Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
bioRxiv ; 2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38559263

ABSTRACT

Alzheimer's Disease (AD) is the leading cause of dementia. It results in cortical thickness changes and is associated with a decline in cognition and behaviour. Such decline affects multiple important day-to-day functions, including memory, language, orientation, judgment and problem-solving. Recent research has made important progress in identifying brain regions associated with single outcomes, such as individual AD status and general cognitive decline. The complex projection from multiple brain areas to multiple AD outcomes, however, remains poorly understood. This makes the assessment and especially the prediction of multiple AD outcomes - each of which may unveil an integral yet different aspect of the disease - challenging, particularly when some are not strongly correlated. Here, uniting residual learning, partial least squares (PLS), and predictive modelling, we develop an explainable, generalisable, and reproducible method called the Residual Partial Least Squares Learning (the re-PLS Learning) to (1) chart the pathways between large-scale multivariate brain cortical thickness data (inputs) and multivariate disease and behaviour data (outcomes); (2) simultaneously predict multiple, non-pairwise-correlated outcomes; (3) control for confounding variables (e.g., age and gender) affecting both inputs and outcomes and the pathways in-between; (4) perform longitudinal AD disease status classification and disease severity prediction. We evaluate the performance of the proposed method against a variety of alternatives on data from AD patients, subjects with mild cognitive impairment (MCI), and cognitively normal individuals (n=1,196) from the Alzheimer's Disease Neuroimaging Initiative (ADNI). Our results unveil pockets of brain areas in the temporal, frontal, sensorimotor, and cingulate areas whose cortical thickness may be respectively associated with declines in different cognitive and behavioural subdomains in AD. Finally, we characterise re-PLS' geometric interpretation and mathematical support for delivering meaningful neurobiological insights and provide an open software package (re-PLS) available at https://github.com/thanhvd18/rePLS.

2.
Patterns (N Y) ; 4(6): 100759, 2023 Jun 09.
Article in English | MEDLINE | ID: mdl-37409051

ABSTRACT

In this paper, we propose two new provable algorithms for tracking online low-rank approximations of high-order streaming tensors with missing data. The first algorithm, dubbed adaptive Tucker decomposition (ATD), minimizes a weighted recursive least-squares cost function to obtain the tensor factors and the core tensor in an efficient way, thanks to an alternating minimization framework and a randomized sketching technique. Under the canonical polyadic (CP) model, the second algorithm, called ACP, is developed as a variant of ATD when the core tensor is imposed to be identity. Both algorithms are low-complexity tensor trackers that have fast convergence and low memory storage requirements. A unified convergence analysis is presented for ATD and ACP to justify their performance. Experiments indicate that the two proposed algorithms are capable of streaming tensor decomposition with competitive performance with respect to estimation accuracy and runtime on both synthetic and real data.

3.
Comput Methods Programs Biomed ; 233: 107453, 2023 May.
Article in English | MEDLINE | ID: mdl-36921463

ABSTRACT

PURPOSE: Selective internal radiation therapy (SIRT) has been proven to be an effective treatment for hepatocellular carcinoma (HCC) patients. In clinical practice, the treatment planning for SIRT using 90Y microspheres requires estimation of the liver-lung shunt fraction (LSF) to avoid radiation pneumonitis. Currently, the manual segmentation method to draw a region of interest (ROI) of the liver and lung in 2D planar imaging of 99mTc-MAA and 3D SPECT/CT images is inconvenient, time-consuming and observer-dependent. In this study, we propose and evaluate a nearly automatic method for LSF quantification using 3D SPECT/CT images, offering improved performance compared with the current manual segmentation method. METHODS: We retrospectively acquired 3D SPECT with non-contrast-enhanced CT images (nCECT) of 60 HCC patients from a SPECT/CT scanning machine, along with the corresponding diagnostic contrast-enhanced CT images (CECT). Our approach for LSF quantification is to use CNN-based methods for liver and lung segmentations in the nCECT image. We first apply 3D ResUnet to coarsely segment the liver. If the liver segmentation contains a large error, we dilate the coarse liver segmentation into the liver mask as a ROI in the nCECT image. Subsequently, non-rigid registration is applied to deform the liver in the CECT image to fit that obtained in the nCECT image. The final liver segmentation is obtained by segmenting the liver in the deformed CECT image using nnU-Net. In addition, the lung segmentations are obtained using 2D ResUnet. Finally, LSF quantitation is performed based on the number of counts in the SPECT image inside the segmentations. Evaluations and Results: To evaluate the liver segmentation accuracy, we used Dice similarity coefficient (DSC), asymmetric surface distance (ASSD), and max surface distance (MSD) and compared the proposed method to five well-known CNN-based methods for liver segmentation. Furthermore, the LSF error obtained by the proposed method was compared to a state-of-the-art method, modified Deepmedic, and the LSF quantifications obtained by manual segmentation. The results show that the proposed method achieved a DSC score for the liver segmentation that is comparable to other state-of-the-art methods, with an average of 0.93, and the highest consistency in segmentation accuracy, yielding a standard deviation of the DSC score of 0.01. The proposed method also obtains the lowest ASSD and MSD scores on average (2.6 mm and 31.5 mm, respectively). Moreover, for the proposed method, a median LSF error of 0.14% is obtained, which is a statically significant improvement to the state-of-the-art-method (p=0.004), and is much smaller than the median error in LSF manual determination by the medical experts using 2D planar image (1.74% and p<0.001). CONCLUSIONS: A method for LSF quantification using 3D SPECT/CT images based on CNNs and non-rigid registration was proposed, evaluated and compared to state-of-the-art techniques. The proposed method can quantitatively determine the LSF with high accuracy and has the potential to be applied in clinical practice.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Humans , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/radiotherapy , Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/radiotherapy , Retrospective Studies , Single Photon Emission Computed Tomography Computed Tomography , Lung/diagnostic imaging , Image Processing, Computer-Assisted/methods
4.
Med Image Anal ; 78: 102422, 2022 05.
Article in English | MEDLINE | ID: mdl-35339951

ABSTRACT

Multiphase CT scanning of the liver is performed for several clinical applications; however, radiation exposure from CT scanning poses a nontrivial cancer risk to the patients. The radiation dose may be reduced by determining the scan range of the subsequent scans by the location of the target of interest in the first scan phase. The purpose of this study is to present and assess an automatic method for determining the scan range for multiphase CT scans. Our strategy is to first apply a CNN-based method for detecting the liver in 2D slices, and to use a liver range search algorithm for detecting the liver range in the scout volume. The target liver scan range for subsequent scans can be obtained by adding safety margins achieved from Gaussian liver motion models to the scan range determined from the scout. Experiments were performed on 657 multiphase CT volumes obtained from multiple hospitals. The experiment shows that the proposed liver detection method can detect the liver in 223 out of a total of 224 3D volumes on average within one second, with mean intersection of union, wall distance and centroid distance of 85.5%, 5.7 mm and 9.7 mm, respectively. In addition, the performance of the proposed liver detection method is comparable to the best of the state-of-the-art 3D liver detectors in the liver detection accuracy while it requires less processing time. Furthermore, we apply the liver scan range generation method on the liver CT images acquired from radiofrequency ablation and Y-90 transarterial radioembolization (selective internal radiation therapy) interventions of 46 patients from two hospitals. The result shows that the automatic scan range generation can significantly reduce the effective radiation dose by an average of 14.5% (2.56 mSv) compared to manual performance by the radiographer from Y-90 transarterial radioembolization, while no statistically significant difference in performance was found with the CT images from intra RFA intervention (p = 0.81). Finally, three radiologists assess both the original and the range-reduced images for evaluating the effect of the range reduction method on their clinical decisions. We conclude that the automatic liver scan range generation method is able to reduce excess radiation compared to the manual performance with a high accuracy and without penalizing the clinical decision.


Subject(s)
Image Processing, Computer-Assisted , Yttrium Radioisotopes , Humans , Image Processing, Computer-Assisted/methods , Liver/diagnostic imaging , Tomography, X-Ray Computed/methods
5.
Med Phys ; 48(6): 2877-2890, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33656213

ABSTRACT

PURPOSE: Efficient compression of images while preserving image quality has the potential to be a major enabler of effective remote clinical diagnosis and treatment, since poor Internet connection conditions are often the primary constraint in such services. This paper presents a framework for organ-specific image compression for teleinterventions based on a deep learning approach and anisotropic diffusion filter. METHODS: The proposed method, deep learning and anisotropic diffusion (DLAD), uses a convolutional neural network architecture to extract a probability map for the organ of interest; this probability map guides an anisotropic diffusion filter that smooths the image except at the location of the organ of interest. Subsequently, a compression method, such as BZ2 and HEVC-visually lossless, is applied to compress the image. We demonstrate the proposed method on three-dimensional (3D) CT images acquired for radio frequency ablation (RFA) of liver lesions. We quantitatively evaluate the proposed method on 151 CT images using peak-signal-to-noise ratio ( PSNR ), structural similarity ( SSIM ), and compression ratio ( CR ) metrics. Finally, we compare the assessments of two radiologists on the liver lesion detection and the liver lesion center annotation using 33 sets of the original images and the compressed images. RESULTS: The results show that the method can significantly improve CR of most well-known compression methods. DLAD combined with HEVC-visually lossless achieves the highest average CR of 6.45, which is 36% higher than that of the original HEVC and outperforms other state-of-the-art lossless medical image compression methods. The means of PSNR and SSIM are 70 dB and 0.95, respectively. In addition, the compression effects do not statistically significantly affect the assessments of the radiologists on the liver lesion detection and the lesion center annotation. CONCLUSIONS: We thus conclude that the method has a high potential to be applied in teleintervention applications.


Subject(s)
Data Compression , Anisotropy , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Neural Networks, Computer , Signal-To-Noise Ratio
6.
J Neural Eng ; 17(1): 016023, 2020 01 06.
Article in English | MEDLINE | ID: mdl-31905174

ABSTRACT

OBJECTIVE: Epilepsy is one of the most common brain disorders. For epilepsy diagnosis or treatment, the neurologist needs to observe epileptic spikes from electroencephalography (EEG) data. Since multi-channel EEG records can be naturally represented by multi-way tensors, it is of interest to see whether tensor decomposition is able to analyze EEG epileptic spikes. APPROACH: In this paper, we first proposed the problem of simultaneous multilinear low-rank approximation of tensors (SMLRAT) and proved that SMLRAT can obtain local optimum solutions by using two well-known tensor decomposition algorithms (HOSVD and Tucker-ALS). Second, we presented a new system for automatic epileptic spike detection based on SMLRAT. MAIN RESULTS: We propose to formulate the problem of feature extraction from a set of EEG segments, represented by tensors, as the SMLRAT problem. Efficient EEG features were obtained, based on estimating the 'eigenspikes' derived from nonnegative GSMLRAT. We compared the proposed tensor analysis method with other common tensor methods in analyzing EEG signal and compared the proposed feature extraction method with the state-of-the-art methods. Experimental results indicated that our proposed method is able to detect epileptic spikes with high accuracy. SIGNIFICANCE: Our method, for the first time, makes a step forward for automatic detection EEG epileptic spikes based on tensor decomposition. The method can provide a practical solution to distinguish epileptic spikes from artifacts in real-life EEG datasets.


Subject(s)
Action Potentials/physiology , Brain/physiopathology , Electroencephalography/methods , Epilepsy/physiopathology , Signal Processing, Computer-Assisted , Adolescent , Adult , Aged , Child , Child, Preschool , Epilepsy/diagnosis , Female , Humans , Male , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...