Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Int J Cardiovasc Imaging ; 33(11): 1731-1736, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28550586

ABSTRACT

The diffusion of smart-phones offers access to the best remote expertise in stress echo (SE). To evaluate the reliability of SE based on smart-phone filming and reading. A set of 20 SE video-clips were read in random sequence with a multiple choice six-answer test by ten readers from five different countries (Italy, Brazil, Serbia, Bulgaria, Russia) of the "SE2020" study network. The gold standard to assess accuracy was a core-lab expert reader in agreement with angiographic verification (0 = wrong, 1 = right). The same set of 20 SE studies were read, in random order and >2 months apart, on desktop Workstation and via smartphones by ten remote readers. Image quality was graded from 1 = poor but readable, to 3 = excellent. Kappa (k) statistics was used to assess intra- and inter-observer agreement. The image quality was comparable in desktop workstation vs. smartphone (2.0 ± 0.5 vs. 2.4 ± 0.7, p = NS). The average reading time per case was similar for desktop versus smartphone (90 ± 39 vs. 82 ± 54 s, p = NS). The overall diagnostic accuracy of the ten readers was similar for desktop workstation vs. smartphone (84 vs. 91%, p = NS). Intra-observer agreement (desktop vs. smartphone) was good (k = 0.81 ± 0.14). Inter-observer agreement was good and similar via desktop or smartphone (k = 0.69 vs. k = 0.72, p = NS). The diagnostic accuracy and consistency of SE reading among certified readers was high and similar via desktop workstation or via smartphone.


Subject(s)
Echocardiography, Stress/instrumentation , Mobile Applications , Myocardial Ischemia/diagnostic imaging , Remote Consultation/instrumentation , Smartphone , Brazil , Coronary Angiography , Europe , Feasibility Studies , Humans , Myocardial Ischemia/physiopathology , Observer Variation , Predictive Value of Tests , Prognosis , Prospective Studies , Reproducibility of Results
2.
Cardiovasc Ultrasound ; 6: 56, 2008 Nov 16.
Article in English | MEDLINE | ID: mdl-19014611

ABSTRACT

Multiparametric echocardiographic imaging of the failing heart is now increasingly used and useful in decision making in heart failure. The reasons for this, relies on the need of different strategies of handling these patients, as differentiation of systolic or diastolic dysfunction, as well as on the gamma of approaches available, such as percutaneous and surgical revascularization, devices implantations, and valvular regurgitations and stenosis corrections. Congestive heart failure in patients with normal left ventricular diameters or preserved left ventricular ejection fraction had been pointed out recently as present in a proportion so high as 40 to 50 percent of cases of heart failure, mainly due to the epidemics in well developed countries, as is the problem of not well controlled metabolic states (such as obesity and diabetes), but also due to the real word in developing countries, as is the case of hypertension epidemics and its lack of adequate control. As a matter of public utility, the guidelines in the diagnosis and treatment of such patients will have to be cheap, available, easily reproducible, and ideally will furnish answers for the clinician questions not in a binary "black or white" manner, but with graduations, so if possible it has to be quantitative. The present paper aim to focus on the current clinical applications of tissue Doppler and of left atrial function and remodeling, and its pathophysiologic relationship with the left ventricle, as will be cleared in the documented review of echocardiography that follows, considering that the need of universal data on the syndrome of the failing heart does not mean, unfortunately, that all patients and clinicians in developing countries have at their own health facilities the same imaging tools, since they are, as a general rule, expensive.


Subject(s)
Echocardiography/methods , Heart Failure/complications , Heart Failure/diagnostic imaging , Stroke Volume , Ventricular Dysfunction, Left/complications , Ventricular Dysfunction, Left/diagnostic imaging , Humans , Ventricular Remodeling
3.
Am J Nephrol ; 26(5): 469-75, 2006.
Article in English | MEDLINE | ID: mdl-17085934

ABSTRACT

OBJECTIVE: Tissue Doppler imaging (TDI) has recently been proposed as a relatively preload-independent method to evaluate left ventricular diastolic function. We sought to investigate the higher-accuracy of TDI to assess diastolic function in end-stage renal disease (ESRD) patients on hemodialysis (HD) associated with a preload increase maneuver. METHODS: Thirty-two consecutiveESRD patients (16 female, ages 48.8 +/- 17.5 years, 14 45 years old) were evaluated. Measurements of E, A velocities and the E/A ratio from transmitral inflow pulsed wave Doppler, and E', A' velocities and the E'/A' ratio from TDI were obtained 1 h before and 1 h after HD at baseline and with a preload increase maneuver. RESULTS: The E/A ratio changed significantly in all patients aged >45 before and after HD with the preload increase maneuver. The E'/A' ratio increased in all subjects with the preload increase maneuver before HD but did not change with the maneuver after HD in the euvolemic state in all patients. CONCLUSION: In ESRD patients on routine HD, TDI evaluation associated with a preload increase maneuver proved to be a more accurate method to identify diastolic dysfunction when the evaluation is performed in euvolemic patients after HD.


Subject(s)
Diastole , Echocardiography, Doppler , Kidney Failure, Chronic/physiopathology , Kidney Failure, Chronic/therapy , Renal Dialysis , Ventricular Dysfunction, Left/physiopathology , Ventricular Function, Left , Diastole/physiology , Female , Humans , Kidney Failure, Chronic/diagnostic imaging , Male , Middle Aged , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Function, Left/physiology
4.
Clin Chem Lab Med ; 41(10): 1351-6, 2003 Oct.
Article in English | MEDLINE | ID: mdl-14580165

ABSTRACT

Lipoprotein lipase is the rate-limiting enzyme in the lipolysis of plasma triglyceride-rich lipoproteins. We studied six variants (T-93G, D9N, N291S, PvuII, HindIII and S447X) in the lipoprotein lipase (LPL) gene in 309 non-diabetic patients with angiographically assessed coronary artery disease and in 197 controls in a southern Brazilian population of European descent. The HindIII H-allele was associated with lower triglycerides (p < 0.01) and higher high-density lipoprotein cholesterol (p = 0.03) levels, and the S447X mutation was associated with lower triglyceride levels (p < 0.01) in males, but not females. No other significant lipid associations were observed. Haplotypes were derived from these two sites (HindIII/S447X), and carriers of H-S and H-X haplotypes showed lower triglycerides (p < 0.01) and increased high-density lipoprotein cholesterol (p = 0.01) levels when compared to the H+S haplotype in males. In this gender, the H-X haplotype was associated with a protective effect (OR = 0.36, 95%CI = 0.13-0.97) for significant disease (> or = 60% of luminal coronary stenosis), even controlling for other classical risk factors.


Subject(s)
Coronary Angiography , Coronary Artery Disease/genetics , Lipid Metabolism , Lipoprotein Lipase/genetics , Aged , Brazil , Coronary Artery Disease/diagnostic imaging , Female , Genetics, Population , Genotype , Humans , Linkage Disequilibrium , Lipoprotein Lipase/metabolism , Male , Middle Aged , Mutation , Polymorphism, Single Nucleotide
5.
Am J Cardiol ; 90(3): 238-42, 2002 Aug 01.
Article in English | MEDLINE | ID: mdl-12127610

ABSTRACT

The risk of cardiac events in patients undergoing major noncardiac surgery is dependent on their clinical characteristics and the results of stress testing. The purpose of this study was to develop a composite approach to defining levels of risk and to examine whether different approaches to prophylaxis influenced this prediction of outcome. One hundred forty-five consecutive patients (aged 68 +/- 9 years, 79 men) with >1 clinical risk variable were studied with standard dobutamine-atropine stress echo before major noncardiac surgery. Risk levels were stratified according to the presence of ischemia (new or worsening wall motion abnormality), ischemic threshold (heart rate at development of ischemia), and number of clinical risk variables. Patients were followed for perioperative events (during hospital admission) and death or infarction over the subsequent 16 +/- 10 months. Ten perioperative events occurred in 105 patients who proceeded to surgery (10%, 95% confidence interval [CI] 5% to 17%), 40 being cancelled because of cardiac or other risk. No ischemia was identified in 56 patients, 1 of whom (1.8%) had a perioperative infarction. Of the 49 patients with ischemia, 22 (45%) had 1 or 2 clinical risk factors; 2 (9%, 95% CI 1% to 29%) had events. Another 15 patients had a high ischemic threshold and 3 or 4 risk factors; 3 (20%, 95% CI 4% to 48%) had events. Twelve patients had a low ischemic threshold and 3 or 4 risk factors; 4 (33%, 95% CI 10% to 65%) had events. Preoperative myocardial revascularization was performed in only 3 patients, none of whom had events. Perioperative and long-term events occurred despite the use of beta blockers; 7 of 41 beta blocker-treated patients had a perioperative event (17%, 95% CI 7% to 32%); these treated patients were at higher anticipated risk than untreated patients (20 +/- 24% vs 10 +/- 19%, p = 0.02). The total event rate over late follow-up was 13%, and was predicted by dobutamine-atropine stress echo results and heart rate response.


Subject(s)
Myocardial Ischemia/diagnosis , Aged , Atropine , Dobutamine , Echocardiography , Electrocardiography , Exercise Test , Female , Follow-Up Studies , Humans , Male , Myocardial Ischemia/complications , Myocardial Revascularization , Prognosis , Risk Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...