Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 73
Filter
1.
Expert Rev Clin Immunol ; 17(7): 737-759, 2021 07.
Article in English | MEDLINE | ID: mdl-34015983

ABSTRACT

Introduction: During the COVID-19 pandemic thyroid gland alteration/dysfunction has been emerged as a possible endocrine complication. The present review is focused on inflammatory and autoimmune thyroid complications triggered by SARS-CoV-2 infection by searching through databases like MEDLINE and Scopus up to April 2021.Areas covered: Beside the occurrence of 'non-thyroidal illness' in severe clinical conditions, alterations of thyroid function and structure may occur during COVID-19 as a consequence of either direct or indirect effects of SARS-CoV-2 infection on the gland. On the one hand, SARS-CoV-2 uses ACE2 as a receptor to infect the host cells and ACE2 is highly expressed by follicular thyroid cells. On the other hand, COVID-19 is associated with a systemic inflammatory and immune response, involving Th1/Th17/Th2 lymphocytes and proinflammatory cytokines, which resembles the immune activation that occurs in immune-mediated thyroid diseases. COVID-19-related thyroid disorders include destructive thyroiditis and onset or relapse of autoimmune thyroid disorders, leading to a broad spectrum of thyroid dysfunction ranging from thyrotoxicosis to hypothyroidism, that may worsen COVID-19 clinical course and affect prognosis.Expert opinion: Physicians should be aware of the possible occurrence of thyroid dysfunction during and after SARS-CoV-2 infection. Further longitudinal studies are warranted to evaluate potential long-term sequelae.


Subject(s)
Autoimmune Diseases/virology , COVID-19/complications , Thyroid Diseases/virology , Autoimmune Diseases/immunology , COVID-19/immunology , Humans , SARS-CoV-2/immunology , Thyroid Diseases/immunology
2.
Clin Transl Sci ; 14(3): 898-907, 2021 05.
Article in English | MEDLINE | ID: mdl-33306235

ABSTRACT

Currently, few evidences have shown the possible involvement of autoimmunity in patients affected by coronavirus disease 2019 (COVID-19). In this study, we elucidate whether severe acute respiratory syndrome coronavirus disease 2 (SARS-CoV-2) stimulates autoantibody production and contributes to autoimmunity activation. We enrolled 40 adult patients (66.8 years mean age) admitted to Alessandria Hospital between March and April 2020. All the patients had a confirmed COVID-19 diagnosis and no previously clinical record of autoimmune disease. Forty blood donors were analyzed for the same markers and considered as healthy controls. Our patients had high levels of common inflammatory markers, such as C reactive protein, lactate dehydrogenase, ferritin, and creatinine. Interleukin-6 concentrations were also increased, supporting the major role of this interleukin during COVID-19 infection. Lymphocyte numbers were generally lower compared with healthy individuals. All the patients were also screened for the most common autoantibodies. We found a significant prevalence of antinuclear antibodies, antineutrophil cytoplasmic antibodies, and ASCA immunoglobulin A antibodies. We observed that patients having a de novo autoimmune response had the worst acute viral disease prognosis and outcome. Our results sustain the hypothesis that COVID-19 infection correlates with the autoimmunity markers. Our study might help clinicians to: (a) better understand the heterogeneity of this pathology and (b) correctly evaluate COVID-19 clinical manifestations. Our data explained why drugs used to treat autoimmune diseases may also be useful for SARS-CoV-2 infection. In addition, we highly recommend checking patients with COVID-19 for autoimmunity markers, mainly when deciding on whether to treat them with plasma transfer therapy. Study Highlights WHAT IS THE CURRENT KNOWLEDGE ON THE TOPIC? ☑ Recent data sustain the idea that autoimmune phenomena exist in patients with coronavirus disease 2019 (COVID-19), but other investigations are necessary to define the possible link between severe acute respiratory syndrome coronavirus disease 2 (SARS-CoV-2) infection and autoimmune disease onset. WHAT QUESTION DID THIS STUDY ADDRESS? ☑ In this monocentric study, we demonstrated how SARS-CoV-2 infection could be associated with an autoimmune response and development of autoantibodies. WHAT DOES THIS STUDY ADD TO OUR KNOWLEDGE? ☑ Patients with COVID-19 having an increased level of inflammatory markers and strong autoantibodies positivity (i.e., antinuclear antibodies and antineutrophil cytoplasmic antibodies) presented the worst clinical outcome. HOW MIGHT THIS CHANGE CLINICAL PHARMACOLOGY OR TRANSLATIONAL SCIENCE? ☑ These results suggest that the drugs normally used to treat autoimmune diseases should also be considered during SARS-CoV-2, improving public health. In addition, before starting a transfer plasma therapy, it is important to also evaluate the autoimmunity conditions of the patients with COVID-19. Transferring antibodies or trying to neutralize them should be done with precaution. It is possible that the risk of developing or increasing the autoimmune response may enhance.


Subject(s)
Autoimmunity , COVID-19/immunology , SARS-CoV-2 , Adult , Aged , Aged, 80 and over , Autoantibodies/blood , Autoimmune Diseases/etiology , COVID-19/diagnostic imaging , Female , Humans , Inflammation/etiology , Male , Middle Aged
4.
Auto Immun Highlights ; 11(1): 1, 2020 Jan 07.
Article in English | MEDLINE | ID: mdl-32127047

ABSTRACT

Receptor autoimmunity is one of the ways in which autoimmune diseases appear in humans. Graves' disease, myasthenia gravis, idiopathic membranous nephropathy, and autoimmune acute encephalitis are the major autoimmune diseases belonging to this particular group. Receptor autoimmune disease are dependent on the presence of autoantibodies directed against cell-surface antigens, namely TSH receptor in thyrocytes, acetylcholine receptor in neuromuscular junction, phospholipase 2 receptor in podocytes, and NMDA receptor in cortical neurons. In this article we outline the distinctive features of receptor autoimmunity and the specific relationship between the autoimmunology laboratory and the presence/concentration of autoantibodies. Some immunological features distinguish receptor autoimmunity. Anti-receptor autoantibody pathologies are considered T cell-dependent, B-cell-mediated autoimmune disorders: the knowledge about the presence of circulating and/or localized autoantibodies to target organs and identification of autoantigens involved in the autoimmune reaction is of paramount importance. Due to the close correlation between the concentration of anti-receptor autoantibodies, the autoimmune target of some cell-surface receptors and the intensity of symptoms, the measurement of these immunoglobulins has become central to diagnose autoimmune diseases in all affected patients, not just in clinically dubious cases. The measurement of autoantibodies is also relevant for differential diagnosis of autoimmune and non-autoimmune forms with similar symptoms. From the methodological point of view, quantitative immunoassay methods of measurement should be preferred over semi-quantitative ones, for the capacity of the first class of methods to define precisely the reference ranges and decision levels overcoming the measurement uncertainty of semi-quantitative methods.

5.
Clin Chem Lab Med ; 58(10): 1663-1672, 2020 09 25.
Article in English | MEDLINE | ID: mdl-31927515

ABSTRACT

Background The comparability of thyroid-stimulating hormone (TSH) results cannot be easily obtained using SI-traceable reference measurement procedures (RPMs) or reference materials, whilst harmonization is more feasible. The aim of this study was to identify and validate a new approach for the harmonization of TSH results. Methods Percentile normalization was applied to 125,419 TSH results, obtained from seven laboratories using three immunoassays (Access 3rd IS Thyrotropin, Beckman Coulter Diagnostics; Architect System, Abbott Diagnostics and Elecsys, Roche Diagnostics). Recalibration equations (RCAL) were derived by robust regressions using bootstrapped distribution. Two datasets, the first of 119 EQAs, the second of 610, 638 and 639 results from Access, Architect and Elecsys TSH results, respectively, were used to validate RCAL. A dataset of 142,821 TSH values was used to derive reference intervals (RIs) after applying RCAL. Results Access, Abbott and Elecsys TSH distributions were significantly different (p < 0.001). RCAL intercepts and slopes were -0.003 and 0.984 for Access, 0.032 and 1.041 for Architect, -0.031 and 1.003 for Elecsys, respectively. Validation using EQAs showed that before and after RCAL, the coefficients of variation (CVs) or among-assay results decreased from 10.72% to 8.16%. The second validation dataset was used to test RCALs. The median of between-assay differences ranged from -0.0053 to 0.1955 mIU/L of TSH. Elecsys recalibrated to Access (and vice-versa) showed non-significant difference. TSH RI after RCAL resulted in 0.37-5.11 mIU/L overall, 0.49-4.96 mIU/L for females and 0.40-4.92 mIU/L for males. A significant difference across age classes was identified. Conclusions Percentile normalization and robust regression are valuable tools for deriving RCALs and harmonizing TSH values.


Subject(s)
Immunoassay/methods , Thyrotropin/blood , Calibration , Clinical Laboratory Information Systems , Humans , Reference Values , Reproducibility of Results , Thyrotropin/standards
6.
Clin Chem Lab Med ; 57(2): 259-267, 2018 12 19.
Article in English | MEDLINE | ID: mdl-30016276

ABSTRACT

Background The aims of this study were: (1) to calculate reliable thyroid stimulating hormone (TSH) reference intervals using laboratory databases; (2) to evaluate the relationship between TSH, sex and age values in different large Italian populations. Methods The TSH values stored in the laboratory information system of clinical laboratories of four Italian city hospitals, including 146,801 TSH measurements (with the respective age and sex data of individuals) were taken in consideration. Assuming a log-normal distribution, to log-transformed TSH values were applied the Dixon's iterative principle in order to exclude the outliers. At the end of this iterative process 142,821 log-transformed TSH results remained. The four clinical laboratories measured serum TSH concentrations using the same TSH immunoassay method (Access TSH 3rd IS, using UniCel DxI platform). Results The TSH reference interval calculated in the present study (0.362-5.280 mIU/L) is similar to that suggested by the manufacturer for the Access TSH 3rd IS assay (0.45-5.33 mIU/L). TSH values in females were significantly higher than in males (females: mean=2.06 mIU/L; standard deviation [SD]=1.26 mIU/L; n=101,243; males: mean=1.92 mIU/L; SD=1.19 mIU/L; n=41,578; p<0.0001). Moreover, a negative linear relationship was observed between TSH throughout all interval age values (from 0 to 105 years). Conclusions The results of the present multicenter study confirm that data mining techniques can be used to calculate clinically useful reference intervals for TSH. From a pathophysiological point of view, our results suggest that some Northern populations of Italy might still suffer some harmful effects on the thyroid gland due to mild to moderate iodine intake deficiency. Specific clinical trials are needed to confirm these results.


Subject(s)
Thyrotropin/blood , Thyrotropin/standards , Adult , Female , Humans , Italy , Male , Middle Aged , Reference Standards
8.
Clin Chem Lab Med ; 56(11): 1936-1944, 2018 10 25.
Article in English | MEDLINE | ID: mdl-29746252

ABSTRACT

BACKGROUND: The total testosterone (T) cutoffs clinically adopted to define late-onset hypogonadism (LOH) do not consider the differences that exist between different analytical platforms, nor do they consider the body mass index (BMI) or age of the patient. We aimed at providing method, age and BMI-specific normal values for total T in European healthy men. METHODS: A total of 351 eugonadal healthy men were recruited, and total T was measured with four automated immunometric assays (IMAs): ARCHITECT i1000SR (Abbott), UniCel DxI800 (Beckman Coulter), Cobas e601 (Roche), IMMULITE 2000 (Siemens) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Reference ranges (RRs) were calculated for each method. RESULTS: Passing and Bablok regression analysis and Bland-Altman plot showed an acceptable agreement between Abbott and LC-MS/MS, but a poor one between LC-MS/MS and the other IMAs. Age-specific T concentrations in non-obese (BMI <29.9 kg/m2) men were greater than in all men. The total T normal range, in non-obese men aged 18-39 years, measured with LC-MS/MS was 9.038-41.310 nmol/L. RRs calculated with LC-MS/MS statistically differed from the ones calculated with all individual IMAs, except Abbott and among all IMAs. Statistically significant differences for both upper and lower reference limits between our RRs and the ones provided by the manufacturers were also noticed. CONCLUSIONS: We calculated normal ranges in a non-obese cohort of European men, aged 18-39 years, with four commercially available IMAs and LC-MS/MS and found statistically significant differences according to the analytical method used. Method-specific reference values can increase the accuracy of LOH diagnosis and should be standardly used.


Subject(s)
Immunoassay/methods , Testosterone/analysis , Adolescent , Adult , Body Mass Index , Chromatography, High Pressure Liquid/standards , Healthy Volunteers , Humans , Immunoassay/standards , Male , Reagent Kits, Diagnostic , Reference Values , Tandem Mass Spectrometry/standards , Testosterone/standards , Young Adult
9.
Auto Immun Highlights ; 9(1): 3, 2018 Feb 12.
Article in English | MEDLINE | ID: mdl-29435670

ABSTRACT

PURPOSE: Thyrotropin receptor (TSHR) autoantibodies (TRAbs) are a hallmark of Graves' disease (GD). The aim of this study was to evaluate the diagnostic accuracy of a new third generation automatic fluorescence enzyme immunoassay for TRAb measurement in GD, in comparison with two current IMAs. METHODS: Sera of 439 subjects (57 patients with untreated GD, 34 with treated GD, 15 with GD and Graves' orbitopathy, 52 with multinodular non-toxic goiter, 86 with Hashimoto's thyroiditis, 20 with toxic adenoma or toxic multinodular goiter, 55 with non-thyroid autoimmune diseases and 120 normal controls) were tested for TRAbs with the ELiA™ anti-TSH-R assay (ThermoFischer Scientific, Uppsala, Sweden), the TRAK™ RIA, Brahms (Thermo Scientific, Hennigsdorf, Germany) and the Immulite™ TSI assay (Siemens Healthcare, Llanberis, UK). RESULTS: Sensitivity and specificity of the ELiA™ anti-TSH-R assay, TRAK™ RIA and Immulite™ TSI assay were 94.7% and 99.6, 100 and 98.2%, 100 and 98.2%, respectively. Spearman's coefficient and Passing-Bablok regression showed a satisfactory correlation between EliA™ and TRAK™ [rho: 0.925; 95% CI: 0.883-0-953. Intercept: - 0.875 (95% CI: - 2.411 to 0.194); slope: 1.086 (95% CI: 0.941 to 1.248)], and between ELiA™ and TSI™ [rho: 0.947; 95% CI: 0.912 0.969. intercept: 1.085 (95% CI: 0.665 to 2.116); slope 1.315 (95% CI:1.116 to 1.700)]. CONCLUSIONS: The diagnostic performance of ELiA™-TSH-R assay is comparable to that of some current TRAb assays. It may be adopted into clinical practice for the differential diagnosis of hyperthyroidism, to screen for transient hyperthyroidism, and to monitor disease activity and treatment effects.

10.
Clin Chem Lab Med ; 55(1): 58-64, 2017 Jan 01.
Article in English | MEDLINE | ID: mdl-27331310

ABSTRACT

BACKGROUND: Thyroid stimulating hormone (TSH) receptor autoantibodies (TRAb) are pathogenetic and diagnostic hallmarks of Graves' disease (GD). Three varieties of TRAb have been described: stimulating (S-TRAb), blocking (B-TRAb), and apoptotic (A-TRAb) autoantibodies. Very recently, the first immunoassay method (Immulite TSI assay, Siemens Healthcare Diagnostics) declared to measure serum S-TRAb concentration, has been made available in an automated commercial platform. The aim of the study was to evaluate the ability of this new test to identify patients suffering from GD, in comparison with two current IMA methods for total TSH receptor autoantibodies (T-TRAb) measurement. METHODS: Sera of 383 subjects [72 patients with untreated GD, 55 patients with autoimmune thyroiditis (AIT), 36 patients with multinodular non-toxic goiter, 100 patients with other non-thyroid autoimmune diseases (NTAD) and 120 healthy subjects (HS)] were evaluated. RESULTS: The threshold obtained by receiver operating characteristic (ROC) analysis was 0.54 IU/L, very similar to that proposed by the manufacturer (0.55 IU/L). Thyroid-stimulating immunoglobulins (TSI) were positive in all GD patients and negative in all but three controls (clinical sensitivity and specificity of 100% and 98.7%, respectively). Passing and Bablok regression analysis and Bland-Altman plot showed an acceptable agreement between TSI Immulite assay and other two immunoassay methods (Cobas/Elecsys, Roche and TRAK RIA, BRAHMS Thermo Scientific). CONCLUSIONS: The diagnostic performance of fully automated Immulite TSI assay in GD patients is at least comparable to that of current TRAb immunoassays (IMAs) suggesting the possibility of including such assay in rapid and cost-saving diagnostic and monitoring algorithms. However, our results do not provide full evidence that this assay is specific for S-TRAb only, and future studies comparing Immulite TSI assay to stimulating activity are required.


Subject(s)
Autoantibodies/blood , Graves Disease/blood , Immunoassay/standards , Receptors, Thyrotropin/blood , Automation , Female , Graves Disease/diagnosis , Humans , Male
11.
Clin Chem Lab Med ; 55(7): 914-925, 2017 Jun 27.
Article in English | MEDLINE | ID: mdl-27802177

ABSTRACT

Different imaging tools, circulating endocrine markers, and fine-needle aspiration (FNA) cytology are of great importance in the diagnosis and follow-up of different thyroid and parathyroid diseases. Sometimes, however, they are conflicting or inconclusive: interestingly, measuring endocrine markers (i.e. thyroglobulin, calcitonin, parathyroid hormone) in fluids from FNA proved to be a very useful complementary diagnostic tool in such cases. The determination of endocrine markers in fluids other than serum/plasma has been developed in the last years. Although studies have reported overall satisfactory results, a good standardization of procedures has not yet been reached, and further efforts should be made in order to better define pre-analytical, analytical, and post-analytical aspects. Here we reviewed critically the literature on the measurement of FNA endocrine markers, focusing on laboratory issues, such as preparation of the sample, choice of solution, and technical features of determination of these markers. Indeed, information for use of FNA-Tg, FNA-CT, and FNA-PTH in clinical practice was also provided.


Subject(s)
Biopsy, Fine-Needle , Calcitonin/analysis , Clinical Chemistry Tests/methods , Parathyroid Hormone/analysis , Thyroglobulin/analysis , Humans
12.
Clin Rev Allergy Immunol ; 53(1): 68-77, 2017 Aug.
Article in English | MEDLINE | ID: mdl-27498835

ABSTRACT

Standardization and harmonization are complementary tools to achieve higher testing quality in laboratory medicine. Both are of great relevance and are strongly needed in autoimmune diagnostics, due to the impressive advance in basic research and technological development observed in this diagnostic field in recent years that has led to the introduction of many new tests and new analytical methods. It is, therefore, essential that this strong innovative thrust is translated into clinical practice in a coordinated way to avoid confusion and the risk of potentially harmful errors for the patient. However, while standardization of antibody assays is a very complex task, harmonization of procedures and behaviors is a more feasible target and should necessarily include all the phases of the total testing process-in the pre-analytical phase, appropriateness of test requests, harmonization of autoantibody terminology, and adoption of uniform nomenclature for laboratory tests; in the analytical phase, harmonization of measurements, and sharing of test profiles and diagnostic algorithms; and in the post-analytical phase, harmonization of data reporting, and criteria for interpreting immunoserological results, especially harmonization of units, reference intervals, decision limits, and definition and notification of critical values. We here provide and discuss some examples of harmonization initiatives related to anti-nuclear antibodies, TSH receptor, and anti-thyroid peroxidase antibodies and to antibodies associated with autoimmune hepatitis and with celiac disease. These initiatives could be the starting steps to achieve a wider consensus and a closer interaction among stakeholders in the path of autoimmune diagnostics harmonization to enhance clinical effectiveness and provide greater patient safety.


Subject(s)
Autoantibodies/immunology , Autoimmune Diseases/diagnosis , Autoimmune Diseases/immunology , Autoimmunity , Immunoassay/standards , Antibodies, Antinuclear/blood , Antibodies, Antinuclear/immunology , Autoantibodies/blood , Autoimmune Diseases/blood , Celiac Disease/blood , Celiac Disease/diagnosis , Celiac Disease/immunology , Hepatitis, Autoimmune/blood , Hepatitis, Autoimmune/diagnosis , Hepatitis, Autoimmune/immunology , Humans , Immunoassay/methods , Receptors, Thyrotropin/immunology , Reference Standards
13.
Clin Biochem ; 49(16-17): 1227-1231, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27521620

ABSTRACT

OBJECTIVES: Pleural effusion recognizes heterogeneous etiology and pathogenesis and requires invasive diagnostic procedures. Usually, after pleural fluid analysis, 30-50% of patients with malignant pleural effusion exhibit negative pleural cytology, and the sensitivity of image-guided pleural needle-aspiration biopsy ranges between 60% and 70%. With the aim of differentiating between benign (BPE) and malignant (MPE) pleural effusions, several tumor markers have been assayed in the pleural fluid and the majority of studies focus on pleural carcinoembryonic antigen (p-CEA). The aims of this study were to evaluate (i) the diagnostic accuracy of p-CEA of patients with pleural effusions undergoing video-assisted thoracoscopic surgery (VATS) for diagnostic purpose, (ii) the relationship between p-CEA and serum CEA (s-CEA), and (iii) the usefulness of the p-CEA/s-CEA ratio in the diagnosis of malignant pleural effusions (MPE). DESIGN & METHODS: We prospectively enrolled in the study 134 consecutive patients with pleural effusions, scheduled for having VATS and biopsy. The final diagnosis, based on histopathology of the VATS-guided specimens, was available for all patients. p-CEA and s-CEA was assayed with a chemiluminescence immunoassay method (CLIA), applied on the Maglumi 2000 Plus automated platform (SNIBE, Shenzen, China). RESULTS: The sensitivity and accuracy of p-CEA was significantly higher than that of pleural cytology at the same specificity comparing BPE with MPE and BPE with non-small lung cancer. The sensitivity of p-CEA and PC together reached 100% (BPE vs. NSCLC) and 91.5% (BPE vs. MPE excluding mesothelioma), respectively. CONCLUSIONS: The p-CEA measurement in patients with pleural effusion of uncertain etiology is a safe and cost-effective procedure, everywhere easily available, which may help clinicians in selecting patients for further evaluations. An elevated p-CEA level in a patient with pleural effusion and negative pleural cytology suggests the need of more invasive procedure (e.g. VATS-guided biopsies), whilst low p-CEA may support a follow-up.


Subject(s)
Biomarkers/metabolism , Carcinoembryonic Antigen/metabolism , Pleura/immunology , Pleural Effusion/immunology , Humans , Pleural Effusion/etiology , Pleural Effusion/pathology , Predictive Value of Tests
14.
Clin Chim Acta ; 460: 227-30, 2016 Sep 01.
Article in English | MEDLINE | ID: mdl-27404457

ABSTRACT

BACKGROUND: The skeleton is the most common site of metastasis for breast cancer and the periodic measurement of circulating bone turnover markers (BTMs) can be useful. The aim of this study was to prospectively evaluate the diagnostic accuracy of a panel of BTMs in the early detection of bone metastases (BMs). METHODS: We reviewed the medical records of 297 postmenopausal women with early stage luminal-type invasive ductal carcinoma (IDC). Twenty-six patients who developed isolated BMs during follow-up and 24 randomly selected controls were studied. The two groups were matched according to age, final disease staging, and follow-up. All patients underwent periodic measurement of total and bone-specific (BSAP) alkaline phosphatase, CTX, ICTP, osteocalcin, NTX, PINP, and TRACP5b. RESULTS: Only BSAP, CTX, PINP, and TRACP5b were significantly (p<0.05) associated with the group, and the logistic regression analysis excluded CTX from the model. The AUC (ROC curve) for TRACP5b alone, which was the most accurate marker, and for the combination of BSAP+PINP+TRACP5b was 0.784 (95% CI: 0.651-0.916) and 0.889 (95% CI: 0.798-0.981), respectively. CONCLUSION: According to our results, the measurement of these three markers together should be performed in all postmenopausal patients with luminal-type IDC, when an early diagnosis of BMs is required.


Subject(s)
Bone Neoplasms/secondary , Bone Remodeling , Breast Neoplasms/pathology , Aged , Alkaline Phosphatase/analysis , Biomarkers, Tumor/analysis , Bone Neoplasms/diagnosis , Carcinoma, Ductal, Breast/pathology , Case-Control Studies , Female , Humans , Logistic Models , Middle Aged , Peptide Fragments/analysis , Postmenopause , Procollagen/analysis , Prospective Studies , Tartrate-Resistant Acid Phosphatase/analysis
15.
Auto Immun Highlights ; 7(1): 9, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27423928

ABSTRACT

Reflex tests are widely used in clinical laboratories, for example, to diagnose thyroid disorders or in the follow-up of prostate cancer. Reflex tests for antinuclear antibodies (ANA) have recently gained attention as a way to improve appropriateness in the immunological diagnosis of autoimmune rheumatic diseases and avoid waste of resources. However, the ANA-reflex test is not as simple as other consolidated reflex tests (the TSH-reflex tests or the PSA-reflex tests) because of the intrinsic complexity of the ANA test performed by the indirect immunofluorescence method on cellular substrates. The wide heterogeneity of the ANA patterns, which need correct interpretation, and the subsequent choice of the most appropriate confirmatory test (ANA subserology), which depend on the pattern feature and on clinical information, hinder any informatics automation, and require the pathologist's intervention. In this review, the Study Group on Autoimmune Diseases of the Italian Society of Clinical Pathology and Laboratory Medicine provides some indications on the configuration of the ANA-reflex test, using two different approaches depending on whether clinical information is available or not. We further give some suggestions on how to report results of the ANA-reflex test.

16.
Med Chem ; 12(3): 261-7, 2016.
Article in English | MEDLINE | ID: mdl-27056135

ABSTRACT

For decades, adjuvant hormonal therapy has become the standard treatment of patients with estrogen receptor-positive breast cancer. Currently, the drugs available are GnRH agonists, selective estrogen receptor modulators, and aromatase inhibitors. The use of GnRH agonists represents a potentially reversible treatment that can restore ovarian function after chemotherapy. In premenopausal women, systemic therapy based on selective estrogen receptor modulators administration (e.g., tamoxifen) usually represents the standard adjuvant treatment. There are not sufficient data to recommend the routine addition of GnRH agonists to other endocrine therapies. In postmenopausal women, the disease-free survival was significantly prolonged in patients treated with aromatase inhibitor compared with those treated with tamoxifen, but the survival benefit was modest. Better results were obtained when the two drugs were administered sequentially. According to the ASCO guidelines, after 5 years of tamoxifen treatment, either tamoxifen or aromatase inhibitors therapy should be suggested for an additional 5 years. Unfortunately, most adverse events are consistent with estrogen deprivation and are common to all therapies, and the cumulative toxicity causes discontinuation and nonadherence to therapy in up to 50% of patients. Switching tamoxifen to an aromatase inhibitor may reduce adverse event incidence. Molecular-targeted therapy is useful in patients with advanced, relapsed or hormonal therapy-resistant tumors, usually as second- or third-line treatment. These drugs are usually added to aromatase inhibitors; however, currently, they have not yet been used in patients with early breast cancer.


Subject(s)
Antineoplastic Agents, Hormonal/therapeutic use , Breast Neoplasms/drug therapy , Antineoplastic Agents, Hormonal/adverse effects , Antineoplastic Agents, Hormonal/chemistry , Breast Neoplasms/pathology , Chemotherapy, Adjuvant , Humans , Molecular Structure , Neoplasm Staging
17.
Autoimmun Rev ; 15(5): 466-76, 2016 May.
Article in English | MEDLINE | ID: mdl-26849953

ABSTRACT

Hashimoto's encephalopathy (HE) is a rare not well understood, progressive and relapsing multiform disease, characterized by seizures, movement disorders, subacute cognitive dysfunction, psychiatric symptoms and responsiveness to steroid therapy. The disorder is generally associated with thyroid diseases and the most common feature is the presence of anti-thyroperoxidase antibodies (TPOAb). Patients are usually euthyroid or mildly hypothyroid at presentation. All age groups can be affected. The pathophysiology is still unclear, especially the link between elevated serum TPOAb and the encephalopathy. Most reported cases occurred in women and girls. Unspecific symptoms, non-pathognomonic laboratory neurophysiology and neuroimaging features make its diagnosis a real challenge for clinicians. The case of a 16 year old boy, with a clinical picture of HE associated with hypothyroidism, demonstrating an excellent response to high dose steroids is presented together with a systematic review of the literature.


Subject(s)
Encephalitis/immunology , Hashimoto Disease/immunology , Autoantigens/immunology , Biomarkers/analysis , Cognition Disorders/etiology , Diagnosis, Differential , Encephalitis/therapy , Hashimoto Disease/therapy , Humans , Iodide Peroxidase/immunology , Iron-Binding Proteins/immunology , Steroids/therapeutic use , Treatment Outcome
18.
Anticancer Res ; 36(1): 13-9, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26722023

ABSTRACT

Liver and pulmonary metastases (PMs) are relatively common in patients with colorectal cancer. The majority of metastases are suitable for surgical resection, and the effectiveness of metastasectomy is usually assessed based on overall survival (OS). Metastasectomy provides a mean 5-year OS rate of approximately 50%, but the results are better in patients with liver metastases compared to those with PMs. Unfortunately, the presence of bilateral or multiple PMs represents a relative contraindication to surgical metastasectomy. Unresectable PMs can be safely treated with percutaneous radiofrequency ablation or radiotherapy, but the reported results vary widely. Several clinical prognostic factors affecting OS after metastasectomy have been reported, such as number of PMs, hilar or mediastinal lymph node involvement, disease-free interval, age and gender, resection margins, size of the metastases, neoadjuvant chemotherapy administration, and histological type of the primary cancer. The accurate evaluation of all clinical prognostic factors, circulating and immunohistochemical markers, and the study of gene mutational status will lead to a more accurate selection of patients scheduled to metastasectomy, with the aim of improving outcome.


Subject(s)
Catheter Ablation , Colorectal Neoplasms/pathology , Lung Neoplasms/secondary , Metastasectomy , Pneumonectomy , Biomarkers, Tumor/genetics , Catheter Ablation/adverse effects , Catheter Ablation/mortality , Colorectal Neoplasms/genetics , Colorectal Neoplasms/mortality , Colorectal Neoplasms/therapy , Disease-Free Survival , Humans , Lung Neoplasms/genetics , Lung Neoplasms/mortality , Lung Neoplasms/therapy , Metastasectomy/adverse effects , Metastasectomy/mortality , Neoplasm Staging , Patient Selection , Pneumonectomy/adverse effects , Pneumonectomy/mortality , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
19.
Clin Chim Acta ; 452: 61-5, 2016 Jan 15.
Article in English | MEDLINE | ID: mdl-26519836

ABSTRACT

BACKGROUND: The determination of the upper reference limit (URL) for thyroid peroxidase autoantibodies (TPOAbs) is a contentious issue, because of the difficulty in defining the reference population. The aim of this study was to establish the URL (eURL) for TPOAbs, according to the National Academy of Clinical Biochemistry (NACB) guidelines and to compare them with those obtained in a female counterpart, by the use of six commercial automated platforms. METHODS: 120 healthy males and 120 healthy females with NACB-required characteristics (<30years, TSH between 0.5 and 2.0mIU/L, normal thyroid ultrasound, without personal/family history of thyroid and non-thyroid autoimmune diseases) were studied. Sera were analyzed for TPOAbs concentration using six immunoassay methods applied in automated analyzers: Advia Centaur XP (CEN), Siemens Healthcare Diagnostics; Maglumi 2000 Plus, Shenzen New Industries Biomedical Engineering; Architect ci4100, Abbott; Cobas e411 (COB) Roche Diagnostics; Unicel DxI (UNI) and Lumipulse G1200, Fujirebio. RESULTS: Within each method, TPOAbs values had a high degree of dispersion and the eURLs were lower than those stated by the manufacturer. A statistically significant difference (p<0.05) between medians of males and females was observed only for COB and for UNI. However, the comparison of the male and female proportions positive for TPOAbs using the eURL of the counterpart, showed the lack of clinical significance of the above differences (Chi-square test, p>0.05). CONCLUSIONS: Despite the analytical harmonization, the wide dispersion of the results and the differences of the eURLs between methods suggest the need of further studies focusing on TPO antigen preparations as the possible source of variability between different assays. In addition, the lack of clinical significant difference between males and females, in terms of TPOAb eURLs, confirms the suitability of the NACB recommendations.


Subject(s)
Autoantibodies/blood , Autoantibodies/immunology , Autoantigens/immunology , Immunoassay/methods , Iodide Peroxidase/immunology , Iron-Binding Proteins/immunology , Adult , Automation , Female , Humans , Male , Reference Values , Sex Characteristics
20.
Med Chem ; 12(3): 285-9, 2016.
Article in English | MEDLINE | ID: mdl-26567615

ABSTRACT

The prognosis of breast cancer is strongly influenced by the stage of the disease; therefore, it is essential that breast cancer lesions be diagnosed at the earliest stages. There is an urgent need to identify different biomarkers with a high accuracy for the early detection of this cancer to facilitate clinical management of the disease. A wide number of substances named serum tumor markers can be detected in the serum of patients with breast cancer, including tumor-associated proteins, cytokines, stimulating or inhibiting factors, autoantibodies to antigen tumor-associated substances and miRNAs. Despite ASCO and NACB recommendations, the routine use of breast cancer tumor markers by a significant proportion of oncologists is common, particularly after primary treatment of early tumors. The new promising circulating markers are HER2/neu, Trx 1, CSF1, autoantibodies against these tumor-associated antigens, and miRNAs, which are non-coding RNA molecules that regulate the translation of mRNA and control a number of biological processes, including oncogenic cells proliferation. The expression of single miRNA results in a miRNA signature, and is considered a potential biomarker for early breast cancer. However, additional studies are needed to identify its real usefulness.


Subject(s)
Biomarkers, Tumor/blood , Breast Neoplasms/blood , Breast Neoplasms/diagnosis , Breast Neoplasms/pathology , Female , Humans , Neoplasm Staging
SELECTION OF CITATIONS
SEARCH DETAIL
...