Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Language
Publication year range
1.
Preprint in English | bioRxiv | ID: ppbiorxiv-506305

ABSTRACT

We identified novel neutralizing monoclonal antibodies against SARS-CoV-2 variants (including Omicron) from individuals received two doses of mRNA vaccination after they had been infected with wildtype. We named them MO1, MO2 and MO3. MO1 shows high neutralizing activity against authentic variants: D614G, Delta, BA.1, BA.1.1, BA.2, and BA.2.75 and BA.5. Our findings confirm that the wildtype-derived vaccination can induce neutralizing antibodies that recognize the epitopes conserved among the SARS-CoV-2 variants (including BA.5 and BA.2.75). The monoclonal antibodies obtained herein could serve as novel prophylaxis and therapeutics against not only current SARS-CoV-2 viruses but also future variants that may arise.

2.
Gut and Liver ; : 817-825, 2020.
Article in English | WPRIM (Western Pacific) | ID: wpr-833166

ABSTRACT

Background/Aims@#Recently, a three-plane symmetric nee-dle with Franseen geometry was developed for endoscopic ultrasound-guided fine needle biopsy (EUS-FNB). In this ret-rospective study, tissue acquisition per pass was compared between 22-gauge Franseen FNB and standard fine needle aspiration (FNA) needles in patients with solid pancreatic le-sions. @*Methods@#Consecutive patients who underwent EUSFNA or EUS-FNB for solid pancreatic lesions between Octo-ber 2014 and March 2018 were retrospectively studied. The tissue acquisition rate and the diagnostic performance per session, per pass, and at first pass were compared. @*Results@#A total of 663 passes (300 by the FNB needle and 363 by the standard FNA needle) were performed in 154 patients (71 FNB and 83 FNA). The tissue acquisition rate per session and at first pass in the FNB and FNA groups was 100% and 95% (p=0.13) and 87% and 69% (p=0.007), respectively. The multivariate analysis revealed that among the patients, EUS-FNB (odds ratio, 3.07; p=0.01) was associated with a higher first-pass tissue acquisition rate. While the tissue ac-quisition rate reached a plateau after the 4th pass with FNA, it reached a plateau after the 2nd pass with FNB. Among the 129 malignant cases, the histological tissue acquisition rate per session was similar (100% and 94%), but the sensitivity by histology alone per session was higher for FNB than for FNA (93% and 73%, p<0.01). @*Conclusions@#The results of our retrospective analysis indicated that compared with a standard FNA needle, a 22-gauge Franseen FNB needle was associated with a higher first-pass tissue acquisition rate.

SELECTION OF CITATIONS
SEARCH DETAIL
...