Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 771
Filter
1.
Nutr Hosp ; 2024 May 21.
Article in English | MEDLINE | ID: mdl-38804970

ABSTRACT

INTRODUCTION: medical nutritional treatment (MNT) can be complex and may be associated with potential metabolic complications, which has been recently described as nutritrauma. OBJECTIVE: the aim of our work is to describe whether the application of the nutritrauma concept in real life is feasible and useful to detect the metabolic complications associated with the prescription of MNT. MATERIAL AND METHODS: in this descriptive, prospective study at a single center we enrolled 30 consecutive critically ill patients in a 14-bed medical-surgical intensive care unit. The nutritrauma strategy implementation was based in four "M" steps: Metabolic screening, MNT prescription, biochemical Monitoring, and nutritional Management. RESULTS: we analyzed 28 patients (mean age, 69.7 ± 11.3 years; APACHE II, 18.1 ± 8.1; SOFA, 7.5 ± 3.7; Nutric Score, modified, 4.3 ± 2.01, and mean BMI, 27.2 ± 3.8). The main cause of admission was sepsis (46.4 %). Length of ICU stay was 20.6 ± 15.1 days; 39.3 % of subjects died during their ICU stay. Enteral nutrition (82.1 %) was more frequent than parenteral nutrition (17.9 %). During nutritional monitoring, 54 specific laboratory determinations were made. Hyperglycemia was the most frequent metabolic alteration (83.3 % of measurements). Electrolyte disturbances included hypocalcemia (50 %), hypophosphatemia (29.6 %) and hypokalemia (27.8 %). The most frequent lipid profile abnormalities were hypocholesterolemia (64.8 %) and hypertriglyceridemia (27.8 %). Furthermore, nutritional prescription was modified for 53.6 % of patients: increased protein dosage (25 %), increased calorie dosage (21.4 %) and change to organ-specific diet (17.8 %). CONCLUSIONS: in conclusion, the application of the nutritrauma approach facilitates detection of metabolic complications and an evaluation of the appropriate prescription of MNT.

2.
SEMERGEN, Soc. Esp. Med. Rural Gen. (Ed. Impr.) ; 49(6): [e101965], sept. 2023. tab
Article in Spanish | IBECS | ID: ibc-224798

ABSTRACT

Introducción La obesidad es una pandemia mundial con repercusión en morbilidad y mortalidad crecientes. Valoramos la fortaleza asociativa del índice de adiposidad visceral (VAI) y del índice de adiposidad disfuncional (DAI) en obesidad y riesgo asociado utilizando diversos métodos. Material y métodos Estudio transversal en 418.343 trabajadores de diferentes comunidades autónomas en España, estimando prevalencia de obesidad con: perímetro de cintura, Índice cintura/altura, IMC, CUN-BAE, ECORE-BF, RFM, Palafolls, IMG, METS-VF calculados ajustándose a sus fórmulas específicas. Se realizó análisis descriptivo de las variables categóricas y fortaleza asociativa de VAI y DAI para obesidad con curvas ROC considerando riesgo elevado cuando el valor AUC.0,8 y moderado con AUC.0,7 y.0,8. Se utilizó SPSS 27.0, considerando significación estadística p.0,05. Resultados La prevalencia de obesidad varía según el método utilizado, siendo alta con Palafolls (72,92% en mujeres y 86,98% en hombres) y baja con METS-VF (1,31% en mujeres y 8,54% en hombres). Los valores medios de VAI y DAI son siempre superiores en hombres. El AUC de la curva ROC para VAI fue alta con METS-VF: en mujeres 0,836 (intervalo de confianza del 95% [IC 95%] 0,829-0,843), en hombres 0,848 (IC 95% 0,845-0,850) y con perímetro de cintura en hombres: 0,819 (IC 95% 0,816-0,822). DAI fue alto para METS-VF en mujeres: 0,809 (IC 95% 0,801-0,817). Conclusiones La prevalencia de obesidad y riesgo relacionado difiere según el método de valoración utilizado. VAI muestra alta fortaleza asociativa en obesidad y masa grasa para METS-VF en ambos sexos y con perímetro de cintura en hombres; DAI para METS-VF en mujeres (AU)


Introduction Obesity is a global pandemic with a growing impact on morbidity and mortality. We assessed the associative strength of the Visceral Adiposity Index (VAI) and Dysfunctional Adiposity Index (DAI) in obesity and associated risk using different methods. Material and methods Cross-sectional study in 418 343 workers from different autonomous communities in Spain, estimating prevalence of obesity with: waist circumference, waist/height index, BMI, CUN-BAE, ECORE-BF, RFM, PALAFOLLS, IMG, METS-VF calculated according to their specific formulas. Descriptive analysis of categorical variables and associative strength of VAI and DAI for obesity was performed with ROC curves considering high risk when the AUC value.0.8 and moderate with AUC.0.7 and.0.8. SPSS 27.0 was used, considering statistical significance p.0.05. Results The prevalence of obesity varied according to the method used, being high with Palafolls (72.92% in women and 86.98% in men) and low with METS-VF (1.31% in women and 8.54% in men). The mean values of VAI and DAI are always higher in men. The AUC of the ROC curve for VAI was high with METS-VF: in women 0.836 (95%CI 0.829-0.843), in men 0.848 (95%CI 0.845-0.850) and with waist circumference in men: 0.819 (95%CI 0.816-0.822). DAI was high for METS-FV in women: 0.809 (95%CI 0.801-0.817). Conclusions The prevalence of obesity and related risk differs according to the assessment method used. VAI shows high strength of association with obesity and fat mass for METS-VF in both sexes and with waist circumference in men; DAI for METS-VF in women (AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Adiposity , Abdominal Fat , Obesity/diagnosis , Obesity/epidemiology , Cross-Sectional Studies , Body Composition , Electric Impedance , Spain/epidemiology
3.
Tech Coloproctol ; 27(10): 929-935, 2023 10.
Article in English | MEDLINE | ID: mdl-37597082

ABSTRACT

PURPOSE: The aim of this study was to evaluate the 5-year recurrence rate of pilonidal sinus disease (PSD) after endoscopic sinusectomy and identify risk factors for recurrence. METHODS: All consecutive patients from September 2011 through December 2017 who underwent endoscopic sinusectomy at seven referral centres for pilonidal sinus treatment were retrospectively analysed from a prospectively maintained database. RESULTS: Out of 290 patients (185 males versus 105 female, with a mean age of 25.5±6.9), 73 presented recurrence at 5-year follow-up with a recurrence rate of 25.2%. The number of pilonidal sinus with pits off the midline (p = 0.001) and the mean (SD) distance from the most lateral orifice to the midline (p = 0.001) were higher in the group of patients with recurrence at 5-year follow-up. Multivariate analysis demonstrated that the position of the pits off the midline (p = 0.001) and the distance of the most lateral orifice from the midline (p = 0.001) were independent risk factors for recurrence at 5-year follow-up. Receiver operating characteristic (ROC) curve analysis showed that the distance of lateral orifice from midline predicted an 82.2% possibility of recurrence at 5-year follow-up and Youden's test identified the best cut-off as 2 cm for this variable. Out of 195 cases with the most lateral orifice less than 2 cm from the midline, 13 presented recurrence at 5-year follow-up with a recurrence rate of 6.7%. Out of 95 cases with the most lateral orifice more than 2 cm from midline, 60 showed recurrence at 5-year follow-up with a recurrence rate of 63.2%. CONCLUSIONS: This data may help guide which disease characteristics predict the optimal use of an endoscopic pilonidal sinus technique.


Subject(s)
Pilonidal Sinus , Skin Diseases , Male , Humans , Female , Adolescent , Young Adult , Adult , Pilonidal Sinus/surgery , Retrospective Studies , Databases, Factual , Multivariate Analysis
4.
EJVES Vasc Forum ; 59: 24-30, 2023.
Article in English | MEDLINE | ID: mdl-37389371

ABSTRACT

Objective: Fiber Optic RealShape (FORS) is a new technology that visualises the full three dimensional (3D) shape of guidewires using an optical fibre embedded in the device. Co-registering FORS guidewires with anatomical images, such as a digital subtraction angiography (DSA), provides anatomical context for navigating these devices during endovascular procedures. The objective of this study was to demonstrate the feasibility and usability of visualising compatible conventional navigation catheters, together with the FORS guidewire, in phantom with a new 3D Hub technology and to understand potential clinical benefits. Methods: The accuracy of localising the 3D Hub and catheter in relation to the FORS guidewire, was evaluated using a translation stage test setup and a retrospective analysis of prior clinical data. Catheter visualisation accuracy and navigation success was assessed in a phantom study where 15 interventionists navigated devices to three pre-defined targets in an abdominal aortic phantom using an Xray or computed tomography angiography (CTA) roadmap. Additionally, the interventionists were surveyed about the usability and potential benefits of the 3D Hub. Results: The location of the 3D Hub and catheter along the FORS guidewire was detected correctly 96.59% of the time. During the phantom study, all 15 interventionists successfully reached the target locations 100% of the time and the error in catheter visualisation was 0.69 mm. The interventionists agreed or strongly agreed that the 3D Hub was easy to use and the greatest potential clinical benefit over FORS is in offering interventionists choice over which catheter they used. Conclusion: This set of studies has shown that FORS guided catheter visualisation, enabled by a 3D Hub, is accurate and easy to use in a phantom setting. Further evaluation is needed to understand the benefits and limitations of the 3D Hub technology during endovascular procedures.

5.
Ocul Surf ; 29: 314-330, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37295473

ABSTRACT

The chronic use of hypotensive agents eventually leads to ocular surface damage and poor patient compliance during glaucoma management. Thus, new sustained drug delivery systems are needed. This work aimed to develop osmoprotective latanoprost-loaded microemulsion formulations as new potential glaucoma treatments with ocular surface protective properties. The microemulsions were characterized and latanoprost encapsulation efficacy determined. In-vitro tolerance, osmoprotective efficacy, cell internalization as well as cell-microemulsion interactions and distribution were performed. In vivo hypotensive activity was conducted in rabbits to assess intraocular pressure reduction and relative ocular bioavailability. Physicochemical characterization showed nanodroplet sizes within 20-30 nm, being in vitro tolerance within 80 and 100% viability in corneal and conjunctival cells. Besides, microemulsions exhibited higher protection under hypertonic conditions than untreated cells. Cell fluorescence lasted for 11 days after short exposure to coumarin-loaded microemulsions (5 min) showing extensive internalization in different cell compartments by electronic microscopy. In vivo studies exhibited that a single instillation of latanoprost-loaded microemulsions reduced the intraocular pressure for several days (4-6 days without polymer and 9-13 days with polymers). Relative ocular bioavailability was 4.5 and 19 times higher than the marketed formulation. These findings suggest the use of these microemulsions as potential combined strategies for extended surface protection and glaucoma treatment.

6.
Semergen ; 49(6): 101965, 2023 Sep.
Article in Spanish | MEDLINE | ID: mdl-37075595

ABSTRACT

INTRODUCTION: Obesity is a global pandemic with a growing impact on morbidity and mortality. We assessed the associative strength of the Visceral Adiposity Index (VAI) and Dysfunctional Adiposity Index (DAI) in obesity and associated risk using different methods. MATERIAL AND METHODS: Cross-sectional study in 418 343 workers from different autonomous communities in Spain, estimating prevalence of obesity with: waist circumference, waist/height index, BMI, CUN-BAE, ECORE-BF, RFM, PALAFOLLS, IMG, METS-VF calculated according to their specific formulas. Descriptive analysis of categorical variables and associative strength of VAI and DAI for obesity was performed with ROC curves considering high risk when the AUC value.0.8 and moderate with AUC.0.7 and.0.8. SPSS 27.0 was used, considering statistical significance p.0.05. RESULTS: The prevalence of obesity varied according to the method used, being high with Palafolls (72.92% in women and 86.98% in men) and low with METS-VF (1.31% in women and 8.54% in men). The mean values of VAI and DAI are always higher in men. The AUC of the ROC curve for VAI was high with METS-VF: in women 0.836 (95%CI 0.829-0.843), in men 0.848 (95%CI 0.845-0.850) and with waist circumference in men: 0.819 (95%CI 0.816-0.822). DAI was high for METS-FV in women: 0.809 (95%CI 0.801-0.817). CONCLUSIONS: The prevalence of obesity and related risk differs according to the assessment method used. VAI shows high strength of association with obesity and fat mass for METS-VF in both sexes and with waist circumference in men; DAI for METS-VF in women.


Subject(s)
Adiposity , Metabolic Syndrome , Male , Humans , Female , Metabolic Syndrome/complications , Metabolic Syndrome/epidemiology , Cross-Sectional Studies , Body Mass Index , Obesity/complications , Obesity/epidemiology , Obesity, Abdominal/epidemiology , Waist Circumference
7.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 67(2): 125-133, Mar-Abr. 2023. ilus, tab, graf
Article in Spanish | IBECS | ID: ibc-217110

ABSTRACT

Objetivo: Comprobar si la aplicación de fijación externa mediante barra curva conectada a clavos de Schanz supraacetabulares confiere mayor estabilidad al anillo pélvico con una lesión tipo Tile C1 cuando se realiza el montaje con la barra pretensada que con el montaje estándar (sin pretensar). Material y métodos: Pelvis sintéticas (N=5) con lesión verticalmente inestable estabilizada con ambos montajes, se sometieron a carga axial progresiva. Se midieron las fuerzas aplicadas y las variaciones en las posiciones de marcadores situados en la articulación sacroilíaca y la sínfisis se registraron con un sistema óptico. Se determinaron los desplazamientos relativos entre las superficies lesionadas, la rigidez, la resistencia y el modo de fallo de cada montaje. Resultados: Con el fijador pretensado, la rigidez del montaje en la articulación sacroilíaca resultó muy superior a la del montaje convencional (p=0,043) multiplicándola por 3,45, siendo 2,06 veces mayor en la sínfisis. La resistencia ante el fallo también fue superior, multiplicándola por 2 (p=0,043). Discusión: El aumento de estabilidad a carga axial con el fijador externo pretensado concuerda con su capacidad de producir compresión activa simultánea en los elementos posteriores y anteriores del anillo pélvico, demostrada previamente. Este resultado soporta los excelentes resultados clínicos preliminares obtenidos como tratamiento provisional. Conclusiones: El fijador externo pretensado aumenta la estabilidad axial de los elementos óseos posteriores del anillo pélvico con lesión tipo Tile C1 en modelo sintético, sin disminuir la capacidad de estabilización anterior propia de la fijación externa anterior.(AU)


Objective: The aim of our work is to check if the use of a pre-tensed bar connected to 2supra-acetabular Schanz pins is more stable in a pelvic with a tile C1 injury. Material and methods: We used synthetic pelvis (N=5) with a unstable vertical injury, stabilized with both the standard and the pre-tensed system. They both were submitted to axial loading. We measured applied forces and the position of markers that were positioned in the sacroiliac and symphysis joints. We determined the relative movements between injured surfaces, rigidity, resistance and when each system failed. Results: When using the pre-tensed fixator, the rigidity was much higher in the sacro-iliac joint (P=.043) being 3.45 times higher, being also 2.06 times higher in pubic symphysis (P=.043). The resistance against failure was 2 times higher too (P=.043). Discussion: The increased axial stability with the pre-tensed external fixator accords with its ability to make active compression in both posterior and anterior elements of the pelvic ring, which was previously demonstrated. This result supports the preliminary clinic outcomes that were obtained. Conclusions: The pre-tensed external fixator increases the axial stability of the pelvic ring's posterior elements in a synthethic pelvis with a Tile C1 injury, without decreasing it's capacity to achieve an anterior stability.(AU)


Subject(s)
Humans , Weight-Bearing , Biomechanical Phenomena , Pelvis/surgery , External Fixators , Fractures, Bone , Fracture Fixation , Traumatology , Orthopedics
8.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 67(2): T125-T133, Mar-Abr. 2023. ilus, tab, graf
Article in English | IBECS | ID: ibc-217111

ABSTRACT

Objetivo: Comprobar si la aplicación de fijación externa mediante barra curva conectada a clavos de Schanz supraacetabulares confiere mayor estabilidad al anillo pélvico con una lesión tipo Tile C1 cuando se realiza el montaje con la barra pretensada que con el montaje estándar (sin pretensar). Material y métodos: Pelvis sintéticas (N=5) con lesión verticalmente inestable estabilizada con ambos montajes, se sometieron a carga axial progresiva. Se midieron las fuerzas aplicadas y las variaciones en las posiciones de marcadores situados en la articulación sacroilíaca y la sínfisis se registraron con un sistema óptico. Se determinaron los desplazamientos relativos entre las superficies lesionadas, la rigidez, la resistencia y el modo de fallo de cada montaje. Resultados: Con el fijador pretensado, la rigidez del montaje en la articulación sacroilíaca resultó muy superior a la del montaje convencional (p=0,043) multiplicándola por 3,45, siendo 2,06 veces mayor en la sínfisis. La resistencia ante el fallo también fue superior, multiplicándola por 2 (p=0,043). Discusión: El aumento de estabilidad a carga axial con el fijador externo pretensado concuerda con su capacidad de producir compresión activa simultánea en los elementos posteriores y anteriores del anillo pélvico, demostrada previamente. Este resultado soporta los excelentes resultados clínicos preliminares obtenidos como tratamiento provisional. Conclusiones: El fijador externo pretensado aumenta la estabilidad axial de los elementos óseos posteriores del anillo pélvico con lesión tipo Tile C1 en modelo sintético, sin disminuir la capacidad de estabilización anterior propia de la fijación externa anterior.(AU)


Objective: The aim of our work is to check if the use of a pre-tensed bar connected to 2supra-acetabular Schanz pins is more stable in a pelvic with a tile C1 injury. Material and methods: We used synthetic pelvis (N=5) with a unstable vertical injury, stabilized with both the standard and the pre-tensed system. They both were submitted to axial loading. We measured applied forces and the position of markers that were positioned in the sacroiliac and symphysis joints. We determined the relative movements between injured surfaces, rigidity, resistance and when each system failed. Results: When using the pre-tensed fixator, the rigidity was much higher in the sacro-iliac joint (P=.043) being 3.45 times higher, being also 2.06 times higher in pubic symphysis (P=.043). The resistance against failure was 2 times higher too (P=.043). Discussion: The increased axial stability with the pre-tensed external fixator accords with its ability to make active compression in both posterior and anterior elements of the pelvic ring, which was previously demonstrated. This result supports the preliminary clinic outcomes that were obtained. Conclusions: The pre-tensed external fixator increases the axial stability of the pelvic ring's posterior elements in a synthethic pelvis with a Tile C1 injury, without decreasing it's capacity to achieve an anterior stability.(AU)


Subject(s)
Humans , Weight-Bearing , Biomechanical Phenomena , Pelvis/surgery , External Fixators , Fractures, Bone , Fracture Fixation , Traumatology , Orthopedics
11.
Rev Esp Cir Ortop Traumatol ; 67(2): 125-133, 2023.
Article in English, Spanish | MEDLINE | ID: mdl-35985409

ABSTRACT

OBJECTIVE: The aim of our work is to check if the use of a pre-tensed bar connected to 2supra-acetabular Schanz pins is more stable in a pelvic with a tile C1 injury. MATERIAL AND METHODS: We used synthetic pelvis (N=5) with a unstable vertical injury, stabilized with both the standard and the pre-tensed system. They both were submitted to axial loading. We measured applied forces and the position of markers that were positioned in the sacroiliac and symphysis joints. We determined the relative movements between injured surfaces, rigidity, resistance and when each system failed. RESULTS: When using the pre-tensed fixator, the rigidity was much higher in the sacro-iliac joint (P=.043) being 3.45 times higher, being also 2.06 times higher in pubic symphysis (P=.043). The resistance against failure was 2 times higher too (P=.043). DISCUSSION: The increased axial stability with the pre-tensed external fixator accords with its ability to make active compression in both posterior and anterior elements of the pelvic ring, which was previously demonstrated. This result supports the preliminary clinic outcomes that were obtained. CONCLUSIONS: The pre-tensed external fixator increases the axial stability of the pelvic ring's posterior elements in a synthethic pelvis with a Tile C1 injury, without decreasing it's capacity to achieve an anterior stability.


Subject(s)
Fractures, Bone , Pelvic Bones , Humans , Fracture Fixation , Pelvic Bones/injuries , Pelvic Bones/surgery , External Fixators , Pelvis/injuries , Pelvis/surgery , Bone Nails , Biomechanical Phenomena
12.
Rev Esp Cir Ortop Traumatol ; 67(2): T125-T133, 2023.
Article in English, Spanish | MEDLINE | ID: mdl-36528300

ABSTRACT

OBJECTIVE: The aim of our work is to check if the use of a pre-tensed bar connected to 2 supra-acetabular Schanz pins is more stable in a pelvic with a tile C1 injury. MATERIAL AND METHODS: We used synthetic pelvis (N = 5) with a unstable vertical injury, stabilized with both the standard and the pre-tensed system. They both were submitted to axial loading. We measured applied forces and the position of markers that were positioned in the sacroiliac and symphysis joints. We determined the relative movements between injured surfaces, rigidity, resistance and when each system failed. RESULTS: When using the pre-tensed fixator, the rigidity was much higher in the sacro-iliac joint(P=.043) being 3.45 times higher, being also 2.06 times higher in pubic symphysis (P=.043). The resistance against failure was 2 times higher too (P=.043). DISCUSSION: The increased axial stability with the pre-tensed external fixator accords with its ability to make active compression in both posterior and anterior elements of the pelvic ring, which was previously demonstrated. This result supports the preliminary clinic outcomes that were obtained. CONCLUSIONS: The pre-tensed external fixator increases the axial stability of the pelvic ring's posterior elements in a synthethic pelvis with a Tile C1 injury, without decreasing it's capacity to achieve an anterior stability.


Subject(s)
Fractures, Bone , Pelvic Bones , Humans , Fracture Fixation , Pelvic Bones/injuries , Pelvic Bones/surgery , External Fixators , Pelvis/injuries , Pelvis/surgery , Bone Nails , Biomechanical Phenomena
15.
J Prof Nurs ; 43: 152-161, 2022.
Article in English | MEDLINE | ID: mdl-36496239

ABSTRACT

BACKGROUND: Leadership competence is important to ensure the provision of safe and high-quality care in hospitals. PURPOSE: The aim was to demonstrate the feasibility of enhancing the perceived leadership competence of nursing students through an innovative health education strategy, consisting of a student-led dedicated education unit (DEU) informed by a service-learning approach in a community setting. DESIGN: Feasibility study in a three-phase process: I: Design; II: Acceptability and implementation; III: Expansion to a different setting. In phase II the DEU was piloted with 62 students using a pretest/post-test with control group design. In phase III it was piloted with 20 students in the expansion setting. METHODS: The DEU was implemented and tested in Barcelona (Spain) between 2014 and 2019. To assess acceptability and implementation, students' perceived leadership competence was measured using the Self-Assessment Leadership Instrument. We also obtained satisfaction ratings using an ad hoc questionnaire. RESULTS: Satisfaction was high among students, as well as among service users who received health education. In phase II, students' post-test self-ratings of their leadership competence were higher in both the intervention and control groups, but the increase was significantly greater among students who participated in the DEU (25.84 % vs. 16.72 %, p = .012). Similar results were obtained in the expansion phase, with students in the intervention group once again showing a significant increase in perceived leadership skills (12.89 %, p = .005). CONCLUSIONS: Student-led DEUs appear to be an effective way of enhancing perceived leadership competence among senior nursing students.


Subject(s)
Education, Nursing, Baccalaureate , Students, Nursing , Humans , Education, Nursing, Baccalaureate/methods , Feasibility Studies , Leadership , Learning
16.
Pediatr Surg Int ; 38(10): 1445-1451, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35852592

ABSTRACT

AIM: Ectopic breast tissue (EBT) includes a spectrum of disease that entails other entities based on the presence of glandular tissue, nipple, or areola. The diagnosis in adolescents is infrequent. METHODS: A retrospective study was performed including girls with axillary EBT (class IV or V of Kajava's Classification) operated in 2006-2020. Imagining studies, clinical and surgical reports, and histopathology were reviewed. RESULTS: Eleven girls from 13 to 16 years old were included. Two patients (18.2%) presented bilateral EBT. The most frequent clinical manifestation was 2-5 cm mass (100%), associating cyclic pain with menstruation (45%) and fluctuating volume (36%). Bilateral axillary ultrasonography allowed preoperative diagnosis. All of them were treated by open excision, through small incisions located in an axillary y fold. Clinical and aesthetic results were self-assessed as "very good", with normalization of the axillary y hollow and imperceptible scars. No recurrences were observed after one year of follow-up. An immediate postoperative hematoma was reported, which did not require drainage. Histopathology showed mature breast tissue without atypia. CONCLUSIONS: Axillary accessory breasts must be included in differential diagnosis of pediatric axillary masses. Bilateral ultrasonography is recommended for the preoperative diagnosis. Excision through minimal incision at this age seems to be safe and effective.


Subject(s)
Breast Neoplasms , Choristoma , Adolescent , Axilla/pathology , Axilla/surgery , Breast/diagnostic imaging , Breast/pathology , Breast/surgery , Child , Choristoma/diagnostic imaging , Choristoma/surgery , Cicatrix , Female , Humans , Nipples/pathology , Nipples/surgery , Retrospective Studies
17.
Int J Pharm ; 623: 121948, 2022 Jul 25.
Article in English | MEDLINE | ID: mdl-35752388

ABSTRACT

Self-emulsified osmoprotective ophthalmic microemulsions (O/A) were prepared by combining betaine/leucine, clusterin/oleanolic acid, and hyaluronic acid or Dextran. The microemulsions contained an internal oily phase (1.2%), an external aqueous phase (96.3%), cosolvents (1%), and surfactants (1.5%). Physicochemical characterization and in vivo and in vitro tolerance were analyzed. The formulations' osmoprotective in vitro activity was assayed in a hyperosmolar model in human corneal cells. Average internal phase sizes were 16-26 nm for the microemulsions including Dextran. Addition of hyaluronic acid increased the size range (25-39 nm). Addition of osmoprotectants did not change nanodroplet size. The formulations were isotonic (280-290 mOsm/L) with neutral pH (≈7) and zeta potential (-10 to 0 mV), low surface tension (≈35-40mN·m-1), and low viscosity (≈1 mPa·s), except for the microemulsions containing hyaluronic acid (≈4-5 mPa·s). SEM and cryo-TEM showed that all formulations exhibited sphere-shaped morphology with good cell tolerance (≈100%) and were stable at 8 °C for 9 months. Osmoprotective formulations were well tolerated in vitro and in vivo, protecting cells from hypertonic stress. We therefore developed stable microemulsions compatible with the ocular surface that could constitute a novel tool for treatment of ophthalmic diseases.


Subject(s)
Dextrans , Hyaluronic Acid , Emulsions/chemistry , Eye , Humans , Surface-Active Agents/chemistry
18.
J Geophys Res Planets ; 127(12): e2022JE007523, 2022 Dec.
Article in English | MEDLINE | ID: mdl-37033152

ABSTRACT

Wind speeds measured by the Mars 2020 Perseverance rover in Jezero crater were fitted as a Weibull distribution. InSight wind data acquired in Elysium Planitia were also used to contextualize observations. Jezero winds were found to be much calmer on average than in previous landing sites, despite the intense aeolian activity observed. However, a great influence of turbulence and wave activity was observed in the wind speed variations, thus driving the probability of reaching the highest wind speeds at Jezero, instead of sustained winds driven by local, regional, or large-scale circulation. The power spectral density of wind speed fluctuations follows a power-law, whose slope deviates depending on the time of day from that predicted considering homogeneous and isotropic turbulence. Daytime wave activity is related to convection cells and smaller eddies in the boundary layer, advected over the crater. The signature of convection cells was also found during dust storm conditions, when prevailing winds were consistent with a tidal drive. Nighttime fluctuations were also intense, suggesting strong mechanical turbulence. Convective vortices were usually involved in rapid wind fluctuations and extreme winds, with variations peaking at 9.2 times the background winds. Transient high wind events by vortex-passages, turbulence, and wave activity could be driving aeolian activity at Jezero. We report the detection of a strong dust cloud of 0.75-1.5 km in length passing over the rover. The observed aeolian activity had major implications for instrumentation, with the wind sensor suffering damage throughout the mission, probably due to flying debris advected by winds.

20.
J Small Anim Pract ; 63(4): 286-292, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34897695

ABSTRACT

OBJECTIVE: To determine the effect of urine-specific gravity (USG) on using microscopic evaluation of bacteriuria to predict urine culture results in dogs and cats. MATERIALS AND METHODS: We performed a retrospective medical record review of canine and feline patients that had a urinalysis and urine culture performed simultaneously. The sensitivity, specificity, positive predictive value and negative predictive value of microscopic bacteriuria for predicting urine culture results were calculated, stratified by USG. Multivariable regression was performed to test the effect of USG, pyuria, haematuria and species on the agreement between microscopic bacteriuria and culture results. RESULTS: A total of 481 dogs and 291 cats with paired urinalysis and urine culture results were included in the study. Microscopic bacteriuria had moderate sensitivity (76% in dogs, 64% in cats) and high specificity (97% in dogs, 96% in cats) for predicting urine culture bacterial growth. Samples with rod bacteria were more likely to have bacterial growth than those with cocci (OR=Infinity, 95% CI 4.8 - Infinity). As compared to isosthenuric+hyposthenuric samples (USG ≤1.012), agreement was lower in moderately concentrated (OR=0.44, 95% CI 0.19 to 0.91) samples. Absence of bacteriuria, pyuria and haematuria had a high negative predictive value for no bacterial growth (96%). CLINICAL SIGNIFICANCE: Microscopic bacteriuria has a high specificity in predicting urine culture results, regardless of USG. The finding that microscopic bacteriuria has better agreement with urine culture results in isosthenuric+hyposthenuric urine argues against reflex culture in these samples, especially if pyuria and haematuria are also absent. Urine microscopy can aid clinicians in determining the likelihood of urine culture growth.


Subject(s)
Bacteriuria , Cat Diseases , Dog Diseases , Pyuria , Urinary Tract Infections , Animals , Bacteriuria/diagnosis , Bacteriuria/microbiology , Bacteriuria/veterinary , Cat Diseases/diagnosis , Cat Diseases/microbiology , Cats , Dog Diseases/diagnosis , Dog Diseases/urine , Dogs , Female , Hematuria/diagnosis , Hematuria/veterinary , Male , Microscopy/veterinary , Pyuria/diagnosis , Pyuria/veterinary , Retrospective Studies , Specific Gravity , Urinalysis/methods , Urinalysis/veterinary , Urinary Tract Infections/veterinary , Urine
SELECTION OF CITATIONS
SEARCH DETAIL
...