Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Eur J Clin Invest ; 53(1): e13862, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36004486

ABSTRACT

BACKGROUND: The number of patients with cardiac implantable electronic devices (CIEDs) undergoing radiotherapy (RT) for cancer treatment is growing. At present, prevalence and predictors of RT-induced CIEDs malfunctions are not defined. METHODS: Systematic review and meta-analysis conducted following the PRISMA recommendations. PubMed, Scopus and Google Scholar were searched from inception to 31/01/2022 for studies reporting RT-induced malfunctions in CIEDs patients. Aim was to assess the prevalence of RT-induced CIEDs malfunctions and identify potential predictors. RESULTS: Thirty-two out of 3962 records matched the inclusion criteria and were included in the meta-analysis. A total of 135 CIEDs malfunctions were detected among 3121 patients (6.6%, 95% confidence interval [CI]: 5.1%-8.4%). The pooled prevalence increased moving from pacemaker (PM) to implantable cardioverter defibrillator (ICD), and cardiac resynchronization therapy and defibrillator (CRT-D) groups (4.1%, 95% CI: 2.9-5.8; 8.2% 95% CI: 5.9-11.3; and 19.8%, 95% CI: 11.4-32.2 respectively). A higher risk ratio (RR) of malfunctions was found when neutron-producing energies were used as compared to non-neutron-producing energies (RR 9.98, 95% CI: 5.09-19.60) and in patients with ICD/CRT-D as compared to patients with PM/CRT-P (RR 2.07, 95% CI: 1.40-3.06). On the contrary, no association was found between maximal radiation dose at CIED >2 Gy and CIEDs malfunctions (RR 0.93; 95% CI: 0.31-2.76). CONCLUSIONS: Radiotherapy related CIEDs malfunction had a prevalence ranging from 4% to 20%. The use of neutron-producing energies and more complex devices (ICD/CRT-D) were associated with higher risk of device malfunction, while the radiation dose at CIED did not significantly impact on the risk unless higher doses (>10 Gy) were used.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans
2.
Echocardiography ; 39(4): 584-591, 2022 04.
Article in English | MEDLINE | ID: mdl-35277886

ABSTRACT

BACKGROUND: Acute right ventricular (RV) failure is common in patients hospitalized with COVID-19. Compared to the conventional echocardiographic parameters, right ventricular longitudinal strain (RVLS) is more sensitive and accurate for the diagnosis of RV systolic dysfunction. OBJECTIVE: Our purpose was to investigate the sustained RV dysfunction echo-quantified by RVLS in patients recovered from severe COVID-19. Furthermore, we aimed to assess whether disseminated intravascular coagulation (DIC) has a key role to predict the impaired RV strain. METHODS: Of 198 consecutive COVID-19 patients hospitalized from March 1, 2020, to April 15, 2020, 45 selected patients who survived from severe COVID-19 were enrolled in the study and referred to our echo-lab for transthoracic echocardiography 6-months after discharge. RVLS was calculated as the mean of the strain values of RV free wall. DIC was defined with a validated scoring system: DIC score equal to or more than 5 is compatible with overt-DIC. Categories of acute respiratory distress syndrome (ARDS) were defined based on PaO2 /FiO2 ratio. RESULTS: A total 26 of 45 patients showed impaired RVLS at 6-months' follow-up. DIC score was significantly higher in patients with worse RVLS than in those with better RVLS (4.8 ± .5 vs. 3.6 ± .6, p =.03). Stages of ARDS did not modulate this relationship. Finally, overt-DIC results the only independent predictor of sustained RV dysfunction (OR 1.233, 95% CI 1.041-1.934, p =.043). CONCLUSIONS: Sustained RV impairment frequently occurs in patients recovered from severe COVID-19. DIC plays a key role, resulting in an independent predictor of sustained RV dysfunction.


Subject(s)
COVID-19 , Disseminated Intravascular Coagulation , Heart Failure , Respiratory Distress Syndrome , Ventricular Dysfunction, Right , COVID-19/complications , Disseminated Intravascular Coagulation/complications , Humans , Ventricular Dysfunction, Right/complications , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Function, Right
3.
Biology (Basel) ; 11(3)2022 Mar 15.
Article in English | MEDLINE | ID: mdl-35336817

ABSTRACT

BACKGROUND: Atrial high rate episodes (AHRE) detected by cardiac implantable electronic devices (CIEDs) may be associated with a risk of progression towards long-lasting episodes (≥24 h) and clinical atrial fibrillation (AF). METHODS: Consecutive CIED patients presenting AHRE (with confirmation of an arrhythmia lasting 5 min-23 h 59 min, atrial rate ≥175/min, with no AF at 12-lead ECG and no prior clinical AF) were retrospectively enrolled. The aims of this study were to describe patients' characteristics and the incidence of adverse events, and second, to identify potential predictors of the composite outcome of clinical AF and/or AHRE episodes lasting ≥24 h. RESULTS: 104/107 (97.2%) patients (median age 79.7 (74.0-84.2), 33.7% female) had available follow-up data. Over a median follow-up of 24.3 (10.6-40.3) months, 31/104 (29.8%) patients experienced the composite outcome of clinical AF or AHRE episodes lasting ≥24 h. Baseline CHA2DS2-VASc score and the longest AHRE episode at enrollment lasting 12 h-23 h 59 min were independently associated with the composite outcome (Hazard ratio (HR); 95% CI: 1.40; 1.07-1.83 and HR: 8.15; 95% CI 2.32-28.65, respectively). Baseline CHA2DS2-VASc score and the longest AHRE episode at enrollment lasting 12 h-23 h 59 min were the only independent predictors of incident clinical AF (HR: 1.45; 95% CI 1.06-2.00 and HR: 4.25; 95% CI 1.05-17.20, respectively). CONCLUSIONS: In patients with AHRE, the incidence of clinical AF or AHRE episodes lasting ≥24 h is high in a two-year follow-up. Baseline patients' characteristics (CHA2DS2-VASc score) and AHRE duration may help to intensify monitoring and decision-making, being independently associated with clinical AF at follow-up.

4.
Curr Cardiol Rep ; 23(6): 55, 2021 05 07.
Article in English | MEDLINE | ID: mdl-33959819

ABSTRACT

PURPOSE OF REVIEW: Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) is recommended as part of the individualized multidisciplinary follow-up of heart failure (HF) patients. Aim of this article is to critically review recent findings on RM, highlighting potential benefits and barriers to its implementation. RECENT FINDINGS: Device-based RM is useful in the early detection of CIEDs technical issues and cardiac arrhythmias. Moreover, RM allows the continuous monitoring of several patients' clinical parameters associated with impending HF decompensation, but there is still uncertainty regarding its effectiveness in reducing mortality and hospitalizations. Implementation of RM strategies, together with a proactive physicians' attitude towards clinical actions in response to RM data reception, will make RM a more valuable tool, potentially leading to better outcomes.


Subject(s)
Defibrillators, Implantable , Heart Failure , Telemedicine , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Heart Failure/diagnosis , Heart Failure/therapy , Hospitalization , Humans
SELECTION OF CITATIONS
SEARCH DETAIL