Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Mol Sci ; 24(13)2023 Jun 23.
Article in English | MEDLINE | ID: mdl-37445729

ABSTRACT

Photopolymerization is a growing field with an extensive range of applications and is environmentally friendly owing to its energy-efficient nature. Such light-assisted curing methods were initially used to cure the coatings. However, it has become common to use photopolymerization to produce 3D objects, such as bridges or dental crowns, as well as to cure dental fillings. In this study, polymer nanocomposites containing inorganic nanofillers (such as zinc nano-oxide and zinc nano-oxide doped with two wt.% aluminum, titanium nano-oxide, kaolin nanoclay, zirconium nano-oxide, aluminum nano-oxide, and silicon nano-oxide) were fabricated and studied using Real Time FT-IR to investigate the effects of these nanoadditives on the final conversion rates of the obtained nanocomposites. The effects of the fillers on the viscosity of the produced nanocomposites were also investigated, and 3D prints of the selected nanocomposites were presented.


Subject(s)
Aluminum , Silicon Dioxide , Spectroscopy, Fourier Transform Infrared , Printing, Three-Dimensional , Dentistry , Zinc
2.
Colloids Surf B Biointerfaces ; 225: 113269, 2023 May.
Article in English | MEDLINE | ID: mdl-36963315

ABSTRACT

A broad spectrum of biomaterials has been explored in order to design cardiovascular implants of sufficient hemocompatibility. Most of them were extensively tested for the ability to facilitate repopulation by patient cells. It was shown that stiffness, surface roughness, or hydrophilicity of polyelectrolyte films have an impact on adhesion, proliferation, and differentiation of cells. At the same time, it is still unknown how these properties influence cell functionality and as a consequence interactions with blood components under dynamic conditions. In this study, we aimed to determine the impact of chemical cross-linking of Chitosan (Chi) and Chrondroitin Sulphate (CS) on endothelium-blood cross-talk. We have found that the morphology of the endothelium monolayer was not altered by changes in coating properties. However, free radical generation by endothelial cells varied depending on the elastic properties of the coating. Simultaneously, we have observed a significant decrease in the level of adhering and circulating active platelets as well as aggregates when the endothelium monolayer was formed on stiffer films than on the other coating variants. Moreover, the same type of films has promoted significantly higher adhesion of blood morphotic elements when they were not functionalized by endothelium. The observed changes in hemocompatibility indicate the importance of a design of coatings that will promote cellularization in vivo in a relatively short time and which will regulate cell function.


Subject(s)
Biocompatible Materials , Endothelial Cells , Humans , Polyelectrolytes , Cell Adhesion , Endothelium , Biocompatible Materials/pharmacology , Biocompatible Materials/chemistry , Surface Properties
3.
Biomater Sci ; 10(19): 5498-5503, 2022 Sep 27.
Article in English | MEDLINE | ID: mdl-35904349

ABSTRACT

The blood compatibility of self-assembled monolayers (SAMs) of oligoproline, a nonionic antifouling peptide, was investigated using the cone-and-plate assay imitating arterial blood flow conditions. End-capped oligoprolines composed of 6 and 9 proline residues (Pro6 and Pro9) and a Cys residue were synthesized for preparing SAMs (Pro-SAMs) on Au-sputtered glass. The surface of Pro-SAMs indicated hydrophilic property with a smooth topology. The adsorption of blood components and the adhesion of blood cells, including leukocytes and platelets, were strongly suppressed on Pro-SAMs. Moreover, Pro9-SAM did not trigger the activation of platelets (i.e., the conformational change of GPIIb/IIIa and P-selectin (CD62P) expression on platelets and the formation of aggregates). Our results demonstrate that Pro9-SAM completely inhibited acute thrombogenic responses and the activation of platelets under dynamic conditions.


Subject(s)
Blood Platelets , P-Selectin , Adsorption , Proline , Surface Properties
4.
ACS Biomater Sci Eng ; 7(1): 114-121, 2021 01 11.
Article in English | MEDLINE | ID: mdl-33347752

ABSTRACT

The phenomenon of superior biological behavior observed in titanium processed by an unconventional severe plastic deformation method, that is, hydrostatic extrusion, has been described within the present study. In doing so, specimens varying significantly in the crystallographic orientation of grains, yet exhibiting comparable grain refinement, were meticulously investigated. The aim was to find the clear origin of enhanced biocompatibility of titanium-based materials, having microstructures scaled down to the submicron range. Texture, microstructure, and surface characteristics, that is, wettability, roughness, and chemical composition, were examined as well as protein adsorption tests and cell response studies were carried out. It has been concluded that, irrespective of surface properties and mean grain size, the (101̅0) crystallographic plane favors endothelial cell attachment on the surface of the severely deformed titanium. Interestingly, an enhanced albumin, fibronectin, and serum adsorption as well as clearly directional growth of the cells with preferentially oriented cell nuclei have been observed on the surfaces having (0001) planes exposed predominantly. Overall, the biological response of titanium fabricated by severe plastic deformation techniques is derived from the synergistic effect of surface irregularities, being the effect of refined microstructures, surface chemistry, and crystallographic orientation of grains rather than grain refinement itself.


Subject(s)
Osteoblasts , Titanium , Crystallography , Surface Properties , Wettability
5.
Nanomaterials (Basel) ; 10(5)2020 Apr 29.
Article in English | MEDLINE | ID: mdl-32365586

ABSTRACT

Surface functionalization of materials to improve their hemocompatibility is a challenging problem in the field of blood-contacting devices and implants. Polyelectrolyte multilayer films (PEMs), which can mimic functions and structure of an extracellular matrix (ECM), are a promising solution to the urgent need for functional blood-contacting coatings. The properties of PEMs can be easily tuned in order to provide a scaffold with desired physico-chemical parameters. In this study chitosan/chondroitin sulfate (Chi/CS) polyelectrolyte multilayers were deposited on medical polyurethane. Afterwards PEMs were modified by chemical cross-linking and nanoparticles introduction. Coatings with variable properties were tested for their hemocompatibility in the cone-plate tester under dynamic conditions. The obtained results enable the understanding of how substrate properties modulate PEMs interaction with blood plasma proteins and the morphotic elements.

6.
ACS Biomater Sci Eng ; 6(2): 898-911, 2020 02 10.
Article in English | MEDLINE | ID: mdl-33464848

ABSTRACT

The process of modern cardiovascular device fabrication should always be associated with an investigation of how surface properties modulate its hemocompatibility through plasma protein adsorption as well as blood morphotic element activation and adhesion. In this work, a package of novel assays was used to correlate the physicochemical properties of thin ceramic coatings with hemocompatibility under dynamic conditions. Different variants of carbon-based films were prepared on polymer substrates using the magnetron sputtering method. The microstructural, mechanical, and surface physicochemical tests were performed to characterize the coatings, followed by investigation of whole human blood quality changes under blood flow conditions using the "Impact R" test, tubes' tester, and radial flow chamber assay. The applied methodology allowed us to determine that aggregate formation on hydrophobic and hydrophilic carbon-based coatings may follow one of the two different mechanisms dependent on the type and conformational changes of adsorbed blood plasma proteins.


Subject(s)
Blood Platelets , Coated Materials, Biocompatible , Ceramics , Humans , Materials Testing , Surface Properties
7.
Mater Sci Eng C Mater Biol Appl ; 61: 15-22, 2016 Apr 01.
Article in English | MEDLINE | ID: mdl-26838818

ABSTRACT

Hydrogel coatings were stabilized by titanium carbonitride a-C:H:Ti:N buffer layers deposited directly onto the polyurethane (PU) substrate beneath a final hydrogel coating. Coatings of a-C:H:Ti:N were deposited using a hybrid method of pulsed laser deposition (PLD) and magnetron sputtering (MS) under high vacuum conditions. The influence of the buffer a-C:H:Ti:N layer on the hydrogel coating was analysed by means of a multi-scale microstructure study. Mechanical tests were performed at an indentation load of 5 mN using Berkovich indenter geometry. Haemocompatible analyses were performed in vitro using a blood flow simulator. The blood-material interaction was analysed under dynamic conditions. The coating fabrication procedure improved the coating stability due to the deposition of the amorphous titanium carbonitride buffer layer.


Subject(s)
Blood Cells/metabolism , Ceramics , Coated Materials, Biocompatible , Hydrogels , Materials Testing , Membranes, Artificial , Blood Cells/cytology , Blood Flow Velocity , Ceramics/chemistry , Ceramics/pharmacology , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Humans , Hydrogels/chemistry , Hydrogels/pharmacology , Polyurethanes/chemistry , Polyurethanes/pharmacology
SELECTION OF CITATIONS