Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Drug Investig ; 30(10): 699-706, 2010.
Article in English | MEDLINE | ID: mdl-20701401

ABSTRACT

BACKGROUND: High-normal urinary albumin excretion has been reported to have clinical significance with respect to progression of proteinuria and hypertension. OBJECTIVE: We analysed the effect of cilnidipine (10 mg/day) on morning systolic blood pressure (SBP) and urine albumin-creatinine ratio (UACR) in 16 non-diabetic hypertensive patients with a normal to marginally elevated UACR (mean +/- SD 29.4 +/- 21.7; range 7.5-72.9 mg/g creatinine). METHODS: Sequential home BP and UACR data were fitted to a simple exponential function as follows: where y is SBP (mmHg) or UACR (mg/g creatinine); alpha is the extent of the SBP (mmHg)- or UACR (mg/g creatinine)-lowering effect; beta (days) is the time-constant for SBP or UACR decrease; t is the number of days after the start of cilnidipine administration; and gamma is the finally stabilized SBP (mmHg) or UACR (mg/g creatinine). RESULTS: Mean +/- SD morning SBP and UACR decreased by 20.4 +/- 11.4 mmHg and 15.2 +/- 13.1 mg/g creatinine, respectively, as determined by coefficient alpha. The mean +/- SD time-constant for UACR decrease was significantly longer than that for BP decrease (43.5 +/- 22.9 vs 15.4 +/- 7.1 days). UACR reduction correlated with pre-treatment UACR values (correlation coefficient [R] = 0.88, p < 0.01) but not with BP decrease. CONCLUSIONS: The present study demonstrated that cilnidipine reduced UACR in hypertensive patients with normal to marginally elevated UACR independent of its BP-lowering effect.


Subject(s)
Albuminuria/drug therapy , Antihypertensive Agents/therapeutic use , Calcium Channel Blockers/therapeutic use , Creatinine/urine , Dihydropyridines/therapeutic use , Hypertension/drug therapy , Models, Statistical , Albuminuria/etiology , Albuminuria/urine , Antihypertensive Agents/adverse effects , Biomarkers/urine , Blood Pressure/drug effects , Blood Pressure Monitoring, Ambulatory , Calcium Channel Blockers/adverse effects , Dihydropyridines/adverse effects , Humans , Hypertension/complications , Hypertension/physiopathology , Nephelometry and Turbidimetry , Time Factors , Treatment Outcome
2.
Heart Rhythm ; 6(8): 1163-9, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19632628

ABSTRACT

BACKGROUND: Repolarization abnormality, especially during bradycardia, might be critical for initiation of ventricular fibrillation (VF) in patients with Brugada syndrome (BrS), but the contribution of the rate-dependent repolarization dynamics to the occurrence of VF is still unknown. OBJECTIVE: The aim of our study was to determine the differences in rate-dependent repolarization dynamics between BrS with and without spontaneous VF and between BrS with and without SCN5A mutation. METHODS: The subjects were 37 BrS patients with VF (VF(+) group: 10 male subjects) and without VF (VF(-) group: 27 male subjects) and 20 control subjects. Genetic analysis of SCN5A was performed in all 37 BrS patients. The relationships between QT, QTp, Tp-e, and RR intervals were obtained from Holter recordings as first linear regression lines, and the slopes of QT/RR, QTp/RR, and Tp-e/RR linear regression lines as the sensitivity of rate-dependent repolarization dynamics were compared. RESULTS: QT/RR and Tp-e/RR slopes showed loss of a rate-dependent property in the VF(+) group compared with those in the VF(-) and control groups. There was no significant difference in QTp/RR slope among the VF(+), VF(-) and control groups. The Tp-e interval had a negative correlation with the RR interval in the VF(+) group and a positive correlation with the RR interval in the VF(-) and control groups. There was no significant difference in QT/RR, QTp/RR, and Tp-e/RR slopes between BrS patients with SCN5A mutation and those without SCN5A mutation. CONCLUSIONS: Loss of rate-dependent QT dynamics may be associated with occurrence of VF in BrS.


Subject(s)
Brugada Syndrome/physiopathology , Muscle Proteins/genetics , Sodium Channels/genetics , Adult , Aged , Analysis of Variance , Brugada Syndrome/diagnosis , Brugada Syndrome/genetics , Case-Control Studies , Electrocardiography, Ambulatory , Humans , Male , Middle Aged , NAV1.5 Voltage-Gated Sodium Channel , Statistics as Topic , Ventricular Fibrillation/genetics , Ventricular Fibrillation/physiopathology
3.
Clin Exp Hypertens ; 30(3): 191-201, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18425699

ABSTRACT

We examined the hemodynamic responses to exercise and symptoms in 37 male patients with untreated essential hypertension, and compared the findings with those in 32 age-matched healthy male volunteers by performing a graded symptom-limited exercise test using a bicycle ergometer. The subjective feeling of intensity of exercise was determined using the Borg scale. In the relationship between Borg scores and blood pressure (BP), patients with hypertension showed higher systolic BP and diastolic BP relative to the Borg scores than the controls. Consequently, patients with hypertension showed significantly higher systolic BP with Borg scores < or = 3 (subjective symptoms < or = moderately hard) than the controls (177.8 +/- 27.0 vs. 143.7 +/- 17.9 mmHg, p < 0.0001). Similarly, significantly higher diastolic BP with Borg scores < or = 3 was observed in patients with hypertension than in the controls (101.6 +/- 12.0 vs. 82.6 +/- 11.6 mmHg, p < 0.0001). The pulse pressure with Borg scores < or = 3 was also significantly higher in patients with hypertension than in the controls (76.2 +/- 20.6 vs. 61.0 +/- 13.6 mmHg, p < 0.0001). Hypertensive patients showed a decrease in the high-frequency power of heart rate variability at initial low-load exercise. In conclusion, the present study revealed that there was a greater BP response relative to the Borg score in patients with hypertension than in the controls. Autonomic nerve activity may contribute to some extent to these different relations. A determination of the relationship between the subjective feeling of intensity of the exercise and BP levels caused by a given intensity of load is essential before exercise training in patients, at least in males, with hypertension to avoid increasing the risk of cardiovascular events in association with excessive exercise training.


Subject(s)
Blood Pressure , Exercise , Hypertension/physiopathology , Hypertension/psychology , Exercise Test , Heart Rate , Hemodynamics , Humans , Male , Middle Aged , Psychophysics/methods , Self-Assessment
4.
J Hypertens ; 26(3): 535-43, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18300866

ABSTRACT

OBJECTIVES: The augmentation index of the radial pulse wave has been reported to be a sensitive aortic stiffness marker in relatively young but not in older individuals. We studied the relationship between augmentation index and the diurnal blood pressure profiles. PATIENTS AND METHODS: Twenty-four-hour ambulatory blood pressure monitoring was performed in 90 untreated patients with uncomplicated essential hypertension. The patients were classified into four groups: dippers, extreme dippers, nondippers, and risers. Augmentation index was calculated as the percentage of the second systolic peak relative to the first systolic peak. RESULTS: No significant differences in the averaged whole 24-h systolic or diastolic blood pressure were observed in the whole set of patients or in subgroup patients with age 60 years or under. In the whole set of patients (58.7 +/- 12.9 years), there were significant differences in augmentation index between patients with abnormal (other than dippers) and normal diurnal blood pressure profiles (dippers). In subgroup patients with age 60 years or below (49.1 +/- 9.1 years, n = 48), the abnormal diurnal blood pressure profile group showed significantly higher augmentation index (89.6 +/- 10.3%) than dippers (80.5 +/- 11.8%). The area under the curve in the receiver operating characteristics curve for distinguishing between dippers than other dippers was 0.73 (P < 0.01). Multivariate analysis demonstrated that abnormal diurnal blood pressure profile was independently associated with increase in augmentation index. In contrast, these relationships were not significant in the over 60 years subgroup patients (69.8 +/- 5.6 years old, n = 42). CONCLUSIONS: The present study revealed that augmentation index was associated with dipping blood pressure patterns in untreated hypertensive patients aged 60 years or younger. Augmentation index determination would be useful for initial assessment in connection with possible abnormal diurnal blood pressure variability in patients with age 60 years or younger.


Subject(s)
Blood Pressure/physiology , Hypertension/diagnosis , Hypertension/physiopathology , Radial Artery/physiopathology , Area Under Curve , Circadian Rhythm , Female , Humans , Male , Middle Aged , Monitoring, Ambulatory , Sensitivity and Specificity
5.
Hypertens Res ; 30(7): 651-8, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17785934

ABSTRACT

We examined the relationship between plasma B-type natriuretic peptide (BNP) level and diurnal variability pattern of blood pressure (BP). Twenty-four-hour ambulatory BP monitoring was performed in 98 patients with asymptomatic essential hypertension, and the patients were classified into four groups according to their circadian BP variation profiles: dippers (n=29), nondippers (n=36), extreme dippers (n=19), and risers (n=14). Plasma BNP was measured by enzyme immunoassay. Based on the distribution pattern of BNP values, the values were analyzed after logarithmic transformation. Significant differences in plasma BNP levels among the types of circadian BP variations were demonstrated by analysis of variance (p<0.0005). Nondippers and risers showed significantly higher plasma BNP levels (mean [range: -1 SD and +1 SD]: 16.1 [6.3, 41.6] pg/mL and 29.2 [15.9, 53.4] pg/mL, respectively) than dippers (8.4 [3.7, 19.1] pg/mL). The area under the receiver operating characteristics curve for distinguishing patients with abnormal circadian BP variation from those with normal variation was 0.72, indicating that plasma BNP levels were useful for distinguishing between these patients. Specificity of 69% and sensitivity of 72% were obtained with a cut-off value of 10.5 pg/mL (log plasma BNP, 1.02) for distinguishing the abnormal diurnal BP profile group from the normal group. In conclusion, hypertensive patients with abnormal diurnal BP variation patterns (nondippers, extreme dippers, and risers) showed higher plasma BNP levels than those with normal circadian BP variation (dippers). Plasma BNP level is clinically useful for the identification of hypertensive patients who have abnormal circadian BP variability, which increases the risk of cardiovascular events.


Subject(s)
Blood Pressure/physiology , Circadian Rhythm/physiology , Hypertension/blood , Hypertension/diagnosis , Natriuretic Peptide, Brain/blood , Adult , Aged , Biomarkers/blood , Blood Pressure Monitoring, Ambulatory , Electrocardiography , Female , Humans , Hypertension/physiopathology , Male , Middle Aged , Sensitivity and Specificity
6.
J Med Ultrason (2001) ; 34(1): 37-42, 2007 Mar.
Article in English | MEDLINE | ID: mdl-27278178

ABSTRACT

PURPOSE: Automatic Doppler flow signal detection systems can provide beat-to-beat information for large blood vessels. We have developed new equipment for automatic measurement of Doppler flow signals. The reliability of the system was examined, and the variability of aortic and pulmonary peak flow velocity was determined. METHODS: We measured peak flow velocity using a newly developed system in healthy volunteers and patients with atrial fibrillation. Analysis of variability of peak flow velocity was performed with maximal entropy methods. RESULTS: In Bland-Altman plots, the mean and standard deviation (SD) of differences in aortic peak flow velocities between the automatic and manual measurements were 0.22 ± 0.75 cm/s and 0.85 ± 0.38 cm/s, respectively, in five normal volunteers. Moreover, less than 5% of the plotted points were beyond ± 2 SD of the differences. Furthermore, good reproducibility was demonstrated using Bland-Altman plots and Pearson's correlation analysis. Identical reliability was obtained in patients with atrial fibrillation. The same results were obtained for pulmonary peak flow velocity. In five healthy subjects, aortic and pulmonary peak flow showed standard deviations of 7.2 ± 2.4 and 3.8 ± 0.6 cm/s, respectively, and coefficients of variation of 6.1% ± 1.0% and 5.1% ± 1.1%, respectively, in time-domain variability. Similarly, frequency-domain variability was obtained for both peak flow velocities. CONCLUSION: The present study demonstrated the reliability of a newly developed automatic Doppler flow signal detection system. Using this system, the present study demonstrated for the first time aortic and pulmonary peak flow velocity variability. The present analytical methods may have considerable potential for studying aortic and/or pulmonary flow variability in connection with cardiac performance and prognosis of cardiac disease.

7.
Biomed Pharmacother ; 56 Suppl 2: 353s-358s, 2002.
Article in English | MEDLINE | ID: mdl-12653193

ABSTRACT

Autonomic nerve activity shows circadian variation. Therefore, we put forward the hypothesis that the responses of heart rate (HR) and high-frequency (HF) power of HR variability to exercise would be different between early morning and daytime exercise. We performed ergometer constant load exercise tests [50 watts (low), 100 watts (high load)] in the early morning and during the day in 6 healthy volunteers. The HR response was fitted to an exponential hyperbolic sine function: HR= alpha*e(-beta*t) *sinh(omega*t)+gamma. In this equation, the beta/omega ratio was inversely correlated with the intensity of the HR response. HF power was determined using a recently developed algorithm with high time-resolution power. There were no significant differences in HR, HF power or systolic blood pressure (BP) pressure before exercise between early morning and daytime exercise with either the 50 or 100 watt loads. During exercise, there were no significant differences in maximal HR or maximal systolic BP between early morning and daytime exercise with either 50 or 100 watt loads. For high-load exercise, the beta/omega ratio was significantly lower in early morning exercise (mean +/- SD, 0.945 +/- 0.02) than in daytime exercise (0.987 +/- 0.03). Similarly, for 100 watt exercise, HF power of HR variability was significantly lower in early morning exercise (0.94 +/- 0.52 msec/Hz 1/2) than in daytime exercise (1.26 +/- 0.74 msec/Hz 1/2). In conclusion, the present study demonstrated that a lower beta/omega ratio in the HR response was associated with lower HF power of HR variability in early morning high-load exercise compared to that in daytime exercise, indicating that the heart rate responded more intensely to early morning exercise than to daytime exercise with a high load due, at least partly, to pronounced suppression of parasympathetic nerve activity.


Subject(s)
Circadian Rhythm/physiology , Exercise/physiology , Heart Rate/physiology , Adult , Blood Pressure/physiology , Exercise Test/methods , Exercise Test/statistics & numerical data , Humans , Linear Models , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...