Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Mol Cytogenet ; 12: 34, 2019.
Article in English | MEDLINE | ID: mdl-31338126

ABSTRACT

INTRODUCTION: Non-Invasive Prenatal Testing (NIPT) for fetal aneuploidies using cell-free DNA (cfDNA) has been widely adopted in clinical practice due to its improved accuracy. A number of NIPT tests have been developed and validated. The purpose of this study is to evaluate the performance of the Veracity NIPT test for sex chromosome aneuploidy (SCA) detection in singleton pregnancies, autosomal aneuploidy detection in twin pregnancies and evaluation of Veracity clinical performance under routine NIPT conditions in a diverse cohort. METHODS: Blinded retrospective study in singleton pregnancies (n = 305); blinded retrospective and prospective study in twin pregnancies (n = 306) and prospective evaluation of clinical performance in singleton and twin pregnancies (n = 10564). RESULTS: Validation study results for the detection of SCAs in singleton pregnancies exhibited 100% sensitivity and specificity and correctly classified 7 (45,X), 4 (47,XXY), 2 (47,XXX) and 1 (47,XYY) cases. Validation study results for autosomal aneuploidy detection in twin pregnancies exhibited 100% sensitivity and specificity and correctly classified 3 trisomy 21, 1 trisomy 18 and 1 trisomy 13 samples. Clinical performance evaluation of Veracity was performed in 10564 pregnancies with median gestational age of 13 weeks, median maternal age 35 years and median gestational weight of 64 kg. Based on confirmation feedback the PPV for trisomies 21, 18 and 13 was estimated at 100% (95% CI, 92-100%), 100% (95% CI, 69-100%) and 71% (95% CI, 29-96%), respectively. Estimated PPV for Monosomy X was 57% (95%CI, 18-90%), while the NPV for SCA detection was estimated at 100% (95% CI, 99.94-100%). CONCLUSION: Veracity NIPT test is based on a very powerful, highly accurate methodology that can be safely applied in the clinical setting.

2.
Prenat Diagn ; 32(10): 996-1001, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22833530

ABSTRACT

OBJECTIVE: To reevaluate the efficiency of the 12 differentially methylated regions (DMRs) used in the methylated DNA immunoprecipitation (MeDIP) real-time quantitative polymerase chain reaction (real-time qPCR) based approach, develop an improved version of the diagnostic formula and perform a larger validation study. METHODS: Twelve selected DMRs were checked for copy number variants in the Database of Genomic Variants. The DMRs located within copy number variants were excluded from the analysis. One hundred and seventy-five maternal peripheral blood samples were used to reconstruct and evaluate the new diagnostic formula and for a larger-scale blinded validation study using MeDIP real-time qPCR. RESULTS: Seven DMRs entered the final model of the prediction equation and a larger blinded validation study demonstrated 100% sensitivity and 99.2% specificity. No significant evidence for association was observed between cell free fetal DNA concentration and D value. CONCLUSION: The MeDIP real-time qPCR method for noninvasive prenatal diagnosis of trisomy 21 was confirmed and revalidated in 175 samples with satisfactory results demonstrating that it is accurate and reproducible. We are currently working towards simplification of the method to make it more robust and therefore easily, accurately, and rapidly reproduced and adopted by other laboratories. Nevertheless, larger scale validation studies are necessary before the MeDIP real-time qPCR-based method could be applied in clinical practice.


Subject(s)
DNA Methylation/genetics , DNA/blood , Down Syndrome/diagnosis , Immunosorbent Techniques , Prenatal Diagnosis/methods , Real-Time Polymerase Chain Reaction/methods , Adult , Down Syndrome/genetics , Female , Fetus/chemistry , Gestational Age , Humans , Pregnancy , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...