Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 29
Filter
1.
J Vasc Surg ; 75(2): 753-761.e3, 2022 02.
Article in English | MEDLINE | ID: mdl-34624495

ABSTRACT

OBJECTIVE: The aim of the study was to summarize epidemiologic data about aortobronchial fistulae and compare outcomes (mortality, recurrence, reoperation) of open, staged, and endovascular repair of aortobronchial fistula. METHODS: A systematic literature review was conducted to identify eligible studies published between January 1999 and December 2019. The Cochrane Library, PubMed, and Scopus databases were used as search engines. Eligible studies included articles reporting postoperative outcomes (death/follow-up). Literature review revealed only case reports and small case series, and thus, only descriptive data with data heterogeneity were available. The corresponding authors were contacted to provide additional information or outcome updates (recurrence/reoperation/death). RESULTS: Overall, 214 patients (90 studies) underwent 271 procedures (including redo procedures and staged procedures). Most of the patients were treated by endovascular means (72.42%). Open surgical repair was performed in 21.96% and staged procedures in 5.6%. Aortobronchial fistulae were located most often in the descending thoracic aorta (zone 3 or 4) (64.6%) and in zone 2 (23.8%). Fourteen percent of aortobronchial fistulae developed after thoracic endovascular aneurysm repair. Recurrence or infection occurred in 20% (43) patients. Recurrences were, to some extent, associated with the presence of endoleak. Long-term antibiotic administration (>1 month) was instituted in 63 patients (29.4%), whereas 90 patients (42%) did not receive antibiotics beyond hospitalization. From the remaining 61 patients, 3 received lifelong antibiotics and for 58 patients data were not available. Considering outcomes, the mean follow-up was 25.1 months (0-188 months) and not significantly different among treatments. LIMITATIONS: Literature review has revealed only case reports and small case series, and thus, only descriptive data were available. Randomized controlled trials are not available due to the rarity of the disease, which significantly decreases the power of the present study. Also, this study reflects significant data heterogeneity due to the nature of the analyzed manuscripts and would benefit from large patient cohort studies that have not been conducted till today. CONCLUSIONS: Aortobronchial fistula is a complex disease. Endoleaks may be involved in the development and the recurrence process, and they should not be disregarded. Considering major outcomes (length of follow-up), the available treating strategies are equal, and thus, surgeons should feel confident to apply the treatment of their choice, keeping in mind their experience, patient's age, and clinical condition.


Subject(s)
Aorta, Thoracic , Bronchi , Bronchial Fistula/surgery , Endovascular Procedures/adverse effects , Thoracic Surgical Procedures/methods , Vascular Fistula/surgery , Bronchial Fistula/diagnosis , Bronchial Fistula/etiology , Humans , Reoperation , Tomography, X-Ray Computed , Vascular Fistula/diagnosis , Vascular Fistula/etiology
2.
Ann Vasc Surg ; 59: 309.e11-309.e14, 2019 Aug.
Article in English | MEDLINE | ID: mdl-30825509

ABSTRACT

Secondary aortobronchial fistula (ABF) is an uncommon clinical entity associated with increased mortality. Most common presentation is hemoptysis, ranging from repetitive self-limiting episodes to massive hematemesis. Mediastinitis (if present) and excessive blood loss burden the unfavorable case of ABF, whereas stent-graft contamination and sepsis are the main concerns regarding endovascular therapy. We are presenting two patients with secondary ABF treated with thoracic endovascular repair who completed long-term follow-up without complications or evidence of infection.


Subject(s)
Aneurysm, False/surgery , Aortic Aneurysm, Thoracic/surgery , Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation , Bronchial Fistula/surgery , Endovascular Procedures , Vascular Fistula/surgery , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Angiography, Digital Subtraction , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/etiology , Aortic Diseases/diagnostic imaging , Aortic Diseases/etiology , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Bronchial Fistula/diagnostic imaging , Bronchial Fistula/etiology , Computed Tomography Angiography , Endovascular Procedures/instrumentation , Humans , Male , Middle Aged , Time Factors , Treatment Outcome , Vascular Fistula/diagnostic imaging , Vascular Fistula/etiology
3.
Vasc Specialist Int ; 35(4): 237-240, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31915669

ABSTRACT

We presented a challenging case of a patient diagnosed with abdominal aortic aneurysm (AAA), peripheral artery disease, and chronic mesenteric ischemia (CMI). Herein, we describe the treatment in this high-risk patient diagnosed with CMI who also had critical limb ischemia and his AAA had rapidly expanded. First we performed angioplasty and celiac arterial stenting. Afterwards, we proceeded to perform balloon angioplasty of the iliac arteries and chimney endovascular aneurysm repair (Ch-EVAR) preserving the inferior mesenteric artery (IMA). The patient was discharged three days later and his IMA remained patent eighteen months post-operation. A thorough pre-operative assessment is essential in such challenging cases. Minimally invasive procedures like endovascular therapy and the chimney technique extend the prognoses in high-risk patients.

5.
Expert Rev Med Devices ; 13(3): 253-62, 2016.
Article in English | MEDLINE | ID: mdl-26822951

ABSTRACT

The Ovation Abdominal Stent Graft System is a trimodular endoprosthesis recently introduced for the endovascular repair of abdominal aortic aneurysm (AAA). It uncouples the stages of stent-graft fixation and sealing with the suprarenal fixation achieved with a long, rigid anchored stent while the sealing onto the neck is accomplished via a pair of polymer-filled inflatable rings that accommodate to each patient's individual anatomy. Moreover, the lack of Nitinol support enables lower profiles of the endograft's delivery system, thus facilitating the navigation through angulated and stenosed iliac vessels. Ovation's novel design expands further the AAA eligibility to endovascular repair. This article discusses the clinical and hemodynamic consequences of the Ovation design and contributes to better understanding of current and future implications.


Subject(s)
Abdomen/surgery , Aortic Aneurysm, Abdominal/surgery , Stents , Abdomen/physiopathology , Aortic Aneurysm, Abdominal/physiopathology , Blood Vessel Prosthesis Implantation , Clinical Trials as Topic , Hemodynamics , Humans , Prosthesis Design
6.
J Endovasc Ther ; 22(4): 613-9, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26078426

ABSTRACT

PURPOSE: To compare the immediate suprarenal neck angulation change between the Ovation stent-graft, with its inflatable sealing rings, and a stent-graft with a conventional sealing mechanism. METHODS: A case-control study was conducted in which 30 consecutive patients (mean age 67 years; all men) with abdominal aortic aneurysm (AAA) treated with the Ovation stent-graft (group O) were retrospectively compared with 24 patients (mean age 77 years; all men) contemporaneously treated with the Endurant stent-graft (group E) at 3 high-volume tertiary vascular centers. The variables recorded were the aortic neck length, preoperative and postoperative angulation, minimum and maximum diameters of the infrarenal neck, as well as the maximum AAA diameter. All patients had undergone preoperative and postoperative (within 30 days) computed tomographic angiography. Multiple regression analysis compared the relative contribution to neck angulation change of each geometric parameter and the type of endograft. Data are presented as the mean ± standard deviation. RESULTS: The mean preoperative suprarenal neck angulation in group O was 23.2°±18.0° compared with 23.8°±22.9° in group E (t test, p=0.91). The neck lengths were 29.2±14.6 and 23.2±11.0 mm in groups O and E, respectively (p=0.1). Similarly, the minimum and maximum neck diameters were 22.4±2.6 and 25±3.5 mm, respectively, in group O vs 23.3±3.6 mm and 27.0±5.7 mm, respectively, in group E (p=0.3 and 0.12, respectively). The maximum transverse diameters of the AAA in the 2 groups were comparable, that is, 57.0±9.0 mm in group O vs 53.2±11.1 mm in group E (p=0.17). The Ovation stent-graft caused greater decrease in the aortic neck angulation postoperatively compared with the Endurant device (13.2°±16.1° vs 6.1°±5.9°, p=0.04). Multiple regression analysis revealed that preoperative neck angulation (ß coefficient 0.37, p<0.001) and the type of endograft (ß coefficient -7.91, p=0.01) had significant influence on the postoperative neck angulation change. The intraclass correlation coefficient ranged from 0.951 to 0.990 for the preoperative measurements and from 0.911 to 0.999 for the postoperative measurements for each examiner or the total of estimates at the measurement time points. CONCLUSION: The Ovation stent-graft induces greater postoperative reduction in the AAA neck angulation compared to an endograft with stent-supported graft seal. Expanded research to infrarenal angle as well to greater angles and correlation to clinical events is justified.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis , Endovascular Procedures/methods , Renal Artery/diagnostic imaging , Aged , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortography , Humans , Male , Retrospective Studies , Stents , Tomography, X-Ray Computed , Treatment Outcome
7.
Ann Vasc Surg ; 29(5): 913-9, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25728329

ABSTRACT

BACKGROUND: To present our preliminary results with the Ovation(™) abdominal stent-graft system in abdominal aortic aneurysms (AAA) with narrow (≤7 mm) or angulated iliac vessels. METHODS: From April 2012 to January 2014, 42 patients (97% men; mean age, 71 years; range, 55-89 years) with AAAs of 55.5 mm (50-79 mm) were treated with the Ovation device. Primary end points included technical success and freedom from early secondary interventions, any type of endoleak, and aneurysm-related death. Limb occlusion was studied with respect to iliac access diameter and angulation. Iliac angulation between 90° and 120° or <90° was considered moderate or severe, respectively. RESULTS: The postoperative follow-up was 7.8 ± 4.6 months (mean ± standard deviation). Infrarenal neck angulation was 26° ± 26°. AAA neck length and diameter were 27.3 ± 10.5 and 24.1 ± 3.2 mm, respectively. Forty-five percent of patients had at least 1 vessel of ≤7-mm diameter, and almost half of patients (24 of 44) had at least 1 iliac artery of moderate or severe angulation. Technical and treatment success were 100% and 95%, respectively. No stent-graft migration or type I, III, or IV endoleaks occurred. Type II endoleaks were identified in 5 patients, leading to sac enlargement in 2 and necessitating an embolization attempt that was unsuccessful in 1 case. No limb occlusion occurred, irrespective of the iliac diameter or angulation. CONCLUSIONS: Our 1-year results of the Ovation stent-graft system demonstrate excellent safety and effectiveness. The easy navigation through highly angulated and stenosed iliac vessels ensures high technical success in cases of challenging iliac anatomy. Follow-up is ongoing.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Iliac Artery/surgery , Stents , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Embolization, Therapeutic , Endoleak/etiology , Endoleak/therapy , Endovascular Procedures/adverse effects , Female , Greece , Humans , Iliac Artery/diagnostic imaging , Male , Middle Aged , Prosthesis Design , Risk Factors , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
8.
Cardiovasc J Afr ; 25(5): 239-43, 2014.
Article in English | MEDLINE | ID: mdl-25182343

ABSTRACT

Endovascular aortic aneurysm repair with the Endurant™ stent-graft system has been shown to be safe and effective in high-risk surgical patients with complex suprarenal and/or infrarenal abdominal aortic aneurysm anatomy. The wireformed M-shaped stent architecture and proximal springs with anchoring pins theoretically permit optimal sealing in shorter and more angulated proximal aneurysm necks even under off-label conditions. Nonetheless, extremely difficult anatomical situations and inherent graft system-related limitations must be anticipated. Herein, we describe our techniques to overcome the capture of the tip sleeve within the suprarenal bare-stent anchoring pins, other endograft segments, and native vessels.


Subject(s)
Aorta, Abdominal/surgery , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis , Endovascular Procedures/methods , Stents , Aortography , Humans , Prosthesis Design
11.
J Endovasc Ther ; 21(2): 333-8, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24754296

ABSTRACT

PURPOSE: To describe technical challenges encountered using the Ovation endograft for abdominal aortic aneurysms and suggest tips and maneuvers for successful management. TECHNIQUE: Deployment of the Ovation's unsupported main body is often associated with the anteroposterior arrangement of the limb gates instead of the usual side-by-side configuration, rendering contralateral catheterization challenging. Successful catheterization of the contralateral limb can be confirmed by lateral deviation of the ipsilateral stiff guidewire caused by balloon inflation within the contralateral limb. Moreover, failure to cannulate the contralateral limb gate due to persistent impingement of the guidewire or compromise of the inflated rings can be overcome using the transbrachial antegrade approach. CONCLUSION: Awareness of certain aspects associated with the use of the Ovation device and adoption of the adjunctive techniques herein described helps the interventionist avoid unexpected challenges or manage technical difficulties to maximize the device's safety and effectiveness.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Aortic Aneurysm, Abdominal/diagnosis , Aortography , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Humans , Postoperative Complications/prevention & control , Prosthesis Design , Treatment Outcome
12.
Int J Artif Organs ; 37(2): 177-81, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24619891

ABSTRACT

Advances in abdominal aortic aneurysm (AAA) endograft device technology have contributed to improved outcomes and durability of endovascular aortic aneurysm repair (EVAR), even in complex infrarenal aortic anatomies. However, stent graft failure secondary to endoleaks, migration, endotension and sac enlargement are persistent problems that can result in aneurysm rupture following EVAR.A symptomatic infrarenal AAA (4mm proximal neck) was treated initially with an Ovation Prime™ device (TriVascular, Inc., Santa Rosa, CA) in an off-label fashion, leading to type Ia endoleak moderately reduced by additional proximal neck ballooning. A failed Chimney technique to the single patent, but severely stenosed, right renal artery preceded the use of this device. A large type Ia endoleak was evident at 6-month follow-up, but following a failed supplementary endovascular intervention with coils to seal the endoleak, the patient presented with hemorrhagic shock from AAA rupture, requiring urgent open conversion. Intraoperatively it was impossible to explant this new type of endograft. Circumferential tying of the infrarenal aorta with a Teflon band was unable to stop the bleeding. However, after dividing the body of the stent-graft below the two proximal polymer rings, the endoleak was successfully treated by suturing the graft with the proximal aortic neck. The procedure was completed with extension of the stump to the common femoral arteries using a bifurcated Dacron prosthesis.The body of an Ovation Prime™ endograft may be impossible to explant in open conversion conditions. Large prospective studies with longer follow-up are required to adequately reflect the behavior of this particular device.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortic Rupture , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endoleak , Endovascular Procedures , Reoperation/methods , Aged , Aortic Aneurysm, Abdominal/diagnosis , Aortic Aneurysm, Abdominal/physiopathology , Aortic Rupture/diagnosis , Aortic Rupture/etiology , Aortic Rupture/physiopathology , Aortic Rupture/surgery , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/methods , Endoleak/diagnosis , Endoleak/etiology , Endoleak/physiopathology , Endoleak/surgery , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/methods , Fatal Outcome , Humans , Male , Prosthesis Design , Prosthesis Fitting , Tomography, X-Ray Computed/methods
13.
Ann Vasc Surg ; 28(5): 1324-8, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24517987

ABSTRACT

Aortic rupture comprises a potentially fatal condition necessitating emergent treatment. Endovascular sealing of the rupture site is often combined with the use of chimney- and periscope stent placement to preserve perfusion of aortic branches. We present a case of successful endovascular management of contained aortic rupture in a 78-year-old patient. The left brachial access facilitated stenting of the celiac and superior mesenteric arteries, whereas the left femoral route served stenting of the renal artery. One-month follow-up confirmed complete sealing, stent patency, and absence of endograft migration. The combined periscope and chimney technique is feasible and effective in the emergency setting.


Subject(s)
Aneurysm, Ruptured/surgery , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Aged , Aneurysm, Ruptured/diagnosis , Angiography , Aortic Aneurysm, Abdominal/diagnosis , Equipment Design , Follow-Up Studies , Humans , Male , Prosthesis Design , Rupture, Spontaneous , Tomography, X-Ray Computed
15.
J Endovasc Ther ; 21(1): 148-53, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24502496

ABSTRACT

PURPOSE: To evaluate whether postoperative long-term oral anticoagulation affects the durability of endovascular aneurysm repair (EVAR) and whether it is associated with an increased incidence of endoleak and subsequent need for reintervention. METHODS: A literature search was performed to identify studies of abdominal aortic aneurysm patients undergoing EVAR including an arm receiving warfarin postoperatively and reporting the frequency of any endoleaks and/or persistent type II endoleaks and reinterventions. The search identified 81 articles, of which 5 observational cohort studies ultimately met the inclusion criteria. RESULTS: Postoperative anticoagulation was required in 219 (14.6%) of the 1499 patients in the selected studies. The pooled effects analysis found that EVAR patients receiving long-term warfarin postoperatively had significantly more endoleaks of any type (OR 1.77, 95% CI 1.26 to 2.48, p=0.001) as well as persistent type II endoleaks (OR 1.58, 95% CI 1.05 to 2.37, p=0.03) compared with patients not on anticoagulation; however, there was no statistically significant difference in the reintervention rate between the groups. CONCLUSION: Long-term anticoagulation in EVAR patients was associated with a statistically significant increase in any endoleak and persisting type II endoleaks, although it was not linked to an increased risk of reintervention. Close monitoring for EVAR patients who require long-term oral anticoagulation is advised.


Subject(s)
Anticoagulants/adverse effects , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/etiology , Endovascular Procedures/adverse effects , Warfarin/adverse effects , Administration, Oral , Anticoagulants/administration & dosage , Aortic Aneurysm, Abdominal/diagnosis , Chi-Square Distribution , Endoleak/diagnosis , Endoleak/therapy , Humans , Odds Ratio , Retreatment , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Warfarin/administration & dosage
17.
J Endovasc Ther ; 20(6): 853-62, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24325704

ABSTRACT

PURPOSE: To report a case controlled analysis of endovascular aneurysm repair (EVAR) outcomes using the crossed-limb (CxL) endovascular configuration vs. the straight-limb configuration (SLC). METHODS: From January 2007 to July 2012, 27 patients (25 men; mean age 73.7±7.2 years, range 53-82) were treated by EVAR with the CxL technique. These patients were matched anatomically with 27 patients (27 men; mean age 72.4±7.4 years, range 52-86) who underwent EVAR using the same endograft and the standard SLC within a ±6-month period. Primary outcome measures included technical and clinical success and freedom from graft limb thrombosis, any type of endoleak, early or late secondary interventions, and aneurysm-related death estimated using the Kaplan-Meier method. RESULTS: The median follow-up periods for the CxL and SLC groups were 29.9 (range 6-54) and 33.5 (range 6-59) months, respectively (p=0.81). The technical success rate was 100% in both groups, but mean procedure times were significantly longer in the CxL group (116.3 vs. 90.7 minutes, p=0.035). Twelve intraoperative endoleaks (3 each for types Ia, Ib, II, and IV) occurred but without any difference between groups (p=0.51). One CxL group patient died in the early postoperative period (aneurysm-related) and another had an early graft limb thrombosis. One late type Ib intraoperative endoleak was recorded in the SLC group (p=0.51). For the CxL vs. SLC groups, the 1-year rates for freedom from endograft limb thrombosis (94% vs. 96%), any type of endoleak (96% vs. 96%), early or late reintervention (94% vs. 96%), and aneurysm-related death (94% vs. 96%) were not significantly different. Respective values at 36 months were 82% vs. 82%, 85% vs. 84%, 81% vs. 78%, and 83% vs. 84% (p>0.05). Clinical success rates at 12 months for the CxL and SLC groups were 91% and 100% (p>0.05), respectively, whereas at 36 months, the rates were 83% and 90% (p>0.05). CONCLUSION: No difference was found between the crossed-limb technique and the conventional endograft position as regards short- or midterm clinical outcomes.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Chi-Square Distribution , Endoleak/etiology , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Graft Occlusion, Vascular/etiology , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Operative Time , Retrospective Studies , Risk Factors , Stents , Thrombosis/etiology , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
18.
J Vasc Interv Radiol ; 24(10): 1437-49.e3, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23932417

ABSTRACT

Little is known regarding the outcomes of endovascular and surgical treatment of penetrating ulcers in the abdominal aorta. The potential benefit of conservative management of asymptomatic disease is also debatable. A systematic review of the literature was undertaken to investigate these issues.


Subject(s)
Aorta, Abdominal/surgery , Aortic Diseases/mortality , Aortic Diseases/therapy , Endovascular Procedures/mortality , Ulcer/mortality , Ulcer/therapy , Vascular Surgical Procedures/mortality , Aorta, Abdominal/diagnostic imaging , Aortic Diseases/diagnostic imaging , Evidence-Based Medicine , Female , Humans , Male , Prevalence , Radiography , Risk Factors , Treatment Outcome , Ulcer/diagnostic imaging
19.
ANZ J Surg ; 83(10): 758-63, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23336937

ABSTRACT

BACKGROUND: We sought to investigate the short- and mid-term results of the endovascular repair of infrarenal abdominal penetrating aortic ulcers (aPAUs). METHODS: Patients with infrarenal aPAUs treated by endovascular means between March 2004 and June 2012 were recruited. Pre-interventional imaging included computed tomography (CT) or CT angiography. Endoprostheses were chosen and deployed according to standard elective endovascular aneurysm repair anatomical requirements. Endpoints included 30-day survival, in-hospital mortality, 1-year PAU-related mortality, 1-year all-cause mortality, freedom from death and freedom from cumulative complication and interventions. Statistically, the Kaplan-Meier method was applied. RESULTS: Nineteen patients (18 men, median age 70 years (interquartile range, IQR = 59-75)) suffering aPAUs (n = 29, infrarenal = 25) were detected. The median co-morbid severity scoring was 1.0 (IQR = 0.4-1.4). The median follow-up period was 33 months (IQR = 8-51.5). Furthermore, 94.7% of patients had hypertension. Fourteen patients (73.7%) had symptoms, including four of them admitted with shock from large-contained PAU rupture. Endoluminal stent grafting was successfully delivered in all patients. In-hospital mortality was 10.5%. Two patients required secondary interventions (10.5%). The 30-day survival, 1-year PAU-related mortality and 1-year all-cause mortality were 94.7%, 89.5% and 89.5%, respectively. Freedom from death and freedom from cumulative complications and interventions was 86.4% and 86.4%, 78.9% and 78.9%, and 67.9% and 71.2% at 12, 24 and 36 months, respectively. CONCLUSIONS: Urgent and elective endovascular repair of aPAUs can be achieved with high technical success. The significant co-morbid status of the treated patients is illustrated in the considerable in-hospital mortality and underlines the advantage of such treatment over open surgical repair.


Subject(s)
Aortic Diseases/surgery , Atherosclerosis/complications , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Ulcer/surgery , Aged , Aorta, Abdominal/diagnostic imaging , Aorta, Abdominal/surgery , Aortic Diseases/diagnostic imaging , Aortic Diseases/etiology , Aortic Diseases/mortality , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/mortality , Endovascular Procedures/instrumentation , Endovascular Procedures/methods , Endovascular Procedures/mortality , Female , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Postoperative Complications , Prospective Studies , Tomography, X-Ray Computed , Treatment Outcome , Ulcer/diagnostic imaging , Ulcer/etiology , Ulcer/mortality
20.
Int J Artif Organs ; 36(1): 28-38, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23280081

ABSTRACT

Hybrid endografting in endovascular abdominal aortic aneurysm repair (EVAR) is defined as the process of placing a series of two or more different types of covered stents, usually to treat a complex abdominal aortic aneurysm (AAA) or a primary or secondary endoleak. We describe the treatment of a type III, a type Ib, and a type Ia endoleak in three patients respectively, using hybrid solutions, assembling components from different manufacturers. An update of the current clinical and experimental evidence on the application of anatomically compatible, hybrid endograft systems in conventional EVAR is also provided.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endoleak/surgery , Endovascular Procedures/instrumentation , Stents , Aged , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/diagnostic imaging , Endoleak/etiology , Endovascular Procedures/adverse effects , Humans , Male , Multidetector Computed Tomography , Prosthesis Design , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...