -8°C. The hyperintense region was itself surrounded by a dark volume, where the temperature is likely above -8°C, permitting calculation of Vouter. The STIR-UTE frozen-tissue volumes, Vinner and Vouter, appeared significantly smaller than signal voids on turbo spin echo images (P < 1.0 × 10), which are currently used to quantify the frozen-tissue volume ("the iceball"). The ratios of the Vinner and Vouter volumes to the iceball were 0.92 ± 0.08 and 0.29 ± 0.07, respectively. In a single postablation follow-up case, a strong correlation was seen between Vinner and the necrotic volume. CONCLUSIONS: Short tau inversion-recovery ultrashort echo-time MR imaging successfully delineated the area approximately between -40°C and -8°C isotherms in the frozen tissue, demonstrating its potential to monitor the lethal ablation volume during MR-guided cryoablation.


Subject(s)
Cryosurgery/methods , Magnetic Resonance Imaging/methods , Monitoring, Intraoperative/methods , Prostatic Neoplasms/surgery , Animals , Cattle , Humans , Male , Prostatic Neoplasms/diagnosis , Temperature
17.
IEEE Trans Biomed Eng ; 67(2): 565-576, 2020 02.
Article in English | MEDLINE | ID: mdl-31135342

ABSTRACT

OBJECTIVE: Accurate biopsy sampling of the suspected lesions is critical for the diagnosis and clinical management of prostate cancer. Transperineal in-bore MRI-guided prostate biopsy (tpMRgBx) is a targeted biopsy technique that was shown to be safe, efficient, and accurate. Our goal was to develop an open source software platform to support evaluation, refinement, and translation of this biopsy approach. METHODS: We developed SliceTracker, a 3D Slicer extension to support tpMRgBx. We followed modular design of the implementation to enable customization of the interface and interchange of image segmentation and registration components to assess their effect on the processing time, precision, and accuracy of the biopsy needle placement. The platform and supporting documentation were developed to enable the use of software by an operator with minimal technical training to facilitate translation. Retrospective evaluation studied registration accuracy, effect of the prostate segmentation approach, and re-identification time of biopsy targets. Prospective evaluation focused on the total procedure time and biopsy targeting error (BTE). RESULTS: Evaluation utilized data from 73 retrospective and ten prospective tpMRgBx cases. Mean landmark registration error for retrospective evaluation was 1.88 ± 2.63 mm, and was not sensitive to the approach used for prostate gland segmentation. Prospectively, we observed target re-identification time of 4.60 ± 2.40 min and BTE of 2.40 ± 0.98 mm. CONCLUSION: SliceTracker is modular and extensible open source platform for supporting image processing aspects of the tpMRgBx procedure. It has been successfully utilized to support clinical research procedures at our site.


Subject(s)
Image-Guided Biopsy/methods , Magnetic Resonance Imaging/methods , Prostate/diagnostic imaging , Prostatic Neoplasms , Software , Humans , Image Interpretation, Computer-Assisted , Male , Perineum/diagnostic imaging , Perineum/surgery , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology
18.
Med Phys ; 47(3): 850-858, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31829440

ABSTRACT

PURPOSE: Image guidance is crucial for percutaneous tumor ablations, enabling accurate needle-like applicator placement into target tumors while avoiding tissues that are sensitive to injury and/or correcting needle deflection. Although ultrasound (US) is widely used for image guidance, magnetic resonance (MR) is preferable due to its superior soft tissue contrast. The objective of this study was to develop and evaluate an MR and US multi-modal image-guided navigation system with a needle manipulator to enable US-guided applicator placement during MR imaging (MRI)-guided percutaneous tumor ablation. METHODS: The MRI-compatible needle manipulator with US probe was installed adjacent to a 3 Tesla MRI scanner patient table. Coordinate systems for the MR image, patient table, manipulator, and US probe were all registered using an optical tracking sensor. The patient was initially scanned in the MRI scanner bore for planning and then moved outside the bore for treatment. Needle insertion was guided by real-time US imaging fused with the reformatted static MR image to enhance soft tissue contrast. Feasibility, targeting accuracy, and MR compatibility of the system were evaluated using a bovine liver and agar phantoms. RESULTS: Targeting error for 50 needle insertions was 1.6 ± 0.6 mm (mean ± standard deviation). The experiment confirmed that fused MR and US images provided real-time needle localization against static MR images with soft tissue contrast. CONCLUSIONS: The proposed MR and US multi-modal image-guided navigation system using a needle manipulator enabled accurate needle insertion by taking advantage of static MR and real-time US images simultaneously. Real-time visualization helped determine needle depth, tissue monitoring surrounding the needle path, target organ shifts, and needle deviation from the path.


Subject(s)
Ablation Techniques/instrumentation , Image-Guided Biopsy/instrumentation , Magnetic Resonance Imaging , Needles , Animals , Cattle , Feasibility Studies , Image Processing, Computer-Assisted , Liver/diagnostic imaging , Liver/surgery , Phantoms, Imaging , Ultrasonography , Workflow
19.
J Med Robot Res ; 4(2)2019 Jun.
Article in English | MEDLINE | ID: mdl-31485544

ABSTRACT

This paper presents the development, preclinical evaluation, and preliminary clinical study of a robotic system for targeted transperineal prostate biopsy under direct interventional magnetic resonance imaging (MRI) guidance. The clinically integrated robotic system is developed based on a modular design approach, comprised of surgical navigation application, robot control software, MRI robot controller hardware, and robotic needle placement manipulator. The system provides enabling technologies for MRI-guided procedures. It can be easily transported and setup for supporting the clinical workflow of interventional procedures, and the system is readily extensible and reconfigurable to other clinical applications. Preclinical evaluation of the system is performed with phantom studies in a 3 Tesla MRI scanner, rehearsing the proposed clinical workflow, and demonstrating an in-plane targeting error of 1.5mm. The robotic system has been approved by the institutional review board (IRB) for clinical trials. A preliminary clinical study is conducted with the patient consent, demonstrating the targeting errors at two biopsy target sites to be 4.0mm and 3.7mm, which is sufficient to target a clinically significant tumor foci. First-in-human trials to evaluate the system's effectiveness and accuracy for MR image-guide prostate biopsy are underway.

20.
IEEE ASME Trans Mechatron ; 24(2): 883-888, 2019 Apr.
Article in English | MEDLINE | ID: mdl-32774079

ABSTRACT

Foldable origami structures have been implemented into robotics as a way of compacting joints and circuitry into smaller structures. This technique is especially useful in minimally invasive surgical instruments, where the goal is to create slimline devices that can be inserted through small incisions. Origami also has the potential to cut costs by reducing the amount of material required for assembly. Origami devices are especially suitable for MRI-guided procedures, where instruments must be nonmagnetic because origami is more suitable for flexible, non-metallic materials. MR conditional surgical instruments enable intraoperative MRI procedures that provide superior imaging capabilities to physicians to allow for safer procedures. This work presents an MR conditional joint developed using origami techniques that reduces costs by eliminating assembly of various components and has potential applications in endoscopy. The joint is a compliant rolling-contact element that employs curved-folding origami techniques. A chain of these joints can be constructed from a single sheet of material, eliminating assembly of numerous materials to produce a final product, which is specifically advantageous for constructing low-cost, disposable surgical devices. The prototype contains a degree of bending of ±9 degrees per joint, a response time of less than 4 seconds and an actuation force of 0.5 N using a 1.25 A current. The MRI results showed a minimal artifact of less than 1 mm measured from the boundary of the joint chain and a SNR reduction of less than 10%.

SELECTION OF CITATIONS
SEARCH DETAIL
...