Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
J Clin Med ; 13(12)2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38930151

ABSTRACT

Background: Raghib syndrome is a rare malformation complex consisting of the drainage of the left superior vena cava (LSVC) into the left atrium, ostial atresia of the coronary sinus and an atrial septal defect (ASD). Case Report: This report aims to present the case of a child newly diagnosed with Raghib syndrome, complicated by pulmonary arterial hypertension, and to review previously published cases with the same diagnosis. A six-year-old female patient presented with signs and symptoms of heart failure (Ross III), reduced exercise tolerance and severe delay in stature and ponderal development. The imagistic work-up included echocardiography, followed by computer tomography (CT) and magnetic resonance imaging (MRI), through which a diagnosis of Raghib syndrome was established, complicated by pulmonary hypertension. As in other cases presented in the literature, MRI allowed for an accurate diagnosis, detecting the absent coronary sinus. The decision regarding the surgical closure of the ASD was made, with the patient having a favorable clinical evolution but with the persistence of elevated pulmonary artery pressure, for which Sildenafil therapy was instituted. Conclusions: The malformation complex consisting of an atrial septal defect, ostium atresia of the coronary sinus, uncovered coronary sinus, and persistent left superior vena cava, as identified through multiple imagistic investigations, was suggestive of the rare diagnosis of Raghib syndrome in this case. Among the limited number of cases of Raghib syndrome available in the literature, the present case is distinguished by the severity of the pulmonary artery hypertension at a very young age and in the absence of other concurrent cardiac malformations.

2.
Biomedicines ; 12(6)2024 May 21.
Article in English | MEDLINE | ID: mdl-38927343

ABSTRACT

BACKGROUND AND OBJECTIVES: The purpose of this study was to investigate whether early surfactant administration affects the status of ductus arteriosus (DA) in preterm infants ≤ 32 weeks of gestational age (GA) within 24 h of birth. MATERIALS AND METHODS: It is a prospective study conducted from 1 March 2022 to 31 December 2023 in a tertiary academic center. In-born infants ≤ 32 weeks of gestation (n = 88) were enrolled. The study group was further divided into surfactant (n = 44) and non-surfactant (n = 44) subgroups. RESULTS: A total of 76% of the preterm infants who received surfactant therapy (RRR = 0.839) recorded an increase in Kindler score at 24 h of life (1 - RR = 1 - 0.24 = 76%). Surfactant administration was significantly associated with decreased pre-ductal diastolic pressure (29.9 mmHg vs. 34.8 mmHg, p = 0.0231), post-ductal diastolic pressure (28.7 mmHg vs. 32.2 mmHg, p = 0.0178), pre-ductal MAP (41.6 mmHg vs. 46.5 mmHg, p = 0.0210), and post-ductal MAP (41.0 mmHg vs. 45.3 mmHg, p = 0.0336). There were no significant changes in ductus arteriosus parameters at 24 h of life. CONCLUSIONS: Early surfactant administration does not affect the status of ductus arteriosus in preterm infants ≤ 32 weeks of gestational age at 24 h of life.

3.
Plants (Basel) ; 13(7)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38611526

ABSTRACT

Hyssop (Hyssopus officinalis L.) and oregano (Origanum vulgare L.), traditionally used for their antimicrobial properties, can be considered viable candidates for nanotechnology applications, in particular for the phytosynthesis of metal nanoparticles. The present work aims to evaluate the potential application of hyssop and oregano for the phytosynthesis of silver nanoparticles, as well as to evaluate the biological activities of their extracts and obtained nanoparticles (antioxidant potential, as well as cell viability, inflammation level and cytotoxicity in human fibroblasts HFIB-G cell line studies). In order to obtain natural extracts, two extraction methods were applied (classical temperature extraction and microwave-assisted extraction), with the extraction method having a major influence on their composition, as demonstrated by both the total phenolic compounds (significantly higher for the microwave-assisted extraction; the oregano extracts had consistently higher TPC values, compared with the hyssop extracts) and in terms of individual components identified via HPLC. The obtained nanoparticles ware characterized via X-ray diffraction (XRD) and transmission electron microscopy (TEM), with the lowest dimension nanoparticles being recorded for the nanoparticles obtained using the oregano microwave extract (crystallite size 2.94 nm through XRD, average diameter 10 nm via TEM). The extract composition and particle size also influenced the antioxidant properties (over 60% DPPH inhibition being recorded for the NPs obtained using the oregano microwave extract). Cell viability was not affected at the lowest tested concentrations, which can be correlated with the nitric oxide level. Cell membrane integrity was not affected after exposure to classic temperature hyssop extract-NPs, while the other samples led to a significant LDH increase.

4.
Front Pediatr ; 12: 1302383, 2024.
Article in English | MEDLINE | ID: mdl-38550630

ABSTRACT

Introduction: Assessment of myocardial function through speckle tracking echocardiography (STE) can bring benefits to conventional echocardiography in premature newborns, a particular vulnerable group in terms of adaptation to extra-uterine life. Furthermore, it represents a non-invasive imagistic method which can guide therapeutic approach in the hemodynamically unstable newborn. This study aims to highlight the particularities of myocardial function in late premature newborns, by conducting a comparison with a group of healthy neonates, by using STE. Methods: Conducted over a timespan of two years, this prospective study enrolled 64 term neonates and 21 premature newborns, with gestational ages ranging between 28 and 36 weeks, who prior to discharge underwent a cardiac ultrasound, involving two-dimensional image acquisitions of the apical four-chamber view of both ventricles. Afterwards, the images were offline analyzed, by using the autostrain function. Results: After segmental strain analysis, no significant discrepancies between the two groups in terms of interventricular values were found. However, left ventricle and right ventricle strain measurements differed significantly (p < 0.01), for each of the analyzed segments (basal, medial or apical). Moreover, a linear increase in interventricular (IV) basal strain with corrected gestational age progression was noted (p = 0.04). Peak global longitudinal strain (pGLS) and EF were similar between the two study groups. Premature newborns presented significantly more negative mean values of right ventricular free wall longitudinal strain (RVFWSL), (-24.19 ± 4.95 vs. -18.05 ± 5.88, p < 0.01) and of right ventricle global four chamber longitudinal strain (RV4CSL), (-19.71 ± 3.62 vs. -15.46 ± 5.59, p < 0.01), when compared to term neonates. Conclusions: The 2D STE is a reliable method for cardiac assessment of late preterm newborns. The evaluation of two-dimensional global longitudinal LV and RV strains might represent a useful tool in clinical practice. A better response of the right ventricle to the longitudinal deformation within premature neonates was noted. Thus, this study facilitates the identification of accurate reference values for this particular population segment, which will enable the evaluation of ventricular function in premature newborns with concurring disorders. Future longitudinal studies, assessing the fetal heart, could provide more insight into the development of myocardial function.

5.
Med Ultrason ; 25(2): 168-174, 2023 Jun 26.
Article in English | MEDLINE | ID: mdl-37369048

ABSTRACT

AIMS: Measurement of myocardial strain using 2D speckle-tracking echocardiography can successfully quantify ventricular function, being considered superior to conventional echocardiography. This study aimed to establish reference intervals, interobserver agreements and reliability of two fetal echocardiographic parameters which reflect left ventricular myocardial function, left ventricular apical 4 chamber endo peak strain (AP4pLS) and ejection fraction (EF). MATERIAL AND METHODS: We conducted a prospective study on 103 healthy fetuses. In each case, cardiac ultrasound images obtained were stored and afterwards were subject to offline 2D speckle-tracking echocardiographic analyses. In 15 randomly chosen subjects a second examiner also carried out an offline analysis of the 4-chamber view and the archived images, in order to assess inter-observer reproducibility and agreement level. Our study group was sub-divided into four different gestational age groups. RESULTS: Reference ranges were established for the two measured parameters, AP4pLS and EF, which did not differ significantly between four different gestational age groups (p=0.98 and p=0.64) and neither correlated with gestational age progression (p=0.37 and p=0.08). An excellent level of agreement between the two examiners was found for the echocardiographic measurements, expressed through an intra-class correlation coefficient (ICC) value of 0.85 (0.62-0.94 for 95%CI) for AP4pLS and 0.78 (0.47- 0.92 for 95% CI) for EF. CONCLUSIONS: Speckle tracking AP4pLS and EF parameters are useful for assessment of ventricular myocardial function in healthy fetuses and can be reliably reproduced by two different skilled examiners. Further studies conducted on larger populations are required to standardize reference values of fetal speckle-tracking measurements.


Subject(s)
Echocardiography , Ventricular Function, Left , Humans , Reproducibility of Results , Prospective Studies , Observer Variation , Echocardiography/methods , Heart Ventricles/diagnostic imaging , Fetal Heart/diagnostic imaging
6.
J Crit Care Med (Targu Mures) ; 9(1): 6-11, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36890976

ABSTRACT

Congenital heart malformations are cardiac and/or vascular structural abnormalities that appear before birth, the majority of which can be detected prenatally. The latest data from the literature were reviewed, with reference to the degree of prenatal diagnosis regarding congenital heart malformations, as well as its impact on the preoperative evolution and implicitly on mortality. Studies with a significant number of enrolled patients were included in the research. Prenatal congenital heart malformations detection rates were different, depending on the period in which the study took place, the level of the medical center, as well as on the size of enrolled groups. Prenatal diagnosis in critical malformations such as hypoplastic left heart syndrome, transposition of great arteries and totally aberrant pulmonary venous drainage has proven its usefulness, allowing an early surgical intervention, thus ensuring improved neurological development, increasing the survival rate and decreasing the rate of subsequent complications. Sharing the experience and results obtained by each individual therapeutic center will definitely lead to drawing clear conclusions regarding the clinical contribution of congenital heart malformations prenatal detection.

7.
Article in English | MEDLINE | ID: mdl-35886472

ABSTRACT

Data regarding reference intervals for strain parameters derived from 2D speckle-tracking echocardiography in full-term newborns are limited and still under development. Our objectives were to establish the level of reproducibility and reference intervals in assessing myocardial function using 2D speckle-tracking echocardiography for longitudinal and regional strain measurements. A total of 127 full-term newborns were examined to be included in the study, of which 103 were analyzed. We used two-dimensional acquisitions from apical four-chamber view of both ventricles and analyzed the autostrain function offline. We obtained interobserver agreement between the two observers ranging from good to excellent for all speckle-tracking parameters except for the strain of the medial portion of the left ventricle (LV) lateral wall and the strain measured on the basal portion of the inter-ventricular septum, which reflected a fair interobserver reproducibility (ICC = 0.52, 95% IC: 0.22-0.72 and ICC = 0.43, 95% IC: 0.12-0.67, respectively). The reference values obtained for the LV peak longitudinal strain were between -24.65 and -14.62, those for the right ventricle (RV) free wall were from -28.69 to -10.68, and those for the RV global four-chamber were from -22.30 to -11.37. In conclusion, two-dimensional peak longitudinal LV and RV strains are reproducible with good to excellent agreement and may represent a possible alternative for the cardiac assessment of healthy newborns in the clinical practice.


Subject(s)
Echocardiography , Heart Ventricles , Echocardiography/methods , Heart Ventricles/diagnostic imaging , Humans , Infant, Newborn , Observer Variation , Reference Values , Reproducibility of Results
8.
Sci Rep ; 12(1): 3613, 2022 03 07.
Article in English | MEDLINE | ID: mdl-35256685

ABSTRACT

Improving sleep quality in patients with obstructive sleep apnea (OSA) by positive airway pressure therapy is associated with a decrease of blood pressure (BP). It remains elusive, whether treatment of sleep disturbances due to restless legs syndrome with symptomatic periodic limb movements in sleep (PLMS) affects BP as well. The present study provides first data on this issue. Retrospective study on patients undergoing polysomnography in a German University Hospital. Inclusion criteria were first diagnosis of restless legs syndrome with PLMS (PLM index ≥ 15/h and PLM arousal index ≥ 5/h) with subsequent initiation of levodopa/benserazide or dopamine agonists. Exclusion criterion was an initiation or change of preexisting positive airway pressure therapy between baseline and follow-up. BP and Epworth sleepiness scale were assessed at two consecutive polysomnographies. After screening of 953 PLMS data sets, 114 patients (mean age 62.1 ± 12.1 years) were included. 100 patients (87.7%) were started on levodopa/benserazide, 14 patients (12.2%) on dopamine agonists. Treatment was associated with significant reductions of PLM index (81.2 ± 65.0 vs. 39.8 ± 51.2, p < 0.001) and ESS (6 [interquartile range, IQR, 3-10.5] vs. 5 [IQR 3-10], p = 0.013). Systolic BP decreased from 132.9 ± 17.1 to 128.0 ± 15.8 mmHg (p = 0.006), whereas there was no significant change of diastolic BP (76.7 ± 10.9 vs. 75.1 ± 9.2 mmHg, p = 0.15) and heart rate (71.5 ± 11.9 vs. 71.3 ± 12.7, p = 0.84). The number of antihypertensive drugs remained unchanged with a median of 2 (IQR 1-3, p = 0.27). Dopaminergic treatment of PLMS is associated with an improvement of sleep quality and a decrease of systolic BP comparable to treatment OSA.


Subject(s)
Restless Legs Syndrome , Sleep Apnea Syndromes , Sleep Apnea, Obstructive , Aged , Benserazide/therapeutic use , Blood Pressure , Dopamine Agonists , Humans , Levodopa/therapeutic use , Middle Aged , Retrospective Studies , Sleep , Sleep Apnea Syndromes/complications , Sleep Apnea, Obstructive/complications , Sleep Apnea, Obstructive/drug therapy
9.
J Clin Med ; 11(3)2022 Feb 02.
Article in English | MEDLINE | ID: mdl-35160256

ABSTRACT

Sustained fetal tachycardias are rare but represent a high risk of mortality and morbidity. Consensus has yet to be found regarding their optimal management. The aim of this narrative review is to summarize the data available in the current literature regarding the efficacy and safety of medications used in the management of intrauterine tachyarrhythmias and to provide possible treatment protocols. In this review, we would like to emphasize the importance of a thorough evaluation of both the fetus and the mother, prior to transplacental antiarrhythmic drug initiation. Factors such as the hemodynamic status of the fetus, possible mechanisms of fetal arrhythmia, and concomitant maternal conditions are of primordial importance. As a possible treatment protocol, we would like to recommend the following: due to the risk of sustained supraventricular tachycardia (SVT), fetuses with frequent premature atrial beats should be evaluated more frequently by echocardiography. A careful hemodynamic evaluation of a fetus with tachycardia is primordial in forestalling the appearance of hydrops. In the case of atrial flutter (AFL), sotalol therapy could represent a first choice, whereas when dealing with SVT patients, flecainide should be considered, especially for hydropic patients. These data require consolidation through larger scale, non-randomized studies and should be handled with caution.

10.
J Pers Med ; 12(1)2022 Jan 06.
Article in English | MEDLINE | ID: mdl-35055372

ABSTRACT

Our aim was to compare the global longitudinal and regional biventricular strain between infants with severe and critical pulmonary stenosis (PS), and controls; to compare pre- and post-procedural strain values in infants with severe and critical PS; and to assess the correlations between echocardiographic strain and conventional parameters. We conducted a retrospective single-center study. The comparisons of echocardiographic variables were performed using separate linear mixed models. The overall mean right ventricle (RV) regional strains measured before intervention in PS patients was significantly different when compared to the control group (p = 0.0324). We found a significant change in the left ventricle, RV, and inter-ventricular septum strain (IVS) values from basal to apical location (p < 0.05). IVS strain values showed a higher decrease in mean strain values from basal to apical in PS patients. There was no significant difference in means of baseline and post-interventional strain values in PS patients (p > 0.05). Following the strain analysis in patients with PS, we obtained statistically significant changes in the RV global-4-chamber longitudinal strain (RV4C). The RV4C, which quantifies the longitudinal strain to the entire RV, can be used in current clinical practice for the evaluation of RV function in infants with severe and critical PS. The longitudinal and segmental strain capture the pathological changes in the IVS, modifications that cannot be highlighted through a classical echocardiographic evaluation.

11.
Article in English | MEDLINE | ID: mdl-36612992

ABSTRACT

The transposition of great arteries (TGA) is one of the most frequent and severe congenital heart diseases. After newborn stabilization and while pending surgical correction, echocardiographic monitoring with a careful evaluation of left ventricle (LV) performance is warranted. In this study, our objectives were (i) to compare myocardial function, assessed via speckle-tracking echocardiography, between neonates with TGA and neonates without TGA and (ii) to identify a strain parameter with a good discriminatory ability for TGA. We conducted a retrospective, single-center study. A total of 90 neonates were examined, of whom 66 were included (16 comprised the TGA group and 50 comprised the control group). The results of a bivariate analysis showed that classic echocardiography parameters displayed no significant differences between the two studied groups (p = 0.785 for EF, p = 0.286 for MAPSE and p = 0.315 for TAPSE). We found a statistically significant difference between the two groups for the mean values of the LVpGLS parameter (adjusted p = 0.0047), with impaired LV myocardium function being observed in the TGA group after adjusting for other covariates. Regarding segmental strain, the mean medial and apical inter-ventricular septum strain values were found to be significantly lower in the neonates with TGA than in the controls (95% CI for difference in means: [-6.45, -0.65], [-8.56, -1.97]). The results of an ROC analysis showed that LVpGLS had a significant ability to differentiate between neonates with TGA and controls (AUC = 0.712, 95% CI: [0.52, 0.903], p = 0.011). In conclusion, LVpGLS is a parameter with a significant discriminatory ability for LV dysfunction, and it is useful in the evaluation of ventricular myocardial function in newborns with TGA.


Subject(s)
Heart Ventricles , Transposition of Great Vessels , Humans , Infant, Newborn , Heart Ventricles/diagnostic imaging , Retrospective Studies , Transposition of Great Vessels/diagnostic imaging , Transposition of Great Vessels/surgery , Echocardiography/methods , Ventricular Function, Left
12.
J Clin Med ; 10(19)2021 Oct 02.
Article in English | MEDLINE | ID: mdl-34640597

ABSTRACT

Our objectives are to compare speckle-tracking peak global longitudinal (pGLS) and regional strain values in neonates with coarctation of aorta (CoA) and control groups. Echocardiographic parameters measured by speckle-tracking were studied in a retrospective single-center study. A comparison of pGLS and segmental deformation between neonates with CoA and control group was performed using a three-way mixed ANOVA model. There was a significant difference in the means of segmental strain values between CoA and control group at the apical (p = 0.018) and basal segments (p = 0.031) of the interventricular septum and at the apical segment (p = 0.026) of the left ventricle (LV). After correcting for multiple comparisons, the results had a tendency toward statistical significance (adjusted-p < 0.10). There was significant difference in the mean values of pGLS [F(1, 39) = 7.61, p = 0.009, adjusted p = 0.018] between the studied groups. The results of ROC analysis showed that a cut-off value of -16.60% for pGLS provided an estimated sensitivity of 92.31% (95% CI: [63.97, 99.81]) and 71.43% specificity (95% CI: [51.33, 86.78]) for the diagnosis of CoA in neonates (AUC = 0.794, 95% CI: [0.66, 0.93]). pGLS can be regarded as a feasible and reproducible parameter reflecting LV dysfunction in newborns with CoA when compared to newborns with a false-positive diagnosis.

13.
J Med Case Rep ; 14(1): 242, 2020 Dec 11.
Article in English | MEDLINE | ID: mdl-33308254

ABSTRACT

BACKGROUND: Developing therapeutic strategies for a SARS-CoV-2 infection is challenging, but first the correct diagnosis has to be made. Unspecific upper and lower respiratory tract symptoms can be misleading; hence, a nasopharyngeal swab test with a real-time reverse-transcription-polymerase chain reaction is of great importance. However, early viral clearing jeopardizes a sound diagnosis of COVID-19. CASE PRESENTATION: We report on two Caucasian patients who had negative pharyngeal swab tests at the onset of SARS-CoV-2 pneumonia. In one patient, the virus was not even detectable in bronchoalveolar lavage despite typical radiomorphologic changes. CONCLUSIONS: Negative PCR findings in both the pharynx and bronchoalveolar lavage do not exclude COVID-19 pneumonia. Computed tomography is a crucial diagnostic prerequisite in this context.


Subject(s)
COVID-19 Nucleic Acid Testing , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , Aged, 80 and over , False Positive Reactions , Female , Humans , Male , Middle Aged , Reverse Transcriptase Polymerase Chain Reaction , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...