Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
Clin Cardiol ; 44(7): 932-937, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34076282

ABSTRACT

BACKGROUND: Rapid diagnosis of heart failure (HF) in acutely dyspneic patients can be challenging for emergency department (ED) physicians. HYPOTHESIS: Cardiac output (CO) change with sublingual nitroglycerin (NTG) could be helpful in the diagnosis of HF in patients with acute undifferentiated dyspnea. MATERIALS AND METHODS: A prospective study of patients >18 years admitted to the ED for acute dyspnea. Using thoracic bioimpedance, we measured CO change at baseline and after sublingual administration of 0.6 mg of NTG. HF was defined on the basis of clinical examination, pro-brain natriuretic peptide levels, and echocardiographic findings. Diagnostic performance of delta CO was calculated by sensitivity, specificity, likelihood ratio and receiver operating characteristic (ROC) curve. RESULTS: This study included 184 patients with mean age of 64 years. Baseline CO was comparable between the HF group and the non-HF group. At its best cutoff (29%), delta CO showed good accuracy in the diagnosis of HF with a sensitivity, specificity, positive and negative likelihood ratios of 80%, 44%, 57%, and 66% respectively. Area under ROC curve was 0.701 [95% CI 0.636-0.760]. The decrease of CO with sublingual NTG was significantly higher in patients with HFpEF compared with those with HFrEF. Multivariate analysis, showed that delta CO was an independent factor associated with HF diagnosis [OR 0.19 (95% CI 0.11-0.29); p < .001]. CONCLUSIONS: Our study showed that CO change with sublingual nitroglycerin is a simple tool that may be helpful for the diagnosis of HF in ED patients with undifferentiated dyspnea.


Subject(s)
Heart Failure , Acute Disease , Dyspnea/diagnosis , Dyspnea/etiology , Emergency Service, Hospital , Heart Failure/diagnosis , Humans , Natriuretic Peptide, Brain , Nitroglycerin , Prospective Studies , Sensitivity and Specificity , Stroke Volume
2.
Ultrasound J ; 13(1): 5, 2021 Feb 09.
Article in English | MEDLINE | ID: mdl-33559777

ABSTRACT

BACKGROUND: Ultrasonographic B-lines have recently emerged as a bedside imaging tool for the differential diagnosis of acute dyspnea in the Emergency Department (ED). However, despite its simplicity, LUS has not fully penetrated emergency department. This study aimed to assess the accuracy and reproducibility of ultrasonographic B-lines performed by emergency medicine (EM) residents for the diagnosis of congestive heart failure (CHF) in patients admitted to ED for acute dyspnea. PATIENTS AND METHODS: This is a cross-sectional prospective study conducted between January 2016 and October 2017 including patients aged over 18 years admitted to ED for acute dyspnea. At admission, two consecutive bedside LUS study were performed by a pair of EM residents who received a 2-h course for recognition of sonographic B-lines to determine independently B-lines score and B-profile pattern. All participating sonographers were blinded to patients' clinical data. B-lines score ≥ 15 or a B-profile pattern was considered as suggestive of CHF. The final leading diagnosis was assessed by two expert sonographers, who were blinded to the residents' interpretations, based on clinical findings, chest X-ray, brain natriuretic peptide, cardiac and lung ultrasound testing. Accuracy and agreement of B-lines score and B-profile pattern were calculated. RESULTS: We included 700 patients with a mean age of 68 ± 12.6 years and a sex ratio (M/F) of 1.43. The diagnosis of CHF was recorded in 371 patients (53%). The diagnostic performance of B-lines score at a cut-off 15 and B-profile pattern was, respectively, 88% and 82.5% for sensitivity, 75% and 84% for specificity, 80% and 85% for positive predictive value, 84% and 81% for negative predictive value. The area under receiver operating characteristic curve was 0.86 [0.83-0.89] and 0.83 [0.80-0.86], respectively, for B-lines score and B-profile pattern. There was an excellent agreement between residents for the diagnosis of CHF using both scores (kappa = 0.81 and 0.85, respectively, for ordinal scale B-lines score and B-profile pattern). CONCLUSION: Lung ultrasound B-lines assessment has a good accuracy and an excellent reproducibility in the diagnosis of CHF in the hand of EM residents following a short training program. Trial registration Name of the registry: clinicaltrials.gov; Trial registration number: NCT03717779; Date of registration: October 24, 2018 'Retrospectively registered'; URL of trial registry record: clinicaltrials.gov.

SELECTION OF CITATIONS
SEARCH DETAIL
...