Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Opt Express ; 8(6): 2924-2931, 2017 Jun 01.
Article in English | MEDLINE | ID: mdl-28663916

ABSTRACT

Silicon photonic biosensors are being widely researched as they combine high performance with the potential for low-cost mass-manufacturing. Sensing is typically performed in an aqueous environment and it is assumed that the sensor is chemically stable, as silicon is known to etch in strong alkaline solutions but not in liquids with a pH close to 7. Here, we show that silicon can be affected surprisingly strongly by typical cell culture media, and we observe etch rates of up to 2 nm/hour. We then demonstrate that a very thin (< 10 nm) layer of thermal oxide is sufficient to suppress the etching process and provide the long-term stability required for monitoring cells and related biological processes over extended periods of time. We also show that employing an additional pH buffering compound in the culture medium can significantly reduce the etch rate.

2.
Optica ; 4(2): 229-234, 2017 Feb 20.
Article in English | MEDLINE | ID: mdl-31149627

ABSTRACT

Advanced biomedical diagnostic technologies fulfill an important role in improving health and well-being in society. A large number of excellent technologies have already been introduced and have given rise to the "lab-on-a-chip" paradigm. Most of these technologies, however, require additional instrumentation for interfacing and readout, so they are often confined to the laboratory and are not suitable for use in the field or in wider clinical practice. Other technologies require a light coupling element, such as a grating coupler or a fiber coupler, which complicates packaging. Here, we introduce a novel biosensor based on a chirped guided-mode resonant grating. The chirped grating combines the sensing function with the readout function by translating spectral information into spatial information that is easily read out with a simple CMOS camera. We demonstrate a refractive index sensitivity of 137 nm/RIU and an extrapolated limit of detection of 267 pM for the specific binding of an immunoglobulin G antibody. The chirped guided-mode resonance approach introduces a new degree of freedom for sensing biomedical information that combines high sensitivity with autonomous operation. We estimate that the cost of components is U.S. $10 or less when mass manufactured, so the technology has the potential to truly transform point-of-care applications.

3.
Sci Rep ; 6: 32945, 2016 09 16.
Article in English | MEDLINE | ID: mdl-27633902

ABSTRACT

Photonic nanostructures are used for many optical systems and applications. However, some high-end applications require the use of electron-beam lithography (EBL) to generate such nanostructures. An important technological bottleneck is the exposure time of the EBL systems, which can exceed 24 hours per 1 cm(2). Here, we have developed a method based on a target function to systematically increase the writing speed of EBL. As an example, we use as the target function the fidelity of the Fourier Transform spectra of nanostructures that are designed for thin film light trapping applications, and optimize the full parameter space of the lithography process. Finally, we are able to reduce the exposure time by a factor of 5.5 without loss of photonic performance. We show that the performances of the fastest written structures are identical to the original ones within experimental error. As the target function can be varied according to different purposes, the method is also applicable to guided mode resonant grating and many other areas. These findings contribute to the advancement of EBL and point towards making the technology more attractive for commercial applications.

4.
Biomed Opt Express ; 7(7): 2650-70, 2016 Jul 01.
Article in English | MEDLINE | ID: mdl-27446696

ABSTRACT

In optical coherence tomography (OCT), the axial resolution is directly linked to the coherence length of the employed light source. It is currently unclear if OCT allows measuring thicknesses below its axial resolution value. To investigate spectral-domain OCT imaging in the super-resolution regime, we derived a signal model and compared it with the experiment. Several island thin film samples of known refractive indices and thicknesses in the range 46 - 163 nm were fabricated and imaged. Reference thickness measurements were performed using a commercial atomic force microscope. In vivo measurements of the tear film were performed in 4 healthy subjects. Our results show that quantitative super-resolved thickness measurement can be performed using OCT. In addition, we report repeatable tear film lipid layer visualization. Our results provide a novel interpretation of the OCT axial resolution limit and open a perspective to deeper extraction of the information hidden in the coherence volume.

SELECTION OF CITATIONS
SEARCH DETAIL
...