Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Cardiothorac Surg ; 13(3): 266-274, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38841089

ABSTRACT

Background: Lifetime management in aortic stenosis (AS) can be facilitated by aortic root enlargement (ARE) to improve anatomy for future valve-in-valve (ViV) procedures. A mitral valve-sparing ARE technique ("Y-incision") and sinotubular junction (STJ) enlargement ("roof" patch aortotomy) allow upsizing by 3-4 valve sizes, but quantitative analysis of changes in root anatomy is lacking. Methods: Among 78 patients who underwent ARE by Y-incision technique (± roof aortotomy closure) we identified 45 patients with high-quality pre- and post-operative computed tomography angiography (CTA) scans to allow analysis of change in aortic root dimensions. Detailed measurements of the annulus/basilar ring and sinuses were performed by an expert imager on both pre- and post-operative CTAs. The basal ring was defined as the functional annulus when a bioprosthetic valve was present. Results: Average age was 65±11 years, the majority were female (29, 64%), and 9 (20%) had undergone prior aortic valve replacement (AVR). Valve upsizing was ≥3 sizes in 41 (91%). Post-operative mean basal ring diameter was larger compared to the native annular diameter (26.3 vs. 25.3 mm, P<0.01) and substantially larger than prior prosthetic valve in redo AVR (25.6 vs. 19.3 mm, P<0.001). Diameters of the sinuses at pre-operative computed tomography (CT) increased by +7.7±2.8 [right sinuses of Valsalva (R SVS)], +6.7±3.0 [left sinuses of Valsalva (L SVS)], and +6.6±2.9 mm [non-coronary sinuses of Valsalva (N SVS)]. Mean diameter of the STJ increased to 38.3±3.7 post-operative (+8.1±3.2 mm). Left main (LM) and right coronary artery (RCA) heights decreased by -6.3±3.3 and -3.7±3.4 mm respectively due to the supra-annular position of the valve, however, the post-operative valve-to-coronary (VTC) artery distances were 6.6±2.3 and 4.9±2.0 mm, respectively. Conclusion: The Y-incision root enlargement technique significantly enlarges the sinus and STJ diameters by 6-7 mm while preserving VTC distances despite upsizing by 3-4 valve sizes, resulting in post-operative anatomy that is favorable for future transcatheter aortic valve-in-surgical aortic valve (TAV-in-SAV).

2.
Radiographics ; 44(4): e230154, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38512728

ABSTRACT

Arrhythmogenic cardiomyopathy (ACM) is a genetic disease characterized by replacement of ventricular myocardium with fibrofatty tissue, predisposing the patient to ventricular arrhythmias and/or sudden cardiac death. Most cases of ACM are associated with pathogenic variants in genes that encode desmosomal proteins, an important cell-to-cell adhesion complex present in both the heart and skin tissue. Although ACM was first described as a disease predominantly of the right ventricle, it is now acknowledged that it can also primarily involve the left ventricle or both ventricles. The original right-dominant phenotype is traditionally diagnosed using the 2010 task force criteria, a multifactorial algorithm divided into major and minor criteria consisting of structural criteria based on two-dimensional echocardiographic, cardiac MRI, or right ventricular angiographic findings; tissue characterization based on endomyocardial biopsy results; repolarization and depolarization abnormalities based on electrocardiographic findings; arrhythmic features; and family history. Shortfalls in the task force criteria due to the modern understanding of the disease have led to development of the Padua criteria, which include updated criteria for diagnosis of the right-dominant phenotype and new criteria for diagnosis of the left-predominant and biventricular phenotypes. In addition to incorporating cardiac MRI findings of ventricular dilatation, systolic dysfunction, and regional wall motion abnormalities, the new Padua criteria emphasize late gadolinium enhancement at cardiac MRI as a key feature in diagnosis and imaging-based tissue characterization. Conditions to consider in the differential diagnosis of the right-dominant phenotype include various other causes of right ventricular dilatation such as left-to-right shunts and variants of normal right ventricular anatomy that can be misinterpreted as abnormalities. The left-dominant phenotype can mimic myocarditis at imaging and clinical examination. Additional considerations for the differential diagnosis of ACM, particularly for the left-dominant phenotype, include sarcoidosis and dilated cardiomyopathy. ©RSNA, 2024 Test Your Knowledge questions for this article are available in the supplemental material.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Cardiomyopathies , Humans , Arrhythmogenic Right Ventricular Dysplasia/diagnostic imaging , Arrhythmogenic Right Ventricular Dysplasia/genetics , Contrast Media , Gadolinium , Cardiomyopathies/diagnostic imaging , Arrhythmias, Cardiac/diagnostic imaging , Arrhythmias, Cardiac/genetics
4.
MAGMA ; 36(3): 451-464, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37043121

ABSTRACT

OBJECTIVE: This study combines a deep image prior with low-rank subspace modeling to enable real-time (free-breathing and ungated) functional cardiac imaging on a commercial 0.55 T scanner. MATERIALS AND METHODS: The proposed low-rank deep image prior (LR-DIP) uses two u-nets to generate spatial and temporal basis functions that are combined to yield dynamic images, with no need for additional training data. Simulations and scans in 13 healthy subjects were performed at 0.55 T and 1.5 T using a golden angle spiral bSSFP sequence with images reconstructed using [Formula: see text]-ESPIRiT, low-rank plus sparse (L + S) matrix completion, and LR-DIP. Cartesian breath-held ECG-gated cine images were acquired for reference at 1.5 T. Two cardiothoracic radiologists rated images on a 1-5 scale for various categories, and LV function measurements were compared. RESULTS: LR-DIP yielded the lowest errors in simulations, especially at high acceleration factors (R [Formula: see text] 8). LR-DIP ejection fraction measurements agreed with 1.5 T reference values (mean bias - 0.3% at 0.55 T and - 0.2% at 1.5 T). Compared to reference images, LR-DIP images received similar ratings at 1.5 T (all categories above 3.9) and slightly lower at 0.55 T (above 3.4). CONCLUSION: Feasibility of real-time functional cardiac imaging using a low-rank deep image prior reconstruction was demonstrated in healthy subjects on a commercial 0.55 T scanner.


Subject(s)
Image Interpretation, Computer-Assisted , Magnetic Resonance Imaging, Cine , Humans , Magnetic Resonance Imaging, Cine/methods , Image Interpretation, Computer-Assisted/methods , Respiration , Heart/diagnostic imaging , Breath Holding , Reproducibility of Results
5.
Magn Reson Med ; 89(2): 536-549, 2023 02.
Article in English | MEDLINE | ID: mdl-36198001

ABSTRACT

PURPOSE: Through-time spiral GRAPPA is a real-time imaging technique that enables ungated, free-breathing evaluation of the left ventricle. However, it requires a separate fully-sampled calibration scan to calculate GRAPPA weights. A self-calibrated through-time spiral GRAPPA method is proposed that uses a specially designed spiral trajectory with interleaved arm ordering such that consecutive undersampled frames can be merged to form calibration data, eliminating the separate fully-sampled acquisition. THEORY AND METHODS: The proposed method considers the time needed to acquire data at all points in a GRAPPA calibration kernel when using interleaved arm ordering. Using this metric, simulations were performed to design a spiral trajectory for self-calibrated GRAPPA. Data were acquired in healthy volunteers using the proposed method and a comparison electrocardiogram-gated and breath-held cine scan. Left ventricular functional values and image quality are compared. RESULTS: A 12-arm spiral trajectory was designed with a temporal resolution of 32.72 ms/cardiac phase with an acceleration factor of 3. Functional values calculated using the proposed method and the gold-standard method were not statistically significantly different (paired t-test, p < 0.05). Image quality ratings were lower for the proposed method, with statistically significantly different ratings (Wilcoxon signed rank test, p < 0.05) for two of five image quality aspects rated (level of artifact, blood-myocardium contrast). CONCLUSIONS: A self-calibrated through-time spiral GRAPPA reconstruction can enable ungated, free-breathing evaluation of the left ventricle in 71 s. Functional values are equivalent to a gold-standard cine technique, although some aspects of image quality may be inferior due to the real-time nature of the data collection.


Subject(s)
Respiration , Ventricular Function, Left , Humans , Artifacts , Breath Holding , Heart , Algorithms , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Reproducibility of Results
7.
J Thorac Imaging ; 35(2): W51-W59, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31584478

ABSTRACT

Ballistic injuries are a major cause of morbidity and mortality in the United States. Unstable patients have high mortality, and only a small subset arrive at the hospital alive. Many patients undergo emergent surgery upon arrival, but a small subset undergo imaging with plain film, computed tomography, and echocardiography. We present a pictorial essay of ballistic and penetrating injuries and their complications with a focus on lung, cardiac, and vascular injury.


Subject(s)
Echocardiography/methods , Radiography/methods , Thoracic Injuries/diagnostic imaging , Wounds, Gunshot/diagnostic imaging , Wounds, Penetrating/diagnostic imaging , Humans , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...