Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Neurology ; 100(4): e408-e421, 2023 Jan 24.
Article in English | MEDLINE | ID: mdl-36257718

ABSTRACT

BACKGROUND AND OBJECTIVES: Declines in stroke admission, IV thrombolysis (IVT), and mechanical thrombectomy volumes were reported during the first wave of the COVID-19 pandemic. There is a paucity of data on the longer-term effect of the pandemic on stroke volumes over the course of a year and through the second wave of the pandemic. We sought to measure the effect of the COVID-19 pandemic on the volumes of stroke admissions, intracranial hemorrhage (ICH), IVT, and mechanical thrombectomy over a 1-year period at the onset of the pandemic (March 1, 2020, to February 28, 2021) compared with the immediately preceding year (March 1, 2019, to February 29, 2020). METHODS: We conducted a longitudinal retrospective study across 6 continents, 56 countries, and 275 stroke centers. We collected volume data for COVID-19 admissions and 4 stroke metrics: ischemic stroke admissions, ICH admissions, IVT treatments, and mechanical thrombectomy procedures. Diagnoses were identified by their ICD-10 codes or classifications in stroke databases. RESULTS: There were 148,895 stroke admissions in the 1 year immediately before compared with 138,453 admissions during the 1-year pandemic, representing a 7% decline (95% CI [95% CI 7.1-6.9]; p < 0.0001). ICH volumes declined from 29,585 to 28,156 (4.8% [5.1-4.6]; p < 0.0001) and IVT volume from 24,584 to 23,077 (6.1% [6.4-5.8]; p < 0.0001). Larger declines were observed at high-volume compared with low-volume centers (all p < 0.0001). There was no significant change in mechanical thrombectomy volumes (0.7% [0.6-0.9]; p = 0.49). Stroke was diagnosed in 1.3% [1.31-1.38] of 406,792 COVID-19 hospitalizations. SARS-CoV-2 infection was present in 2.9% ([2.82-2.97], 5,656/195,539) of all stroke hospitalizations. DISCUSSION: There was a global decline and shift to lower-volume centers of stroke admission volumes, ICH volumes, and IVT volumes during the 1st year of the COVID-19 pandemic compared with the prior year. Mechanical thrombectomy volumes were preserved. These results suggest preservation in the stroke care of higher severity of disease through the first pandemic year. TRIAL REGISTRATION INFORMATION: This study is registered under NCT04934020.


Subject(s)
Brain Ischemia , COVID-19 , Stroke , Humans , Brain Ischemia/therapy , COVID-19/epidemiology , COVID-19/therapy , Follow-Up Studies , Intracranial Hemorrhages , Pandemics , Retrospective Studies , SARS-CoV-2 , Stroke/epidemiology , Stroke/therapy , Stroke/diagnosis , Stroke Volume , Thrombectomy , Thrombolytic Therapy/methods , Treatment Outcome
2.
Front Surg ; 6: 16, 2019.
Article in English | MEDLINE | ID: mdl-31024925

ABSTRACT

Purpose: Pre-operative botulinum toxin A (BTA) injection of the lateral obliques aims to facilitate the closure of large ventral hernia defects and decrease the risk of repair breakdown during the critical healing phase. The exact duration of post-operative BTA effect and top-up timing in cases at high risk of recurrence remains uncertain. This study was designed to assess the value of electromyography (EMG) in determining the appropriate time for BTA top-up. Methods: 56 patients underwent ventral hernia repair with pre-operative BTA infiltration of the lateral obliques. Eleven patients at high risk of recurrence considered suitable for BTA top-up were assessed post-operatively with both functional computed tomography (CT) and EMG. CT assessed segmental contractility of each muscle layer. Single-point EMG assessed the activity of individual muscle layers bilaterally in the anterior axillary line. Results: CT showed (i) variable contractility of anterior and posterior muscle segments prior to BTA injection; (ii) absent or incomplete muscle paralysis in over half of all segments; (iii) increased BTA effect on progress scans; and (iv) non-uniform pattern of change in BTA effect between the anterior and posterior muscle. EMG demonstrated modest voluntary activity in most muscle layers. Compared to standard of reference (CT), EMG showed moderate sensitivity (0.62), poor specificity (0.48), poor accuracy (0.57), and incorrect grading in 71% of true positive results. Conclusions: As BTA effect wanes, single-point EMG cannot reliably determine functional muscle status. A novel finding is that BTA-induced paralysis of the abdominal muscles may be remarkably non-uniform in degree, distribution and duration.

3.
Phlebology ; 34(4): 266-271, 2019 May.
Article in English | MEDLINE | ID: mdl-30208755

ABSTRACT

BACKGROUND: Recurrence rates and patterns after endovenous radiofrequency ablation (ERFA) are poorly documented. OBJECTIVE: To assess the incidence and anatomical recurrence patterns of saphenous vein reflux after ERFA. METHOD: Two hundred patients previously treated with ERFA were recalled for clinical assessment and venous-duplex ultrasound at three years post-treatment. RESULTS: A total of 106 patients (68F, 38M) with a mean age of 49.4 years (SD +11.5y) were assessed. Mean follow-up was 42.1 months (SD + 20.1m). Further varicose veins were identified in 31 patients (29.2%). Recanalization/recurrence/failure was diagnosed in 16 patients (15.1%), including 18 trunks (8.7%), 13 great saphenous vein (6.3%) and 5 small saphenous vein (2.4%). Twenty-seven patients (25%) developed neo-incompetence in 31 trunks and 12 non-saphenous veins. All patients with truncal recanalization had a body mass index > 29 (range 29-42). CONCLUSION: Disease progression was twice as high as the recanalization rate at three years post-treatment using ERFA in this study. Raised body mass index may be a contributing factor; however, further longitudinal studies are required. Patient self-selection bias may have also influenced our results.


Subject(s)
Radiofrequency Ablation , Saphenous Vein/diagnostic imaging , Ultrasonography, Doppler, Duplex , Varicose Veins , Venous Insufficiency , Adult , Aged , Female , Follow-Up Studies , Humans , Male , Middle Aged , Recurrence , Retrospective Studies , Varicose Veins/diagnostic imaging , Varicose Veins/therapy , Venous Insufficiency/diagnostic imaging , Venous Insufficiency/therapy
4.
J Appl Physiol (1985) ; 125(2): 393-400, 2018 08 01.
Article in English | MEDLINE | ID: mdl-29698106

ABSTRACT

Pharyngeal and respiratory sensation is impaired in obstructive sleep apnea (OSA). Opioids may further diminish respiratory sensation. Thus protective pharyngeal neuromuscular and arousal responses to airway occlusion that rely on respiratory sensation could be impaired with opioids to worsen OSA severity. However, little is known about the effects of opioids on upper airway and respiratory sensation in people with OSA. This study was designed to determine the effects of 40 mg of MS-Contin on tactile sensation, respiratory load detection, and respiratory magnitude perception in people with OSA during wakefulness. A double-blind, randomized, crossover design (1 wk washout) was used. Twenty-one men with untreated OSA (apnea/hypopnea index = 26 ± 17 events/h) recruited from a larger clinical study completed the protocol. Tactile sensation using von Frey filaments on the back of the hand, internal mucosa of the cheek, uvula, and posterior pharyngeal wall were not different between placebo and morphine [e.g., median (interquartile range) posterior wall = 0.16 (0.16, 0.4) vs. 0.4 (0.14, 1.8) g, P = 0.261]. Similarly, compared with placebo, morphine did not alter respiratory load detection thresholds for nadir mask pressure detected = -2.05 (-3.37, -1.55) vs. -2.19 (-3.36, -1.41) cmH2O, P = 0.767], or respiratory load magnitude perception [mean ± SD Borg scores during a 5 resistive load (range: 5-126 cmH2O·l-1·s-1) protocol = 4.5 ± 1.6 vs. 4.2 ± 1.2, P = 0.347] but did reduce minute ventilation during quiet breathing (11.4 ± 3.3 vs. 10.7 ± 2.6 l/min, P < 0.01). These findings indicate that 40 mg of MS-Contin does not systematically impair tactile or respiratory sensation in men with mild to moderate, untreated OSA. This suggests that altered respiratory sensation to acute mechanical stimuli is not likely to be a mechanism that contributes to worsening of OSA with a moderate dose of morphine. NEW & NOTEWORTHY Forty milligrams of MS-Contin does not alter upper airway tactile sensation, respiratory load detection thresholds, or respiratory load magnitude perception in people with obstructive sleep apnea but does decrease breathing compared with placebo during wakefulness. Despite increasing concerns of harm with opioids, the current findings suggest that impaired respiratory sensation to acute mechanical stimuli with this dose of MS-Contin is unlikely to be a direct mechanism contributing to worsening sleep apnea severity in people with mild-to-moderate disease.


Subject(s)
Analgesics, Opioid/therapeutic use , Morphine/therapeutic use , Respiration/drug effects , Sleep Apnea, Obstructive/drug therapy , Touch/drug effects , Airway Obstruction/drug therapy , Arousal/drug effects , Cross-Over Studies , Double-Blind Method , Humans , Male , Middle Aged , Pharynx/drug effects , Pressure , Sleep/drug effects , Wakefulness/drug effects
SELECTION OF CITATIONS
SEARCH DETAIL
...