Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Polymers (Basel) ; 13(24)2021 Dec 09.
Article in English | MEDLINE | ID: mdl-34960869

ABSTRACT

Orthokeratology lenses are commonly used for myopia control, especially in children. Tear lipids and proteins are immediately adsorbed when the lens is put on the cornea, and protein deposition may cause discomfort or infection. Therefore, we established an in vitro protein deposition analysis by mimicking the current cleaning methods for orthokeratology lens wearers for both short-term and long-term period. The results showed that the amounts of tear proteins accumulated daily and achieved a balance after 14 days when the lens was rubbed to clean or not. Protein deposition also affected the optical characteristics of the lens regardless of cleaning methods. Our results provided an in vitro analysis for protein deposition on the lens, and they may provide a potential effective method for developing care solutions or methods that can more effectively remove tear components from orthokeratology lenses.

2.
Polymers (Basel) ; 12(1)2020 Jan 07.
Article in English | MEDLINE | ID: mdl-31936178

ABSTRACT

Feeling comfortable is an important issue for contact lens wearers as contact lenses are worn for an extensive period of time. It has been shown that the in vitro friction coefficient of contact lenses is correlated to the degree of in vivo comfort, thus many studies focus on establishing friction testing methods for investigating the friction coefficient of contact lenses or contact lens care solution. We have previously demonstrated the lubricating property of poly-gamma-glutamic acid (γ-PGA)-containing care solution, and it could reduce the high friction coefficient caused by lysozyme. However, the mechanism of how γ-PGA-containing care solution reduces the lysozyme-induced friction coefficient of contact lenses is unclear. We investigated the bio-tribological effect of γ-PGA on ionic contact lenses in the presence of lysozyme by testing load and velocity variations. The ability to remove lysozyme deposition by γ-PGA and viscosity analysis of γ-PGA-containing care solutions were also investigated to understand the potential mechanism. Our results showed that the friction coefficient of γ-PGA-containing care solution with lysozyme was the lowest in both load and velocity variations, and γ-PGA functions distinctly in the lysozyme-ionic contact lens system. We proposed a model of how γ-PGA could reduce the friction coefficient in these two conditions.

SELECTION OF CITATIONS
SEARCH DETAIL
...