Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Neurosurgery ; 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38353523

ABSTRACT

BACKGROUND AND OBJECTIVES: ChatGPT is a natural language processing chatbot with increasing applicability to the medical workflow. Although ChatGPT has been shown to be capable of passing the American Board of Neurological Surgery board examination, there has never been an evaluation of the chatbot in triaging and diagnosing novel neurosurgical scenarios without defined answer choices. In this study, we assess ChatGPT's capability to determine the emergent nature of neurosurgical scenarios and make diagnoses based on information one would find in a neurosurgical consult. METHODS: Thirty clinical scenarios were given to 3 attendings, 4 residents, 2 physician assistants, and 2 subinterns. Participants were asked to determine if the scenario constituted an urgent neurosurgical consultation and what the most likely diagnosis was. Attending responses provided a consensus to use as the answer key. Generative pretraining transformer (GPT) 3.5 and GPT 4 were given the same questions, and their responses were compared with the other participants. RESULTS: GPT 4 was 100% accurate in both diagnosis and triage of the scenarios. GPT 3.5 had an accuracy of 92.59%, slightly below that of a PGY1 (96.3%), an 88.24% sensitivity, 100% specificity, 100% positive predictive value, and 83.3% negative predicative value in triaging each situation. When making a diagnosis, GPT 3.5 had an accuracy of 92.59%, which was higher than the subinterns and similar to resident responders. CONCLUSION: GPT 4 is able to diagnose and triage neurosurgical scenarios at the level of a senior neurosurgical resident. There has been a clear improvement between GPT 3.5 and 4. It is likely that the recent updates in internet access and directing the functionality of ChatGPT will further improve its utility in neurosurgical triage.

2.
Cureus ; 15(9): e45761, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37872915

ABSTRACT

Endoscopic third ventriculostomy (ETV) is an effective cerebrospinal fluid diversion procedure but can be complicated by the presence of a high-riding basilar artery (BA). A 70-year-old female presented with obstructive hydrocephalus caused by melanoma metastatic to the brainstem in the setting of a high-riding BA. ETV was successfully performed using the Penumbra Artemis™ Neuro evacuation device (Artemis; Penumbra Inc, Alameda, CA, USA) to minimize the risk of injury to the BA. This is to our knowledge the first known Artemis-assisted ETV reported in the English literature, which may reduce the risk of BA injury in selected patients. Further characterization of the benefits and limitations of this procedure is needed.

3.
Interv Neuroradiol ; : 15910199231207550, 2023 Oct 29.
Article in English | MEDLINE | ID: mdl-37899636

ABSTRACT

Flow diversion (FD) has become a mainstay treatment for large wide-necked aneurysms. Despite excellent safety and efficacy, the risk of thromboembolic complications necessitates the use of dual antiplatelet therapy (DAPT). The use of DAPT makes hemorrhagic complications of stenting carry high morbidity and mortality. Additionally, DAPT usage carries a risk of "nuisance" complications that do not directly impact intracranial circulation but need to be managed nonetheless. To circumvent this issue, the most recent generation of flow diverters have undergone surface modification with various compounds to confer blood compatibility to limit clotting and thrombosis. While these newer generation flow diverters are marketed to enhance ease of deployment, the goal is to eventually facilitate single antiplatelet use with flow diverter treatment. This generation of FDs have potential to expand indications beyond unruptured wide-necked aneurysms to include ruptured intracranial aneurysms without the necessity of DAPT. Currently, no comprehensive review details the molecular mechanisms and pre-clinical and clinical data on these modifications. We seek to fill this gap in the literature by consolidating information on the coating technology for four major FDs currently in clinical use-PipelineTM Flex and Vantage Shield TechnologyTM, FREDTMX, p48/64 hydrophilic coating, and Acandis Dervio® 2heal-to serve as a reference guide in neurointerventional aneurysm treatment. Although the Balt silkTM was one of the first FDs, it is uncoated, thus we will not cover this device in our review. A literature review was performed to obtain information on each coating technology for the major flow diverters currently on the market using international databases (PUBMED, Embase, Medline, Google Scholar). The search criteria used the keywords for each coating technology of interest "phosphorylcholine," "poly 2-methoxyethyl acrylate," "hydrophilic polymer coating," and "fibrin-heparin" Keywords related to the device names "Pipeline Shield," "Pipeline Shield with Flex Technology," "FRED," "FREDX," "p64," "p64-HPC," "Derivo 2heal" were also used. Studies that detailed the mechanism of action of the coating, any pre-clinical studies with surface-modified intravascular devices, and any clinical retrospective series, prospective series, or randomized clinical trials with surface-modified devices for aneurysm treatment were included.

4.
Interv Neuroradiol ; : 15910199231182456, 2023 Jun 13.
Article in English | MEDLINE | ID: mdl-37312530

ABSTRACT

BACKGROUND: Endovascular coiling of small, intracranial aneurysms remains controversial and difficult, despite advances in technology. METHODS: We retrospectively reviewed data for 62 small aneurysms (<3.99 mm) in 59 patients. Occlusion rates, complications rates, and coil packing densities were compared between subgroups based upon coil type and rupture status. RESULTS: Ruptured aneurysms predominated (67.7%). Aneurysms measured 2.99 ± 0.63 mm by 2.51 ± 0.61 mm with an aspect ratio of 1.21 ± 0.34 mm. Brands included Optima (Balt) (29%), MicroVention Hydrogel (24.2%), and Penumbra SMART (19.4%) coil systems. Average packing density was 34.3 ± 13.5 mm3. Occlusion rate was 100% in unruptured aneurysms; 84% utilized adjuvant devices. For ruptured aneurysms, complete occlusion or stable neck remnant was achieved in 88.6% while recanalization occurred in 11.4%. No rebleeding occurred. Average packing density (p = 0.919) and coil type (p = 0.056) did not impact occlusion. Aspect ratio was smaller in aneurysms with technical complications (p = 0.281), and aneurysm volume was significantly smaller in those with coil protrusion (p = 0.018). Complication rates did not differ between ruptured and unruptured aneurysms (22.6 vs. 15.8%, p = 0.308) or coil types (p = 0.830). CONCLUSION: Despite advances in embolization devices, coiling of small intracranial aneurysms is still scrutinized. High occlusion rates are achievable, especially in unruptured aneurysms, with coil type and packing density suggesting association with complete occlusion. Technical complications may be influenced by aneurysm geometry. Advances in endovascular technologies have revolutionized small aneurysm treatment, with this series demonstrating excellent aneurysm occlusion especially in unruptured aneurysms.

5.
Neurosurgery ; 86(6): E544-E550, 2020 06 01.
Article in English | MEDLINE | ID: mdl-32315427

ABSTRACT

BACKGROUND: Posterior cervical fusion (PCF) is performed to treat cervical myelopathy, radiculopathy, and/or deformity. Constructs ending at the cervicothoracic junction (CTJ) may lead to higher rates of adjacent segment disease, and much debate exists regarding crossing the CTJ due to paucity of data in the literature. OBJECTIVE: To determine whether extension of PCF constructs across the CTJ decreases incidence of adjacent segment disease and need for revision surgery. METHODS: A single-center retrospective case series of patients undergoing multilevel PCFs since 2011 with at least 6-mo follow-up was conducted. Outcomes were analyzed and compared based on caudal extent of instrumentation via multivariate regression. RESULTS: A total of 149 patients underwent PCF, with a mean follow-up of 18.9 mo. A total of 15 (10.1%) revisions were performed, 7 (4.7%) of which were related to the construct. Five (8.3%) revisions were performed for constructs ending at C6, 1 (5.3%) at C7, 1 (2.6%) at T1, and none (0%) at T2 (P = .035). Mean procedure duration was 215 min at C6, 214 min at C7, 239 min at T1, and 343 min at T2 (P = .001). Mean estimated blood loss was 224 mL at C6, 178 mL at C7, 308 mL at T1, and 575 mL at T2 (P = .001). There was no difference in length of stay, disposition, surgical site infection, or radiographic parameters. CONCLUSION: Extension of PCFs across the CTJ leads to lower early revision rates, but also to increased procedure duration and estimated blood loss. As such, decisions regarding caudal extent of instrumentation must weigh the risk of pseudarthrosis against that of longer procedures with higher blood loss.


Subject(s)
Cervical Vertebrae/surgery , Decompression, Surgical/methods , Spinal Diseases/surgery , Spinal Fusion/methods , Thoracic Vertebrae/surgery , Adult , Aged , Cervical Vertebrae/diagnostic imaging , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Spinal Diseases/diagnostic imaging , Thoracic Vertebrae/diagnostic imaging
6.
Cureus ; 8(7): e715, 2016 Jul 27.
Article in English | MEDLINE | ID: mdl-27610287

ABSTRACT

Mobile schwannomas of the spine have been sparsely documented in the literature. In cases referred to in existing literature, the migratory schwannoma was documented to occur in the lumbar spine. We added another case to the small available literature. In our case report, the patient had a previously known lumbar schwannoma that was being managed conservatively. Due to an acute change in clinical symptoms, repeat imaging was performed. A magnetic resonance imaging (MRI) of his spine revealed migration of the schwannoma two levels rostral to his recent imaging from six weeks earlier. The patient underwent surgical resection of his lesion. During the operation, the ultrasound was utilized to confirm the lesion prior to dural opening. In this report, we attempt to provide further evidence of the utility of an intraoperative ultrasound for intradural lesions and intend to add to the published literature of mobile schwannomas of the spine.

7.
Chem Commun (Camb) ; 48(47): 5922-4, 2012 Jun 14.
Article in English | MEDLINE | ID: mdl-22569576

ABSTRACT

In this communication, we introduce squaric acid derivatives as anhydrous proton conductors. We report the synthesis, characterization and proton conductivities of four squaric acid derivatives. The anhydrous proton conductivity of one of the derivatives was 2.3 × 10(-3) S cm(-1) at 110 °C, comparable to the conductivity of molten 1H-1,2,3-triazole or 1H-imidazole.

8.
Chem Commun (Camb) ; 47(19): 5566-8, 2011 May 21.
Article in English | MEDLINE | ID: mdl-21483908

ABSTRACT

In this communication, we show that liquid crystalline phases lower the activation energy barrier for proton transport. The liquid crystalline phases were obtained using a triphenylene core with alkyl chains bearing a triazole moiety at their termini.

SELECTION OF CITATIONS
SEARCH DETAIL
...