Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Cardiol Res Pract ; 2024: 6664482, 2024.
Article in English | MEDLINE | ID: mdl-38204600

ABSTRACT

Background: Using a fluid-filled wire with a pressure sensor outside the patient compared to a conventional pressure wire may avoid the systematic error introduced by the hydrostatic pressure within the coronary circulation. Aims: To assess the safety and effectiveness of the novel fluid-filled wire, Wirecath (Cavis Technologies, Uppsala, Sweden), as well as its ability to avoid the hydrostatic pressure error. Methods and Results: The Wirecath pressure wire was used in 45 eligible patients who underwent invasive coronary angiography and had a clinical indication for invasive coronary pressure measurement at Sahlgrenska University Hospital, Gothenburg, Sweden. In 29 patients, a simultaneous measurement was performed with a conventional coronary pressure wire (PressureWire X, Abbott Medical, Plymouth, MN, USA), and in 19 patients, the vertical height difference between the tip of the guide catheter and the wire measure point was measured in a 90-degree lateral angiographic projection. No adverse events caused by the pressure wires were reported. The mean Pd/Pa and mean FFR using the fluid-filled wire and the sensor-tipped wire differed significantly; however, after correcting for the hydrostatic effect, the sensor-tipped wire pressure correlated well with the fluid-filled wire pressure (R = 0.74 vs. R = 0.89 at rest and R = 0.89 vs. R = 0.98 at hyperemia). Conclusion: Hydrostatic errors in physiologic measurements can be avoided by using the fluid-filled Wirecath wire, which was safe to use in the present study. This trial is registered with NCT04776577 and NCT04802681.

2.
JACC Cardiovasc Interv ; 11(16): 1590-1597, 2018 08 27.
Article in English | MEDLINE | ID: mdl-30139465

ABSTRACT

OBJECTIVES: In this substudy of the DETO2X-AMI (An Efficacy and Outcome Study of Supplemental Oxygen Treatment in Patients With Suspected Myocardial Infarction) trial, the authors aimed to assess the analgesic effect of moderate-flow oxygen supplementation in patients with suspected acute myocardial infarction (AMI) treated with percutaneous coronary intervention (PCI) and to study the effect of oxygen supplementation on the use of opiates and sedatives during PCI. BACKGROUND: Routine oxygen in normoxemic patients with AMI does not provide clinical benefit. However, oxygen may relieve ischemic pain. METHODS: Patients were randomly allocated to oxygen or ambient air according to the main study protocol. After PCI, peak level of pain during PCI was measured by the Visual Analogue Scale. The total amount of opiates and sedatives was reported. RESULTS: A total of 622 patients were enrolled: 330 in the oxygen group and 292 in the ambient air group. There was no significant difference in peak level of pain (oxygen 4.0 [1.0 to 6.0] vs. air 3.0 [0.6 to 6.0]; p = 0.37), use of opiates (mg) (oxygen 0.0 [0.0 to 3.0] vs. air 0.0 [0.0 to 3.0]; p = 0.31), or use of sedatives between the groups (median [interquartile range]) (oxygen 2.5 [0.0 to 2.5] vs. air 2.5 [0.0 to 2.5]; p = 0.74). CONCLUSIONS: In the present study, the authors did not find any analgesic effect of routine oxygen as compared with ambient air, and no differences in the use of sedatives and opiates during PCI. Our results indicate that moderate-flow oxygen supplementation does not relieve pain in normoxemic patients with suspected AMI undergoing treatment with PCI and should thus not be used for this purpose.


Subject(s)
Myocardial Infarction/therapy , Oxygen Inhalation Therapy , Pain/prevention & control , Percutaneous Coronary Intervention/adverse effects , Aged , Analgesics, Opioid/administration & dosage , Female , Humans , Hypnotics and Sedatives/administration & dosage , Male , Middle Aged , Pain/diagnosis , Pain/etiology , Pain Measurement , Registries , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...