1.
Arq. odontol ; 60: 36-43, 2024. ilus, tab
Article in Portuguese | BBO - Dentistry , LILACS | ID: biblio-1562478

ABSTRACT

Objetivo:Comparar os métodos radiográficos convencional e digital na Odontometria de molares inferiores. Materiais e Métodos: Foram selecionados 26 dentes e inseridos em recipientes com gesso e serragem para simular o osso alveolar. Após adequado acesso endodôntico, limas K#15 foram posicionadas nos canais mésio-vestibular e distal, 1mm aquém da patência foraminal (CT1). Foi construído um dispositivo em resina, onde fixou-se um medidor de ângulos padronizando a angulação horizontal em 20º para distal. O ângulo vertical foi 0º com distância foco-filme de 30 centímetros. Foi utilizado um aparelho de Rx de 70 KVp e 8 mA e exposição de 0,4 segundos. Para obtenção do CT radiográfico (CT2), posicionou-se o paquímetro na borda inferior do cursor até a ponta da lima. As mesmas medidas foram realizadas nas radiografias digitais obtidas com um sensor CMOS. A ferramenta "régua" foi utilizada determinando-se o CT digital (CT3). O teste de Correlação Intraclasse verificou concordâncias intragrupo e intergrupos e os testes Anova OneWay e Tukey (α = 0,05) foram usados para análise comparativa entre CT1, CT2 e CT3. Resultados: Tanto as medidas convencionais quanto as digitais apresentaram excelente concordância intragrupo (0,9842 e 0,9943, respectivamente). A concordância entre as mensurações para o CT digital foi maior em relação às medidas reais (0,8162) que as medidas do CT convencional (0,6761). A média e desvio padrão para CT1, CT2 e CT3 foram 18,4±1,4; 19,2±1,6 e 18,8±1,2mm, respectivamente. O teste de Tukey indicou diferença estatística entre CT1 e CT2 (p = 0,027); já entre CT1 e CT3 (p = 0,499) e entre CT2 e CT3 (p = 0,314) não houve diferenças significativas. Conclusão: As radiografias digitais propiciaram maior precisão na Odontometria de molares inferiores nas condições experimentais avaliadas.


Objective: To compare conventional and digital radiographic methods in Odontometry of lower molars. Materials and Methods:Twenty-six teeth were selected and inserted into containers with plaster and sawdust to simulate the alveolar bone. After adequate endodontic access, K#15 files were positioned in the mesiobuccal and distal canals, 1 mm below the foraminal patency (CT1).A resin device was constructed, where an angle gauge was fixed, standardizing the horizontal angulation at 20º distally. The vertical angle was 0º with a focus-film distance of 30 cm. An Rx device of 70 KVp and 8 mA, with an exposure time of 0.4 seconds, was used. To obtain the radiographic CT (CT2), the caliper was positioned on the lower edge of the cursor up to the tip of the file. The same measurements were performed on digital radiographs, obtained with a CMOS sensor. The "ruler" tool was used to determine the digital CT (CT3). The Intra-Class Correlation test was used to verify intra-group and intergroup agreements, and the Anova One-way and Tukey tests (α = 0.05) were used for comparative analysis between CT1, CT2, and CT3. Results: Both conventional and digital measurements had excellent intra-group agreement (0.9842 and 0.9943, respectively). The agreement between measurements for digital CT was greater in relation to real measurements (0.8162) than conventional CT measurements (0.6761). The mean and standard deviation for CT1, CT2, and CT3 were 18.4±1.4; 19.2±1.6; and 18.8±1.2, respectively. The Tukey test indicated a statistical difference between CT1 and CT2 (p = 0.027); Between CT1 and CT3 (p = 0.499) and between CT2 and CT3 (p = 0.314) no significant differences were observed. Conclusion:Digital radiographs provided greater precision in the odontometry of lower molars according to the experimental conditions evaluated in this study.


Subject(s)
Radiography, Dental , Radiography, Dental, Digital , Molar , Odontometry
2.
RFO UPF ; 28(1)20230808.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1537700

ABSTRACT

Introdução: Atualmente, braquetes autoligados têm sido sugeridos para reduzir o tempo de tratamento na Ortodontia. Objetivo: Dessa maneira, o presente estudo objetivou revisar a literatura acerca do tempo de tratamento com esses braquetes, em comparação com outros braquetes e tratamentos sugeridos. Revisão de literatura: Foi realizada pesquisa bibliográfica de caráter descritivo, que compreendeu o levantamento de referencial teórico na base de dados eletrônica Medline ­ PubMed. A seleção de artigos foi feita a partir dos títulos e resumos e a revisão compreendeu 4 artigos publicados na língua inglesa no período de 2019 a 2023. Conclusão: Há uma escassez de estudos clínicos envolvendo essa temática e o tratamento ortodôntico com aparelhos autoligados parece apresentar menor tempo de tratamento em comparação com aparelhos fixos tradicionais. No entanto, os estudos não mostraram diferenças estatisticamente significativas na redução desse tempo. Pode-se sugerir que mais estudos clínicos sejam conduzidos no intuito de elucidar essa questão.


Introduction: Currently, self-ligating brackets have been suggested to reduce treatment time in Orthodontics. Objective: Therefore, the present study aimed to review the literature about the treatment time with these brackets, in comparison with other brackets and suggested treatments. Literature review: Descriptive bibliographical research was carried out, which included the survey of theoretical references in the electronic database Medline ­ PubMed. The selection of articles was made based on titles and abstracts and the review comprised 4 articles published in the English language from 2019 to 2023. Conclusion: there is a shortage of clinical studies involving this topic and orthodontic treatment with self-ligating appliances seems to present shorter treatment time compared to traditional fixed appliances. However, the studies did not show statistically significant differences in reducing this time. It can be suggested that more clinical studies be conducted to elucidate this issue.