Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
2.
J Am Soc Echocardiogr ; 16(1): 61-6, 2003 Jan.
Article in English | MEDLINE | ID: mdl-12514636

ABSTRACT

Multiplane transesophageal echocardiography is a useful tool to study mitral regurgitation. We evaluated the diagnostic accuracy of multiplane transesophageal echocardiography performed according to the guidelines of the American Society of Echocardiography. We used 4 midesophageal and 2 transgastric views in 313 patients with degenerative lesions, endocarditic lesions, or both to identify regurgitant defects, comparing transesophageal echocardiography results with surgical findings. The overall diagnostic accuracy using individual scallops was 97.2% (P <.00001) with a sensitivity of 96.6% and a specificity of 97.6%. Considering the single sections of the mitral valve, an accuracy of 98%, 97.1%, and 98%, was found, respectively, for the lateral, middle, and medial third of the anterior leaflet. For the posterior leaflet, the accuracy was 98% for the lateral scallop, 98.4% for the middle, and 96.1% for the medial. This strategy provides good accuracy in diagnosing both simple and challenging mitral-valve lesions and its widespread use should be recommended.


Subject(s)
Echocardiography, Transesophageal/standards , Endocarditis/diagnosis , Flail Chest/diagnosis , Mitral Valve Prolapse/diagnosis , Societies, Medical , Adult , Aged , Americas , Diagnosis, Differential , Diagnostic Techniques, Surgical/standards , Endocarditis/epidemiology , Female , Flail Chest/epidemiology , Humans , Intraoperative Care/standards , Male , Middle Aged , Mitral Valve/pathology , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/epidemiology , Mitral Valve Prolapse/epidemiology , Observer Variation , Sensitivity and Specificity , Statistics as Topic
3.
Am J Cardiol ; 91(2): 175-9, 2003 Jan 15.
Article in English | MEDLINE | ID: mdl-12521630

ABSTRACT

Residual mitral regurgitation (MR) after repair is a risk factor for late reoperation. The use of intraoperative transesophageal echocardiography (IOTEE) decreases the incidence of immediate repair failure. This study identifies the mechanisms of immediate failure by IOTEE in the quadrangular resection technique, a well-standardized mitral valve repair procedure to guide further repair procedures. Two hundred five consecutive patients underwent quadrangular resection due to prolapse or flail posterior leaflet. Twenty-four patients (11%) had immediate failure. Immediate reinstitution of cardiopulmonary bypass ("second pump run") was needed in 21 patients (10%) for further repair. The identified mechanisms of failure were residual cleft provoking interscallop malcoaptation into the posterior leaflet in 8 patients, residual prolapse of the anterior or posterior leaflets in 1 and 4 patients, respectively, residual annular dilation in 3, left ventricular outflow obstruction in 2, suture dehiscence in 2, and other mechanisms in another 2 patients. In 20 patients (95%), IOTEE guided further repair with resolution of the residual MR, whereas 1 patient underwent valve replacement due to pharmacologically untreatable left ventricular outflow obstruction. In conclusion, even if this type of valve repair technique is well standardized, the incidence of immediate failure is not negligible. IOTEE identified the mechanisms of the immediate failure and guided further repair procedures, thus reducing the incidence of valve replacement (0.5%) without increasing perioperative mortality and morbility.


Subject(s)
Echocardiography, Transesophageal , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Adult , Aged , Cardiopulmonary Bypass , Female , Humans , Intraoperative Complications , Male , Middle Aged , Mitral Valve/pathology , Mitral Valve Insufficiency/pathology , Treatment Failure , Ventricular Dysfunction, Left/etiology
SELECTION OF CITATIONS
SEARCH DETAIL
...