Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chim Acta ; 1288: 342159, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38220291

ABSTRACT

BACKGROUND: Biomedical diagnostic and lab automation solutions built on the Lab-on-a-Disc (LoaD) platform has great potential due to their independence from specialised micro-pumps and their ease of integration, through direct pipetting, with manual or automated workflows. However, a challenge for all microfluidic chips is their cost of manufacture when each microfluidic disc must be customized for a specific application. In this paper, we present centrifugal discs with programmable fluidic networks. RESULTS: Based on dissolvable film valves, we present two technologies. The first, based on recently introduced pulse-actuated dissolvable film valves, is a centrifugal disc which, depending on how it is loaded, is configured to perform either six sequential reagent releases through one reaction chamber or three sequential reagent releases through two reaction chambers. In the second approach, we use the previously introduced electronic Lab-on-a-Disc (eLoaD) wireless valve array, which can actuate up to 128 centrifugo-pneumatic dissolvable film valves in a pre-defined sequence. In this approach we present a disc which can deliver any one of 8 reagent washes to any one of four reaction chambers. We use identical discs to demonstrate the first four sequential washes through two reaction chambers and then two sequential washes through four reaction chambers. SIGNIFICANCE: These programmable fluidic networks have the potential to allow a single disc architecture to be applied to multiple different assay types and so can offer a lower-cost and more integrated alternative to the standard combination of micro-titre plate and liquid handling robot. Indeed, it may even be possible to conduct multiple different assays concurrently. This can have the effect of reducing manufacturing costs and streamlining supply-chains and so results in a more accessible diagnostic platform.

2.
Biosensors (Basel) ; 11(3)2021 Mar 06.
Article in English | MEDLINE | ID: mdl-33800811

ABSTRACT

Within microfluidic technologies, the centrifugal microfluidic "Lab-on-a-Disc" (LoaD) platform offers great potential for use at the PoC and in low-resource settings due to its robustness and the ability to port and miniaturize 'wet bench' laboratory protocols. We present the combination of 'event-triggered dissolvable film valves' with a centrifugo-pneumatic siphon structure to enable control and timing, through changes in disc spin-speed, of the release and incubations of eight samples/reagents/wash buffers. Based on these microfluidic techniques, we integrated and automated a chemiluminescent immunoassay for detection of the CVD risk factor marker C-reactive protein displaying a limit of detection (LOD) of 44.87 ng mL-1 and limit of quantitation (LoQ) of 135.87 ng mL-1.


Subject(s)
C-Reactive Protein/analysis , Lab-On-A-Chip Devices , Automation , Biomarkers/analysis , Cardiovascular Diseases/metabolism , Equipment Design , Humans , Laboratories , Limit of Detection , Microfluidic Analytical Techniques , Microfluidics
3.
Magn Reson (Gott) ; 1(1): 105-113, 2020.
Article in English | MEDLINE | ID: mdl-37904886

ABSTRACT

We introduce a low-complexity, low-cost, yet sufficiently accurate automatic tune and match system for NMR and MRI applications. The ArduiTaM builds upon an Arduino Uno embedded system that drives a commercial frequency synthesiser chip to perform a frequency sweep around the Larmor frequency. The generated low-power signal is fed to the NMR coil, after which the reflected waves are detected using a directional coupler and amplified. The signal shape is then extracted by means of an envelope detector and passed on to the Arduino, which performs a dip search while continuously generating actuator control patterns to adjust the tune and match capacitors. The process stops once the signal dip reaches the Larmor frequency. The ArduiTaM works readily with any spectrometer frequency in the range from 1 to 23 T. The speed of the ArduiTaM is mainly limited by the clock of the Arduino and the capacitor actuation mechanism. The Arduino can easily be replaced by a higher-speed microcontroller, and varactors can replace stepper-motor controlled variable capacitors. The ArduiTaM is made available in open source, and so is easily duplicated.

4.
Biosens Bioelectron ; 117: 464-473, 2018 Oct 15.
Article in English | MEDLINE | ID: mdl-29982115

ABSTRACT

In this paper we present a comprehensive description of the design, fabrication and operation of an electrified Lab-on-a-Disc (eLoaD) system. The smart platform is developed to extend conventional Lab-on-a-Disc applications with an electronic interface, providing additional flow control and sensing capabilities to centrifugal microfluidics platforms. Wireless power is transferred from a Qi-compliant transmitter to the eLoaD platform during rotation. An Arduino-based microcontroller, a Bluetooth communication module, and an on-board SD-card are integrated into the platform. This generalises the applicability of the eLoaD and its modules for performing a wide range of laboratory unit operations, procedures, or diagnostic assays, all controlled wirelessly during spinning. The lightweight platform is fully reusable and modular in design and construction. An interchangeable and non-disposable application disc is fitted with the necessary sensors and/or actuators for a specific assay or experiment to be performed. A particular advantage is the ability to continuously monitor and interact with LoaD experiments, overcoming the limitations of stroboscopy. We demonstrate the applicability of the platform for three sensing experiments involving optical, electrochemical, and temperature detection, and one actuation experiment involving controlled heating/cooling. The complete electronic designs and example programming codes are extensively documented in the supplementary material for easy adaptation.


Subject(s)
Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Microfluidic Analytical Techniques/instrumentation , Electrochemistry/instrumentation , Rotation , Temperature
5.
Biosens Bioelectron ; 109: 214-223, 2018 Jun 30.
Article in English | MEDLINE | ID: mdl-29567566

ABSTRACT

In this paper we present a wirelessly powered array of 128 centrifugo-pneumatic valves that can be thermally actuated on demand during spinning. The valves can either be triggered by a predefined protocol, wireless signal transmission via Bluetooth, or in response to a sensor monitoring a parameter like the temperature, or homogeneity of the dispersion. Upon activation of a resistive heater, a low-melting membrane (Parafilm™) is removed to vent an entrapped gas pocket, thus letting the incoming liquid wet an intermediate dissolvable film and thereby open the valve. The proposed system allows up to 12 heaters to be activated in parallel, with a response time below 3 s, potentially resulting in 128 actuated valves in under 30 s. We demonstrate, with three examples of common and standard procedures, how the proposed technology could become a powerful tool for implementing diagnostic assays on Lab-on-a-Disc. First, we implement wireless actuation of 64 valves during rotation in a freely programmable sequence, or upon user input in real time. Then, we show a closed-loop centrifugal flow control sequence for which the state of mixing of reagents, evaluated from stroboscopically recorded images, triggers the opening of the valves. In our last experiment, valving and closed-loop control are used to facilitate centrifugal processing of whole blood.


Subject(s)
Biosensing Techniques , Microfluidic Analytical Techniques/methods , Wireless Technology , Centrifugation , Membranes, Artificial , Pressure , Rotation
6.
Micromachines (Basel) ; 7(2)2016 Jan 29.
Article in English | MEDLINE | ID: mdl-30407395

ABSTRACT

We review the utility of centrifugal microfluidic technologies applied to point-of-care diagnosis in extremely under-resourced environments. The various challenges faced in these settings are showcased, using areas in India and Africa as examples. Measures for the ability of integrated devices to effectively address point-of-care challenges are highlighted, and centrifugal, often termed CD-based microfluidic technologies, technologies are presented as a promising platform to address these challenges. We describe the advantages of centrifugal liquid handling, as well as the ability of a standard CD player to perform a number of common laboratory tests, fulfilling the role of an integrated lab-on-a-CD. Innovative centrifugal approaches for point-of-care in extremely resource-poor settings are highlighted, including sensing and detection strategies, smart power sources and biomimetic inspiration for environmental control. The evolution of centrifugal microfluidics, along with examples of commercial and advanced prototype centrifugal microfluidic systems, is presented, illustrating the success of deployment at the point-of-care. A close fit of emerging centrifugal systems to address a critical panel of tests for under-resourced clinic settings, formulated by medical experts, is demonstrated. This emphasizes the potential of centrifugal microfluidic technologies to be applied effectively to extremely challenging point-of-care scenarios and in playing a role in improving primary care in resource-limited settings across the developing world.

7.
Lab Chip ; 15(12): 2584-7, 2015 Jun 21.
Article in English | MEDLINE | ID: mdl-25968976

ABSTRACT

We present a design for wireless power transfer, via inductively coupled coils, to a spinning disk. The rectified and stabilised power feeds an Arduino-compatible microcontroller (µC) on the disc, which in turn drives and monitors various sensors and actuators. The platform, which has been conceived to flexibly prototype such systems, demonstrates the feasibility of a wireless power supply and the use of a µC circuit, for example for Lab-on-a-disk applications, thereby eliminating the need for cumbersome slip rings or batteries, and adding a cogent and new degree of freedom to the setup. The large number of sensors and actuators included demonstrate that a wide range of physical parameters can be easily monitored and altered. All devices are connected to the µC via an I(2)C bus, therefore can be easily exchanged or augmented by other devices in order to perform a specific task on the disk. The wireless power supply takes up little additional physical space and should work in conjunction with most existing Lab-on-a-disk platforms as a straightforward add-on, since it does not require modification of the rotation axis and can be readily adapted to specific geometrical requirements.

SELECTION OF CITATIONS
SEARCH DETAIL
...