Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
ChemMedChem ; 18(18): e202300218, 2023 09 15.
Article in English | MEDLINE | ID: mdl-37424408

ABSTRACT

The zymogens of the neutrophil serine proteases elastase, proteinase 3, and cathepsin G are converted proteolytically into their pro-inflammatory active forms by the action of cathepsin C. The inhibition of this cysteine protease therefore is an interesting therapeutic approach for the treatment of inflammatory disorders with a high neutrophil burden such as COPD. Based on E-64c-hydrazide as lead structure, we have recently developed a covalently acting cathepsin C inhibitor using a n-butyl residue attached at the amine nitrogen of the hydrazide moiety to efficiently address the deep hydrophobic S2 pocket. To further optimize the affinity and selectivity profile of this inhibitor, the S1'-S2' area was now investigated by a combinatorial approach, showing that Nle-tryptamide is a ligand superior to the initially used Leu-isoamylamide. Using the neutrophil precursor line U937 as a cell culture model, this optimized inhibitor blocks the intracellular cathepsin C activity and thereby suppresses the activation of neutrophil elastase.


Subject(s)
Cathepsin C , Hydrazines , Cathepsin C/metabolism , Hydrazines/pharmacology , Leukocyte Elastase/metabolism , Serine Proteases , Leucine
2.
J Sep Sci ; 38(18): 3262-3270, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26147246

ABSTRACT

A collaborative study on the robustness and portability of a capillary electrophoresis-mass spectrometry method for peptide mapping was performed by an international team, consisting of 13 independent laboratories from academia and industry. All participants used the same batch of samples, reagents and coated capillaries to run their assays, whereas they utilized the capillary electrophoresis-mass spectrometry equipment available in their laboratories. The equipment used varied in model, type and instrument manufacturer. Furthermore, different types of sheath-flow capillary electrophoresis-mass spectrometry interfaces were used. Migration time, peak height and peak area of ten representative target peptides of trypsin-digested bovine serum albumin were determined by every laboratory on two consecutive days. The data were critically evaluated to identify outliers and final values for means, repeatability (precision within a laboratory) and reproducibility (precision between laboratories) were established. For relative migration time the repeatability was between 0.05 and 0.18% RSD and the reproducibility between 0.14 and 1.3% RSD. For relative peak area repeatability and reproducibility values obtained were 3-12 and 9-29% RSD, respectively. These results demonstrate that capillary electrophoresis-mass spectrometry is robust enough to allow a method transfer across multiple laboratories and should promote a more widespread use of peptide mapping and other capillary electrophoresis-mass spectrometry applications in biopharmaceutical analysis and related fields.

SELECTION OF CITATIONS
SEARCH DETAIL
...