Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Craniofac Surg ; 2024 May 20.
Article in English | MEDLINE | ID: mdl-38767364

ABSTRACT

OBJECTIVE: In this study, we aimed to compare the efficiency of different osteotomy techniques for Lefort 1 osteotomy in an experimental caprine skull model. METHODS: Twelve caprine skulls were used for the study. Skulls were divided into 3 groups: (1) manual chisel group, (2) Lindemann bur group, and (3) piezo osteotomy group. Bilateral osteotomies were performed on each skull. Results were evaluated with three-dimensional computerized tomography scans and macroscopic observations of the mucosal tears and soft tissue. RESULTS: The mean length of the bone gap in the manual, Lindemann, and piezo groups was 4.8 (±0.7), 3.38 (±1.49), and 1.39 (±0.3) mm, respectively (P < 0.05). The mean number of comminuted fractures in the manual, Lindemann, and piezo groups was 5.5 (±1.4), 1.6 (±0.3), and 0.6 (±0.5), respectively (P < 0.05). Mucosal tearing and soft tissue damage based on subjective inspection observations were negligible in the piezo technique. Soft tissue and mucosal damage were observed significantly more in the manual chisel osteotomy method compared with the other 2 techniques. CONCLUSION: We anticipate that piezo, which has started to be used in new application areas besides rhinoplasty, will continue to be used more widely, especially in reconstructive orthognathic surgery, due to the minimal damage it causes to tissues. With the long-term results, much healthier interpretations can be made.

2.
J Craniofac Surg ; 34(8): e785-e788, 2023.
Article in English | MEDLINE | ID: mdl-37646346

ABSTRACT

OBJECTIVE: The objective of this study was to investigate of the effect of piezzo and conventional osteotomy techniques on bone reserve in the osteotomy line and comminuted fracture ratios that is able to compromise bone to bone contact negatively. METHODS: Bilateral sagittal split ramus osteotomy was performed on 12 fresh male Thracian curly caprine mandible. In the first group (n: 12) osteotomies were performed with piezzo device. In the second group (n: 12) osteotomies were performed with micromotor and manual osteotomes. Operative time was measured. The number of comminuted fractures, length and width of the osteotomy, and the space between the osteotomy lines was evaluated from 3-dimensional computed tomography scans. RESULTS: The mean value of procedure duration was 320.4±10.76 seconds for piezo osteotomy and 238.8±8.29 seconds for conventional micromotor ( P <0.0001). Number of comminuted fractures was 1.41±1.3 in piezoelectric group, 1.5±1.3 in conventional group and the difference was not statistically significant (p: 0,88). Osteotomy lengths and widths were 35.58±5.2, 2.196±1.9 and 36.23±5.05, 2.27±1.85 in the piezzo and conventional groups, respectively. (p lengths :0,75; p widths :0,92) The volume of the bony interface between the distal and proximal segments of the mandible after osteotomy was 166.3±184.2 mm 3 in the piezzo group and 163.5±129.3 mm 3 in the conventional group (p: 0,96). CONCLUSION: The piezo surgery and the conventional osteotomy were found to be similar in terms of the gap between the distal and proximal mandible and the number of comminuted fractures. The duration to perform the conventional osteotomy was found to be shorter than the piezo surgery.


Subject(s)
Fractures, Comminuted , Goats , Humans , Male , Animals , Fractures, Comminuted/diagnostic imaging , Fractures, Comminuted/surgery , Mandible/diagnostic imaging , Mandible/surgery , Osteotomy, Sagittal Split Ramus/methods , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...