1.
Biosensors (Basel) ; 13(7)2023 Jul 03.
Article in English | MEDLINE | ID: mdl-37504102

ABSTRACT

Effective monitoring of respiratory disturbances during sleep requires a sensor capable of accurately capturing chest movements or airflow displacement. Gold-standard monitoring of sleep and breathing through polysomnography achieves this task through dedicated chest/abdomen bands, thermistors, and nasal flow sensors, and more detailed physiology, evaluations via a nasal mask, pneumotachograph, and airway pressure sensors. However, these measurement approaches can be invasive and time-consuming to perform and analyze. This work compares the performance of a non-invasive wearable stretchable morphic sensor, which does not require direct skin contact, embedded in a t-shirt worn by 32 volunteer participants (26 males, 6 females) with sleep-disordered breathing who performed a detailed, overnight in-laboratory sleep study. Direct comparison of computed respiratory parameters from morphic sensors versus traditional polysomnography had approximately 95% (95 ± 0.7) accuracy. These findings confirm that novel wearable morphic sensors provide a viable alternative to non-invasively and simultaneously capture respiratory rate and chest and abdominal motions.


Subject(s)
Respiratory Rate , Sleep Apnea Syndromes , Male , Female , Humans , Polysomnography , Sleep/physiology , Sleep Apnea Syndromes/diagnosis , Respiration
2.
Ann Am Thorac Soc ; 20(9): 1316-1325, 2023 09.
Article in English | MEDLINE | ID: mdl-37159953

ABSTRACT

Rationale: Oral appliance therapy (OAT) is an effective treatment for many people with obstructive sleep apnea (OSA). However, OSA pathogenesis is heterogeneous, and, in ∼50% of cases, OAT does not fully control OSA. Objectives: This study aimed to control OSA in individuals with an incomplete response to OAT alone by using additional targeted therapies informed by OSA endotype characterization. Methods: Twenty-three people with OSA (apnea-hypopnea index [AHI], 41 ± 19 events/h) not fully resolved (AHI, >10 events/h) with OAT alone were prospectively recruited. OSA endotypes were characterized pretherapy during a detailed physiology study night. Initially, an expiratory positive airway pressure (EPAP) valve and supine avoidance device therapy were added to target the impaired anatomical endotype. Those with residual OSA (AHI, >10 events/h) then received one or more nonanatomical interventions based on endotype characterization. This included O2 (4 L/min) to reduce high loop gain (unstable respiratory control) and 80/5 mg atomoxetine-oxybutynin to increase pharyngeal muscle activity. Finally, if required, OAT was combined with EPAP and continuous positive airway pressure (CPAP) therapy. Results: Twenty participants completed the study. OSA was successfully controlled (AHI, <10 events/h) with combination therapy in all but one participant (17 of 20 without CPAP). OAT plus EPAP and supine avoidance therapy treated OSA in 10 (50%) participants. OSA was controlled in five (25%) participants with the addition of O2 therapy, one with atomoxetine-oxybutynin, and one required O2 plus atomoxetine-oxybutynin. Two participants required CPAP for their OSA, and another was CPAP intolerant. Conclusions: These novel prospective findings highlight the potential of precision medicine to inform targeted combination therapy to treat OSA. Clinical trial registered with the Australian New Zealand Clinical Trials Registry (ACTRN12618001995268).


Subject(s)
Sleep Apnea, Obstructive , Humans , Atomoxetine Hydrochloride/therapeutic use , Prospective Studies , Australia , Sleep Apnea, Obstructive/drug therapy
3.
J Clin Sleep Med ; 18(3): 861-870, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-34710038

ABSTRACT

STUDY OBJECTIVES: Oral appliance (OA) therapy is a well-tolerated alternative to continuous positive airway pressure. However, it is less efficacious. A major unresolved clinical challenge is the inability to accurately predict who will respond to OA therapy. We recently developed a model to estimate obstructive sleep apnea pathophysiological endotypes. This study aimed to apply this physiological-based model to predict OA treatment responses. METHODS: Sixty-two men and women with obstructive sleep apnea (aged 29-71 years) were studied to investigate the efficacy of a novel OA device. An in-laboratory diagnostic followed by an OA treatment efficacy polysomnography were performed. Seven polysomnography variables from the diagnostic study plus age and body mass index were included in our machine-learning-based model to predict OA therapy response according to standard apnea-hypopnea index (AHI) definitions. Initially, the model was trained on data from the first 45 participants using 10-fold cross-validation. A blinded independent validation was then performed for the remaining 17 participants. RESULTS: Mean accuracy of the trained model to predict OA therapy responders vs nonresponders (AHI < 5 events/h) using 10-fold cross-validation was 91% ± 8%. In the independent blinded validation, 100% (AHI < 5 events/h); 59% (AHI < 10 events/h); 71% (50% reduction in AHI); and 82% (50% reduction in AHI to < 20 events/h) of the 17 participants were correctly classified for each of the treatment outcome definitions respectively. CONCLUSIONS: While further evaluation in larger clinical data sets is required, these findings highlight the potential to use routinely collected sleep study and clinical data with machine learning-based approaches underpinned by obstructive sleep apnea endotype concepts to help predict treatment outcomes to OA therapy for people with obstructive sleep apnea. CITATION: Dutta R, Tong BK, Eckert DJ. Development of a physiological-based model that uses standard polysomnography and clinical data to predict oral appliance treatment outcomes in obstructive sleep apnea. J Clin Sleep Med. 2022;18(3):861-870.


Subject(s)
Mandibular Advancement , Sleep Apnea, Obstructive , Adult , Aged , Continuous Positive Airway Pressure , Female , Humans , Male , Middle Aged , Polysomnography , Sleep Apnea, Obstructive/diagnosis , Sleep Apnea, Obstructive/therapy , Treatment Outcome
4.
J Appl Physiol (1985) ; 129(5): 1085-1091, 2020 11 01.
Article in English | MEDLINE | ID: mdl-32909921

ABSTRACT

Oral appliance (OA) therapy is the leading alternative to continuous positive airway pressure (CPAP) for obstructive sleep apnea (OSA). It is well tolerated compared with CPAP. However, ≥50% of patients using OA therapy have incomplete resolution of their OSA. Combination therapy with CPAP and oral appliance (CPAP + OA) is a potential alternative for incomplete responders to OA therapy. This study aimed to determine the extent to which combination therapy reduces therapeutic CPAP requirements using gold-standard physiological methodology in those who have an incomplete response to OA therapy alone. Sixteen incomplete responders [residual apnea/hypopnea index (AHI) > 10 events/h] to a novel OA with a built-in oral airway were recruited (3 women:13 men, aged 31-65 yr, body mass index: 22-38 kg/m2, residual AHI range: 13-63 events/h). Participants were fitted with a nasal mask, pneumotachograph, epiglottic pressure catheter, and standard polysomnography equipment. CPAP titrations were performed during non-rapid eye movement (NREM) supine sleep in each participant during three conditions (order randomized): CPAP only, CPAP + OA (oral airway open), and CPAP + OA (oral airway closed). OSA was resolved at pressures of 4 ± 2 and 5 ± 2 cmH2O during CPAP + OA (oral airway open) and CPAP + OA (oral airway closed) conditions versus 8 ± 2 cmH2O during CPAP only (P < 0.01). Negative epiglottic pressure swings in oral airway open and closed conditions were normalized to CPAP only levels [-2.5(-3.7, -2.6) vs. -2.3(-3.2, -2.4) vs. -2.1(-2.7, -2.3) cmH2O]. Combined CPAP and OA therapy reduces therapeutic CPAP requirements by 35%-45% and minimizes epiglottic pressure swings. This combination may be a therapeutic alternative for patients with incomplete responses to OA therapy alone and those who cannot tolerate high CPAP levels.NEW & NOTEWORTHY Combined CPAP and oral appliance therapy has been suggested as an alternative for incomplete responders to oral appliance therapy. We used a novel oral appliance incorporating an oral airway together with CPAP to show that pharyngeal pressure swings were normalized at reduced CPAP levels. Our findings demonstrate that using CPAP and oral appliance together may be a beneficial alternative for incomplete responders to oral appliance therapy and intolerant CPAP users due to high-pressure requirements.


Subject(s)
Continuous Positive Airway Pressure , Mandibular Advancement , Sleep Apnea, Obstructive , Adult , Aged , Female , Humans , Male , Middle Aged , Pharynx , Polysomnography , Sleep Apnea, Obstructive/therapy
5.
Sleep ; 43(10)2020 10 13.
Article in English | MEDLINE | ID: mdl-32267509

ABSTRACT

STUDY OBJECTIVES: Quantification of upper airway collapsibility in obstructive sleep apnea (OSA) could help inform targeted therapy decisions. However, current techniques are clinically impractical. The primary aim of this study was to assess if a simple, novel technique could be implemented as part of a continuous positive airway pressure (CPAP) titration study to assess pharyngeal collapsibility. METHODS: A total of 35 participants (15 female) with OSA (mean ± SD apnea-hypopnea index = 35 ± 19 events/h) were studied. Participants first completed a simple clinical intervention during a routine CPAP titration, where CPAP was transiently turned off from the therapeutic pressure for ≤5 breaths/efforts on ≥5 occasions during stable non-rapid eye movement (non-REM) sleep for quantitative assessment of airflow responses (%peak inspiratory flow [PIF] from preceding 5 breaths). Participants then underwent an overnight physiology study to determine the pharyngeal critical closing pressure (Pcrit) and repeat transient drops to zero CPAP to assess airflow response reproducibility. RESULTS: Mean PIF of breaths 3-5 during zero CPAP on the simple clinical intervention versus the physiology night were similar (34 ± 29% vs. 28 ± 30% on therapeutic CPAP, p = 0.2; range 0%-90% vs. 0%-95%). Pcrit was -1.0 ± 2.5 cmH2O (range -6 to 5 cmH2O). Mean PIF during zero CPAP on the simple clinical intervention and the physiology night correlated with Pcrit (r = -0.7 and -0.9, respectively, p < 0.0001). Receiver operating characteristic curve analysis indicated significant diagnostic utility for the simple intervention to predict Pcrit < -2 and < 0 cmH2O (AUC = 0.81 and 0.92), respectively. CONCLUSIONS: A simple CPAP intervention can successfully discriminate between patients with and without mild to moderately collapsible pharyngeal airways. This scalable approach may help select individuals most likely to respond to non-CPAP therapies.


Subject(s)
Sleep Apnea, Obstructive , Continuous Positive Airway Pressure , Female , Humans , Pharynx/diagnostic imaging , Pressure , Reproducibility of Results , Sleep Apnea, Obstructive/therapy
6.
J Clin Sleep Med ; 16(4): 483-492, 2020 04 15.
Article in English | MEDLINE | ID: mdl-32003735

ABSTRACT

STUDY OBJECTIVES: High nasal resistance is associated with oral appliance treatment failure in obstructive sleep apnea (OSA). A novel oral appliance with a built-in oral airway has been shown to reduce pharyngeal pressure swings during sleep and may be efficacious in those with high nasal resistance. The role of posture and mandibular advancement on nasal resistance in OSA remains unclear. This study aimed to determine (1) the effects of posture and mandibular advancement on nasal resistance in OSA and (2) the efficacy of a new oral appliance device including in patients with high nasal resistance. METHODS: A total of 39 people with OSA (7 females, apnea-hypopnea index (AHI) (mean ± standard deviation) = 29 ± 21 events/h) completed split-night polysomnography with and without oral appliance (order randomized). Prior to sleep, participants were instrumented with a nasal mask, pneumotachograph, and a choanal pressure catheter for gold standard nasal resistance quantification seated, supine and lateral (with and without oral appliance, order randomized). RESULTS: Awake nasal resistance increased from seated, to supine, to lateral posture (median [interquartile range] = 1.8 [1.4, 2.7], 2.7 [1.7, 3.5], 3.4 [1.9, 4.6] cm H2O/L/s, P < .001). Corresponding measures of nasal resistance did not change with mandibular advancement (2.3 [1.4, 3.5], 2.5 [1.8, 3.6], 3.5 [1.9, 4.8] cm H2O/L/s, P = .388). The median AHI reduced by 47% with oral appliance therapy (29 ± 21 versus 18 ± 15 events/h, P = .002). Participants with high nasal resistance (> 3 cm H2O/L/s) had similar reductions in AHI versus those with normal nasal resistance (61 [-8, 82] versus 40 [-5, 62] %, P = .244). CONCLUSIONS: Nasal resistance changes with posture in people with OSA. A novel oral appliance with a built-in oral airway reduces OSA severity in people with OSA, including in those with high nasal resistance. CLINICAL TRIAL REGISTRATION: Registry: ANZCTR; Title: Combination therapy for obstructive sleep apnoea; Identifier: ACTRN12617000492358; URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=372279.


Subject(s)
Mandibular Advancement , Sleep Apnea, Obstructive , Continuous Positive Airway Pressure , Female , Humans , Polysomnography , Posture , Sleep Apnea, Obstructive/therapy , Treatment Outcome
7.
Sleep ; 42(8)2019 08 01.
Article in English | MEDLINE | ID: mdl-31180512

ABSTRACT

STUDY OBJECTIVES: Mandibular advancement splint (MAS) therapy is a well-tolerated alternative to continuous positive airway pressure for obstructive sleep apnea (OSA). Other therapies, including nasal expiratory positive airway pressure (EPAP) valves, can also reduce OSA severity. However, >50% of patients have an incomplete or no therapeutic response with either therapy alone and thus remain at risk of adverse health outcomes. Combining these therapies may yield greater efficacy to provide a therapeutic solution for many incomplete/nonresponders to MAS therapy. Thus, this study evaluated the efficacy of combination therapy with MAS plus EPAP in incomplete/nonresponders to MAS alone. METHODS: Twenty-two people with OSA (apnea-hypopnea index [AHI] = 22 [13, 42] events/hr), who were incomplete/nonresponders (residual AHI > 5 events/hr) on an initial split-night polysomnography with a novel MAS device containing an oral airway, completed an additional split-night polysomnography with MAS + oral EPAP valve and MAS + oral and nasal EPAP valves (order randomized). RESULTS: Compared with MAS alone, MAS + oral EPAP significantly reduced the median total AHI, with further reductions with the MAS + oral/nasal EPAP combination (15 [10, 34] vs. 10 [7, 21] vs. 7 [3, 13] events/hr, p < 0.01). Larger reductions occurred in supine nonrapid eye movement AHI with MAS + oral/nasal EPAP combination therapy (ΔAHI = 23 events/hr, p < 0.01). OSA resolved (AHI < 5 events/hr) with MAS + oral/nasal EPAP in nine individuals and 13 had ≥50% reduction in AHI from no MAS. However, sleep efficiency was lower with MAS + oral/nasal EPAP versus MAS alone or MAS + oral EPAP (78 ± 19 vs. 87 ± 10 and 88 ± 10% respectively, p < 0.05). CONCLUSIONS: Combination therapy with a novel MAS device and simple oral or oro-nasal EPAP valves reduces OSA severity to therapeutic levels for a substantial proportion of incomplete/nonresponders to MAS therapy alone. CLINICAL TRIALS: Name: Targeted combination therapy: Physiological mechanistic studies to inform treatment for obstructive sleep apnea (OSA)URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=372279 Registration: ACTRN12617000492358 (Part C).


Subject(s)
Continuous Positive Airway Pressure/methods , Mandibular Advancement/methods , Sleep Apnea, Obstructive/therapy , Sleep/physiology , Adult , Aged , Australia , Combined Modality Therapy , Continuous Positive Airway Pressure/instrumentation , Disease Progression , Female , Humans , Male , Mandibular Advancement/instrumentation , Middle Aged , Polysomnography
8.
Sleep ; 39(4): 757-66, 2016 Apr 01.
Article in English | MEDLINE | ID: mdl-26715227

ABSTRACT

STUDY OBJECTIVES: To determine the effects of the nonbenzodiazepine sedative zopiclone on the threshold to arousal with increasing respiratory effort and genioglossus muscle activity and to examine potential physiological factors mediating disparate effects of zopiclone on obstructive sleep apnea (OSA) severity between patients. METHODS: Twelve patients with OSA (apnea-hypopnea index = 41 ± 8 events/h) were studied during 2 single night sleep studies conducted approximately 1 w apart after receiving 7.5 mg of zopiclone or placebo according to a double-blind, placebo-controlled, randomized, crossover design. The respiratory arousal threshold (epiglottic pressure immediately prior to arousal during naturally occurring respiratory events), genioglossus activity and its responsiveness to pharyngeal pressure during respiratory events, and markers of OSA severity were compared between conditions. Genioglossus movement patterns and upper airway anatomy were also assessed via magnetic resonance imaging in a subset of participants (n = 7) during wakefulness. RESULTS: Zopiclone increased the respiratory arousal threshold versus placebo (-31.8 ± 5.6 versus -26.4 ± 4.6 cmH2O, P = 0.02) without impairing genioglossus muscle activity or its responsiveness to negative pharyngeal pressure during respiratory events (-0.56 ± 0.2 versus -0.44 ± 0.1 %max/-cmH2O, P = 0.48). There was substantial interindividual variability in the changes in OSA severity with zopiclone explained, at least in part, by differences in pathophysiological characteristics including body mass index, arousal threshold, and genioglossus movement patterns. CONCLUSIONS: In a group of patients with predominantly severe OSA, zopiclone increased the arousal threshold without reducing genioglossus muscle activity or its responsiveness to negative pharyngeal pressure. These properties may be beneficial in some patients with OSA with certain pathophysiological characteristics but may worsen hypoxemia in others. CLINICAL TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry, http://www.anzctr.org.au, trial ID: ACTRN12614000364673.


Subject(s)
Arousal/drug effects , Azabicyclo Compounds/pharmacology , Azabicyclo Compounds/therapeutic use , Piperazines/pharmacology , Piperazines/therapeutic use , Sleep Apnea, Obstructive/physiopathology , Tongue/drug effects , Adolescent , Adult , Aged , Australia , Body Mass Index , Cross-Over Studies , Double-Blind Method , Female , Humans , Hypnotics and Sedatives/pharmacology , Hypnotics and Sedatives/therapeutic use , Male , Middle Aged , Movement/drug effects , New Zealand , Pharynx/drug effects , Polysomnography , Pressure , Respiration/drug effects , Tongue/physiology , Wakefulness/drug effects , Young Adult