Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Chromatogr A ; 1085(1): 110-6, 2005 Aug 26.
Article in English | MEDLINE | ID: mdl-16106856

ABSTRACT

A simple and versatile cation-exchange chromatography technique for the simultaneous determination of urinary creatinine (Cre), creatine (Crn), methionine (Met), tyrosine (Tyr), phenylalanine (Phe), histidine (His), and tryptophan (Trp) was developed. A novel low-capacity cation-exchange column packed with a newly developed sulfoacylated hypercross-linked macroreticular polystyrene-divinylbenzene resin, referred to as TMR-A/75 (capacity: 75 microequiv/column), was successfully used with a binary dual-mode gradient eluting system. Two solvents, (A) 25 mM phosphoric acid-methanol (30:70, v/v) and (B) 25 mM disodium hydrogenphosphate-methanol (30:70, v/v) were pumped through the column by programming solvent delivery ratios as 0 to 5 min: A-B (55:45, pH 3.6); 5-21 min: A-B (49:51, pH 5.3); and 21-35 min: A-B (55:45, pH 3.6). The flow rate was simultaneously time-programmed to be 0.6 mL/min from 0 to 19 min and to be 1.0 mL/min from 19 to 35 min. This eluting system could permit the use of the UV detection at 210 nm. The analytes, Crn, Met, Tyr, His, Cre, Phe, and Trp, were well separated in this order in 27 min with minimum resolution of approximately 2, and the cycle time was about 35 min. Retention time of each analyte was very reproducible with relative standard deviations (RSDs) between 0.05 and 0.38% (n = 5). The peak area responses were also reproducible with RSDs between 0.74 and 2.24% (n = 5). Calibration lines based on area data were linear from 1 to 1000 microM with r2 values of 0.9998 (Crn), 0.9998 (Met), 0.9999 (Tyr), 0.9999 (His), 1.0000 (Cre), 1.0000 (Phe), and 0.9999 (Trp). The method was applicable to the screening and/or chemical diagnosis of inherited metabolic disorders such as phenylketonuria (PKU), tyrosinemia, and Lowe syndrome. The creatinine ratios of diagnostic markers (microM/microM Cre) were easily determined. The Phe/Cre ratios for five urines from patients with PKU ranged from 0.162 to 0.521, and the Tyr/Cre ratio for tyrosinemia was 0.147. The ratios of Tyr/Cre, Phe/Cre, and Trp/Cre for Lowe syndrome were 0.497, 0.321, and 0.495, respectively. In contrast, the creatinine ratios for healthy newborns showed one digit lower than those for patients did. The developed method is very practical and can provide useful information and results for the clinical or biomedical researches with low analytical run costs.


Subject(s)
Amino Acids/analysis , Chromatography, Ion Exchange/methods , Creatine/analysis , Creatinine/analysis , Spectrophotometry, Ultraviolet/methods , Amino Acids/urine , Cation Exchange Resins , Chromatography, Ion Exchange/instrumentation , Creatine/urine , Creatinine/urine , Humans , Hydrogen-Ion Concentration , Infant, Newborn , Phenylketonurias/diagnosis , Phenylketonurias/urine , Polystyrenes/chemistry , Reproducibility of Results , Sensitivity and Specificity , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...