Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Pediatr ; 183(2): 815-825, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38017338

ABSTRACT

Foreign body aspiration (FBA) is a common cause of pediatric morbidity, but a standardized protocol to guide decision-making about bronchoscopy is lacking. We aimed to validate a new Foreign body aspiration score (FOBAS) for the pediatric emergency department (ED). Patients aged 0-18 years referred to the ED for suspected FBA were prospectively enrolled. FOBAS was calculated according to clinical features of a choking episode, sudden cough, exposure to nuts, absence of fever and rhinitis, stridor, and unilateral auscultatory and radiological findings. FBA risk was evaluated based on the total score (low, 1-3; moderate, 4-6; high, 7-10). Low-risk children were discharged from the ED and followed clinically. Moderate-risk children were hospitalized and evaluated by a pediatric pulmonologist, and high-risk children were referred directly for therapeutic bronchoscopy. Among the 100 enrolled children (59% males; median age 20 [interquartile range 11-39] months), a foreign body was diagnosed in 1/49 (2%), 14/41 (34.1%), and 9/10 (90%) with low, moderate, and high FOBAS, respectively (P < .001). Logistic regression indicated a higher risk for FBA with higher scores. The odds ratio for each additional point was 2.75 (95% confidence interval 1.78-4.24), and FOBAS showed a high predictive value for FBA (area under the curve 0.89). FOBAS implementation significantly reduced the rate of negative bronchoscopies, from 67.4% annually during 2016-2019 to 50% in 2020 (P = .042). CONCLUSION: FOBAS reliably predicts FBA in cases of suspected FBA and improves management and in-hospital decision-making. WHAT IS KNOWN: • Foreign body aspiration is a major cause of pediatric morbidity and mortality. • Currently, there is no unified protocol for children referred to the emergency department for suspected FBA, therefore, a well-defined algorithm is needed to improve the decision-making process. WHAT IS NEW: • The pediatric Foreign body aspiration score (FOBAS) is a new, prospectively validated clinical score that shows high sensitivity and specificity for the presence of FBA in children. • FOBAS reduces unnecessary admissions and invasive procedures and leads to better clinical outcomes.


Subject(s)
Airway Obstruction , Foreign Bodies , Male , Child , Humans , Infant , Child, Preschool , Female , Retrospective Studies , Respiratory Aspiration/diagnosis , Respiratory Aspiration/etiology , Respiratory Aspiration/therapy , Bronchoscopy/adverse effects , Bronchoscopy/methods , Airway Obstruction/diagnosis , Airway Obstruction/etiology , Airway Obstruction/therapy , Algorithms , Foreign Bodies/diagnosis , Foreign Bodies/therapy , Foreign Bodies/complications
2.
Eur J Pediatr ; 182(9): 4205-4212, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37450025

ABSTRACT

Foreign Body Aspiration (FBA) is a common medical emergency among young children, but the evaluation and management of a suspected FBA case can vary across physicians and centers. We aimed to identify which clinical, laboratory, and radiological findings can predict FBA in children and to evaluate a clinical score to improve FBA prediction. This is a retrospective cohort study of patients aged 0-18 years admitted to Soroka University Medical Center between 2010 and 2020 with suspected FBA. All patients underwent flexible bronchoscopy and were divided into positive and negative FBA groups. A newly developed foreign body aspiration score (FOBAS), based on medical history, physical examination, and chest X-ray findings, was evaluated for its predictability. The study included 412 children (median age 21 months, 56.8% females), of whom 154 (37.4%) had FBA and 258 (62.6%) did not. Multivariate regression analysis showed exposure to nuts/seeds, unilateral wheezing or decreased breath sounds, stridor, and suggestive findings on chest X-ray were significant risk factors for FBA (OR [95%CI] -1.994[1.290-3.082], 1.487[1.206-1.832], 1.883 [1.011-3.509] and 2.386[1.917-2.970], respectively). However, a choking episode, acute cough, and absence of fever and rhinorrhea did not predict FBA. FOBAS showed an increased risk of FBA for each additional point of the score, with an odds ratio of 1.572 (95% CI-1.389-1.799).  Conclusion: FOBAS is a good predictor for the presence of FBA in children. Once prospectively validated, FOBAS could aid in decision-making at the emergency department, enabling more standardized care, reducing unnecessary procedures, and leading to better clinical outcomes. What is Known: • The evaluation and management of a child with suspected foreign body aspiration (FBA) vary across physicians and centers, without a consensus regarding the indications and criteria for performing bronchoscopy. • Flexible bronchoscopy is the standard procedure for the diagnosis and sometimes treatment of FBA in children, but it may hold potential complications. What is New: • We propose a newly developed foreign body aspiration score (FOBAS), based on medical history, physical examination, and chest X-ray findings, for the prediction of FBA in children at the emergency department. • The FOBAS is a good predictor of FBA in children. The score enables more standardized care and may reduce unnecessary procedures.


Subject(s)
Foreign Bodies , Female , Child , Humans , Infant , Child, Preschool , Male , Retrospective Studies , Foreign Bodies/diagnosis , Foreign Bodies/complications , Bronchoscopy/adverse effects , Bronchoscopy/methods , Radiography , Cough/etiology , Respiratory Sounds/etiology
4.
Pediatr Pulmonol ; 58(2): 425-432, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36224102

ABSTRACT

BACKGROUND: Since the outbreak of the coronavirus disease 2019 (COVID-19) pandemic, there has been a decline in pediatric emergency department visits. Our aim was to assess the pattern of pediatric foreign body aspiration (FBA) during the first year of the COVID-19 pandemic, in comparison to the prior years. METHODS: In this retrospective multicenter study, we compared the number of children who presented with FBA during the COVID-19 year (March 1, 2020 to February 28, 2021) to the annual average of the years 2016-2019. We also compared the lockdown periods to the postlockdown periods, and the percentage of missed FBA, proven FBA, and flexible bronchoscopy as the removal procedure. RESULTS: A total of 345 children with FBA from six centers were included, 276 in the pre-COVID-19 years (average 69 per year) and 69 in the COVID-19 year. There was no difference in the prevalence of FBA between the COVID-19 year and any of the prior 4 years. Examining the lockdown effect, the monthly incidence of FBA dropped from a pre-COVID-19 average of 5.75 cases to 5.1 cases during lockdown periods and increased to 6.3 cases in postlockdown periods. No difference in the percentage of missed FB or proven FB was observed. There was a significant rise in the usage of flexible bronchoscopy as the removal procedure (average of 15.4% vs. 30.4%, p = 0.001). CONCLUSION: There were fewer cases of pediatric FBA during lockdown periods, compared to post-lockdown periods, presumably related to better parental supervision, with no difference in the prevalence of FBA during the COVID-19 year.


Subject(s)
COVID-19 , Foreign Bodies , Child , Humans , Pandemics , Israel/epidemiology , Respiratory Aspiration/epidemiology , COVID-19/epidemiology , Communicable Disease Control , Bronchoscopy/methods , Retrospective Studies , Foreign Bodies/epidemiology
5.
Eur J Pediatr ; 180(5): 1443-1450, 2021 May.
Article in English | MEDLINE | ID: mdl-33389071

ABSTRACT

Rigid bronchoscopy is the procedure of choice for removal of inhaled foreign bodies. In this retrospective study, we assessed the safety and efficacy of flexible bronchoscopy use in the removal of inhaled foreign bodies in children. One hundred eighty-two patients (median age of 24 months, 58% males) underwent an interventional bronchoscopy for the removal of inhaled foreign body between 2009 and 2019, 40 (22%) by flexible, and 142 (78%) by rigid bronchoscopy. 88.73% of rigid and 95% of flexible bronchoscopies were successful in foreign bodies removal (p value = 0.24). Complication rate was higher among rigid bronchoscopy (9.2% vs. 0%, p = 0.047). From 2017 onwards, following the implementation of flexible bronchoscopy for foreign bodies removal, 64 procedures were performed, 33 (51.6%) flexible, and 31 (48.4%) rigid. Procedure length was shorter via flexible bronchoscopy (42 vs 58 min, p = 0.016). Length of hospital stay was similar.Conclusion: In our hands, flexible bronchoscopy is an efficient and safe method for removal of inhaled foreign bodies in children, with shorter procedure time and minimal complication rate. Flexible bronchoscopy could be considered as the procedure of choice for removal of inhaled foreign bodies in children, by an experienced multidisciplinary team. What is Known: • Rigid bronchoscopy is currently the gold standard for removal of inhaled foreign bodies in children. • Rigid bronchoscopy has a relatively high complication rate compared to flexible bronchoscopy. What is New: • Flexible bronchoscopy is a short, safe, and efficient procedure to remove inhaled foreign bodies in children, compared to rigid bronchoscopy. • Flexible bronchoscopy could be proposed as the procedure of choice for removal of inhaled foreign bodies in children, if an experienced operator is available.


Subject(s)
Bronchoscopy , Foreign Bodies , Bronchi , Child , Child, Preschool , Female , Foreign Bodies/diagnosis , Foreign Bodies/therapy , Humans , Infant , Male , Retrospective Studies , Trachea
7.
J Med Case Rep ; 6: 108, 2012 Apr 13.
Article in English | MEDLINE | ID: mdl-22502764

ABSTRACT

INTRODUCTION: The Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) has been shown to successfully facilitate difficult intubations when other methods have failed. The Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) has a fixed length of 56 cm, and it has been suggested in the literature that it may be too short for safe use in patients who are tall. CASE PRESENTATION: We present the case of a 32-year-old, 180 cm tall Caucasian woman with a predicted difficult airway who presented to our facility for an emergency cesarean section. After several failed intubation attempts via direct laryngoscopy, an airway was established with a laryngeal mask airway. After delivery of a healthy baby, our patient's condition necessitated tracheal intubation. A fiber-optic bronchoscope loaded with an Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) was passed through the laryngeal mask airway into the trachea until just above the carina, but was too short to safely allow for the passage of an endotracheal tube. CONCLUSIONS: We present a novel technique in which the Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) was replaced with a longer (100 cm) exchange catheter, over which an endotracheal tube was passed successfully into the trachea.

SELECTION OF CITATIONS
SEARCH DETAIL
...