Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Mech Behav Biomed Mater ; 109: 103856, 2020 09.
Article in English | MEDLINE | ID: mdl-32543416

ABSTRACT

Hybrid ceramic is a promising material for monolithic restorations that could require an individualization through the extrinsic staining to improve aesthetics. Due to the possibilities to treat this ceramic prior to staining, this study evaluated the wear resistance of surface treatments prior to staining and glazing a hybrid ceramic. Thirty-two specimens (Vita Enamic) were divided into 8 groups according to the surface treatment prior to the staining (Polishing: Pol, Acid etching: Ac, Sandblasting with Al2O3: Sd or Self-etching silane: Ses) and glaze application (with: gl or without: gl). The specimens were submitted to the ACTA wear machine simulating the presence of food bolus and antagonist. The wear rate of the stain was determined after 7 intervals of 20,000 cycles, using a profilometer. The surface before and after staining, and after wear were inspected using Scanning Electron Microscopy (SEM). The rates were analyzed using three-way ANOVA and Tukey test. The wear was affected by surface treatment, glaze application and number of cycles (p < 0.001). 100% of the staining was removed after 20,000 cycles for Pol, 40,000 for Pol + gl, 60,000 for Ses + gl, 80,000 for Ac, 100,000 for Sd and Ses, 120,000 for Ac + gl and 140,000 for Sd + gl. SEM showed similar worn surfaces. Sandblasting followed by glaze application was the most durable treatment to maintain the external staining on the hybrid ceramic surface when subjected to three-body wear.


Subject(s)
Ceramics , Dental Porcelain , Materials Testing , Microscopy, Electron, Scanning , Staining and Labeling , Surface Properties
2.
Materials (Basel) ; 13(8)2020 Apr 16.
Article in English | MEDLINE | ID: mdl-32316360

ABSTRACT

Different techniques are available to manufacture polymer-infiltrated ceramic restorations cemented on a chairside titanium base. To compare the influence of these techniques in the mechanical response, 75 implant-supported crowns were divided in three groups: CME (crown cemented on a mesostructure), a two-piece prosthetic solution consisting of a crown and hybrid abutment; MC (monolithic crown), a one-piece prosthetic solution consisting of a crown; and MP (monolithic crown with perforation), a one-piece prosthetic solution consisting of a crown with a screw access hole. All specimens were stepwise fatigued (50 N in each 20,000 cycles until 1200 N and 350,000 cycles). The failed crowns were inspected under scanning electron microscopy. The finite element method was applied to analyze mechanical behavior under 300 N axial load. Log-Rank (p = 0.17) and Wilcoxon (p = 0.11) tests revealed similar survival probability at 300 and 900 N. Higher stress concentration was observed in the crowns' emergence profiles. The MP and CME techniques showed similar survival and can be applied to manufacture an implant-supported crown. In all groups, the stress concentration associated with fractographic analysis suggests that the region of the emergence profile should always be evaluated due to the high prevalence of failures in this area.

3.
J Mech Behav Biomed Mater ; 103: 103579, 2020 03.
Article in English | MEDLINE | ID: mdl-32090908

ABSTRACT

Regardless the materials properties, the vast majority of ceramic restorations could require an individualization through the extrinsic staining to improve aesthetics. This study aimed to compare the staining wear durability of different monolithic ceramics. Specimens of high translucent zirconia (YZHT), zirconia reinforced lithium silicate (ZLS), hybrid ceramic (HC) and feldspathic ceramic (FLD) were divided in five groups according to each material staining technique. The ZLS ceramic was tested with stained prior (ZLS1) and after crystallization (ZLS2). All specimens were extrinsically characterized, i.e. stained, and crystallized or sintered in specific ovens, according to the manufacturer's recommendation. The specimens were submitted to three-body wear tests in ACTA wear machine, simulating the presence of food bolus and antagonist (pH 7, 15 N, 1 Hz). The wear rate of the stain surface was determined after 5 intervals of 200,000 cycles, using a profilometer. The ceramic surface before and after staining, and after wear were inspected by Scanning Electron Microscopy (SEM). The wear rates were analyzed using two-way ANOVA and post-hoc Tukey test. The wear rates of the staining were affected by ceramic and the number of cycles (P < 0.001). 100% of staining was removed after 200,000 cycles for HC, and after 600,000 cycles for YZHT and ZLS1. Staining of ZLS2 and FLD remained on ceramic surface even after 1,000,000 cycles. Furthermore, FLD showed a significant higher staining durability than ZLS2. SEM revealed different surface morphologies for each group with and without staining and after the wear test. Ceramics with fired staining showed higher durability compared to the polymerized one. The feldspar ceramic presented superior staining durability, followed by zirconia reinforced lithium silicate and high translucent zirconia. The conventional two steps staining technique showed improved durability for zirconia reinforced lithium silicate.


Subject(s)
Ceramics , Zirconium , Computer-Aided Design , Dental Porcelain , Materials Testing , Staining and Labeling , Surface Properties
4.
J Mech Behav Biomed Mater ; 100: 103389, 2019 12.
Article in English | MEDLINE | ID: mdl-31398693

ABSTRACT

The present study elucidates the mechanical performance of different designs of resin-bonded fixed dental prostheses made of lithium disilicate simulating masticatory loads of anterior or canine guidance. A three-dimensional model of maxilla was constructed containing central incisor and canine teeth, with edentulous space of the lateral incisor. Three designs of prosthesis were created: retained in central incisor (1-I), retained in canine (1-C) and fixed in both teeth (2-IC). The computational analysis was performed for load in canine and central incisor separately (100N, 45°). The tensile and shear stresses were calculated for the resin-bonded fixed dental prosthesis, bonding surface of each retainer and cement layer using 3D finite element analysis. The 20 highest stress values were analyzed using two-way ANOVA and post-hoc Tukey test, all with α = 5%. The computational analysis showed that 2-retainer resin-bonded fixed dental prosthesis presented the worst prognosis regardless of the mandibular movement. ANOVA showed that Mandibular movement*Retainer interaction influenced on the tensile and shear stresses values (p < 0.01). Higher stresses were observed in the connector region for all groups (13-82.2 MPa; 11-70.2 MPa). In order to reduce the stress concentration in the resin-bonded fixed dental prosthesis and the retainer made of lithium disilicate, the occlusion may serve as the selection criteria of the unitary abutment for better sustainability.


Subject(s)
Dental Porcelain/chemistry , Dental Prosthesis , Dental Stress Analysis/methods , Imaging, Three-Dimensional/methods , Orthodontic Appliances, Fixed , Resins, Synthetic , Computer Simulation , Cuspid/physiology , Finite Element Analysis , Humans , Incisor/physiology , Mandible/physiology , Materials Testing , Maxilla , Prognosis , Shear Strength , Stress, Mechanical , Tensile Strength , Tooth/physiology
5.
Comput Methods Biomech Biomed Engin ; 22(10): 953-960, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31045456

ABSTRACT

The mechanical properties of the adhesive cement used in resin-bonded fixed partial dentures (RBFPD) can modify the clinical performance of the rehabilitation. The goal of this study was to evaluate the influence of the elastic modulus of different cements on the stress distribution in RBFPD using finite element analysis. For that an anterior 3-unit prosthesis was modeled based in a stereolithography file. The model was meshed with tetrahedral elements and materials considered isotropic, linearly elastic and homogeneous. The force applied to the palatal area of the lateral incisor (pontic) at 45° was 100 N. The cements used presented 7 different elastic modulus (E): 2, 6, 10, 14, 18, 22 or 26 GPa. The total deformation, von-Mises stress and maximum principal stress criteria were used to calculate the results. The lower tensile stress occurred in the cement layer with E = 2 GPa [25.6 (canine) and 16.32 MPa (incisor)]. For the prosthesis, the model with the lower tensile stress [287 (canine) and 248 MPa (incisor)] occurred when the cement presented E = 26 GPa. In this way, the stress concentration may have its magnitude modified depending on the stiffness of the cement. Since more flexible cements concentrate less tensile stress in its structure, but allow an increased displacement of the prosthesis, which is friable and rigid and ends up concentrating more tensile stress at its connector. In that way the clinician should avoid the use of adhesive cement with lower elastic modulus due to it increases the stress concentration in the ceramic.


Subject(s)
Dental Cements/pharmacology , Dental Stress Analysis , Denture, Partial, Fixed, Resin-Bonded , Resin Cements/pharmacology , Elastic Modulus , Finite Element Analysis , Humans , Incisor , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL
...