1.
Phys Med Biol ; 61(9): 3427-42, 2016 May 07.
Article in English | MEDLINE | ID: mdl-27046451

ABSTRACT

The x-ray dark-field contrast accessible via grating interferometry is sensitive to features at length scales well below what is resolvable by a detector system. It is commonly explained as arising from small-angle x-ray scattering (SAXS), and can be implemented both at synchrotron beamlines and with low-brilliance sources such as x-ray tubes. Here, we demonstrate that for tube based setups the underlying process of image formation can be fundamentally different. For focal spots or detector pixels that comprise multiple grating periods, we show that dark-field images contain a strong artificial and system-specific component not arising from SAXS. Based on experiments carried out with a nanofocus x-ray tube and the example of an excised rat lung, we demonstrate that the dark-field contrast observed for porous media transforms into a differential phase contrast for large geometric magnifications. Using a photon counting detector with an adjustable point spread function, we confirm that a dark-field image can indeed be formed by an intra-pixel differential phase contrast that cannot be resolved as such due to a dephasing between the periodicities of the absorption grating and the Talbot carpet. Our findings are further corroborated by a link between the strength of this pseudo-dark-field contrast and our x-ray tube's focal spot size in a three-grating setup. These results must not be ignored when measurements are intended to be reproducible across systems.


Subject(s)
Heart/diagnostic imaging , Interferometry/methods , Lung/diagnostic imaging , Microscopy, Phase-Contrast/methods , Scattering, Small Angle , Trachea/diagnostic imaging , X-Ray Diffraction/methods , Animals , Photons , Rats , Rats, Sprague-Dawley
2.
Phys Med Biol ; 61(2): 527-41, 2016 Jan 21.
Article in English | MEDLINE | ID: mdl-26683256

ABSTRACT

X-ray grating interferometry is one among various methods that allow extracting the so-called phase and visibility contrasts in addition to the well-known transmission images. Crucial to achieving a high image quality are the absorption gratings employed. Here, we present an in-depth analysis of how the grating type and lamella heights influence the final images. Benchmarking gratings of two different designs, we show that a frequently used proxy for image quality, a grating's so-called visibility, is insufficient to predict contrast-to-noise ratios (CNRs). Presenting scans from an excised rat lung, we demonstrate that the CNRs obtained for transmission and visibility images anti-correlate. This is explained by the stronger attenuation implied by gratings that are engineered to provide high visibilities by means of an increased lamella height. We show that even the visibility contrast can suffer from this effect when the associated reduced photon flux on the detector is not outweighed by a corresponding gain in visibility. Resulting in an inevitable trade-off between the quality of the two contrasts, the question of how an optimal grating should be designed can hence only be answered in terms of Pareto optimality.


Subject(s)
Radiographic Image Enhancement/methods , X-Rays , Absorption, Radiation , Animals , Interferometry/methods , Lung/diagnostic imaging , Rats