Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Omega ; 7(37): 32897-32907, 2022 Sep 20.
Article in English | MEDLINE | ID: mdl-36157742

ABSTRACT

Affinity chromatography is a well-known method dependent on molecular recognition and is used to purify biomolecules by mimicking the specific interactions between the biomolecules and their substrates. Enzyme substrates, cofactors, antigens, and inhibitors are generally utilized as bioligands in affinity chromatography. However, their cost, instability, and leakage problems are the main drawbacks of these bioligands. Biomimetic affinity ligands can recognize their target molecules with high selectivity. Their cost-effectiveness and chemical and biological stabilities make these antibody analogs favorable candidates for affinity chromatography applications. Biomimetics applies to nature and aims to develop nanodevices, processes, and nanomaterials. Today, biomimetics provides a design approach to the biomimetic affinity ligands with the aid of computational methods, rational design, and other approaches to meet the requirements of the bioligands and improve the downstream process. This review highlighted the recent trends in designing biomimetic affinity ligands and summarized their binding interactions with the target molecules with computational approaches.

2.
Micromachines (Basel) ; 12(9)2021 Sep 10.
Article in English | MEDLINE | ID: mdl-34577735

ABSTRACT

In this work, a surface plasmon resonance (SPR) based immunosensor was prepared by the immobilization of the amine-functionalized gold nanoparticles (N-AuNPs) on the sensing surface to sense immunoglobulin M (IgM) antibodies in the aqueous solution and artificial plasma. The characterization studies of SPR based immunosensor for IgM detection were performed with scanning electron microscope (SEM), contact angle measurements, and ellipsometry. Kinetic studies for the IgM immunosensor were carried out in the range of 1.0 to 200 ng/mL IgM concentrations in an aqueous solution. The total IgM analysis time including adsorption, desorption, and regeneration cycles was nearly 10 min for the prepared immunosensor. The limit of detection (LOD) and limit of quantification (LOQ) were found as 0.08 and 0.26 ng/mL, respectively. The reusability of the proposed immunosensor was tested with 6 consecutive adsorption-desorption, and regeneration cycles. Also, enzyme-linked immunosorbent assay (ELISA) method was utilized in the validation of the immunosensor.

3.
Talanta ; 212: 120778, 2020 May 15.
Article in English | MEDLINE | ID: mdl-32113541

ABSTRACT

Tailor-made Escherichia coli (E. coli) receptors were created with microcontact imprinted technique and binding events of E. coli were carried out by a surface plasmon resonance (SPR) sensor in aqueous solution and in urine mimic in real time and label-free. N-methacryloyl-(l)-histidine methyl ester (MAH) was selected as a functional monomer to design tailor-made E. coli receptors on the polymeric film and during the formation of the polymeric film on a chip surface, Ag nanoparticles (AgNPs) were entrapped into the polymer mixture in order to lower the detection limit of biomimetic SPR based sensor. The polymeric film was characterized with atomic force microscopy (AFM), scanning electron microscopy (SEM), ellipsometer and contact angle measurements. Limit of detection (LOD) was found 0.57 CFU/mL and feasibility of the biomimetic sensor was investigated in urine mimic.


Subject(s)
Bacterial Typing Techniques/methods , Escherichia coli/isolation & purification , Polymethacrylic Acids/chemistry , Surface Plasmon Resonance/methods , Urinary Tract Infections/diagnosis , Biomimetics/methods , Histidine/analogs & derivatives , Histidine/chemistry , Limit of Detection , Metal Nanoparticles/chemistry , Methacrylates/chemistry , Molecular Imprinting , Silver/chemistry , Urine/microbiology
4.
Gels ; 6(1)2020 Jan 29.
Article in English | MEDLINE | ID: mdl-32013072

ABSTRACT

Human immunoglobulin M (hIgM) antibodies are considered as hopeful tools for diseases therapy. Therefore, chromatography approaches are used to purify hIgM with a single step. In this study, we prepared a poly(hydroxyethyl methacrylate) based immunoaffinity p(HEMA-I) cryogel column by using cyanamide to immobilize antihuman immunoglobulin on the p(HEMA) cryogel for purification of hIgM in aqueous solution and artificial human plasma. The characterization of the p(HEMA) cryogel column was performed by using a scanning electron microscope (SEM), micro-computerized tomography (µ-CT), Fourier transform infrared spectroscopy (FTIR), swelling degree and macro-porosity. Further, the optimizations of various parameters were performed such as, pH, ionic strength, temperature and concentration of hIgM in aqueous solutions. In addition, the Langmuir adsorption model was supported by experimental results. Maximum adsorbed amount of hIgM corresponded to 11.1 mg/g at pH 5.75 [morpholino ethanesulfonic acid (MES buffer)]. Our results indicated that the p(HEMA-I) cryogel column can be reused at least 10 times without significant loss in adsorption capacity. As a natural source, artificial human plasma was selected for hIgM adsorption and the purity of hIgM was evaluated using sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE).

5.
J Biomater Sci Polym Ed ; 28(6): 519-531, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28105892

ABSTRACT

In this study, cryogel-based implantable molecularly imprinted drug delivery systems were designed for the delivery of antineoplastic agent. Mitomycin C imprinted poly(2-hydroxyethyl methacrylate-N-methacryloyl-l-glutamic acid) cryogel membranes were produced by free-radical bulk polymerization under partially frozen conditions. The membranes were characterized by swelling tests, Fourier transform infrared spectroscopy, scanning electron microscopy, surface area measurements and in vitro hemocompatibility tests. In vitro delivery studies were carried out to examine the effects of cross-linker ratio and template content. Mitomycin C imprinted cryogel membranes have megaporous structure (10-100 µm in diameter). The cumulative release of mitomycin C was decreased with increasing cross-linking agent ratio and increased with the amount of template in the cryogel structure. The nature of transport mechanism of the mitomycin C from the membranes was non-Fickian.


Subject(s)
Acrylic Resins/chemistry , Cryogels/chemistry , Membranes, Artificial , Mitomycin/chemistry , Mitomycin/pharmacology , Molecular Imprinting/methods , Adsorption , Animals , Cell Line , Cell Survival , Cross-Linking Reagents/chemistry , Drug Delivery Systems , Drug Liberation , Humans , Materials Testing/methods , Mice , Polymerization , Porosity , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...