Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
BMC Geriatr ; 23(1): 388, 2023 06 24.
Article in English | MEDLINE | ID: mdl-37353730

ABSTRACT

BACKGROUND: The impact of real-time remote cardiac rehabilitation (CR) on health and disability-related outcomes and its correlation with physical function are unknown. We compared the effectiveness of real-time remote CR with that of hospital-based CR on physical function improvement and physical functions of improvement (Δ) to clarify the relationship between health and disability at baseline. METHODS: Patients with cardiovascular diseases (CVDs) were enrolled (n = 38) in this quasi-randomised controlled trial and underwent 4 weeks of hospital-based CR, followed by 12 weeks of remote or hospital-based CR based on quasi-randomised allocation. Patients were assessed at baseline and after 12 weeks of remote or hospital-based CR using the shortened version of the World Health Organization (WHO) Quality of Life scale (WHOQOL-BREF) for subjective satisfaction, WHO Disability Assessment Schedule (WHODAS2.0-J) for objective performance, and cardiopulmonary exercise test for physical function and peak oxygen uptake (peak VO2). The trends in measured variables from baseline to the post-CR stage were analysed. RESULTS: Sixteen patients (mean age, 72.2 ± 10.4 years) completed remote CR, and 15 patients (mean age, 77.3 ± 4.8 years) completed hospital-based CR. The post-CR physical function differed significantly between the groups (Δpeak VO2, 2.8 ± 3.0 versus 0.84 ± 1.8 mL·min-1·kg-1; p < 0.05). The differences in post-CR changes in the WHOQOL-BREF scores between the groups were insignificant. The post-CR changes in the WHODAS2.0-J scores were significantly lower in the remote CR group than in the hospital-based CR group (ΔWHODAS2.0-J score, -8.56 ± 14.2 versus 2.14 ± 7.6; p < 0.01). Forward multiple stepwise regression analysis using overall data showed that the intervention method (ß = 0.339, p < 0.05), baseline cognition (ß = - 0.424, p < 0.05), and social interaction level (ß = 0.658, p < 0.01; WHODAS2.0-J) were significant independent contributors to Δpeak VO2 (r2 = 0.48, F = 8.13, p < 0.01). CONCLUSIONS: Remote CR considerably improved physical function and objective performance in patients with CVDs. Remote CR can be used to effectively treat stable patients who cannot visit hospitals. TRIAL REGISTRATION: This interventional trial was registered at the UMIN-CTR registry (trial title: Development of remote programme for cardiac rehabilitation using wearable electrocardiograph; trial ID: UMIN000041746; trial URL: https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000046564 ; registration date: 2020/09/09).


Subject(s)
Cardiac Rehabilitation , Humans , Aged , Aged, 80 and over , Cardiac Rehabilitation/methods , Quality of Life , Exercise Tolerance , Exercise Test , Electrocardiography , Exercise Therapy/methods
2.
Heart Vessels ; 38(1): 131-135, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35298672

ABSTRACT

Tissue characterization plays an important role in the development of acute coronary syndromes. iMap is an intravascular ultrasound (IVUS) tissue characterization system that provides useful information by reconstructing color-coded maps. Mechanical properties due to dynamic mechanical stress during a cardiac cycle may also trigger vulnerable plaque. Speckle tracking IVUS (ST-IVUS) has been introduced to observe plaque behavior in relation to mechanical properties. We report the case of an 84-year-old woman with stable coronary artery disease who underwent percutaneous coronary intervention, at which time IVUS demonstrated mainly three low echoic areas like lipid pools with thick fibrous caps. Pathological evaluation with iMap revealed that one low echoic area was occupied with necrotic tissue and that the other two areas occupied fibrotic. Although those tissue characterizations were different, they showed similar stretching behavior at systole by ST-IVUS which depicted plaque behavior from IVUS images using a color mapping. The mechanical properties of individual coronary plaques may differ depending on the tissue disposition. It is necessary to consider mechanical properties using ST-IVUS as well as to evaluate tissue characterization in plaque risk stratification.


Subject(s)
Acute Coronary Syndrome , Coronary Artery Disease , Plaque, Atherosclerotic , Female , Humans , Aged, 80 and over , Ultrasonography, Interventional/methods , Plaque, Atherosclerotic/pathology , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Heart , Acute Coronary Syndrome/diagnostic imaging , Acute Coronary Syndrome/etiology , Fibrosis , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology
3.
Heart Vessels ; 36(6): 827-835, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33462685

ABSTRACT

Visit-to-visit variability in systolic blood pressure (VVV-SBP) has been associated with increased cardiac events. Hence, volume analysis by two-dimensional speckle-tracking echocardiography (2-DSTE) allows physicians to easily measure phasic left atrial (LA) function. However, the relationship of VVV-SBP and functional deformation of the left atrium with patients' clinical outcome is unclear. The aim of the study was to investigate the relationship between phasic LA function and VVV-SBP. The subjects were 70 male participants in whom 2-DSTE was performed to measure blood pressure at health check-ups every year for 5 years. The standard deviation of systolic blood pressure (SBP) was calculated to assess VVV-SBP. The average SBP (Ave-SBP) was also assessed. Total emptying function (EF) (reservoir function), passive EF (conduit function), and active EF (booster pump function) of the left atrium were calculated to evaluate phasic LA function by 2-DSTE. The Pearson correlation, simple regression analysis, and multivariate logistic regression analysis were used in data analysis. Participants' mean age was 50 ± 10 years, and 16 participants had hypertension. VVV-SBP correlated with total EF (r = - 0.30, p = 0.014) and active EF (r = - 0.35, p = 0.003). There was no correlation between the standard deviation of SBP and passive EF (r = - 0.10, p = 0.39). Ave-SBP had no significant relationship with total EF (r = - 0.06, p = 0.62), passive EF (r = - 0.08, p = 0.50), or active EF (r = - 0.03, p = 0.78). Active EF was also associated with VVV-SBP in multiple regression analysis. The active EF was significantly decreased in the highest quartile of VVV-SBP. Despite the small sample size of our study, the VVV-SBP showed a relationship with the phasic LA function. Our findings suggest that high VVV-SBP is noted to be associated with cardiovascular risk including a deterioration of LA function in clinical practice.


Subject(s)
Atrial Fibrillation/physiopathology , Atrial Function, Left/physiology , Blood Pressure/physiology , Echocardiography/methods , Heart Atria/diagnostic imaging , Office Visits/statistics & numerical data , Adult , Aged , Atrial Fibrillation/diagnosis , Female , Follow-Up Studies , Heart Atria/physiopathology , Humans , Male , Middle Aged , Retrospective Studies , Risk Factors , Time Factors , Young Adult
4.
Heart Vessels ; 34(7): 1212-1220, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30684028

ABSTRACT

P-wave signal-averaged electrocardiography (P-SAECG) can detect imperceptible conduction abnormalities, and volume analysis using two-dimensional speckle-tracking echocardiography (2-DSTE) allows us to easily measure the phasic function of the left atrium (LA). Both conduction abnormalities and functional deformation of the LA may be linked to the clinical outcome; however, the exact relationship is unclear. The aim of this study was to investigate the relationship between the phasic function of the LA and electrical conduction using P-SAECG and 2-DSTE. The subjects were 112 male volunteers (age 46.9 ± 13.2 years) with normal cardiac function who underwent P-SAECG and 2-DSTE. The filtered p-wave duration (FPD) and the root-mean-square voltage for the last 20 ms (RMS20) on P-SAECG wave were measured in ms and µV, respectively. Total emptying function (EF) (reservoir function), passive EF (conduit function), and active EF (booster pump function) of the LA were calculated as percentages to evaluate phasic LA function using 2DSTE. The mean FPD was 134.3 ± 11.7 ms and the mean RMS20 was 4.59 ± 2.39 µV. The mean total EF was 60.5 ± 13.1%, mean passive EF was 39.4 ± 13.9%, and mean active EF was 35.1 ± 13.9%. FPD had a negative correlation with passive EF (r = - 0.20, p = 0.039). FPD showed no significant relationship with total EF (r = - 0.03, p = 0.78) or active EF (r = 0.13, p = 0.18). There was a significant association between RMS20 and passive EF (r = 0.19, p = 0.048); however, no there was no correlation between RMS20 and total EF (r = 0.12, p = 0.23), or between RMS20 and passive EF (r = - 0.02, p = 0.86). In multivariate regression analysis, passive EF was an independent factor that influenced FPD duration. This study indicated that FPD was associated with conduit function, which includes phasic LA function. Therefore, electrical conduction of the LA and left ventricular diastolic function are closely related. In the clinical setting, when conduction abnormalities are detected, lifestyle measures or interventions can be applied to reduce cardiovascular risk.


Subject(s)
Echocardiography , Electrocardiography , Heart Atria/diagnostic imaging , Heart Atria/physiopathology , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/physiopathology , Adult , Elasticity Imaging Techniques , Humans , Image Interpretation, Computer-Assisted/methods , Male , Middle Aged , Multivariate Analysis , Regression Analysis , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...