1.
J Appl Clin Med Phys ; 24(8): e13982, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37401002

ABSTRACT

INTRODUCTION: A system for stabilizing and monitoring eye movements during LINAC-based photon beam one single fraction stereotactic radiotherapy was developed at our Institution. This study aimed to describe the feasibility and the efficacy of our noninvasive optical localization system that was developed, tested, and applied in 20 patients treated for uveal melanoma. METHODS: Our system consisted of a customized thermoplastic mask to immobilize the head, a gaze fixation LED, and a digital micro-camera. The localization procedure, which required the active collaboration of the patient, served to monitor the eye movements during all phases of the treatment, starting from the planning computed tomography up to the administration of radiotherapy, and allowed the operators to suspend the procedure and to interact with the patient in case of large movements of the pupil. RESULTS: Twenty patients were treated with stereotactic radiosurgery (27 Gy in one fraction) for primary uveal melanoma. All patients showed a good tolerance to the treatment; until now, all patients were in local control during the follow up and one died for distant progression 6 months after radiosurgery. CONCLUSIONS: This study showed that this noninvasive technique, based on eye position control, is appropriate and can contribute to the success of LINAC-based stereotactic radiotherapy. A millimetric safety margin to the clinical target volume was adequate to take account for the organ movement. All patients treated till now showed a good local control; failures in the disease control were due to metastatic spread.


Subject(s)
Melanoma , Radiosurgery , Uveal Neoplasms , Humans , Radiosurgery/methods , Uveal Neoplasms/radiotherapy , Uveal Neoplasms/surgery , Uveal Neoplasms/pathology , Melanoma/radiotherapy , Melanoma/surgery , Melanoma/pathology , Tomography, X-Ray Computed
2.
Bioengineering (Basel) ; 10(1)2023 Jan 06.
Article in English | MEDLINE | ID: mdl-36671652

ABSTRACT

Radiomics and artificial intelligence have the potential to become a valuable tool in clinical applications. Frequently, radiomic analyses through machine learning methods present issues caused by high dimensionality and multicollinearity, and redundant radiomic features are usually removed based on correlation analysis. We assessed the effect of preprocessing-in terms of voxel size resampling, discretization, and filtering-on correlation-based dimensionality reduction in radiomic features from cardiac T1 and T2 maps of patients with hypertrophic cardiomyopathy. For different combinations of preprocessing parameters, we performed a dimensionality reduction of radiomic features based on either Pearson's or Spearman's correlation coefficient, followed by the computation of the stability index. With varying resampling voxel size and discretization bin width, for both T1 and T2 maps, Pearson's and Spearman's dimensionality reduction produced a slightly different percentage of remaining radiomic features, with a relatively high stability index. For different filters, the remaining features' stability was instead relatively low. Overall, the percentage of eliminated radiomic features through correlation-based dimensionality reduction was more dependent on resampling voxel size and discretization bin width for textural features than for shape or first-order features. Notably, correlation-based dimensionality reduction was less sensitive to preprocessing when considering radiomic features from T2 compared with T1 maps.

3.
Sci Rep ; 12(1): 10186, 2022 06 17.
Article in English | MEDLINE | ID: mdl-35715531

ABSTRACT

Radiomics is emerging as a promising and useful tool in cardiac magnetic resonance (CMR) imaging applications. Accordingly, the purpose of this study was to investigate, for the first time, the effect of image resampling/discretization and filtering on radiomic features estimation from quantitative CMR T1 and T2 mapping. Specifically, T1 and T2 maps of 26 patients with hypertrophic cardiomyopathy (HCM) were used to estimate 98 radiomic features for 7 different resampling voxel sizes (at fixed bin width), 9 different bin widths (at fixed resampling voxel size), and 7 different spatial filters (at fixed resampling voxel size/bin width). While we found a remarkable dependence of myocardial radiomic features from T1 and T2 mapping on image filters, many radiomic features showed a limited sensitivity to resampling voxel size/bin width, in terms of intraclass correlation coefficient (> 0.75) and coefficient of variation (< 30%). The estimate of most textural radiomic features showed a linear significant (p < 0.05) correlation with resampling voxel size/bin width. Overall, radiomic features from T2 maps have proven to be less sensitive to image preprocessing than those from T1 maps, especially when varying bin width. Our results might corroborate the potential of radiomics from T1/T2 mapping in HCM and hopefully in other myocardial diseases.


Subject(s)
Cardiomyopathy, Hypertrophic , Cardiomyopathy, Hypertrophic/diagnostic imaging , Heart/diagnostic imaging , Humans , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods
4.
Biomed Res Int ; 2022: 2003286, 2022.
Article in English | MEDLINE | ID: mdl-35355820

ABSTRACT

The purpose of this study was to investigate the effect of image preprocessing on radiomic features estimation from computed tomography (CT) imaging of locally advanced rectal cancer (LARC). CT images of 20 patients with LARC were used to estimate 105 radiomic features of 7 classes (shape, first-order, GLCM, GLDM, GLRLM, GLSZM, and NGTDM). Radiomic features were estimated for 6 different isotropic resampling voxel sizes, using 10 interpolation algorithms (at fixed bin width) and 6 different bin widths (at fixed interpolation algorithm). The intraclass correlation coefficient (ICC) and the coefficient of variation (CV) were calculated to assess the variability in radiomic features estimation due to preprocessing. A repeated measures correlation analysis was performed to assess any linear correlation between radiomic feature estimate and resampling voxel size or bin width. Reproducibility of radiomic feature estimate, when assessed through ICC analysis, was nominally excellent (ICC > 0.9) for shape features, good (0.75 < ICC ≤ 0.9) or moderate (0.5 < ICC ≤ 0.75) for first-order features, and moderate or poor (0 ≤ ICC ≤ 0.5) for textural features. A number of radiomic features characterized by good or excellent reproducibility in terms of ICC showed however median CV values greater than 15%. For most textural features, a significant (p < 0.05) correlation between their estimate and resampling voxel size or bin width was found. In CT imaging of patients with LARC, the estimate of textural features, as well as of first-order features to a lesser extent, is appreciably biased by preprocessing. Accordingly, this should be taken into account when planning clinical or research studies, as well as when comparing results from different studies and performing multicenter studies.


Subject(s)
Image Processing, Computer-Assisted , Rectal Neoplasms , Algorithms , Humans , Image Processing, Computer-Assisted/methods , Rectal Neoplasms/diagnostic imaging , Reproducibility of Results , Tomography, X-Ray Computed/methods
5.
J Clin Med ; 10(19)2021 Sep 22.
Article in English | MEDLINE | ID: mdl-34640332

ABSTRACT

BACKGROUND: In the context of the coronavirus disease 2019 (COVID-19) pandemic, liver-directed therapies (LDTs) may offer minimally invasive integrative tools for tumor control. Among them, selective internal radiation therapy (SIRT) represents a safe, flexible and effective treatment. Purpose of this study is to present our experience with SIRT during the first wave of COVID-19 pandemic and provide an overview of the indications and challenges of SIRT in this scenario. METHODS: We retrospectively analyzed the number of patients evaluated by Multidisciplinary Liver Tumor Board (MLTB) and who were undergoing LDTs between March and July 2020 and compared it with 2019. For patients treated with SIRT, clinical data, treatment details and the best radiological response were collected. RESULTS: Compared to 2019, we observed a 27.5% reduction in the number of patients referred to MLTB and a 28.3% decrease in percutaneous ablations; transarterial chemoembolizations were stable, while SIRT increased by 64%. The majority of SIRT patients (75%) had primary tumors, mostly HCC. The best objective response and disease control rates were 56.7% and 72.2%, respectively. CONCLUSION: The first wave of the COVID-19 pandemic was characterized by an increased demand for SIRT, which represents a safe, flexible and effective treatment, whose manageability will further improve by simplifying the treatment workflow, developing user-friendly and reliable tools for personalized dosimetry and improving interdisciplinary communication.

6.
Sci Rep ; 11(1): 19745, 2021 10 05.
Article in English | MEDLINE | ID: mdl-34611210

ABSTRACT

Radioembolization is a valuable therapeutic option in patients with unresectable intrahepatic cholangiocarcinoma. The essential implementation of the absorbed dose calculation methods should take into account also the specific tumor radiosensitivity, expressed by the α parameter. Purpose of this study was to retrospectively calculate it in a series of patients with unresectable intrahepatic cholangiocarcinoma submitted to radioembolization. Twenty-one therapeutic procedures in 15 patients were analysed. Tumor absorbed doses were calculated processing the post-therapeutic 90Y-PET/CT images and the pre-treatment contrast-enhanced CT scans. Tumor absorbed dose and pre- and post-treatment tumor volumes were used to calculate α and α3D parameters (dividing targeted liver in n voxels of the same volume with specific voxel absorbed dose). A tumor volume reduction was observed after treatment. The median of tumor average absorbed dose was 93 Gy (95% CI 81-119) and its correlation with the residual tumor mass was statistically significant. The median of α and α3D parameters was 0.005 Gy-1 (95% CI 0.004-0.008) and 0.007 Gy-1 (95% CI 0.005-0.015), respectively. Multivariate analysis showed tumor volume and tumor absorbed dose as significant predictors of the time to tumor progression. The knowledge of radiobiological parameters gives the possibility to decide the administered activity in order to improve the outcome of the treatment.


Subject(s)
Bile Duct Neoplasms/radiotherapy , Bile Ducts, Intrahepatic/pathology , Cholangiocarcinoma/radiotherapy , Embolization, Therapeutic/methods , Radiation Tolerance , Aged , Algorithms , Bile Duct Neoplasms/diagnosis , Bile Duct Neoplasms/mortality , Brachytherapy , Cholangiocarcinoma/diagnosis , Cholangiocarcinoma/mortality , Female , Humans , Male , Middle Aged , Models, Theoretical , Positron Emission Tomography Computed Tomography , Radiotherapy Dosage , Tomography, Emission-Computed, Single-Photon , Treatment Outcome , Yttrium Radioisotopes
7.
Phys Eng Sci Med ; 44(1): 23-35, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33226534

ABSTRACT

Digital breast tomosynthesis (DBT) has recently gained interest both for breast cancer screening and diagnosis. Its employment has increased also in conjunction with digital mammography (DM), to improve cancer detection and reduce false positive recall rate. Synthetic mammograms (SMs) reconstructed from DBT data have been introduced to replace DM in the DBT + DM approach, for preserving the benefits of the dual-acquisition modality whilst reducing radiation dose and compression time. Therefore, different DBT models have been commercialized and the effective potential of each system has been investigated. In particular, wide-angle DBT was shown to provide better depth resolution than narrow-angle DBT, while narrow-angle DBT allows better identification of microcalcifications compared to wide-angle DBT. Given the increasing employment of SMs as supplement to DBT, a comparison of image quality between SMs obtained in narrow-angle and wide-angle DBT is of practical interest. Therefore, the aim of this phantom study was to evaluate and compare the image quality of SMs reconstructed from 15° (SM15) and 40° (SM40) DBT in a commercial system. Spatial resolution, noise and contrast properties were evaluated through the modulation transfer function (MTF), noise power spectrum, maps of signal-to-noise ratio (SNR), image contrast, contrast-to-noise ratio (CNR) and contrast-detail (CD) thresholds. SM40 expressed higher MTF than SM15, but also lower SNR and CNR levels. SM15 and SM40 were characterized by slight different texture, and a different behavior in terms of contrast was found. SM15 provided better CD performances than SM40. These results suggest that the employment of wide/narrow-angle DBT + SM images should be optimized based on the specific image task.


Subject(s)
Calcinosis , Mammography , Early Detection of Cancer , Humans , Phantoms, Imaging , Signal-To-Noise Ratio
8.
Eur Radiol Exp ; 4(1): 38, 2020 07 07.
Article in English | MEDLINE | ID: mdl-32632827

ABSTRACT

BACKGROUND: To propose a practical and simple method to individually evaluate the average absorbed dose for digital breast tomosynthesis. METHODS: The method is based on the estimate of incident air kerma (ka,i) on the breast surface. An analytical model was developed to calculate the ka,i from the tube voltage, tube load, breast thickness, x-ray tube yield, and anode-filter combination. A homogeneous phantom was employed to simulate the breast in experimental measurements and to assess the dose-depth relationship. The ka,i values were employed to calculate the "average absorbed breast dose" (2ABD) index. Four mammographic units were used to develop and test our method under many conditions close to clinical settings. The average glandular dose (AGD) calculated following the method described by Dance et al., and the 2ABD computed through our method (i.e., from the exposure parameters) were compared in a number of conditions. RESULTS: A good agreement was obtained between the ka,i computed through our model and that measured under different clinical conditions: discrepancies < 6% were found in all conditions. 2ABD matches with a good accuracy the AGD for a 100% glandular-breast: the minimum, maximum, and mean differences were < 0.1%, 7%, and 2.4%, respectively; the discrepancies increase with decreasing breast glandularity. CONCLUSIONS: The proposed model, based on only few exposure parameters, represents a simple way to individually calculate an index, 2ABD, which can be interpreted as the average absorbed dose in a homogeneous phantom, approximating a 100% glandular breast. The method could be easily implemented in any mammographic device performing DBT.


Subject(s)
Breast/diagnostic imaging , Mammography , Radiation Dosage , Breast Neoplasms/diagnostic imaging , Female , Humans , Phantoms, Imaging
9.
Australas Phys Eng Sci Med ; 42(4): 1141-1152, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31728938

ABSTRACT

Recent advances in digital breast tomosynthesis (DBT) technology were focused on the reconstruction of 2D "Synthesized Mammograms" (SMs) from DBT dataset. The introduction of SMs could avoid an additional digital mammography (DM) which is often required in complement to DBT examinations. Therefore, breast absorbed dose and compression time can be significantly reduced in DBT+SM procedures with respect to DBT+DM modality. However, to date, a limited number of studies have objectively characterised the image quality of SMs with respect to DM images. Therefore, the aim of this phantom study was to comprehensively compare SMs and DM images in terms of several image quality parameters. A Selenia Dimensions system (Hologic, Bedford, Mass, USA) was employed in this work. Five different phantoms were adopted to study noise, contrast and spatial resolution properties of the images. Specifically, noise power spectrum (NPS), maps of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), modulation transfer function (MTF) and contrast-detail (CD) thresholds were evaluated both for SM and DM modalities. SMs were characterised by different texture, noise and SNR spatial distribution properties with respect to DM images. Additionally, while in some conditions SM provides higher CNR than DM, lower overall performances in terms spatial resolution and CD curves were found in comparison to DM images. Therefore, given the great benefits of SMs in terms of dose and compression time saving, further clinical investigations on SMs image quality properties could be of practical interest to integrate our findings.


Subject(s)
Mammography/standards , Radiographic Image Enhancement , Algorithms , Contrast Media/chemistry , Female , Humans , Phantoms, Imaging , Signal-To-Noise Ratio
10.
Cardiovasc Intervent Radiol ; 41(9): 1373-1383, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29654507

ABSTRACT

PURPOSE: To retrospectively compare early response to yttrium-90 radioembolization (Y90) according to volumetric iodine uptake (VIU) changes, Response Evaluation Criteria In Solid Tumor 1.1 (RECIST 1.1) and modified RECIST (mRECIST) in patients with intermediate-advanced hepatocellular carcinoma (HCC) and to explore their association with survival. MATERIALS AND METHODS: Twenty-four patients treated with Y90 and evaluated with dual-energy computed tomography before and 6 weeks after treatment were included. VIU was measured on late arterial phase spectral images; 6-week VIU response was defined as: complete response (CR, absence of enhancing tumor), partial response (PR, ≥ 15% VIU reduction), progressive disease (PD, ≥ 10% VIU increase) and stable disease (criteria of CR/PR/PD not met). RECIST 1.1 and mRECIST were evaluated at 6 weeks and 6 months. Responders included CR and PR. Overall survival (OS) was evaluated by Kaplan-Meier analysis and compared by Cox regression analysis. RESULTS: High intraobserver and interobserver agreements were observed in VIU measurements (k > 0.98). VIU identified a higher number of responders (18 patients, 75%), compared to RECIST 1.1 (12.5% at 6 weeks and 23.8% at 6 months) and mRECIST (29.2% at 6 weeks and 61.9% at 6 months). There was no significant correlation between OS and RECIST 1.1 (P = 0.45 at 6 weeks; P = 0.21 at 6 months) or mRECIST (P = 0.38 at 6 weeks; P = 0.79 at 6 months); median OS was significantly higher in VIU responders (17.2 months) compared to non-responders (7.4 months) (P = 0.0022; HR 8.85; 95% CI 1.29-88.1). CONCLUSION: VIU is highly reproducible; as opposite to mRECIST and RECIST 1.1, early VIU response correlates with OS after Y90 in intermediate-advanced HCC patients.


Subject(s)
Brachytherapy/methods , Carcinoma, Hepatocellular/radiotherapy , Iodine/pharmacokinetics , Liver Neoplasms/radiotherapy , Yttrium Radioisotopes/therapeutic use , Adult , Aged , Carcinoma, Hepatocellular/diagnostic imaging , Female , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Liver/diagnostic imaging , Liver/radiation effects , Liver Neoplasms/diagnostic imaging , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , Tomography, X-Ray Computed/methods , Treatment Outcome
11.
Eur Radiol Exp ; 1(1): 28, 2017.
Article in English | MEDLINE | ID: mdl-29708206

ABSTRACT

BACKGROUND: The new European Directive 2013/59/EURATOM requires that patients are informed about the risk associated with ionising radiation and that detailed information on patient exposure is included in the radiological report. This implies a revision of the routinely used dose indexes to obtain quantities related to individual exposure evaluable from acquisition parameters. Here we propose a new mammography dose index consistent with the average glandular dose (AGD). METHODS: An equation has been developed for calculating the average absorbed breast dose (2ABD). It depends on incident air kerma ka,i and on energy absorption coefficient µen; ka,i can be calculated for each anode-filter combination, based on kVp, mAs, the yield of the tube used Ytb , and the breast thickness d; µen depends on kVp and has been evaluated for each anode-filter combination. 2ABD has been compared to AGD evaluated by Dance or Wu methods, which represent the reference standards, for 20 patients of our university hospital. RESULTS: The incident air kerma ka,i , calculated as a function of kVp, mAs, Ytb and d, was in good agreement with the same quantity directly measured: the relative uncertainty is < 0.10. The results of the comparison between 2ABD and AGD evaluated by both Dance and Wu methods appear to be consistent within the uncertainties. CONCLUSIONS: 2ABD is easily evaluable for each mammogram from the acquisition parameters. It can be proposed as a new suitable dose index, consistent with AGD, matching the requirements of the 2013 European Directive.

12.
Phys Med ; 31(7): 726-32, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26099431

ABSTRACT

PURPOSE: We propose to summarize the advancements introduced by the new Directive 2013/59/Euratom concerning the concept of clearance, for which the radioactive medical waste represents a typical candidate. We also intend to spotlight disputable points in the regulatory scheme in force in Italy, as well to make a contribution to evaluate whether the practice of patients' urine storing, stated by it, can be regarded to be proper. METHODS: With directing our interest to radionuclides used in Nuclear Medicine, we first present an overview of how the clearance concept, and that of exemption closely related to it, have been developed from the previous Directive 96/29 to the new one; then we describe the implementation of these concepts in the Italian legislation. Subsequently we estimate the exposure due both to keeping the effluent on site and to direct discharging it to the environment. RESULTS: In line with a well established international consensus, the Directive 2013/59 drives simple and harmonized regulation of clearance. On the contrary, some complexity and lack of consistency can be found in the framework of the national legislation affecting the radioactive medical waste handling. In addition the practice of excreta storing is disputed not to be really beneficial. CONCLUSION: The opportunity should be taken to make the whole system of these requirements simpler and more consistent and effective when it is revised to transpose the new Directive.


Subject(s)
Hospitals , Radiation Protection/legislation & jurisprudence , Radioactive Waste/legislation & jurisprudence , Waste Management/legislation & jurisprudence , Fresh Water/chemistry , Half-Life , Sewage/chemistry
13.
Rev. esp. med. nucl. imagen mol. (Ed. impr.) ; 34(2): 111-115, mar.-abr. 2015. tab, ilus
Article in English | IBECS | ID: ibc-134607

ABSTRACT

In this paper we report on a successful management of multiple bone metastases from differentiated thyroid cancer. In 2007, a 75-year-old female patient, previously referred for thyroidectomy for multinodular goiter, underwent surgical removal of a lumbar mass with histological findings of metastasis from well differentiated thyroid cancer. After surgery, serum thyroglobulin (sTg) was 204.4 ng/mL. A diagnostic/dosimetric 123 I WBS was performed, following stimulation by rTSH. Serial WBSs were acquired, along with SPECT/CT and bone scan for localization of lesions. sTg raised to 3.810 ng/mL, and 123 I WBS showed thyroid remnants and numerous areas with high iodine-uptake corresponding to skeletal sites, the two largest loading on the skull, with osteolytic pattern. Calculated radiation absorbed dose for skull lesions, determined by mean of MIRD methodology, was 63.5 mGy/MBq. The patient underwent surgical removal of the two major skull lesions. Successively, 100mCi 131I was administered after stimulation by rTSH, with stimulated sTg 297 ng/mL. After 8 months, diagnostic WBS was negative both for remnants and metastases and rTSH-stimulated Tg was 0.6 ng/mL. To date, the patient has maintained sTg values <1 ng/mL during L-T4 suppressive therapy and after rTSH stimulations. In this unusual case of extensive bone cancerous involvement with high iodine avidity, a multidisci-plinary approach based on surgery and dosimetry-guided radiometabolic therapy allowed to accurately assess the patient, execute a small number of treatments and achieve a complete remission of the disease in a very short time, with no additive morbidity (AU)


En este trabajo presentamos el abordaje adecuado de múltiples metástasis óseas de un cáncer diferenciado de tiroides. En 2007, una mujer de 75 años previamente remitida para tiroidectomía por bocio multinodular, se sometió a la extirpación quirúrgica de una masa lumbar con resultado histológico de metástasis de cáncer bien diferenciado de tiroides. Tras la cirugía, los niveles séricos de tiroglobulina (Tgs) fueron 204,4 ng/ml. Se realizó un rastreo de cuerpo completo diagnóstico/dosimétrico con 123 I después de la estimulación con rTSH. Se adquirieron rastreos seriados junto con SPECT/TC y gammagrafía ósea para la localización de las lesiones. Los niveles de Tgs se elevaron a 3810 ng/ml, y el rastreo de cuerpo completo con 123 I demostró captación en restos tiroideos y en numerosas localizaciones esqueléticas, las dos de mayor tamaño en la calota con un patrón osteolítico. La dosis absorbida calculada para las lesiones de calota, determinada mediante metodología MIRD, fue 63,5 mGy/MBq. Se extirparon mediante cirugía las 2 lesiones de la calota. Posteriormente, se administraron 100 mCi 131 I tras la estimulación con rTSH y unos niveles de Tgs 297 ng/ml. Después de 8 meses, el rastreo diagnóstico de cuerpo completo fue negativo tanto para los restos tiroideos como para las metástasis y la Tgs estimulada con rTSH fue 0,6 ng/ml. En la actualidad, la paciente ha mantenido valores de Tgs <1 ng/ml durante la terapia supresora con T4L y después de la estimulación con rTSH. En este caso poco habitual de extensa afectación metastásica ósea con elevada captación de radioiodo, una estrategia multidisciplinaria basada en cirugía y radioterapia metabólica según dosimetría permitió evaluar con precisión a la paciente, administrar un número pequen ̃o de tratamientos y alcanzar una remisión completa de la enfermedad en muy breve tiempo, sin originar morbilidad adicional (AU)


Subject(s)
Humans , Female , Aged , Thyroid Neoplasms , Neoplasm Metastasis , Bone Neoplasms/secondary , Radiotherapy, Image-Guided/methods , Thyroidectomy , Tomography, Emission-Computed, Single-Photon , Skull Neoplasms
14.
Rev Esp Med Nucl Imagen Mol ; 34(2): 111-5, 2015.
Article in English | MEDLINE | ID: mdl-25455505

ABSTRACT

In this paper we report on a successful management of multiple bone metastases from differentiated thyroid cancer. In 2007, a 75-year-old female patient, previously referred for thyroidectomy for multinodular goiter, underwent surgical removal of a lumbar mass with histological findings of metastasis from well differentiated thyroid cancer. After surgery, serum thyroglobulin (sTg) was 204.4 ng/mL. A diagnostic/dosimetric (123)I WBS was performed, following stimulation by rTSH. Serial WBSs were acquired, along with SPECT/CT and bone scan for localization of lesions. sTg raised to 3.810 ng/mL, and (123)I WBS showed thyroid remnants and numerous areas with high iodine-uptake corresponding to skeletal sites, the two largest loading on the skull, with osteolytic pattern. Calculated radiation absorbed dose for skull lesions, determined by mean of MIRD methodology, was 63.5 mGy/MBq. The patient underwent surgical removal of the two major skull lesions. Successively, 100 mCi (131)I was administered after stimulation by rTSH, with stimulated sTg 297 ng/mL. After 8 months, diagnostic WBS was negative both for remnants and metastases and rTSH-stimulated Tg was 0.6 ng/mL. To date, the patient has maintained sTg values <1 ng/mL during L-T4 suppressive therapy and after rTSH stimulations. In this unusual case of extensive bone cancerous involvement with high iodine avidity, a multidisciplinary approach based on surgery and dosimetry-guided radiometabolic therapy allowed to accurately assess the patient, execute a small number of treatments and achieve a complete remission of the disease in a very short time, with no additive morbidity.


Subject(s)
Adenocarcinoma, Follicular/secondary , Cytoreduction Surgical Procedures , Iodine Radioisotopes/therapeutic use , Lumbar Vertebrae/surgery , Neoplasms, Unknown Primary , Radiopharmaceuticals/therapeutic use , Single Photon Emission Computed Tomography Computed Tomography , Skull Neoplasms/secondary , Spinal Neoplasms/secondary , Adenocarcinoma, Follicular/diagnostic imaging , Adenocarcinoma, Follicular/radiotherapy , Adenocarcinoma, Follicular/surgery , Aged , Craniotomy , Female , Goiter, Nodular/surgery , Humans , Iodine Radioisotopes/administration & dosage , Laminectomy , Lumbar Vertebrae/diagnostic imaging , Neoplasms, Unknown Primary/diagnostic imaging , Neoplasms, Unknown Primary/radiotherapy , Osteolysis/diagnostic imaging , Osteolysis/etiology , Postoperative Complications/diagnostic imaging , Postoperative Complications/radiotherapy , Postoperative Complications/surgery , Radiopharmaceuticals/administration & dosage , Recombinant Proteins/pharmacology , Remission Induction , Skull Neoplasms/diagnostic imaging , Skull Neoplasms/radiotherapy , Skull Neoplasms/surgery , Sodium Iodide , Spinal Neoplasms/diagnostic imaging , Spinal Neoplasms/radiotherapy , Spinal Neoplasms/surgery , Technetium Tc 99m Medronate/analogs & derivatives , Thyroid Neoplasms/surgery , Thyroidectomy , Thyrotropin/pharmacology
15.
PLoS One ; 9(1): e86280, 2014.
Article in English | MEDLINE | ID: mdl-24489711

ABSTRACT

Breast imaging represents a relatively recent and promising field of application of quantitative diffusion-MRI techniques. In view of the importance of guaranteeing and assessing its reliability in clinical as well as research settings, the aim of this study was to specifically characterize how the main MR scanner system-related factors affect quantitative measurements in diffusion-MRI of the breast. In particular, phantom acquisitions were performed on three 1.5 T MR scanner systems by different manufacturers, all equipped with a dedicated multi-channel breast coil as well as acquisition sequences for diffusion-MRI of the breast. We assessed the accuracy, inter-scan and inter-scanner reproducibility of the mean apparent diffusion coefficient measured along the main orthogonal directions () as well as of diffusion-tensor imaging (DTI)-derived mean diffusivity (MD) measurements. Additionally, we estimated spatial non-uniformity of (NU) and MD (NUMD) maps. We showed that the signal-to-noise ratio as well as overall calibration of high strength diffusion gradients system in typical acquisition sequences for diffusion-MRI of the breast varied across MR scanner systems, introducing systematic bias in the measurements of diffusion indices. While and MD values were not appreciably different from each other, they substantially varied across MR scanner systems. The mean of the accuracies of measured and MD was in the range [-2.3%,11.9%], and the mean of the coefficients of variation for and MD measurements across MR scanner systems was 6.8%. The coefficient of variation for repeated measurements of both and MD was < 1%, while NU and NUMD values were <4%. Our results highlight that MR scanner system-related factors can substantially affect quantitative diffusion-MRI of the breast. Therefore, a specific quality control program for assessing and monitoring the performance of MR scanner systems for diffusion-MRI of the breast is highly recommended at every site, especially in multicenter and longitudinal studies.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging/methods , Female , Humans , Reproducibility of Results , Signal-To-Noise Ratio
17.
Med Phys ; 40(2): 022502, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23387769

ABSTRACT

PURPOSE: Thyroid (131)I effective half-life (T(eff)) is an essential parameter in patient therapy when accurate radiation dose is desirable for producing an intended therapeutic outcome. Multiple (131)I uptake measurements and resources from patients themselves and from nuclear medicine facilities are requisites for determining T(eff), these being limiting factors when implementing the treatment planning of Graves' disease (GD) in radionuclide therapy. With the aim of optimizing this process, this study presents a practical, propitious, and accurate method of determining T(eff) for dosimetric purposes. METHODS: A total of 50 patients with GD were included in this prospective study. Thyroidal (131)I uptake was measured at 2-h, 6-h, 24-h, 48-h, 96-h, and 220-h postradioiodine administration. T(eff) was calculated by considering sets of two measured points (24-48-h, 24-96-h, and 24-220-h), sets of three (24-48-96-h, 24-48-220-h, and 24-96-220-h), and sets of four (24-48-96-220-h). RESULTS: When considering all the measured points, the representative T(eff) for all the patients was 6.95 (±0.81) days, whereas when using such sets of points as (24-220-h), (24-96-220-h), and (24-48-220-h), this was 6.85 (±0.81), 6.90 (±0.81), and 6.95 (±0.81) days, respectively. According to the mean deviations 2.2 (±2.4)%, 2.1 (±2.0)%, and 0.04 (±0.09)% found in T(eff), calculated based on all the measured points in time, and with methods using the (24-220-h), (24-48-220-h), and (24-96-220-h) sets, respectively, no meaningful statistical difference was noted among the three methods (p > 0.500, t test). CONCLUSIONS: T(eff) obtained from only two thyroid (131)I uptakes measured at 24-h and 220-h, besides proving to be sufficient, accurate enough, and easily applicable, attributes additional major cost-benefits for patients, and facilitates the application of the method for dosimetric purposes in the treatment planning of Graves' disease.


Subject(s)
Graves Disease/metabolism , Graves Disease/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Thyroid Gland/metabolism , Thyroid Gland/radiation effects , Adult , Aged , Female , Half-Life , Humans , Iodine Radioisotopes/metabolism , Iodine Radioisotopes/therapeutic use , Male , Middle Aged , Young Adult
18.
Med Phys ; 38(6): 3205-11, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21815395

ABSTRACT

PURPOSE: Diffusion tensor imaging (DTI) is highly sensitive to noise and improvement of radiofrequency coil technology represents a straightforward way for augmenting signal-to-noise ratio (SNR) performance in magnetic resonance imaging (MRI) scanners. The aim of this study was to characterize the dependence of DTI measurements of fractional anisotropy (FA) and mean diffusivity (MD) on the choice of head coil, comparing two head coils with different functional designs and sensitivities. METHODS: Fourteen healthy subjects underwent DTI acquisitions at 1.5 T. Every subject was scanned twice, using a standard quadrature birdcage head coil (coil-A) and an eight-channel array head coil (coil-B). FA and MD maps, estimated using both the linear least squares (LLS) and nonlinear least squares (NLLS) methods, were nonlinearly normalized into a standard space. Then, volumetric regions of interest encompassing typical white and gray matter structures [splenium of the corpus callosum (SCC), internal capsule (IC), cerebral peduncles (CP), middle cerebellar peduncles (MCP), globus pallidus (GP), thalamus (TH), caudate (CA), and putamen (PU)] were analyzed. Significant differences and trends of variation in DTI measurements were assessed by the Wilcoxon test for paired samples with and without Bonferroni correction for multiple comparisons, respectively. RESULTS: The overall SNR of coil-B was 30% higher than that of coil-A. When comparing DTI measurements (coil-B versus coil-A), mean FA values (SCC, IC, and TH), mean MD values (IC, CP, GP, and TH), FA standard deviation (CP, MCP, GP, and CA), and MD standard deviation (IC, CP, TH, and PU) resulted decreased (significant difference, p(cor) < 0.05, or trend of variation, P(uncor) < 0.05) in several gray and white matter regions of the human brain. With the exception of CP, the results in terms of revealed significant difference or trend of variation were independent of the method (LLS and NLLS) used for estimating the diffusion tensor. CONCLUSIONS: In various gray and white matter structures, the eight-channel array head coil yielded more precise and accurate measurements of DTI derived indices compared to the standard quadrature birdcage head coil.


Subject(s)
Diffusion Tensor Imaging/instrumentation , Radio Waves , Adult , Anisotropy , Brain , Equipment Design , Female , Humans , Image Processing, Computer-Assisted , Male , Young Adult
19.
Phys Med ; 26(2): 71-9, 2010 Apr.
Article in English | MEDLINE | ID: mdl-19800827

ABSTRACT

OBJECTIVE: In Graves' disease therapy, the amount of (131)I is usually decided following two different modalities: the administration of a fixed activity or of an activity individually calculated based on a fixed value of target absorbed dose. Although the effectiveness of each of these approaches is good (about 80% of patients cured), the ALARA principle must be applied avoiding the un-justified radioactivity to the patient himself, the people living/working near him and the environment. In this paper a new approach to the (131)I therapy in Graves' disease, based on the optimum value of the final thyroid mass, is presented. DESIGN: 97 Graves' disease patients (29 males) were randomly assigned into three groups (GR1, GR2, GR3). In two of them (GR1, GR3) the radioiodine administering activity was calculated based on two fixed thyroid absorbed dose values (100 Gy for GR1; 400 Gy for GR3), in GR2 it was calculated based on the desired final optimum thyroid mass value m(f)=0.24 m(0)/U(0) RESULTS: The rate of cured patients are 48% (GR1), 97% (GR2) (z-test, p<0.001) and 97% (GR3). The average activity administered to GR2 (393 + or - 157 MBq) is lower than that administrered to GR3 patients (524 + or - 201 MBq) (p=0.007, two-tails unpaired t-test); the thyroid absorbed dose in GR2 (262 + or - 78 Gy) is lower than in GR3 patients (407 + or - 23 Gy) (p<0.001, two-tails unpaired t-test). CONCLUSION: Our results demonstrate that the thyroid-mass based approach optimizes the treatment avoiding an un-justified excess or a not-effective too low activity without time and resources consuming.


Subject(s)
Graves Disease/radiotherapy , Iodine Radioisotopes/therapeutic use , Radiopharmaceuticals/therapeutic use , Radiotherapy Planning, Computer-Assisted/methods , Algorithms , Female , Graves Disease/pathology , Humans , Iodine Radioisotopes/administration & dosage , Male , Middle Aged , Organ Size , Radiation Dosage , Radiopharmaceuticals/administration & dosage , Thyroid Gland/pathology , Thyroid Gland/radiation effects , Treatment Outcome
20.
Arch Otolaryngol Head Neck Surg ; 134(12): 1328-33, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19075131

ABSTRACT

OBJECTIVE: To determine plasma levels of homocysteine, folate, and vitamin B12 in patients with laryngeal cancer and a control group. DESIGN: Analysis of homocysteine, folate, and vitamin B12 levels in 25 consecutive untreated patients with laryngeal carcinoma and 80 healthy control participants. The study and control groups were subdivided into smokers, ex-smokers, and nonsmokers, as well as drinkers and nondrinkers. INTERVENTION: The AxSYM system was used to measure total homocysteine levels, and the ARCHITECT system (both Abbott-Diagnostics Division) was used to measure folate and vitamin B12 levels. MAIN OUTCOME MEASURES: Homocysteine, folate, and vitamin B12 levels. RESULTS: The mean (SD) level of total homocysteine in patients with laryngeal carcinoma was 2.84 (1.62) mg/L vs 0.99 (0.24) mg/L in the control group (P <.001). The mean (SD) folate plasma level was 4.3 (2.2) ng/mL vs 7.9 (2.4) ng/mL (P <.001). CONCLUSIONS: Metabolic alterations in homocysteine, folate, and vitamin B12 levels, especially hypofolatemia, could be associated with laryngeal cancer. Lengthier follow-up studies and larger groups of patients will help determine the real role of these metabolic alterations.


Subject(s)
Folic Acid/blood , Homocysteine/blood , Laryngeal Neoplasms/blood , Vitamin B 12/blood , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged