Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J Invasive Cardiol ; 34(11): E811-E819, 2022 11.
Article in English | MEDLINE | ID: mdl-36318461

ABSTRACT

OBJECTIVE: Thinner stent struts might lead to a higher risk of recoil and subsequently a smaller minimal stent area (MSA), which is known to be the strongest predictor of stent failure. We compared procedural performance between an ultrathin-strut biodegradable-polymer sirolimus-eluting stent (BP-SES) and a durable-polymer zotarolimus-eluting stent (DP-ZES) using intracoronary imaging. METHODS: A consecutive cohort of patients underwent percutaneous coronary intervention (PCI) with either BP-SES or DP-ZES in a pseudorandomized fashion between July 2018 and October 2019. In the present subanalysis, we included cases in which post-PCI imaging with intravascular ultrasound (IVUS) or optical coherence tomography (OCT) was performed. The primary endpoint of the study was MSA. Secondary endpoints included percentage stent expansion and presence of residual edge disease, malapposition, tissue protrusion, submedial edge dissections, or edge hematoma. RESULTS: A total of 141 treated lesions (78 BP-SES and 63 DP-ZES) in 127 patients were analyzed. Median age was 69.3 years (interquartile range [IQR], 57.3-75.6) and 74.0% of patients were male. All baseline and procedural characteristics were comparable between both groups. Median MSA was 5.80 mm² (IQR, 4.40-7.24) for BP-SES and 6.35 mm² (IQR, 4.76-8.31) for DP-ZES (P=.15). No significant differences in stent expansion, residual edge disease and presence of malapposition, tissue protrusion, submedial edge dissections, or edge hematomas were found. Stent diameter and stent length were found to be independent predictors of MSA. CONCLUSIONS: No significant differences in MSA were found between lesions treated with BP-SES vs DP-ZES. BP-SES and DP-ZES were comparable in terms of procedural performance.


Subject(s)
Cardiovascular Agents , Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Male , Aged , Female , Everolimus , Absorbable Implants , Polymers , Coronary Artery Disease/therapy , Prosthesis Design , Treatment Outcome
2.
JACC Cardiovasc Interv ; 15(16): 1595-1607, 2022 08 22.
Article in English | MEDLINE | ID: mdl-35981832

ABSTRACT

BACKGROUND: Post-percutaneous coronary intervention (PCI) fractional flow reserve (FFR) <0.90 is common and has been related to impaired patient outcome. OBJECTIVES: The authors sought to evaluate if PCI optimization directed by intravascular ultrasound (IVUS) in patients with post-PCI FFR <0.90 could improve 1-year target vessel failure (TVF) rates. METHODS: In this single-center, randomized, double-blind trial, patients with a post-PCI FFR <0.90 at the time of angiographically successful PCI were randomized to IVUS-guided optimization or the standard of care (control arm). The primary endpoint was TVF (a composite of cardiac death, spontaneous target vessel myocardial infarction, and clinically driven target vessel revascularization) at 1 year. RESULTS: A total of 291 patients with post-PCI FFR <0.90 were randomized (IVUS-guided optimization arm: n = 145/152 vessels, control arm: n = 146/157 vessels). The mean post-PCI FFR was 0.84 ± 0.05. A total of 104 (68.4%) vessels in the IVUS-guided optimization arm underwent additional optimization including additional stenting (34.9%) or postdilatation only (33.6%), resulting in a mean increase in post-PCI FFR in these vessels from 0.82 ± 0.06 to 0.85 ± 0.05 (P < 0.001) and a post-PCI FFR ≥0.90 in 20% of the vessels. The 1-year TVF rate was comparable between the 2 study arms (IVUS-guided optimization arm: 4.2%, control arm: 4.8%; P = 0.79). There was a trend toward a lower incidence of clinically driven target vessel revascularization in the IVUS-guided optimization arm (0.7% vs. 4.2%, P = 0.06). CONCLUSIONS: IVUS-guided post-PCI FFR optimization significantly improved post-PCI FFR. Because of lower-than-expected event rates, post-PCI FFR optimization did not significantly lower TVF at the 1-year follow-up.


Subject(s)
Coronary Artery Disease , Fractional Flow Reserve, Myocardial , Percutaneous Coronary Intervention , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Humans , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Standard of Care , Treatment Outcome
3.
J Cardiovasc Transl Res ; 14(5): 992-1000, 2021 10.
Article in English | MEDLINE | ID: mdl-33624259

ABSTRACT

BACKGROUND: Coronary calcification has been linked to cardiovascular events. We developed and validated an algorithm to automatically quantify coronary calcifications on intravascular ultrasound (IVUS). We aimed to assess the prognostic value of an IVUS-calcium score (ICS) on patient-oriented composite endpoint (POCE). METHODS: We included patients that underwent coronary angiography plus pre-procedural IVUS imaging. The ICS was calculated per patient. The primary endpoint was a composite of all-cause mortality, stroke, myocardial infarction, and revascularization (POCE). RESULTS: In a cohort of 408 patients, median ICS was 85. Both an ICS ≥ 85 and a 100 unit increase in ICS increased the risk of POCE at 6-year follow-up (adjusted hazard ratio (aHR) 1.51, 95%CI 1.05-2.17, p value = 0.026, and aHR 1.21, 95%CI 1.04-1.41, p value = 0.014, respectively). CONCLUSIONS: The ICS, calculated by a validated automated algorithm derived from routine IVUS pullbacks, was strongly associated with the long-term risk of POCE.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Ultrasonography, Interventional , Vascular Calcification/diagnostic imaging , Aged , Automation , Coronary Angiography , Coronary Artery Disease/mortality , Coronary Artery Disease/therapy , Disease Progression , Female , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Myocardial Revascularization , Predictive Value of Tests , Prognosis , Reproducibility of Results , Retrospective Studies , Risk Assessment , Risk Factors , Severity of Illness Index , Vascular Calcification/mortality , Vascular Calcification/therapy
4.
Catheter Cardiovasc Interv ; 97(4): E495-E501, 2021 03.
Article in English | MEDLINE | ID: mdl-32725862

ABSTRACT

OBJECTIVES: We aimed to evaluate the feasibility of using three dimensional-quantitative coronary angiography (3D-QCA) based fractional flow reserve (FFR) (vessel fractional flow reserve [vFFR], CAAS8.1, Pie Medical Imaging) and to correlate vFFR values with intravascular ultrasound (IVUS) for the evaluation of intermediate left main coronary artery (LMCA) stenosis. BACKGROUND: 3D-QCA derived FFR indices have been recently developed for less invasive functional lesion assessment. However, LMCA lesions were vastly under-represented in first validation studies. METHODS: This observational single-center cohort study enrolled consecutive patients with stable angina, unstable angina, or non-ST-segment elevation myocardial infarction and nonostial, intermediate grade LMCA stenoses who underwent IVUS evaluation. vFFR was computed based on two angiograms with optimal LMCA stenosis projection and correlated with IVUS-derived minimal lumen area (MLA). RESULTS: A total of 256 patients with intermediate grade LMCA stenosis evaluated with IVUS were screened for eligibility; 147 patients met the clinical inclusion criteria and had a complete IVUS LMCA footage available, of them, 63 patients (63 lesions) underwent 3D-QCA and vFFR analyses. The main reason for screening failure was insufficient quality of the angiogram (51 patients,60.7%). Mean age was 65 ± 11 years, 75% were male. Overall, mean MLA within LMCA was 8.77 ± 3.17 mm2 , while mean vFFR was 0.87 ± 0.09. A correlation was observed between vFFR and LMCA MLA (r = .792, p = .001). The diagnostic accuracy of vFFR ≤0.8 in identifying lesions with MLA < 6.0 mm2 (sensitivity 98%, specificity 71.4%, area under the curve (AUC) 0.95, 95% confidence interval (CI) 0.89-1.00, p = .001) was good. CONCLUSIONS: In patients with good quality angiographic visualization of LMCA and available complete LMCA IVUS footage, 3D-QCA based vFFR assessment of LMCA disease correlates well to LMCA MLA as assessed by IVUS.


Subject(s)
Coronary Stenosis , Fractional Flow Reserve, Myocardial , Cohort Studies , Coronary Angiography , Coronary Stenosis/diagnostic imaging , Coronary Vessels/diagnostic imaging , Humans , Male , Predictive Value of Tests , Severity of Illness Index , Treatment Outcome , Ultrasonography, Interventional
5.
Catheter Cardiovasc Interv ; 93(2): 233-238, 2019 02 01.
Article in English | MEDLINE | ID: mdl-30260080

ABSTRACT

BACKGROUND: Angiographic assessment of left main coronary artery (LMCA) lesions remains challenging and limited data is available on reference diameters and length of nonobstructive LMCA dimensions. Our aim was to provide insights in the dimensions of nonobstructive LMCA and to find a possible correlation with gender and patient habitus. METHODS: This retrospective single center study was performed in a consecutive cohort of patients who underwent Intravascular Ultrasound (IVUS) guided percutaneous coronary interventions of the left coronary system including complete pullbacks of a non-obstructive LMCA (n = 254). RESULTS: Mean LMCA length as measured with IVUS was 7.37 ± 4.2 mm and mean lumen area (LA) was 15.63 ± 4.76 mm2 corresponding to a mean lumen diameter (LD) of 4.41 ± 0.67 mm. An IVUS derived mean LD of >4 mm was present in 71.7%, >4.5 mm in 43% and > 5 mm in 19% of patients. LMCA mean LA was significantly smaller in women as compared to men (14.1 ± 4.1 mm2 and 16.2 ± 4.8 mm2 , P < 0.01). Multivariable analysis identified weight of the patient as the sole significant predictor for LMCA length while height of the patient and LMCA length were predictors of LMCA mean LA. Correlation coefficients of determination for all independent predictors were low (R2 < 0.1 for all). CONCLUSION: This study demonstrated that the mean LD of a non-obstructive LMCA is 4 mm or greater in the majority of patients, with a mean LMCA length of 7.4 mm. Women have smaller luminal dimension than men. No clinically relevant predictors were found for both LMCA length and mean LA.


Subject(s)
Coronary Vessels/diagnostic imaging , Ultrasonography, Interventional , Aged , Body Height , Body Weight , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Reference Values , Retrospective Studies , Sex Factors , Ultrasonography, Interventional/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...