Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Chromatogr ; 37(4): e5587, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36680551

ABSTRACT

Paxalisib is a pan-PI3K and mTOR inhibitor, currently entering into Phase II clinical trials as a potential drug to treat glioblastoma patients. We report the development and validation of a high-performance liquid chromatography (HPLC) method for the quantitation of paxalisib in mouse plasma as per the US Food and Drug Administration regulatory guidelines. From the mouse plasma, paxalisib and the internal standard (IS; filgotinib) were extracted using ethyl acetate as an extraction solvent. The chromatographic separation of paxalisib and the IS was accomplished on a Symmetry C18 (250 × 4.6 mm, 5.0 µm) column maintained at 40°C using 10 mm ammonium formate and acetonitrile in gradient conditions at a 0.8 ml/min flow-rate. The injection volume was 20 µl. The elution was monitored using a photo-diode array detector set at λmax 280 nm. Paxalisib and the IS eluted at 6.5 and 5.9 min, respectively with a total run time of 10 min. The calibration curve was linear over the range of 111-4,989 ng/ml. Inter- and intraday precision and accuracy, stability studies, dilution integrity and incurred sample reanalysis were investigated and the results met the acceptance criteria. The validated HPLC method was extended to assess the pharmacokinetic parameters of paxalisib in mice.


Subject(s)
Phosphatidylinositol 3-Kinases , Protein Kinase Inhibitors , Mice , Animals , Chromatography, High Pressure Liquid/methods , Reproducibility of Results , Protein Kinase Inhibitors/pharmacokinetics , MTOR Inhibitors , TOR Serine-Threonine Kinases
2.
Biomed Chromatogr ; 37(2): e5548, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36385469

ABSTRACT

Copanlisib is a dual PI3K-δ inhibitor, used in follicular lymphoma treatment. In this research, we report a validated LC-MS/MS method for quantifying copanlisib from a mouse dried blood spot (DBS). We validated the method in line with the guidelines of the US Food and Drug Administration. The liquid-liquid extraction technique was used to extract copanlisib from the DBS discs. We used an Atlantis dC18 column and isocratic mobile phase for the chromatographic separation of copanlisib and the internal standard (idelalisib). The flow was 0.90 ml/min. Under the optimized chromatographic conditions, the retentions of copanlisib and the internal standard were 0.98 and 0.93 min, respectively. Each injection total run time was 2.50 min. The MS/MS ion transitions monitored were m/z 481.31 â†’ 128.00 and 416.10 â†’ 176.10 for copanlisib and the internal standard (IS) idelalisib, respectively. We have used a broad calibration range (1.01-4,797 ng/ml) with a determination coefficient (r2 ) of 0.997. All of the evaluated parameters met the acceptance criteria. Hematocrit did not influence the DBS copanlisib concentrations. We have used the validated method to derive the intravenous pharmacokinetic parameters by quantifying copanlisib in mouse plasma.


Subject(s)
Quinazolines , Tandem Mass Spectrometry , Mice , Animals , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Pyrimidines , Phosphoinositide-3 Kinase Inhibitors , Reproducibility of Results , Dried Blood Spot Testing/methods
3.
Biomed Chromatogr ; 36(8): e5387, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35470912

ABSTRACT

In this study, we report the development and validation of an LC-tandem mass spectrometry method for the simultaneous quantitation of bendamustine and copanlisib in mouse plasma as per the US FDA regulatory guidelines. The sample processing involves extraction of bendamustine and copanlisib along with internal standard (IS; warfarin) from 50 µL mouse plasma using a liquid-liquid extraction method. The chromatographic separation of bendamustine, copanlisib and the IS was achieved on an Atlantis dC18 column using an isocratic mobile phase (5 mM ammonium acetate:methanol, 20:80 v/v). Bendamustine, copanlisib and the IS eluted at 0.88, 1.39 and 0.74 min, respectively, with a total run time of 2.5 min. The calibration curve ranged from 3.99-2996 and 4.33-3248 ng/mL for bendamustine and copanlisib, respectively. Inter- and intra-day precision and accuracy, stability in processed samples and upon storage, dilution integrity and incurred sample reanalysis were investigated for both the analytes. The intra- and inter-day precisions were in the ranges of 2.01%-5.05% and 2.74%-6.13% and 1.98%-7.64 and 8.62%-9.04% for bendamustine and copanlisib, respectively. Stability studies showed that both analytes were stable on bench top for 6 h, in auto-sampler for 24 and at -80°C for 30 days. The validated method was successfully applied to a pharmacokinetic study in mice.


Subject(s)
Spectrometry, Mass, Electrospray Ionization , Tandem Mass Spectrometry , Animals , Bendamustine Hydrochloride , Chromatography, High Pressure Liquid/methods , Chromatography, Liquid/methods , Mice , Pyrimidines , Quinazolines , Reproducibility of Results , Spectrometry, Mass, Electrospray Ionization/methods , Tandem Mass Spectrometry/methods
4.
Drug Res (Stuttg) ; 71(1): 36-42, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32992346

ABSTRACT

Idelalisib is a selective and second-generation PI3K-δ inhibitor, approved for the treatment of non-Hodgkin lymphoma and chronic lymphocytic leukemia. In this paper, we present a fully validated dried blood spot (DBS) method for the quantitation of idelalisib from mice blood using an LC-MS/MS, which was operated under multiple reaction monitoring mode. To the punched DBS discs, acidified methanol enriched with internal standard (IS; larotrectinib) was added and extracted using tert-butyl methyl ether as an extraction solvent with sonication. Chromatographic separation of idelalisib and the IS was achieved on an Atlantis dC18 column using a mixture of 10 mM ammonium formate:acetonitrile (25:75, v/v). The flow-rate and injection volume were 0.80 mL/min and 2.0 µL, respectively. Idelalisib and the IS were eluted at ~0.98 and 0.93 min, respectively and the total run time was 2.00 min. Idelalisib and the IS were analyzed using positive ion scan mode and parent-daughter mass to charge ion (m/z) transition of 416.1→176.1 and 429.1→342.1, respectively was used for the quantitation. The calibration range was 1.01-4 797 ng/mL. No matrix effect and carry over were observed. Haematocrit did not influence DBS idelalisib concentrations. All the validation parameters met the acceptance criteria. The applicability of the validated method was shown in a mice pharmacokinetic study.


Subject(s)
Dried Blood Spot Testing/methods , Drug Monitoring/methods , Purines/analysis , Quinazolinones/analysis , Administration, Oral , Animals , Antineoplastic Agents/administration & dosage , Antineoplastic Agents/analysis , Antineoplastic Agents/pharmacokinetics , Area Under Curve , Biological Availability , Chromatography, High Pressure Liquid/methods , Class I Phosphatidylinositol 3-Kinases/antagonists & inhibitors , Drug Evaluation, Preclinical , Half-Life , Male , Mice , Protein Kinase Inhibitors/administration & dosage , Protein Kinase Inhibitors/analysis , Protein Kinase Inhibitors/pharmacokinetics , Purines/administration & dosage , Purines/pharmacokinetics , Quinazolinones/administration & dosage , Quinazolinones/pharmacokinetics , Tandem Mass Spectrometry/methods
5.
Biomed Chromatogr ; 34(12): e4953, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32706402

ABSTRACT

Larotrectinib is a first-generation tropomyosin kinase inhibitor, approved for the treatment of solid tumors. In this paper, we present a validated dried blood spot (DBS) method for the quantitation of larotrectinib from mouse blood using HPLC-MS/MS, which was operated under multiple reaction monitoring mode. To the DBS disc cards, acidified methanol enriched with internal standard (IS; enasidenib) was added and extracted using tert-butyl methyl ether as an extraction solvent with sonication. Chromatographic separation of larotrectinib and the IS was achieved on an Atlantis dC18 column using 10 mm ammonium formate-acetonitrile (30:70, v/v) delivered at a flow-rate of 0.80 ml/min. Under these optimized conditions, the retention times of larotrectinib and the IS were ~0.93 and 1.37 min, respectively. The total run time was 2.50 min. Larotrectinib and the IS were analyzed using positive ion scan mode and parent-daughter mass to charge ion (m/z) transitions of 429.1 → 342.1 and 474.1 → 267.1, respectively, were used for the quantitation. The calibration range was 1.06-5,080 ng/ml. No matrix effect or carryover was observed. Hematocrit did not influence DBS larotrectinib concentrations. All of the validation parameters met the acceptance criteria. The applicability of the validated method was shown in a mouse pharmacokinetic study.


Subject(s)
Chromatography, High Pressure Liquid/methods , Dried Blood Spot Testing/methods , Pyrazoles/blood , Pyrimidines/blood , Tandem Mass Spectrometry/methods , Animals , Limit of Detection , Linear Models , Male , Mice , Pyrazoles/chemistry , Pyrazoles/pharmacokinetics , Pyrimidines/chemistry , Pyrimidines/pharmacokinetics , Reproducibility of Results
6.
Drug Res (Stuttg) ; 70(2-03): 101-106, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31931548

ABSTRACT

Larotrectinib, is an orally active novel small molecule approved for the treatment of solid tumors in pediatrics and adult patients. It acts by inhibiting tropomyosin receptor kinase. In this paper, we report the development and validation of a high-performance liquid chromatography (HPLC) method for the quantitation of larotrectinib in mice plasma as per the FDA regulatory guideline. Plasma samples processing was accomplished through simple protein precipitation using acetonitrile enriched with internal standard (IS, enasidenib). The chromatographic analysis was performed using a gradient mobile phase comprising 10 mM ammonium acetate and acetonitrile at a flow-rate of 0.8 mL/min on an X-Terra Phenyl column. The UV detection wave length was set at λmax 262 nm. Larotrectinib and the IS eluted at 3.85 and 6.60 min, respectively with a total run time of 8.0 min. The calibration curve was linear over a concentration range of 0.20-5.00 µg/mL (r2=≥0.992). The intra- and inter-day precision and accuracy results were within the acceptable limits. Results of stability studies indicated that larotrectinib was stable on bench-top, in auto-sampler, up to three freeze/thaw cycles and long-term storage at -80°C. The validated HPLC method was successfully applied to a pharmacokinetic study in mice.


Subject(s)
Chromatography, High Pressure Liquid/methods , Protein Kinase Inhibitors/analysis , Pyrazoles/analysis , Pyrimidines/analysis , Animals , Drug Stability , Drug Storage , Male , Mice , Protein Kinase Inhibitors/pharmacokinetics , Pyrazoles/pharmacokinetics , Pyrimidines/pharmacokinetics , Receptor Protein-Tyrosine Kinases/antagonists & inhibitors , Reproducibility of Results , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...