Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
NPJ Parkinsons Dis ; 9(1): 9, 2023 Jan 25.
Article in English | MEDLINE | ID: mdl-36697421

ABSTRACT

Patients with Parkinson's disease often complain of excessive daytime sleepiness which negatively impacts their quality of life. The pedunculopontine nucleus, proposed as a target for deep brain stimulation to improve freezing of gait in Parkinson's disease, is also known to play a key role in the arousal system. Thus, the putative control of excessive daytime sleepiness by pedunculopontine nucleus area stimulation merits exploration for treating Parkinson's disease patients. To this end, two adult nonhuman primates (macaca fascicularis) received a deep brain stimulation electrode implanted into the pedunculopontine nucleus area along with a polysomnographic equipment. Stimulation at low frequencies and high frequencies was studied, in healthy and then MPTP-treated nonhuman primates. Here, we observed that MPTP-treated nonhuman primates suffered from excessive daytime sleepiness and that low-frequency stimulation of the pedunculopontine nucleus area was effective in reducing daytime sleepiness. Indeed, low-frequency stimulation of the pedunculopontine nucleus area induced a significant increase in sleep onset latency, longer continuous periods of wakefulness and thus, a partially restored daytime wake architecture. These findings may contribute to the development of new therapeutic strategies in patients suffering from excessive daytime sleepiness.

2.
Neural Regen Res ; 18(7): 1423-1426, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36571337

ABSTRACT

Epilepsy is synonymous with individuals suffering repeated "fits" or seizures. The seizures are triggered by bursts of abnormal neuronal activity, across either the cerebral cortex and/or the hippocampus. In addition, the seizure sites are characterized by considerable neuronal death. Although the factors that generate this abnormal activity and death are not entirely clear, recent evidence indicates that mitochondrial dysfunction plays a central role. Current treatment options include drug therapy, which aims to suppress the abnormal neuronal activity, or surgical intervention, which involves the removal of the brain region generating the seizure activity. However, ~30% of patients are unresponsive to the drugs, while the surgery option is invasive and has a morbidity risk. Hence, there is a need for the development of an effective non-pharmacological and non-invasive treatment for this disorder, one that has few side effects. In this review, we consider the effectiveness of a potential new treatment for epilepsy, known as photobiomodulation, the use of red to near-infrared light on body tissues. Recent studies in animal models have shown that photobiomodulation reduces seizure-like activity and improves neuronal survival. Further, it has an excellent safety record, with little or no evidence of side effects, and it is non-invasive. Taken all together, this treatment appears to be an ideal treatment option for patients suffering from epilepsy, which is certainly worthy of further consideration.

3.
Sci Rep ; 12(1): 17499, 2022 10 19.
Article in English | MEDLINE | ID: mdl-36261689

ABSTRACT

Parkinsonian patients often experience sleep/wake disturbances, which may appear at an early stage of the disease; however, these disturbances have not been fully described. To better understand the evolution of these disturbances with respect to disease progression, we aimed to characterize these clinical signs in a progressive nonhuman primate model of Parkinson's disease. Three adult macaques (Macaca fascicularis) were equipped with a polysomnographic telemetry system allowing the characterization of sleep/wake behavior via long-term neurophysiological recordings and underwent a modified multiple sleep latency test. Experiments were first performed in a healthy state and then during the progressive induction of a parkinsonian syndrome by intramuscular injections of low doses of MPTP. We observed an early onset of significant sleep/wake disturbances (i.e., before the appearance of motor symptoms). These disturbances resulted in (i) a disorganization of nighttime sleep with reduced deep sleep quality and (ii) an excessive daytime sleepiness characterized by sleep episodes occurring more rapidly in the morning and spreading through the middle of the day. The present study suggests that nighttime and daytime sleep/wake disturbances may appear early in the disease and should be considered in the development of biomarkers in further studies.


Subject(s)
Parkinson Disease , Sleep Wake Disorders , Animals , 1-Methyl-4-phenyl-1,2,3,6-tetrahydropyridine , Sleep Wake Disorders/etiology , Sleep/physiology , Macaca fascicularis
4.
Lancet Neurol ; 18(12): 1112-1122, 2019 12.
Article in English | MEDLINE | ID: mdl-31587955

ABSTRACT

BACKGROUND: Approximately 20% of traumatic cervical spinal cord injuries result in tetraplegia. Neuroprosthetics are being developed to manage this condition and thus improve the lives of patients. We aimed to test the feasibility of a semi-invasive technique that uses brain signals to drive an exoskeleton. METHODS: We recruited two participants at Clinatec research centre, associated with Grenoble University Hospital, Grenoble, France, into our ongoing clinical trial. Inclusion criteria were age 18-45 years, stability of neurological deficits, a need for additional mobility expressed by the patient, ambulatory or hospitalised monitoring, registration in the French social security system, and signed informed consent. The exclusion criteria were previous brain surgery, anticoagulant treatments, neuropsychological sequelae, depression, substance dependence or misuse, and contraindications to magnetoencephalography (MEG), EEG, or MRI. One participant was excluded because of a technical problem with the implants. The remaining participant was a 28-year-old man, who had tetraplegia following a C4-C5 spinal cord injury. Two bilateral wireless epidural recorders, each with 64 electrodes, were implanted over the upper limb sensorimotor areas of the brain. Epidural electrocorticographic (ECoG) signals were processed online by an adaptive decoding algorithm to send commands to effectors (virtual avatar or exoskeleton). Throughout the 24 months of the study, the patient did various mental tasks to progressively increase the number of degrees of freedom. FINDINGS: Between June 12, 2017, and July 21, 2019, the patient cortically controlled a programme that simulated walking and made bimanual, multi-joint, upper-limb movements with eight degrees of freedom during various reach-and-touch tasks and wrist rotations, using a virtual avatar at home (64·0% [SD 5·1] success) or an exoskeleton in the laboratory (70·9% [11·6] success). Compared with microelectrodes, epidural ECoG is semi-invasive and has similar efficiency. The decoding models were reusable for up to approximately 7 weeks without recalibration. INTERPRETATION: These results showed long-term (24-month) activation of a four-limb neuroprosthetic exoskeleton by a complete brain-machine interface system using continuous, online epidural ECoG to decode brain activity in a tetraplegic patient. Up to eight degrees of freedom could be simultaneously controlled using a unique model, which was reusable without recalibration for up to about 7 weeks. FUNDING: French Atomic Energy Commission, French Ministry of Health, Edmond J Safra Philanthropic Foundation, Fondation Motrice, Fondation Nanosciences, Institut Carnot, Fonds de Dotation Clinatec.


Subject(s)
Brain-Computer Interfaces , Exoskeleton Device , Implantable Neurostimulators , Proof of Concept Study , Quadriplegia/rehabilitation , Wireless Technology , Adult , Cervical Vertebrae/diagnostic imaging , Cervical Vertebrae/injuries , Cervical Vertebrae/surgery , Epidural Space/diagnostic imaging , Epidural Space/surgery , Humans , Magnetic Resonance Imaging/methods , Magnetoencephalography/methods , Male , Quadriplegia/diagnostic imaging , Quadriplegia/surgery , Sensorimotor Cortex/diagnostic imaging , Sensorimotor Cortex/surgery , Spinal Cord Injuries/diagnostic imaging , Spinal Cord Injuries/rehabilitation , Spinal Cord Injuries/surgery , Wireless Technology/instrumentation
5.
J Neural Eng ; 16(6): 066047, 2019 11 19.
Article in English | MEDLINE | ID: mdl-31374559

ABSTRACT

OBJECTIVE: The goal of this study was to evaluate the long-term behavior of the surface electrode through electrochemical characterization and follow-up of implanted parylene/platinum microelectrodes. APPROACH: To this aim, we designed and manufactured specific planar electrodes for cortical implantation for a rat model. This work was included in the INTENSE® project, one of the goals of which was to prove the feasibility of selective neural recording or stimulation with cuff electrodes around the vagus nerve. MAIN RESULTS: After a 12-week implantation in a rat model, we can report that these microelectrodes have withstood in vivo use. Regarding the biocompatibility of the electrodes (materials and manufacturing process), no adverse effect was reported. Indeed, after the three-month implantation, we characterized limited tissue reaction beneath the electrodes and showed an increase and a stabilization of their impedance. Interestingly, the follow-up of the electrochemical impedance combined with electrical stimulation highlighted a drop in the impedance up to 60% at 1 kHz after ten minutes of electrical stimulation at 110 Hz. SIGNIFICANCE: This study gives evidence of the biocompatibility of the parylene platinum contact array designed for the project and confirms the effect of stimulation on the contact impedance.


Subject(s)
Biocompatible Materials/standards , Brain/physiology , Electrodes, Implanted/standards , Polymers/standards , Xylenes/standards , Age Factors , Animals , Electric Stimulation/methods , Microelectrodes/standards , Rats , Reproducibility of Results
6.
Bioelectrochemistry ; 129: 79-89, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31125924

ABSTRACT

When implantable recording devices for brain or neural electrical activity are designed, the number of available materials for electrodes is quite limited. The material must be biocompatible with respect to ISO10993, its electrochemical properties must remain stable and the response of cells or tissues can be mitigated, especially on the glial scar. This involves electrode characterization pre- implantation and impedance spectroscopy during chronic implantation, in order to evaluate both electrode properties and performance. This study was aimed at a comparison of the long-term behavior of a nanostructured boron-doped diamond (BDD) with a nanostructured Platinum Iridium (PtIr) electrode. Firstly, a batch of cortical grids with bare and modified contacts (2 mm in diameter) was engineered for implantation. Secondly a miniature swine model was developed. This study highlighted the predominant role of electrode surface roughness on the quality of recordings. Rough PtIr contacts and BDD coated ones showed comparable behavior after three-month implantation with a slight increase of the modulus of the impedance and a tissue capsule. Nevertheless, immunohistochemistry analysis did not exhibit either a toxic or irritation reaction. With regard to biocompatibility, promising long term results are shown for both materials.


Subject(s)
Biocompatible Materials/chemistry , Boron/chemistry , Diamond/chemistry , Electrodes, Implanted , Nanostructures/chemistry , Animals , Biocompatible Materials/adverse effects , Boron/adverse effects , Brain/ultrastructure , Diamond/adverse effects , Dielectric Spectroscopy , Electrochemical Techniques , Electrodes, Implanted/adverse effects , Glial Fibrillary Acidic Protein/analysis , Nanostructures/adverse effects , Nanostructures/ultrastructure , Swine , Swine, Miniature
7.
Neuromodulation ; 21(2): 149-159, 2018 Feb.
Article in English | MEDLINE | ID: mdl-28685918

ABSTRACT

BACKGROUND: Brain Computer Interface (BCI) studies are performed in an increasing number of applications. Questions are raised about electrodes, data processing and effectors. Experiments are needed to solve these issues. OBJECTIVE: To develop a simple BCI set-up to easier studies for improving the mathematical tools to process the ECoG to control an effector. METHOD: We designed a simple BCI using transcranial electrodes (17 screws, three mechanically linked to create a common reference, 14 used as recording electrodes) to record Electro-Cortico-Graphic (ECoG) neuronal activities in rodents. The data processing is based on an online self-paced non-supervised (asynchronous) BCI paradigm. N-way partial least squares algorithm together with Continuous Wavelet Transformation of ECoG recordings detect signatures related to motor activities. Signature detection in freely moving rats may activate external effectors during a behavioral task, which involved pushing a lever to obtain a reward. RESULTS: After routine training, we showed that peak brain activity preceding a lever push (LP) to obtain food reward was located mostly in the cerebellar cortex with a higher correlation coefficient, suggesting a strong postural component and also in the occipital cerebral cortex. Analysis of brain activities provided a stable signature in the high gamma band (∼180Hz) occurring within 1500 msec before the lever push approximately around -400 msec to -500 msec. Detection of the signature from a single cerebellar cortical electrode triggers the effector with high efficiency (68% Offline and 30% Online) and rare false positives per minute in sessions about 30 minutes and up to one hour (∼2 online and offline). CONCLUSIONS: In summary, our results are original as compared to the rest of the literature, which involves rarely rodents, a simple BCI set-up has been developed in rats, the data show for the first time long-term, up to one year, unsupervised online control of an effector.


Subject(s)
Brain-Computer Interfaces , Brain/physiology , Evoked Potentials/physiology , Wakefulness/physiology , Algorithms , Animals , Brain Mapping , Electrodes, Implanted , Electroencephalography , Female , Longitudinal Studies , Online Systems , Physical Stimulation , Psychomotor Performance/physiology , Rats , Time Factors , User-Computer Interface
8.
Front Syst Neurosci ; 9: 73, 2015.
Article in English | MEDLINE | ID: mdl-26029061

ABSTRACT

Artificial brain-machine interfaces (BMIs) represent a prospective step forward supporting or replacing faulty brain functions. So far, several obstacles, such as the energy supply, the portability and the biocompatibility, have been limiting their effective translation in advanced experimental or clinical applications. In this work, a novel 16 channel chronically implantable epicortical grid has been proposed. It provides wireless transmission of cortical recordings and stimulations, with induction current recharge. The grid has been chronically implanted in a non-human primate (Macaca fascicularis) and placed over the somato-motor cortex such that 13 electrodes recorded or stimulated the primary motor cortex and three the primary somatosensory cortex, in the deeply anaesthetized animal. Cortical sensory and motor recordings and stimulations have been performed within 3 months from the implant. In detail, by delivering motor cortex epicortical single spot stimulations (1-8 V, 1-10 Hz, 500 ms, biphasic waves), we analyzed the motor topographic precision, evidenced by tunable finger or arm movements of the anesthetized animal. The responses to light mechanical peripheral sensory stimuli (blocks of 100 stimuli, each single stimulus being <1 ms and interblock intervals of 1.5-4 s) have been analyzed. We found 150-250 ms delayed cortical responses from fast finger touches, often spread to nearby motor stations. We also evaluated the grid electrical stimulus interference with somatotopic natural tactile sensory processing showing no suppressing interference with sensory stimulus detection. In conclusion, we propose a chronically implantable epicortical grid which can accommodate most of current technological restrictions, representing an acceptable candidate for BMI experimental and clinical uses.

9.
Article in English | MEDLINE | ID: mdl-25570185

ABSTRACT

The goal of the CLINATEC® Brain Computer Interface (BCI) Project is to improve tetraplegic subjects' quality of life by allowing them to interact with their environment through the control of effectors, such as an exoskeleton. The BCI platform is based on a wireless 64-channel ElectroCorticoGram (ECoG) recording implant WIMAGINE®, designed for long-term clinical application, and a BCI software environment associated to a 4-limb exoskeleton EMY (Enhancing MobilitY). Innovative ECoG signal decoding algorithms will allow the control of the exoskeleton by the subject's brain activity. Currently, the whole BCI platform was tested in real-time in preclinical experiments carried out in nonhuman primates. In these experiments, the exoskeleton arm was controlled by means of the decoded neuronal activity.


Subject(s)
Brain-Computer Interfaces , Electrocorticography , Algorithms , Animals , Electrodes, Implanted , Electroencephalography , Exoskeleton Device , Macaca mulatta , Quality of Life , Signal Processing, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL
...