Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Prenat Diagn ; 35(8): 741-7, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26125132

ABSTRACT

OBJECTIVE: Our aim is to evaluate the feasibility to examine the morphology and area of the atrioventricular (AV) valves in normal fetuses and fetuses with cardiac defects using spatiotemporal image correlation (STIC). METHODS: Atrioventricular valves were analyzed longitudinally in STIC volumes of 74 normal fetuses between the 15th and 36th week of pregnancy. The valve area was measured in a rendered view in diastole, the number of valve leaflets in systole. Longitudinal data analysis was performed using linear mixed models. Fifty fetuses with cardiac defects were examined. RESULTS: Examination of 355 STIC volumes of normal fetuses showed in 82.5% sufficient quality. The tricuspid valve leaflets were seen in 200 (68.3%) volumes and the mitral valve leaflets in 219 (74.7%) volumes. The tricuspid valve showed in 61.1% a round, 29.0% rectangle, and 8.9% elliptical shape and the mitral valve in 60.1% round, 28.0% rectangle, and 10.9% elliptical. Regression analysis revealed a positive relationship of the valve area with gestational age (p < 0.0001). Most heart defects with stenosis showed an area below the 5th percentile. CONCLUSION: Prenatal examination of the morphology and area of the AV valves using four-dimensional ultrasound is feasible. A rectangular valve opening is normal, which was visualized in about one third of the normal fetuses.


Subject(s)
Echocardiography, Four-Dimensional , Fetal Heart/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Mitral Valve/diagnostic imaging , Tricuspid Valve/diagnostic imaging , Ultrasonography, Prenatal/methods , Case-Control Studies , Feasibility Studies , Female , Fetal Heart/abnormalities , Fetal Heart/embryology , Heart Defects, Congenital/embryology , Humans , Linear Models , Longitudinal Studies , Mitral Valve/abnormalities , Mitral Valve/embryology , Pregnancy , Pregnancy Trimester, Second , Pregnancy Trimester, Third , Prospective Studies , Reference Values , Spatio-Temporal Analysis , Tricuspid Valve/abnormalities , Tricuspid Valve/embryology
2.
Prenat Diagn ; 34(10): 935-9, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24760486

ABSTRACT

OBJECTIVES: The objectives of this study were to develop reference values for the distance between the atrioventricular valves, called differential insertion of the atrioventricular valves (DIAVV), in normal fetuses using four-dimensional ultrasound with spatio-temporal image correlation and to explore if DIAVV measurement can differentiate between normal hearts and hearts with cardiac defects. METHODS: The DIAVV was analysed longitudinally following a measurement protocol in 74 fetuses between 15 and 36 weeks gestational age. The DIAVV was measured in an apical four-chamber view of the heart in end-diastole. Furthermore, the DIAVV was measured in 70 fetuses with cardiac defects. RESULTS: In total, 337 normal and 70 abnormal spatio-temporal image correlation volumes were examined. Longitudinal regression analysis revealed a positive relationship of the DIAVV with gestational age and fetal biometry (p < 0.0001). The DIAVV of fetuses with double outlet right ventricle, truncus arteriosus, atrioventricular septal defects, Ebstein and tetralogy of Fallot all differed from normal fetuses (p < 0.05). CONCLUSION: Measurement of the DIAVV is a promising tool; however, a well-defined measurement protocol should be followed to accomplish the correct plane and exact moment in the cardiac cycle. This study presents new nomograms following this measurement protocol and reports an abnormal DIAVV in a wide spectrum of congenital heart disease.


Subject(s)
Fetal Heart/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Heart Valves/diagnostic imaging , Ultrasonography, Prenatal , Female , Humans , Pregnancy , Prospective Studies , Reference Values
3.
Ultrasound Obstet Gynecol ; 39(2): 203-9, 2012 Feb.
Article in English | MEDLINE | ID: mdl-21611994

ABSTRACT

OBJECTIVE: To evaluate the clinical accuracy of four-dimensional (4D) echocardiography in the detailed prenatal diagnosis of congenital heart disease (CHD) in a telemedicine setting. METHODS: Ten second-trimester spatiotemporal image correlation (STIC) volumes were sent to three observers in different tertiary care centers with expertise in 4D echocardiography. The 10 volumes were selected based on the type of diagnosis to cover a wide spectrum of CHD anomalies, and also included one normal fetal heart. Observers were asked to provide the diagnosis, the postprocessing modalities used and the time spent on examination, and to give a rating of the confidence for the diagnosis on a 5-point Likert scale. They were free to consult other colleagues, including pediatric cardiologists, but were blinded to the prenatal diagnosis and the neonatal outcome. A diagnostic scoring system was used to evaluate different aspects of the heart defects. The results were compared with neonatal echocardiography or postmortem findings ('gold standard'). RESULTS: In two cases all observers correctly diagnosed all details of the volume datasets. The observer with the best performance reached perfect agreement in six cases and nearly perfect agreement in three. The volumes were most frequently studied by sectional planes and were analyzed in a median time of 11.0 (range, 2.5-30.0) min. The median confidence score was 4.0 (range, 1.0-5.0). CONCLUSIONS: In a telemedicine setting using STIC volumes, fetal cardiac anomalies can be diagnosed correctly by an expert. However, details required for adequate counseling and planning of postnatal care may be missed. STIC by telemedicine is a promising modality, although not accurate enough for exclusive use in clinical decision making regarding treatment, prognosis or termination of pregnancy.


Subject(s)
Echocardiography, Four-Dimensional/methods , Fetal Heart/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Image Interpretation, Computer-Assisted , Telemedicine , Ultrasonography, Prenatal , Cardiac Volume , Female , Gestational Age , Heart Defects, Congenital/embryology , Humans , Observer Variation , Pregnancy , Pregnancy Trimester, Second , Prospective Studies , Telemedicine/methods
4.
Neth Heart J ; 19(3): 134-136, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21475392

ABSTRACT

Two pregnant patients with a sustained symptomatic maternal supraventricular arrhythmia are presented. Both patients were treated with direct-current cardioversion. Electrical cardioversion during pregnancy is a rarely applied but highly effective procedure in the treatment of maternal cardiac arrhythmias and is assumed safe for both mother and child. However, once foetal viability is reached, monitoring of the foetal heart rate is advised and facilities for immediate caesarean section should be available.

5.
Ultrasound Obstet Gynecol ; 36(3): 308-14, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20131339

ABSTRACT

OBJECTIVE: To assess the reliability of measurement of fetal cardiac ventricular volume, stroke volume, and ejection fraction with four-dimensional ultrasound using spatiotemporal image correlation (STIC). METHODS: Volume datasets were collected from two sources: 24 from fetuses over a range of gestational ages and 12 from a miniature balloon model. Datasets were analyzed by three observers, repeatedly in 12 fetal datasets and all balloon datasets. Volume calculations were obtained by manually tracing multiple parallel slices (three-dimensional (3D) slice method). Measurement error was assessed by calculating standard errors of measurement (SEM) and coefficients of variation (CV). Reliability was assessed by calculating interobserver and intraobserver intraclass correlation coefficients (ICC). RESULTS: Measurement errors of balloon volumes were small and reliability was good (SEM

Subject(s)
Cardiac Volume/physiology , Fetal Heart/diagnostic imaging , Stroke Volume/physiology , Echocardiography, Four-Dimensional/methods , Female , Fetal Heart/physiopathology , Gestational Age , Humans , Image Interpretation, Computer-Assisted , Observer Variation , Pregnancy , Ultrasonography, Prenatal
SELECTION OF CITATIONS
SEARCH DETAIL
...