Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Biomech (Bristol, Avon) ; 114: 106233, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38531152

ABSTRACT

BACKGROUND: Sacroiliac joints are affected by mechanical environments; the joints are formed under mechanical stimulation, receive impact of walking between the upper and lower parts of the bodies and can be a cause of pain due to non-physiological loads. However, there are so far very few studies that reviewed biomechanics of physiological and pathological sacroiliac joints. This review article aims to describe the current sacroiliac joint biomechanics. METHODS: Previous original papers have been summarized based on three categories: articular surface structure, sacroiliac joint motion and sacroiliac joint dysfunction and treatments. FINDINGS: Although the articular surface morphologies vary greatly from individual to individual, many researchers have tried to classify the joints into several types. It has been suggested that the surface morphologies may not change regardless of joint dysfunction, however, the relationship between the joint structure and pain are still unclear. The range of sacroiliac joint motion is demonstrated to be less than 1 mm and there is no difference between physiological and pathological joints. The sacroiliac joint absorbs shock within the pelvis by the joint structures of pelvic morphology, ligaments and fat tissues. The morphology and motion of the sacroiliac joints may be optimized for upright bipedal walking. INTERPRETATION: There is no doubt that pelvic mechanical environments affect pain induction and treatment; however, no one has yet provided a concrete explanation. Future research could help develop treatments based on sacroiliac joint biomechanics to support joint function.


Subject(s)
Joint Diseases , Sacroiliac Joint , Humans , Sacroiliac Joint/physiology , Pelvis/physiology , Motion , Ligaments , Pain , Biomechanical Phenomena
2.
Biomed Mater Eng ; 35(1): 53-63, 2024.
Article in English | MEDLINE | ID: mdl-37545208

ABSTRACT

BACKGROUND: The human sacroiliac joint (SIJ) in vivo is exposed to compressive and shearing stress environment, given the joint lines are almost parallel to the direction of gravity. The SIJ supports efficient bipedal walking. Unexpected or unphysiological, repeated impacts are believed to cause joint misalignment and result in SIJ pain. In the anterior compartment of the SIJ being synovial, the articular surface presents fine irregularities, potentially restricting the motion of the joints. OBJECTIVE: To clarify how the SIJ articular surface affects the resistance of the motion under physiological loading. METHODS: SIJ surface models were created based on computed tomography data of three patients and subsequently 3D printed. Shear resistance was measured in four directions and three combined positions using a customized setup. In addition, repositionability of SIJs was investigated by unloading a shear force. RESULTS: Shear resistance of the SIJ was the highest in the inferior direction. It changed depending on the direction of the shear and the alignment position of the articular surface. CONCLUSION: SIJ articular surface morphology is likely designed to accommodate upright bipedal walking. Joint misalignment may in consequence increase the risk of subluxation.


Subject(s)
Sacroiliac Joint , Standing Position , Humans , Sacroiliac Joint/diagnostic imaging , Sacroiliac Joint/anatomy & histology , Sacroiliac Joint/physiology , Motion , Stress, Mechanical , Range of Motion, Articular/physiology
3.
Biomed Mater Eng ; 34(4): 305-318, 2023.
Article in English | MEDLINE | ID: mdl-36502302

ABSTRACT

BACKGROUND: Pain related to the sacroiliac joint (SIJ) accounts for low back pain in 15%-30% of patients. One of the most common treatment options is the use of pelvic belts. Various types of pelvic belts exist; however, the mechanisms underlying treatment and their effectiveness remain unclear to date. OBJECTIVE: To analyze stress distribution in the pelvis when a pelvic rubber belt or a padded pelvic belt is applied, to assess the effectiveness of treatment from a numerical biomechanical perspective. METHODS: The pressure distribution at the pelvic belts was measured using a device and subsequently modeled with the finite element method of a pelvis with soft tissues. The stress environment when wearing a pelvic belt in a double-leg stance was simulated. RESULTS: With the application of pelvic belts, the innominate bone rotated outward, which was termed an out-flare. This caused the SIJ to compress and cause reduction in sacrotuberous, sacrospinous, interosseous, and posterior sacroiliac ligament loading. Padded pelvic belts decreased the SIJ displacement to a greater extent than in pelvic rubber belts. CONCLUSION: Pelvic belts aid in compressing the SIJ and reduce its mobility.


Subject(s)
Pelvic Bones , Sacroiliac Joint , Humans , Rubber , Pelvis , Biomechanical Phenomena
4.
Sci Rep ; 12(1): 14500, 2022 08 25.
Article in English | MEDLINE | ID: mdl-36008525

ABSTRACT

In acetabular dysplasia, the cartilaginous roof on the acetabular side does not fully cover the femoral head, which may lead to abnormal stress distribution in both the femoral head and pelvis. These stress changes may have implications to the adjacent sacroiliac joint (SIJ). The SIJ has a minimal range of motion and is closely coupled to the adjacent spine and pelvis. In consequence, the SIJ may react sensitively to changes in stress distribution at the acetabulum, with hypermobility-induced pain. The purpose of this study was to investigate the stress distribution of the SIJ in acetabular dysplasia, and to gain insight into the cause and mechanisms of hypermobility-induced pain at the SIJ. Finite element models of pre- and postoperative pelves of four patients with acetabular dysplasia were created and analyzed in double leg standing positions. The preoperative models were relatively inflare, the sacral nutation movement, SIJ cartilage equivalent stress, and the load on the surrounding ligaments decreased with increased posterior acetabular coverage. Acetabular morphology was shown to affect the SIJ, and improvement of the posterior acetabular coverage may help normalize load transmission of the pelvis and thus improve the stress environment of the SIJ in acetabular dysplasia.


Subject(s)
Hip Dislocation, Congenital , Hip Dislocation , Acetabulum/surgery , Cohort Studies , Hip Dislocation, Congenital/surgery , Hip Joint/surgery , Humans , Pain , Sacroiliac Joint/anatomy & histology
5.
Sci Rep ; 10(1): 13683, 2020 08 13.
Article in English | MEDLINE | ID: mdl-32792529

ABSTRACT

The sacroiliac joint (SIJ) is burdened with variant loads. However, no methods have allowed to measure objectively how the SIJ deforms during bipedal walking. In this study, in-vivo walking conditions were replicated in a kinematic model combining the finite element method with 3D walking analysis data divided into five phases in order to visualize the load transition on the SIJ and clarify the role of the SIJ. Both models with and without inclusion of the SIJ were investigated. In models with bilateral SIJs, the displacement differed greatly between the sacrum and both hip bones on the SIJ as the boundary. The movements of the sacrum involved a nutation movement in the stance phase and a counter-nutation in the swing phase relative to the ilium. In models without SIJs, the displacement of the pelvis and loads of pelvic ligaments decreased, and the equivalent stress of the SIJs increased compared to the model with SIJs. The walking loads cause distortion of the entire pelvis, and stress concentration at the SIJ are seen due to the morphology of the pelvic ring. However, the SIJs help dissipate the resulting stresses, and the surrounding ligaments are likewise involved in load transmission.


Subject(s)
Pelvic Bones/physiology , Sacroiliac Joint/physiology , Sacrum/physiology , Walking/physiology , Adult , Biomechanical Phenomena , Computer Simulation , Finite Element Analysis , Humans , Male , Models, Biological , Range of Motion, Articular , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL
...